Dräger Polytron 7000 Detection of toxic gases and oxygen

Similar documents
Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger REGARD -1 Control System

Dräger REGARD 3900 Series Control System

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Flame 5000 Flame Detection

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Pac 3500 Single-Gas Detection Device

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger X-am 2500 Multi-Gas Detector

Dräger Polytron 8200 Stationary gas detector (CatEx)

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger REGARD -1 Control System

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger X-am 5000 Multi-Gas Detector

Dräger Pac 5500 Single-Gas Detection Device

Dräger Configuration and Evaluation Software

Dräger REGARD -1 Control System

Dräger QuadGard Control System

Dräger X-am 2500 Multi-Gas Detection

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Training Gas Detection Level 3 Maintenance and Repair

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Flame 2350 (UV&IR) Flame Detection

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger VVP 1000 System Components

Dräger X-zone 5500 Area Monitoring

Dräger Flame 2370 (UV&IR) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Dräger Pac 6000 Single-Gas Detection Device

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Bump Test Station Calibration and Bump Testing

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger PIR 7000 Flammable Gas Detection

Dräger Flame 2100 (UV) Flame Detection

Training Authorised Gas Tester Level 1. Basic Information

The SharpEye 40/40I (IR3) Flame Detection

Dräger Pac 8000 Single-Gas Detection Device

Dräger Pac 7000 Single-Gas Detection Device

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Pac 8500 Single-Gas Detection Device

Dräger Bodyguard 1000 Warning Device

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Tropic 2.0 ultrasonic nebuliser

On-site & Shutdown Safety Service CSE Monitoring

Dräger Flame 5000 Flame Detection

GS01 (wireless) Detection of flammable gases and vapours

Dräger X-am 7000 Multi-Gas Detection

Dräger Catalytic Ex-Sensors DrägerSensors

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Portable wet chemical extinguishers

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger X-am 5000 Multi-Gas Detection

Powder Extinguisher ABC - composite Portable powder extinguishers

Foam Extinguisher AB - composite Portable foam extinguishers

Dräger PEX 3000 Flammable Gas Detection

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger X-zone 5500 Multi-Gas Detection Device

The SharpEye 40/40R (IR) Flame Detection

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Oxylog VE300 Emergency & Transport Ventilation

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Oxylog VE300 Emergency & Transport Ventilation

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Oxylog VE300 Emergency & Transport Ventilation

Dräger X-zone 5500 Area Monitoring

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger Pac 6000 Single-Gas Detector

Dräger Flame 2100 Flame Detection

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Dräger Pac 8500 Single-Gas Detector

Dräger Pac 3500 Single-Gas Detection Device

Dräger OR Lights Simply good light

Dräger Flame 2500 Flame Detection

VarioAir Medical Suction Solutions Consumables and Accessories

Transcription:

Dräger Polytron 7000 Detection of toic gases and oygen The Dräger Polytron 7000 is a gas detector that can satisfy many toic and oygen gas measurement applications on a single platform It meets the requirements of the compliance market as well as the high specification requirements of customised solutions Large Display 34 62 mm, 64 128 piel 13" 24" Quick Lock mechanism One half turn lockedt Polytron Docking station Durable GRP housing ST-3812-2003 Simple 3 button operation and navigation Graphics, icons and real tet descriptions

02 Dräger Polytron 7000 Benefits Easy operation Dräger developed the simple and structured software menu of the Polytron 7000 in collaboration with its customers The big graphic display shows status information with the help of icons and plain tet, and guides the user through calibration and configuration Communication interfaces The wide range of outputs, 4 to 20 ma, HART, LON, PROFIBUS or FOUNDATION Fieldbus, enables the use of the Polytron 7000 on either a control system from the Dräger Regard family, or third party control systems The modular design allows for the subsequent retrofit onto any of the mentioned interfaces Remote Sensor With the Polytron 7000 remote sensor adaptor and lead it is possible to mount the sensor up to 30 metres from the polytron 7000 transmitter This enables the user to read and operate the transmitter from a safe area, or detect toic gasses and oygen levels in difficult to reach areas, whilst still being able to view and configure the Polytron 7000 from a convenient location A duct mount kit enables the remote sensor to be mounted direct in elevated pipe work Relay module The Dräger Polytron 7000 can be equipped with a relay module With two gas alarm relays, and one fault alarm relay, the transmitter can either be used as a stand alone gas detector with no need for a controller; or alarm devices can be activated locally saving costs in cabling to and from a controller The analogue signal can still be transmitted back to a controller if desired (Not suitable for use in hazardous areas) Intelligent sensors The Dräger Polytron 7000 can detect over 100 different gases DrägerSensors are specifically designed for the demands of 24 hours per day, 365 days per year operation The large DrägerSensor size gives them their renowned long life The built-in sensor data memory containing all the relevant gas and calibration information, together with on board temperature and pressure compensation gives the DrägerSensor its unsurpassed measurement performance This also allows the Polytron 7000 to accept pre-calibrated sensors, with minimal operator intervention, the Dräger Polytron 7000 is a virtually maintenance free transmitter Software options With three different software dongles, a range of functions are incorporated into the transmitter adjusting it to user or application specific requirementswith the sensor test dongle, the Dräger Polytron 7000 performs many different patented sensor tests that ensure the reliability and functionality of the sensor and gas detection system With the new sensor diagnosis function (including the sensor test), operational demands and the remaining sensor life time is estimated so that maintenance and echange schedules can be created A data

Dräger Polytron 7000 03 Benefits and event saving option is integrated into the data dongle This saves the measured values and events such as alarms and warnings The data can be downloaded onto a PDA m515-e via an IR interface and evaluated on a PC with the Dräger GasVision softwareor at the push of a button, a 15 minute concentration history is shown on the transmitter display Pump module The inclusion of a pump module enables the Polytron 7000 to draw gas samples from difficult to reach areas, the gas sample is then passed across the DrägerSensor for detection The pump unit, like all accessories in the Polytron 7000 range is modular, and can be retrofitted into eisting transmitters (Not suitable for use in hazardous areas) System Components Dräger REGARD 7000 D-6806-2016 The Dräger REGARD 7000 is a modular and therefore highly epandable analysis system for monitoring various gases and vapours Suitable for gas warning systems with various levels of compleity and numbers of transmitters, the Dräger REGARD 7000 also features eceptional reliability and efficiency An additional benefit is the backward compatibility with the REGARD

04 Dräger Polytron 7000 System Components Electrochemical DrägerSensor ST-3831-2003 Fast response, high accuracy, great stability, long life Electrochemical DrägerSensors offer all these benefits You can use the robust and long-life sensors for the selective measurement of the smallest concentrations of toic gases and oygen in ambient air Dräger REGARD 3900 D-27777-2009 The Dräger REGARD 3900 is a standalone, self contained control system for the detection of Toic, Oygen and E hazards The control system is fully configurable between 1 and 16 channels, depending upon the type and quantity of input/output boards installed Dräger REGARD -1 ST-335-2004 The Dräger REGARD -1 is a standalone, self contained single channel control system for the detection of Toic, Oygen and E hazards The control system is fully configurable for a single input from either a 4 to 20 ma transmitter or a Dräger Polytron SE E measuring head

Dräger Polytron 7000 05 Accessories Docking station ST-3809-2003 For easy, time-saving mounting and commissioning of the Dräger Polytron 3000 or 7000 One is required for each Polytron 3000 or 7000 Order No: 83 17 990 Test gas ampoules ST-5695-2006 For use with the calibration bottle Related Products Dräger Polytron 3000 ST-3811-2003 The Dräger Polytron 3000 is an intrinsically safe gas detector for the continuous monitoring of more than 60 toic gases and oygen in ambient air It is the part of a new generation of gas detectors developed on a modular platform Communication to the central control system is done via a 4 to 20 ma signal

06 Dräger Polytron 7000 Related Products Dräger Polytron 5100 EC D-158-2016 The Dräger Polytron 5100 EC is a cost-effective eplosion-proof transmitter for the detection of toic gases or oygen It uses a high performance plug-and-play electrochemical DrägerSensor to detect a specific gas A 2 or 3-wire with 4 to 20 ma output with relays make it compatible with most control systems

Dräger Polytron 7000 07 Technical Data Typ Intrinsically safe transmitter for electrochemical sensors Gases and Ranges Toic gases and oygen, ranges user adjustable, see sensor data sheet Display Large graphic display, 34 62 mm, 64 128 piel 13 24 Menu structure and messages in real tet, 3 button navigation Output Analog 4 to 20 ma Digital HART, LONWORKS, PROFIBUS PA, FOUNDATION fieldbus Warning signal, configurable default: warning signal every 10s for 1s Maintenance signal, configurable 34 ma constant or 4 ma ± 1 ma, 1 Hz modulation Fault signal < 32 ma Power Supply 16,5 to 30 VDC 2-Wire, 3-Wire for Pump module* and relay module* Pump Module* Tubing up to 30 m / 100 ft @ 05 l/min with 4 mm / 3/16 inner diameter Relay Module* Two alarm relays, one fault relay, SPDT, user programmable Rating 5 A 240 VAC, 5 A 24 VDC Ambient Conditions Transmitter only, for sensors see separate sensor data sheet Temperature -40 to +65 C / -40 to +150 F Pressure 700 to 1,300 hpa / 236 to 325 inch Hg Humidity 0 to 100 % RH, non condensing Enclosure GRP, IP 66/67, NEMA 4, M20 cable gland Size (H W D) 166 135 129 mm, 654" 532" 508" ft Weight Appro 900 g / 2 lbs SIL Level SIL 2 verified Approvals ATEX II 1G E ia IIC Ga T4/T6-40 C to +65/ +40 C II 3G E ic IIC Gc T4/T6-40 C to +65/ +40 C II M1 E ia I Ma -40 C to 65 C O2 measuring function for protection against eplosion (measurement of inertisation) IECE E ia IIC Ga T4/T6-40 C to +65/+40 C E ic IIC Gc T4/T6-40 C to +65/+40 C I M1 E ia I Ma -40 C to 65 C In accordance with IEC 60079-27, FISCO UL Class I, Div 1, Group A, B, C, D, Class II, Div 1, Group E, F, G CSA Class I, Div 1, Group A, B, C, D / E ia IIC T6/T4, -40 to 40/+65 C CE mark Electromagnetic compatibility (2004/108/ EEC) Low Voltage (Directive 2006/95/EC) HART is a registered trademark of the HART Communication Foundation LONWORKS is a registered trademark of the Echelon Corporation FOUNDATION fieldbus is a registered trademark of the Fieldbus Foundation *General purpose use only The transmitter does not have any approval, but the CE-mark when used with LON a pump or relay module Ordering Information Dräger Polytron 7000 with 4 to 20 ma output and Sensor Diagnostic Dongle 83 17 980

08 Dräger Polytron 7000 Ordering Information Dräger Polytron 7000 variations 4 to 20 ma HART Relay Pump 83 17 610 PROFIBUS PA FOUNDATION 83 17 636* 83 17 637* 83 17 638* 83 17 710 83 17 776* 83 17 777* 83 17 778* LON Relay Pump fieldbus H1 83 17 810* 83 17 816* 83 17 817* 83 17 818* 83 19 430 83 19 427* 83 19 436* 83 19 438* 83 19 440 Dräger Polytron Docking Station one required per transmitter 83 17 990 Modules Pump Module 83 17 350 Relay Module 83 17 360 Relay Connector 18 90 086 Software Dongles Data Dongle 83 17 618 Sensor Test Dongle 83 17 619 Sensor Diagnostic Dongle 83 17 860 Accessories Remote Sensor Adapter 83 17 275 Remote Cable and plug 5 m / 16 ft 83 17 270 Remote Cable and plug 15 m / 49 ft 83 17 998 Remote Cable and plug 30 m / 100 ft 83 17 999 Remote duct adapter 83 17 617 Duct Mounting Kit 83 17 150 Cable Entry Set M20, with cable gland and connector for multidrop 83 17 282 Calibration Adapter, electrochemical sensors 68 06 978 Pump Adapter for DrägerSensor AC L 83 17 976 Calibration Adapter, DrägerSensor AC L 68 09 380 Dräger GasVision, data display software 83 14 034 Dräger CC-Vision GDS, calibration and configuration software 68 11 989 83 19 428* 83 19 437* 83 19 439*

Dräger Polytron 7000 09 Ordering Information IR data cable, USB DIRA 83 17 409 PDA m515-e 83 17 995 Process Adapter RS EC, Stainless Steel 83 23 404

10 Dräger Polytron 7000 90 44 797 1602-1 HQ PP Subject to modifications 2016 Drägerwerk AG & Co KGaA Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status CORPORATE HEADQUARTERS REGION DACH REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fa +49 451 882 2080 info@draegercom Dräger Safety AG & Co KGaA Branch Office PO Bo 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fa +971 4 4294 699 contactuae@draegercom REGION EUROPE Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fa +49 451 882 2080 info@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fa +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL Complejo Business Park, V tower, 10th floor Panama City Tel +507 377-9100 Fa +507 377-9130 contactcsa@draegercom REGION NORTH AMERICA Draeger, Inc 3135 Quarry Road Telford, PA 18969 Tel +1 800 4DRAGER (+1 800 437 2437) Fa +1 215 723 5935 infousa@draegercom