Mar PMWW01d. IGBT PIM Page 4. IGBT 6-pack/4-pack Page 1 IGBT High Power 6-pack Page 3. IGBT IPM Page 10. IGBT Discretes Page 12

Similar documents
Description of Functions

All Electric Servo Drive Injection Molding Machine

Vacuum Interrupters. Outstanding vacuum-related manufacturing techniques of MEIDEN has

EVERLIGHT ELECTRONICS. Company Profile LIGHTING FOREVER. A New Frontier in LED technology VER EL

Silane Coupling Agents. Combination of Organic and Inorganic Materials

Yoswit 0-10V / 1-10V / potentiometer / 10V PWM (3 in1 ) Constant Current Dimmer Driver

CERTIFICATE. Renesas Semiconductor Package & Test Solutions Co., Ltd. Oita Factory 4200 Idoda, Nakatsu-shi, Oita Japan

Chapter 7. Troubleshooting

EcoMet 30. Grinder-Polisher Systems. EcoMet 30 Semi-Automatic Single and Twin

CERTIFICATE. Scope: The design and manufacture of semiconductor devices.

Floriculture. A world wide business and international challenges.??-??-2012, Nico de Groot

SWITCH SOLUTIONS FOR LIGHTING APPLICATIONS.

SMD Rework Station TABLE OF CONTENTS

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Venetian blindstm with Intelligent Tilt Alignment

NaturaLINE The world s first natural refrigerant unit for container refrigeration.

MICROJET RECORDER (24-CHANNEL 180mm)

IWAKI HI-CERA PUMPS V

Y Series. Panic Exit Device. An ASSA ABLOY Group brand

CERTIFICATE. Scope: The design and manufacture of semiconductor devices.

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

Feed points. Optimize your material handling!

TSYS02S Digital Temperature Sensor

HEP Tech Co., Ltd. Company Profile

Application Note #451 Revision B June 2012

See it before it becomes a problem. Infrared Thermography for predictive maintenance

MTL1000 range of signal conditioners. For reliable, high quality process communications

This application note describes the introductory procedure of Renesas Peripheral Driver Library for RX families. 1. Overview... 2

Lab-Quality Results for Point-of-Care Testing

BUILD the clinic you ve always imagined.

Speedy Accuracy Maintainability CATALOG

RZ/A1H Group APPLICATION NOTE. Renesas Starter Kit Web Engine Demonstration for e 2 studio. Introduction. Target Device. Development environment

Football field lighting (Morocco) 500W LED Project Light

Low-Power CMOS ALARM IC with Horn Driver

Contents. Introduction. Introduction About This Report 1. Sustainability & Strategy. Social Respect for Human Rights and Diversity 15

Dräger Polytron 5100 EC Detection of toxic gases and vapors

EV Group. Solutions for Metrology

Unlocking the Potential of Blood TSCD II. Next-Generation Terumo Sterile Tubing Welder

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

2-Stage Indoor Condensing Unit for Refrigeration Applications (15-30 HP) Product catalogue

Dolphin Streetlight Telemanagement

MW9070B Optical Time Domain Reflectometer

1. Specifications Operation Confirmation Conditions Sample Code Reference Documents... 3

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2

The RCF range. Controllers and thermostats for fan-coil units

Doors & Gates sensors Product overview

Corporate Fact Sheet

GE Healthcare. Mixer M-925. Instructions

MICROJET RECORDER (180mm)

DeDusting Solutions for the plastics industry

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

nanoheat PAD Quick User Guide This appliance is approved, applicable to most countries in Europe and Asia but not the U.S. and Canada.

INTERNATIONAL STANDARD

Experts for Smart Sensor Solutions. Humidity and Temperature Liquid Flow Flow Meter Flow Controllers Differential Pressure

FHS-A9025S20. Picture:

Defence Solutions Land, Sea Air, Space


PROJECT: CUSTOMER: ENGINEER: DRAWING CONTENTS: WIRING

Information about the product Lexan FR60, FR63, FR65, FR66

Metronomis. city beautification luminaire. lighting solutions that really last

ReadyKart mobile processing station

E-T-A Get Smart With Your Systems

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Y Series. Escape Hardware. An ASSA ABLOY Group brand

FCP 320/FCH 320 Conventional Automatic Fire Detectors

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Signal Tower. See More, Do More!

This application note indicates the example of power supply circuit used Simple DC/DC for RZ/A series.

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

PQFP Handling Instructions

E Wired Intruder Detector

NORTH AMERICA JAE Shanghai Co., Ltd. JAE Europe, Ltd. JAE Electronics, Inc. JAE Taiwan, Ltd. JAE Tijuana, S.A. de C.V. OCEANIA

piflow Conveyor Customer Code

APA501. Series AMPSS. Heatsinks for Power Modules Technical Reference Manual. Series Highlights

TECHNICAL BULLETIN [ 1/9 ]

The SharpEye 40/40M (Multi IR) Flame Detection

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Bosch EVAX System - High-rise Applications

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

TEPZZ 9Z5549A T EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: F24F 1/06 ( ) F24F 1/46 (2011.

Thermal Shock Chamber TSE 11

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Unison Echo EchoConnect Station Power Supply

Mitsubishi Electric Cooling & Heating System VRF -

Panasonic Automation Products

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Dräger Polytron 8720 IR Detection of carbon dioxide

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Return loss measurement of fiber optic components

Owner's Manual. Voltage Converter. Reverse. 110V to 220V STEP UP. For International Power Connectivity Converts U.S. 110V to Foreign 220V

Two global companies, one solution.

INTRODUCTION. TATUNG (SHANGHAI) Co., Ltd. CQC ISO9001:2008 OHSAS Certificate: 00112Q28060RIM/3100

MICROJET RECORDER (180mm)

Application Note #407 Revision F March 2019

Automatic Lyrics Alignment for Cantonese Popular Music

SMD HOT TWEEZER. Instruction Manual

mtc001 Thermocouple Converter

Vacuum drying chambers. VD VDL series

Transcription:

FUJI Power Semiconductors IGBT Modules IGBT 6-pack/4-pack Page 1 IGBT High Power 6-pack Page 3 IGBT PIM Page 4 IGBT Standard 2-pack/1-pack Page 7 IGBT IPM Page 10 IGBT Discretes Page 12 Mar. 2009 PMWW01d

600V 1200V IGBT 6-pack/4-pack 1 13 1 5 9 2 6 10 16 15 14 3 7 11 4 8 12 17 10A 15A 35A Gen. 3, Planar-PT 6MBI10S-120 6MBI15S-120 6MBI25S-120 6MBI35S-120 6MBI50S-120 2 21 1 5 9 2 6 10 19 17 15 13 6MBI75S-060 6MBI100S-060 6MBI75S-120 6MBI100S-120 Standard 3 14(Gu) 13(Eu) 5, 6(u) 3 7 11 4 8 12 20 Not connected: 16, 18 14(Gv) 13(Ev) 5, 6(v) 14 21, 22(P) 4MBI75T-060 4MBI100T-060 16(Gx) 15(Ex) 16(Gy) 15(Ey) 23, 24(N) 4 14(Gu) 13(Eu) 5, 6(u) 14(Gv) 13(Ev) 5, 6(v) 21, 22(P) 1 200A 4MBI150T-060 4MBI200T-060 16(Gx) 15(Ex) 16(Gy) 15(Ey) 23, 24(N) 1

600V 1200V 1700V IGBT 6-pack 5 35A Gen. 6 6MBI75U2A-060 6MBI75VA-060-50 * 6MBI100VA-060-50 * Gen. 6 6MBI35U4A-120 6MBI50U4A-120 6MBI50VA-120-50 * 6MBI75U4A-120 6MBI75VA-120-50 * 6MBI100VA-120-50 * With NTC 6 7 30 16 31 17 32 18 1 5 9 19 20 2 6 10 27 24 21 28 25 22 29 26 23 3 7 11 4 8 12 33 13 34 14 35 15 1 180A 6MBI100U2B-060 6MBI150U2B-060 6MBI150VB-060-50 * 6MBI75VW-060-50 * 6MBI100VW-060-50 * 6MBI75U4B-120 6MBI100U4B-120 6MBI150U4B-120 6MBI100VB-120-50 * 6MBI150VB-120-50 * 6MBI180VB-120-50 * 6MBI50VW-120-50 * 6MBI75VW-120-50 * 6MBI100VW-120-50 * 6MBI100U4B-170 6MBI150U4B-170 45 M647 107.5 8 1 180A 6MBI150VX-060-50 * 6MBI100VX-120-50 * 6MBI150VX-120-50 * 6MBI180VX-120-50 * 62 M648 122 With shunts 9 6MBI75UC-120 6MBI100UC-120 * Under development 2

1200V 1700V IGBT 6-pack 10 2 6MBI225U4-120 6MBI225U4-170 High power 6-pack 4 6MBI300U4-120 6MBI450U4-120 6MBI300U4-170 6MBI450U4-170 3

600V 1200V IGBT PIM (Power Integrated Module) 11 1 2 3 Converter 21 23 7 22 8 Thermistor 9 20 18 16 19 17 15 14 13 12 11 24 Brake Chopper I n v e r t e r 5 4 6 10 10A 15A 30A 35A Planar-PT 7MBR30SA060 7MBR50SA060 Trench/ 7MBR30U2A060 7MBR50U2A060 7MBR10SA120 7MBR15SA120 7MBR25SA120 7MBR25UA120 7MBR35UA120 7MBR50UA120 PIM 12 1 2 3 21 7 22 8 Thermistor 9 20 18 16 19 17 15 14 13 12 11 4 5 6 35A 7MBR50SB060 7MBR75SB060 7MBR100SB060 7MBR75U2B060 7MBR100U2B060 7MBR35SB120 7MBR50SB120 7MBR35UB120 7MBR50UB120 7MBR75U4B120 7MBR100U4B120 23 24 10 Converter Brake Chopper I n v e r t e r 4

600V 1200V IGBT PIM (Power Integrated Module) Gen. 6 Gen. 6 13 7MBR25VM120-50 * 7MBR25VP120-50 * Thermistor 35A 7MBR35VM120-50 * 7MBR35VP120-50 * 45 M719 107.5 Converter Brake Chopper I n v e r t e r 7MBR50VP060-50 * 7MBR75VP060-50 * 7MBR50VM120-50 * 7MBR50VP120-50 * PIM 14 7MBR100VP060-50 * 7MBR50VN120-50 * 7MBR50VR120-50 * Thermistor 7MBR75VN120-50 * 7MBR75VR120-50 * 62 M720 122 Converter Brake Chopper I n v e r t e r 1 7MBR100VR060-50 * 7MBR150VR060-50 * 7MBR100VN120-50 * 7MBR100VR120-50 * 7MBR150VN120-50 * 7MBR150VR120-50 * In/Out terminal Layout 7MBR VM/VN -50 7MBR VP/VR -50 INPUT T Power Flow S Power Flow REC INV W R REC INV R S T U V INPUT OUTPUT OUTPUT U V W * Under development 5

600V 1200V IGBT PIM (Power Integrated Module) Gen. 6 Gen. 6 15 7MBR25VW120-50 * 7MBR25VY120-50 * Thermistor 35A 7MBR35VW120-50 * 7MBR35VY120-50 * 45 M721 107.5 Converter Brake Chopper I n v e r t e r 7MBR50VY060-50 * 7MBR75VY060-50 * 7MBR50VW120-50 * 7MBR50VY120-50 * PIM 16 7MBR100VY060-50 * 7MBR50VX120-50 * 7MBR50VZ120-50 * Thermistor 7MBR75VX120-50 * 7MBR75VZ120-50 * 62 M722 122 Converter Brake Chopper I n v e r t e r 1 7MBR100VZ060-50 * 7MBR150VZ060-50 * 7MBR100VX120-50 * 7MBR100VZ120-50 * In/Out terminal Layout 7MBR VW/VX -50 7MBR VY/VZ -50 INPUT T Power Flow S Power Flow REC INV W R REC INV R S T U V INPUT OUTPUT OUTPUT U V W * Under development 6

7 2-pack 1200V 600V 1700V 21 20 19 18 17 1 200A 1 200A 400A IGBT Standard 2-pack 1 200A 400A 1 200A 400A 1 200A 400A 2MBI75U4A-120 2MBI100U4A-120 2MBI150U4A-120 2MBI150U4B-120 2MBI200U4B-120 2MBI200UC-120 2MBI300UC-120 2MBI200U4H-120 2MBI150U4H-120 2MBI300U4H-120 2MBI400U4H-120 2MBI300U4D-120 2MBI200U4D-120 2MBI100U4H-170 2MBI150U4H-170 2MBI200U4H-170 2MBI300U4H-170 2MBI400U4H-170 2MBI75S-120 2MBI100SC-120 2MBI150SC-120 2MBI100S-120 2MBI150S-120 2MBI200S-120 2MBI200SB-120 2MBI150U2A-060 2MBI200U2A-060 2MBI300U2B-060 2MBI400U2B-060 M249

600V 1200V 1700V IGBT Standard 2-pack 14 22 62 150 G1 E1 G2 E2 C P N OUT 2 4 600A Gen. 6 2MBI225U4N-120-50 2MBI225VN-120-50 * 2MBI300U4N-120-50 2MBI300VN-120-50 * 2MBI450U4N-120-50 2MBI450VN-120-50 * 2MBI600VN-120-50 * 2MBI225U4N-170-50 2MBI300U4N-170-50 2MBI450U4N-170-50 2-pack 15 23 14 24 62 150 G1 E1 G2 E2 C P N OUT 2 4 600A 4 600A 2MBI600U2E-060 2MBI300S-120 2MBI225U4J-120-50 2MBI300U4J-120-50 2MBI450U4J-120-50 2MBI300U4E-120 2MBI450U4E-120 2MBI225VJ-120-50 * 2MBI300VJ-120-50 * 2MBI450VJ-120-50 * 2MBI600VJ-120-50 * M238/247 15 25 130 140 38.5 E1 G1 C1 E1 C1 C2 E2 C2 G2 E2 600A 800A 1200A 2MBI600U4G-120 2MBI800U4G-120 2MBI1200U4G-120 2MBI600U4G-170 2MBI800U4G-170 2MBI1200U4G-170 * Under development 8

1200V 1700V IGBT Standard 1-pack 26 200A 400A 600A 1MBI200S-120 1MBI300S-120 1MBI400S-120 1MBI300U4-120 1MBI400U4-120 1MBI600U4-120 27 600A 800A 1MBI600S-120 1MBI600U4B-120 1MBI800U4B-120 1-pack 28 130 140 C C C 1200A 1600A 1MBI1200U4C-120 1MBI1600U4C-120 1MBI1200U4C-170 1MBI1600U4C-170 G 38.5 E E E 29 190 140 C C C C 2400A 3600A 1MBI2400U4D-120 1MBI3600U4D-120 1MBI2400U4D-170 1MBI3600U4D-170 38.5 G E E E E 9

IGBT IPM (Intelligent Power Module) Without With Without With Without With 30 31 32 33 34 70 100.5 Alarm Drive and protection chip Alarm Tj-sensor on-chip for efficient over-temperature protection -sensor on-chip for efficient overcurrent protection TC-Sensor IGBT chip Alarm Alarm Alarm Tj -Sensor -Sensor 15A 20A 30A 1 1 1 200A 1 200A Gen. 3 Planar-PT 6MBP15RH060 6MBP20RH060 6MBP30RH060 600V 6MBP50RA060 6MBP50RTB060 6MBP75RA060 6MBP75RTB060 6MBP100RA060 6MBP100RTB060 6MBP150RA060 6MBP150RTB060 7MBP50RA060 7MBP75RA060 7MBP100RA060 7MBP150RA060 6MBP200RA060 6MBP300RA060 7MBP200RA060 7MBP300RA060 6MBP20RTA060* 7MBP50RTB060 7MBP75RTB060 7MBP100RTB060 7MBP150RTB060 6MBP15RA120 * 7MBP25RSB120 6MBP25RA120 6MBP50RA120 6MBP75RA120 7MBP25RA120 7MBP50RA120 7MBP75RA120 6MBP100RA120 6MBP150RA120 7MBP100RA120 7MBP150RA120 1200V Planar-FS 6MBP25RU2A120 6MBP50RU2A120 6MBP75RU2A120 7MBP25RU2A120 7MBP50RU2A120 7MBP75RU2A120 10 * The package outline is. 31

Tj-sensor on-chip for efficient over-temperature protection Without 35 Alarm With upper alarm output Drive and protection chip IGBT IPM (Intelligent Power Module) Alarm -sensor on-chip for efficient overcurrent protection TC-Sensor IGBT chip Alarm Alarm Alarm Tj -Sensor -Sensor 1 600V 6MBP50RTJ060 6MBP75RTJ060 6MBP100RTJ060 6MBP150RTJ060 1200V 6MBP25RJ120 6MBP50RJ120 6MBP75RJ120 With Without 36 With upper alarm output Alarm Alarm TC-Sensor Alarm Alarm Alarm Tj -Sensor -Sensor Alarm Alarm Alarm Tj -Sensor -Sensor 1 1 7MBP50RTJ060 7MBP75RTJ060 7MBP100RTJ060 7MBP150RTJ060 6MBP50TEA060 6MBP75TEA060 6MBP100TEA060 6MBP150TEA060 7MBP25RJ120 7MBP50RJ120 7MBP75RJ120 6MBP25TEA120 6MBP50TEA120 6MBP75TEA120 With Alarm Alarm Alarm Alarm Tj -Sensor -Sensor 1 7MBP50TEA060 7MBP75TEA060 7MBP100TEA060 7MBP150TEA060 7MBP25TEA120 7MBP50TEA120 7MBP75TEA120 11

600V 1200V TO-3PL TO-247 TO-3P TO-220AB T-pack(S) 39 40 41 38 37 12 SMD IGBT Discretes 5A 10A 2.5A 5A 10A 15A 30A 30A 15A 2.5A 5A 8A 10A 15A 20A 30A Planar-PT Planar-PT 1MBG05D-060 1MBG10D-060 1MBC05D-060 1MBC10D-060 1MB15D-060 1MB20D-060 1MBK50D-060S 1MBK30D-060S 1MBH30D-060 1MBH50D-060 1MBC05-060 1MBC10-060 1MBC15-060 1MB20-060 1MB30-060 1MBH50-060 1MB03D-120 1MB05D-120 1MB08D-120 1MB10D-120 1MBH15D-120 1MBH25D-120 1MBC03-120 1MB05-120 1MB08-120 1MB10-120 1MBH15-120 1MBH25-120 1MBH75D-060S 1MBH50D-060S

1 2 3 Package Outlines 4 5 6-pack with NTC 6 6-pack with NTC 7 M712 M647 8 9 6-pack with shunts 10 11 M648 13

12 13 14 M719 M720 Package Outlines 15 16 17 18 M721 M722 19 20 21 22 108 93 4- ø6.5 28 28 150 137 110 62 48 C2E1 E2 C1 G2 E2 E1 G1 6 6 17 P N 22 50 62 25 25 25 4- ø5.5 94.5 ±0.3 4-M5 30 6 6.5 17 20.5 14

23 24 25 150 ±1 137 110 ±0.3 ±0.3 Package Outlines 94.5 ±0.3 4- ø5.5 26 27 28 29 30 31 32 33 40 53 130 ±1 114 55.2 29.5 40 57 6- ø7 M8 15 6.5 17±0.5 23 ±1 22 ±0.3 50 ±0.3 62 ±1 M4 38±0.5 28 10 140 124 30 15 ±1 14 20 11.5 35 20 5 16 18 8-ø7 20 40 15 20 130 ±1 114 61.5 18 29.5 M4 41.25 79.4 190 171 61.5 57 13 20.25 61.5 M8 29.5 38 ±0.5 28 10 45.2 140 ±1 124 40 20 M8 M4 6- ø7 38±0.5 28 10 45.2 20 40 124 140 20 40 15 20 ±1 10.55 10.35 48.8 (8) 2 (5) 2 70 ±1 ±1 60 ±0.3 2-ø4.5 (22) 46.5 (9.5) (1.55) 10 ±0.5 18±0.5 50.8 ±0.8 4-ø4.5 70 ±1 58.5 ±0.5 18 ±0.5 12.4 ±0.5 88.5 ±0.5 100.5 ±1

34 35 36 Package Outlines 37 T-pack (S) 38 TO-220AB 39 TO-3P 40 TO-247 41 TO-3PL 42 43 Ø 3.2 20.5 max. 5 6 20 min. 26.0 2.5 5.45 G C E 5.45 3.0 16

Semiconductors Group http://www.fujielectric.com/device/semi Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, JAPAN Tel: +81-3-5435-7152 Fuji Electric Device TechnoIogy Hong Kong Co., Limited Unit 227-230, 2nd Floor, No.1 Science Park West Avenue, Hong Kong Science Park, Shatin, N.T., Hong Kong. Tel: +852-2664-8699 Fuji Electric Device Technology America, Inc 240 Circle Drive North Piscataway, NJ 08854 Tel: +1-972-733-1700 Fuji Electric Device Technology Europe GmbH Goethering 58, 63067 Offenbach, am Main, F.R. GERMANY Tel: +49-69-6690290 Fuji Electric Taiwan Co., Ltd. 9F-1, No. 111, Sung Chiang Road, Taipei, TAIWAN Tel: +886-2-2515-1850 Fuji Electric Singapore Private Ltd. 133 New Bridge Road #17-01/02 Chinatown Point, SINGAPORE 059413 Tel: +65-6535-8998 Information in this catalog subject to change without notice. Printed in Japan 2009-3 L6 FIS