Each heater has slightly different operational characteristics

Similar documents
Thermo 230 / 231 / 300 / 301 / Troubleshooting

FURNACE OPERATION OVERVIEW

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

VAL6 EPX. Maintenance Manual

Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

D3LC compact Air Heater. Espar. Installation Troubleshooting & Parts Manual. D3LC compact

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

PORTABLE ENGINE HEATER AND EXTERNAL BATTERY CHARGER. Specifications: Benefits: IN: NC:

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING


KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

T-Series Air Conditioner T53 Model

SECTION AUXILIARY HEATER

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T20 Model

Trouble Shooting Guide PWA, 3-phase (D10571)

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

USER S INFORMATION MANUAL

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

ML180UH SERIES GAS FURNACE WARNING WARNING

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

AHE S -12 VDC AHE S - 24 VDC

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

SAFIRE 2000A FUEL OIL HEATER INSTALLATION, OPERATION AND MAINTENANCE

AGA COOKERS MODELS OC,OCB,OE,GC,GCB USING

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

SNUGGER SNUGGER AIR HEATER AIR SNUGGER USA Technical description. Installation instructions. Operating instructions

FOR RAYBURN COOKERS MODELS OF7/G7 & USING THE SNUGHOME PRESSURE JET CONVERSION. ISSUE No September Snughome Cookers Ltd.

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PAA, 1-phase (D3731)

EL195UHE SERIES GAS FURNACE WARNING WARNING

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

WARNING FIRE OR EXPLOSION HAZARD.

Gallery Electric Fireplaces

AIR-HEATER FOR VEHICLES

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Trouble Shooting Guide FAA, 3-phase (D3631)

WARNING FIRE OR EXPLOSION HAZARD.

Warranty Manual. Espar Products, Inc. Tel: Fax: QSF-60 Rev. 7

BlueHeat Coolant Heater

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

INSTALLATION AND OPERATION INSTRUCTIONS FOR

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Forced air mobile diesel heating systems.

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

This document was created with FrameMaker 4.0.4

Service Manual Model 3163

COR'IAIR HEATER CONTENTS. SERlJICIN8. the PART II DESCRIPTION AND OPERATION

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

USER S INFORMATION MANUAL (2,4)SG13B

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Installation, Operation and Service Manual

Commercial Maintenance Agreement (CMA) Benefits

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

IMPORTANT INSTRUCTIONS

Repair instructions A WORLD OF COMFORT. Spare parts list. The repair instructions are valid for the following

Hydronic D5 (Chevy Duramax Application)

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

EL296UHV SERIES GAS FURNACE WARNING WARNING

abt W Lamp Paraffine Oil n. 0,125 l/h 12 V = (11-14,5 V) 220 x 285 x 115 mm

Technical

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Test/Function Wrinkle release. Display list of diagnostic codes. Then press Temperature (^) - 13 Key. To sequence thru the diagnostic and help codes.

XIII Troubleshooting

PARTS & SERVICE MANUAL

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Quest Power Electric Heat EHS 31 Pro

ELECTRIC FIREPLACE OWNER S MANUAL

EL195DFE SERIES GAS FURNACE WARNING

1. GENERAL SAFETY RULES

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

HOME OWNER S INFORMATION Induced Combustion Gas Furnace

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

Transcription:

NOTE, YOU MAY WANT TO PRINT THIS GUIDE TO ASSIST YOU IN TROUBLE SHOOTING New information regarding the Ultra Low Sulfur Diesel Fuel Heater Trouble Shooting Guide Customer Name Phone Step 1. Basic Information on unit: Each heater has slightly different operational characteristics MODEL NUMBER (D8L etc.) SERIES NUMBER (251470GM etc.) SERIAL NUMBER USAGE (LIVE ABOARD etc.) AGE (& TOTAL HOURS if equipped) PREVIOUS SERVICE DATE'S AGE OF DIESEL FUEL Step 2. Basic information regarding the failure or problem. This information is required to pin point the problem area. 1. What does the heater do when the switch (thermostat) is turned on? (Example - fan runs - glow plug operates - fuel metering pump is ticking - color of exhaust smoke) 2. If the heater turns off automatically, how many minutes (or seconds) does it take? 3. If the heater turns off automatically, does any of the following occur? A. Exhaust smoke, Color, B. Is the fuel pump ticking?, Is The ticking normal or louder than normal? C. Is the glow plug getting hot?, D. Does the heater fan sound normal?

4. If the heater ignites, how many seconds does it take, from the moment you turn on the heater until the glow plug turns off? 5. If the heater ignites. Does the heater smoke?. If yes how long does it take for the smoking to clear? 6. How long does the heaters blower continue to run after you turn the heater off?. 7. During the cool down period, does the heater smoke heavily out the exhaust? 8. After the heater shuts down, does the heater smoke out of the combustion air intake? 9. Other clues. STEP 3. Determine from the information you have been able to gather the basic area of the problem. Heater does nothing - (Nothing means nothing, no fan, no fuel, no glow plug - NO NOTHING) Heater tries to ignite but fails (Tries to ignite means the motor, fuel pump and glow plug operate) Heater ignites, but turns off when the glow plug turns off. Heater ignites, glow plug goes off, but heater shuts down before thermostat is satisfied. Heater ignites, heater appears to operate normal, however the exhaust is smoking abnormally on start-up and shut down. Heater appears to operate normally, except the glow plug life is shorter than it has been. Heater appears to operate normally, except a fuse or breaker blows or trips for no apparent reason. Always remember - There are three elements required to make a fire FUEL + OXYGEN + A HEAT SOURCE for ignition NO FUEL = NO SMOKE WHAT IS MISSING? LOW FUEL = WHITE SMOKE = LOW CO2 HIGH AIR to FUEL HIGH FUEL = DARK SMOKE = HIGH CO2 LOW AIR to FUEL Step 4. Now that you have determined the basic area of the problem you can work with more detail.

IF THE HEATER IS EQUIPPED WITH DIAGNOSTICS, DETERMINE THE DIAGNOSTIC CODE. All of the newer Espar heaters have self diagnostic features. A few models have the diagnostic signal always on, some models you will need to activate the diagnostics by pressing and holding a push button switch for about 3 seconds to activate and some models the diagnostic information must be retrieved by an Authorized Espar service center with special testing equipment. Heater does nothing. 1. Check & verify that there is power at the heater with a voltmeter or test light. Check fuses and for loose or corroded connections. 2. Make sure that all switches & thermostats are on. 3. Check to make sure there is power coming back from thermostat. 4. Some models do nothing if the glow plug is "open" or disconnected. 5. Some models do nothing if the fuel metering pump circuit is "open" or disconnected. (Overheat fuse is in this circuit also) 6. Some models do nothing if the motor fuse in the controller is open or motor is defective. (such as the older D4L, D7L and D12L Models) 7. Defective control box Heater runs 5 sec. - then stops 1. Open overheat sensor (safety thermal cutout switch) or blown overheat fuse 2. Open glow plug circuit 3. Defective control box Heater runs 16-30 seconds & stops 1. Low voltage at heater control box power input terminals. Check batteries and all connections, fuses or breakers etc. Note: All voltage tests must be taken when heater is in the start mode with the glow plug operating. Tries to Ignite for 3 min. 1. Check the glow plug and its electrical connections. 2. Measure the voltage at the heater while glow plug is operating. 3. Measure the voltage at the glow plug/pin while the plug is operating. 4. Check the fuel filters). 5. Is the fuel metering pump "ticking" (check overheat fuse) Check for defective pulse source. 6. Disconnect fuel line at heater, is there fuel coming out? 7. Is the exhaust pipe obstructed? Is drain coil open? 8. Is the combustion air intake hose damaged & restricting the combustion air?

9. Is the motor running slow? 10. Is the combustion air solenoid operating (Older D4L, D7L and D12L) 11. If this heater has been is severe service, such as live aboard or used as primary dock side heat, or has been installed for 2 to 3 years, the heater may require a "burner service". Heater ignites, but shuts off at 3 minutes. 1. Check the heater temperature switch (thermo-switch). Note some models the switch is normally open & some are normally closed. 2. Note: many of the newer models use 2-90 second start attempts with a purge period in between, this will result in a longer than 3 minute attempt to start. For these heaters the symptom is that the heater shuts off after the second attempt to start. Heater fan runs, no glow plug or fuel. 1. Check the heater temperature switch (thermo-switch). It may be in the "hot" position - Heater is still in cool down. 2. Defective control box Ignites & runs OK, but stops before thermostat switches off 1. Check the fuel filters. 2. Check fuel pumps). 3. Clean the thermostat contacts (excludes electronic thermostats). 4. Check for loose wiring connections. 5. Check for high voltage. Measure voltage when it shuts off. 6. Check for low voltage. Measure voltage when it shuts off. 7. Is this a problem only when the engine in running? Ignites & runs normal, - excessive smoking starting and stopping 1. Normally a symptom of clogged or partially clogged atomizer in models D3L, D7L, D12L AND D12W. Clean or replace atomizer. 2. Other models may require burner service to remove any carbon deposits. 3. White smoke = unburned fuel. Heater runs OK, Blower runs over 3-4 min. on cool down 1. Check temperature switch (thermo-switch)

2. Sticking relay in control box. Glow plug is failing more often than normal 1. Check glow plug voltage regulator, if equipped. 2. Check glow plug electrical connections. 3. Check & clean glow plug socket, clean or replace glow plug socket screen. 4. Burner may require service. 5. Check fuel filters & fuel flow. 6. Check burner efficiency by measuring CO2 and exhaust smoke content. 7. Glow plug voltage too high or too low. 8. If coil is collapsed but clean, look for loose elect connections, fuel filters (low fuel), high or low voltage. 9. If plug has excessive carbon buildup, look for a dirty burner, dirty glow plug socket and - or screen, proper fuel quantity and measure CO2 10. Check air supply to glow plug for blockage. 11. Make sure glow plug is tightened enough to seal completely Heater operates OK, but fuse or breakers blow for no apparent cause 1. Over heat fuse or breaker. Make sure there has been no damage to the ducting, too many registers closed, something sucked into the intake. Measure air temperature out of the heater (at 18" from discharge) 2. Main power or motor fuse. Inspect the fuse holder, if there is any corrosion or signs of heating, replace the fuse holder. Use only approved fuse holders. Heater smokes all the time. 1. Verify the motor rpm, it may be too slow. 2. Verify that the exhaust does not have any restrictions. If there is a deposit build up inside the pipe, it requires cleaning. 3. Measure the fuel quantity, it may be too high. 4. Measure the burner efficiency (CO2) Note: = Only applies to certain models. This guide is designed to help you analyze and do very basic troubleshooting only. Many procedures will require additional service manuals, test equipment and specialized or advanced training. West Coast Authorized Espar Dealer List New information regarding the Ultra Low Sulfur Diesel Fuel ESPAR HEATER MODELS

ESPAR HEATER MODELS Request for Service Information You will need to select the heater model and series number. Heater model examples are "D1L, D1LC, D1LCC". The series number will start with 25 for all diesel heaters and 20 for gasoline vehicle heaters. Such as 25-1380- XX. the most important number is the series number. As you can see there have been several models with the basic designation of "D1L" which means, the heater operates on diesel fuel (D), the heat output is approximately 1,000 to 1,800 watts(1) and the method of delivering the heat is hot air (L). When the heater delivers the heat via hot water the letter changes to (W) There may be additional letters after the "L" or "W", these indicate the configuration of the heater. There may be additional numbers in the series number, these numbers are not required. Select "Model and Series number (D1L = Model - 25-1380 = Series) D1L #25-1380 Enter description of information you require. If you require assistance in the repair or troubleshooting please put in as much information as you can. "It does not work" is not acceptable and the request will be ignored. Information submitted by: (*= required field) Name* Address City* State* Zip E-mail*