Inspection Report: Cave City WWTP - Cypress Ln Lift Station, AFIN: , Permit #: AR FACILITY TYPE: 1 - Municipal

Similar documents
WATER DIVISION INSPECTION REPORT

WATER DIVISION INSPECTION REPORT

WATER DIVISION INSPECTION REPORT

Inspection Report: Berryville Collection System, AFIN: , Permit #: AR FACILITY TYPE: 1 - Municipal

All of the lift stations visited appeared to be clean and well maintained with working alarms and lights.

For additional information you may contact the Enforcement Branch by telephone at or by fax at

OPERATION & MAINTENANCE

1. Researchers are familiar with the location and contents of: The lab s Chemical Hygiene Plan YES NO

LIFT STATION INSPECTION & ASSESSMENT

RE: Quarterly Inspection conducted on September 6, 2017 AFIN Permit Number 0180-SG-WTX

LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES

OPERATION & MAINTENANCE

University of California, Davis Laboratory Self-Inspection Checklist

FOR THE PERIOD JANUARY 1, TO DECEMBER 31, GENERAL INFORMATION

City of Joshua 101 S. Main Joshua, Texas

INFLOW & INFILTRATION REPORT

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

Fats, Oils and Grease Program (FOG)

Resource, Support, Development, Inc. FIRE EVACUATION DRILL REPORT

USAutomatic Sprinkler Corporation

STAFF REPORT ACTION REQUIRED

FLORIDA INSTITUTE OF TECHNOLOGY DEPARTMENT OF CHEMISTRY SAFETY MANUAL

Program Introduction and Policy 1. Frequently Asked Questions 2. Device Maintenance..3. Best Management Practices...4

Access Controls for High Radiation Areas NISP-RP-05

Village of Sloan Smoke Testing September 2017

OHIO UNIVERSITY RADIATION SAFETY REVIEW

Temporary LPG Heat for Construction Sites Information Packet

Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet

North Liberty Fire Department Permit Application Temporary Storage & Use of LPG

Page 1 of 6. Machine Serial No. Model Pump Size PRELIMINARY INSPECTION. Service and Connections

168 Spotnap Road Charlottesville, VA Tel (434) Fax (434)

Laboratory Inspection Checklist

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

Keeping. Fats, Oils, and. Grease. Out of the Sewer

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

EMERGENCY INFORMATION

Guidelines for the Sanitary Sewer Evaluation Survey (SSES) Report PLAN A

OPERATION & MAINTENANCE

Inspection Records Schedule- Fire Extinguisher

WATERFRONT FACILITY COMPLIANCE BOOKLET

Department of Public Safety

RESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors

CONSOLIDATED EDISON CO. OF NEW YORK INC. 4 IRVING PLACE NEW YORK, N.Y DISTRIBUTION ENGINEERING CABLE SYSTEMS

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

Templates for Maintenance Documents

Joseph Florio, Commissioner of Pub. Works Tel

Stormwater Program Coordinator: Title: Office Phone #: Emergency Phone #: Public Notice Coordinator: Title: Office Phone #: Emergency Phone #:

South Davis Metro Fire Agency

(Inspector) Scott Ullrich Mailing Address (if Different from Business Location): Address. (FIRE) David Topping City State Zip

Advanced Protection Logic Lynx Touch & Lyric Series

If there are emergency situations they should be reported to Maintenance Department immediately.


MANUAL OF ENVIRONMENTAL HEALTH PROCEDURES

Inspection Report. Provided by: Super Inspection Pros. Inspector: Aaron Price. HI Phone:

SOUTHWEST RESEARCH INSTITUTE

Web Pages for Construction and Traveler Information Condition Reporting System 511 Phone Power. Data Processing and Response Formulation

Sanitation Checklist SANITATION CHECKLIST Month Year 1/9/2013. Inmate Living Areas Clean. Sewer Sys. Maint T.D.H. Inspection

SOUTH CAROLINA LIQUEFIED PETROLEUM GAS PROGRAM (LP-GAS)

LABORATORY INSPECTION CHECKLIST

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

NATIONAL ORGANIZATION SONS OF UNION VETERANS OF THE CIVIL WAR CIVIL WAR MEMORIAL ASSESSMENT FORM

CIVIL WAR MEMORIAL ASSESSMENT FORM

IS THERE MONEY AVAILABLE FOR WORK IN HISTORIC CEMETERIES? The AHC is not aware of any funding available for cemetery preservation or maintenance.

Attachment F. Campus Capital Needs Sales Surtax Funded Detail Report

APPLICATION PACKET & INFORMATION Templeton Community Services District

USER S MANUAL DN-2. Drain pump

Osceola County Department of Fire Rescue and Emergency Medical Services

WTAMU Academic Research Environmental Health and Safety (AR-EHS) Laboratory Inspection Checklist

Commercial Business Licensing Requirements

CONSTRUCTION CODES VARIANCE / MODIFICATION PROCEDURES

Note: Staff reports can be accessed at Special Permit Application No.

CIVIL WAR MEMORIAL ASSESSMENT FORM

I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

Developing Dam Operations & Maintenance Manuals

INSPECTION REPORT Nr IDD/S-09/922

A Guide to the Fire Safety Log Book For Small to Medium Business

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Photo 1: Upper Rock Creek Trash, east of Ogontz Ave. Map 1: Map of Upper Rock Creek with photos of conduit openings

SOLARPEAK SITE ASSESSMENT FORM. I. Solar Access Assessment

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

El Segundo Fire Department. Unified Program (UP) Form CONSOLIDATED CONTINGENCY PLAN I. FACILITY IDENTIFICATION

OPERATIONS & MAINTENANCE MANUAL FOR POST CONSTRUCTION MEASURES

Full Service Central Station Fire Alarm Listing Evaluation

Department Of Public Works: Internal Operations

Action Recommendation: Budget Impact:

CIVIL WAR MEMORIAL ASSESSMENT FORM

WORKPLACE EVALUATION CHECKLIST & REPORT

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

CHECKLIST FOR OBSERVATION MONITORING

SITE PLAN REVIEW APPLICATION

Raingardens in Clay and Shallow Bedrock. by Rusty Schmidt Washington Conservation District

STORMWATER FACILITIES OPERATION AND MAINTENANCE PLAN. Example Commercial Project. February 21, 2018

CIVIL WAR MEMORIAL ASSESSMENT FORM

PLANNED UNIT DEVELOPMENT APPLICATION

PLAN REVIEW CHECKLIST

From: Director, Community Planning, Scarborough District. Ward 40 Scarborough-Agincourt

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

A.C.E. Security Consultants House of Worship Checklist

Transcription:

FACILITY INFORMATION NAME: Cave City WWTP - Cypress Ln Lift Station LOCATION: Cypress Lane CITY: Cave City, AR RESPONSIBLE OFFICIAL NAME: / TITLE Jim Smith / Public Works Director COMPANY: City of Cave City MAILING ADDRESS: PO Box 69 CITY, STATE, ZIP: Cave City AR 725210069 PHONE & EXT: / FAX: 870-283-5563 / EMAIL: WATER DIVISION INSPECTION REPORT AFIN: 68-00015 PERMIT #: AR0022110 DATE: 6/24/2015 COUNTY: 68 Sharp PDS #: 085182 MEDIA: WN GPS LAT: 35.955988 LONG: -91.540132 LOCATION: Entrance FACILITY TYPE: 1 - Municipal FACILITY EVALUATION RATING: 3 - Satisfactory INSPECTION INFORMATION INSPECTOR ID#: 84022 S - State DATE(S): ENTRY TIME: EXIT TIME: 6/24/2015 10:30 14:30 FAYETTEVILLE SHALE RELATED: N INSPECTION TYPE: SSO/Collection System PERMIT EFFECTIVE DATE: 1/1/2014 PERMIT EXPIRATION DATE: 12/31/2018 FAYETTEVILLE SHALE VIOLATIONS: N INSPECTION PARTICIPANTS NAME/TITLE/PHONE/FAX/EMAIL/ETC.: Alton Stewart/Water Operator Cody Wallace/ADEQ District 10 Water Inspector CONTACTED DURING INSPECTION: Yes AREA EVALUATIONS (S=Satisfactory, M=Marginal, U=Unsatisfactory, N=Not Applicable/Evaluated) N PERMIT N FLOW MEASUREMENT N STORMWATER S RECORDS/REPORTS N LABORATORY N FACILITY SITE REVIEW S OPERATION & MAINTENANCE N EFFLUENT/RECEIVING WATER N SELF-MONITORING PROGRAM N SAMPLING N SLUDGE HANDLING/DISPOSAL N PRETREATMENT S OTHER: SSO SUMMARY OF FINDINGS No violations were noted during the inspection. Single lift station is in a remote location away from the public, but the Operator may wish to provide the public emergency contact information at lift station. GENERAL COMMENTS On Wed June 24, 2015, an inspection of the WWTP s collection system was conducted with the abovementioned inspection participants. The collection system consists of service lines (privately-owned), main lines with manholes, and a single lift station (Cypress Lane). Some parts of the City are gravity-fed directly to the WWTP. Mr. Stewart reported that no SSOs had occurred at the lift station; however, SSOs do occur at some of the City s manholes during heavy rain events. The collection system is mainly 45/45 ductile/pvc lines with 10% concrete, and I&I occurs during wet-weather. There was no evidence of any SSOs at the lift station at the time of the inspection. INSPECTOR S SIGNATURE: Kerri McCabe DATE: 7/13/2015 SUPERVISOR S SIGNATURE: Jason Bolenbaugh DATE: 7/13/2015 Inspection Report Page 1 of 6

COLLECTION SYSTEM INSPECTION AND OVERALL RATING PROVIDE A BRIEF DESCRIPTION OF THE COLLECTION SYSTEM: Service lines (privately-owned) -> main -> lift station -> WWTP POPULATION SERVED/NUMBER OF RESIDENTIAL AND COMMERCIAL CONNECTIONS: 769 residential, <30 commercial, and 1 industry FEET OF SEWER SYSTEM: UNKNOWN AGE OF SYSTEM: UNKNOWN DOES THE SYSTEM EXPERIENCE PROBLEMS DURING DRY OR WET WEATHER (EXPLAIN): I&I during wet-weather. IS THERE A SYSTEM IN PLACE FOR REPORTING SSOS TO ADEQ (DESCRIBE): Monthly reporting on DMR; 24-hr reporting for SSO Report ARE ALL SSOs REPORTED REGARDLESS OF SIZE: HAVE SSOs REACHED WATERS OF THE STATE (LIST DATE AND LOCATION OF EACH): PUMP STATIONS NUMBER OF PUMP STATIONS IN SYSTEM: ONE HOW OFTEN ARE PUMP STATIONS INSPECTED/MONITORED: ARE MAINTENANCE RECORDS AND/OR OPERATOR LOGS KEPT: ADEQUATE INVENTORY OF SPARE PARTS: Basic parts; rebuild NUMBER WITH BACKUP POWER: NONE TYPE OF REMOTE ELECTRONIC MONITORING USED (I.E. SCADA OR AUTO DIALERS): NO BRIEF SUMMARY OF EMERGENCY PROCEDURES: Call to AP&L, 2000-gal holding capacity, SSO Report, and clean area (remove solids and lime). NUMBER OF PUMP STATIONS VISITED DURING INSPECTION (SEE ATTACHED CHECKLISTS FOR EACH): ONE SATELLITE SYSTEMS DOES THE COLLECTION SYSTEM RECEIVE FLOW FROM SATELLITE SYSTEMS: NO TYPE(S) OF WASTE WATER RECEIVED: RESIDENTIAL COMMERCIAL INDUSTRIAL OTHER: BRIEFLY DESCRIBE THE SATELLITE SYSTEM: ANY KNOWN PROBLEMS WITH SATELLITE SYSTEM: NAME, ADDRESS AND PHONE NUMBER OF PERSON RESPONSIBLE FOR SATELLITE SYSTEM: Inspection Report Page 2 of 6

PUMP STATION VISIT (COMPLETE A SEPARATE CHECKLIST FOR EACH PUMP STATION VISITED) GENERAL INFORMATION AND OVERALL EVALUATION NAME AND/OR LOCATION OF PUMP STATION: Cypress Lane TYPE(S) OF WASTE WATER RECEIVED: RESIDENTIAL COMMERCIAL INDUSTRIAL OTHER: NUMBER OF PUMPS: TWO NUMBER AND SIZE OF PUMPS APPEARS ADEQUATE: NUMBER OPERATIONAL: TWO EVIDENCE OF RECENT OVERFLOWS OR HIGH LEVELS: Float system used (high/low). S M U NA GENERAL OPERATION AND MAINTENANCE CLEAN AND WELL MAINTAINED WITH MINIMAL STORAGE OF UNRELATED EQUIPMENT: GATES/DOORS/HATCHES/LIDS/ETC. LOCKED TO PREVENT UNAUTHORIZED ACCESS AND/OR TAMPERING: WET WELLS, SUMPS AND PITS ADEQUATELY COVERED, GRATED OR OTHERWISE PROTECTED: ELECTRICAL CONTROLS COVERS CONDUIT AND EQUIPMENT PROPERLY INSTALLED AND MAINTAINED: GUARDS AND SHIELDS IN PLACE AROUND MOVING EQUIPMENT (BELTS, PULLEYS, DRIVESHAFTS, ETC.): ADEQUATE VENTILATION TO PREVENT EXCESSIVE CONDENSATION AND/OR GASES AND FUMES: ADEQUATE LIGHTING FOR ROUTINE INSPECTION/MAINTENANCE: SEALS, VALVES AND PACKING ADEQUATELY MAINTAINED TO PREVENT LEAKS: MINIMAL ACCUMULATION OF GREASE AND SOLIDS IN WET WELLS: S M U NA BACKUP POWER AND ALARMS PROVISIONS FOR GENERATOR AND/OR EMERGENCY TRANSFER PUMP: AUDIBLE/VISUAL ALARM WITH EMERGENCY CONTACT INFORMATION POSTED: S M U NA SCADA SYSTEM (LIST PARAMETERS MONITORED): COMMENTS: No provisions for backup power; however, lift station has considerable holding capacity. No emergency contact info posted, but lift station is in remote area away from public (audio/visual alarms present). Inspection Report Page 3 of 6

Water Division Photographic Evidence Sheet Location: Cave City WWTP - Cypress Ln Lift Station Photographer: Cody Wallace Date: June 24, 2015 Time: 1204 Witness: Kerri McCabe Photo #: 1 Description: Cypress Lane Lift Station; secured with fence and lock; adequate ventilation. Photographer: Cody Wallace Date: June 24, 2015 Time: 1206 Witness: Kerri McCabe Photo #: 2 Description: Two pumps and both operational; note clean area. Inspection Report Page 4 of 6

Water Division Photographic Evidence Sheet Location: Cave City WWTP - Cypress Ln Lift Station Photographer: Cody Wallace Date: June 24, 2015 Time: 1206 Witness: Kerri McCabe Photo #: 3 Description: Control panel kept inside pump house away from elements. Photographer: Cody Wallace Date: June 24, 2015 Time: 1205 Witness: Kerri McCabe Photo #: 4 Description: Wet well with ventilation outside pump house. Inspection Report Page 5 of 6

Water Division Photographic Evidence Sheet Location: Cave City WWTP - Cypress Ln Lift Station Photographer: Cody Wallace Date: June 24, 2015 Time: 1209 Witness: Kerri McCabe Photo #: 5 Description: Wet well free of accumulated grease and excessive floatables. Figure 1. Google Earth image dated Nov 16, 2012 of the Cypress Lane Lift Station. Inspection Report Page 6 of 6