NetworX Series NX-870E Fire Supervision Module Installation and Startup

Similar documents
NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

INSTALLATION MANUAL PC25OO

Installation Instructions

NetworX Series NX-4V2 Control Panel Installation and Startup

Control/Communicator Installation Manual

PC4020 v3.2 Installation Manual DLS-3 v1.3

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

NX-4V2 Control Panel Installation Instructions

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Model 17A00 Expansion Enclosure

NetworX NX-548E Receiver Installation Instructions

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

D2412 Control / Communicator Installation Manual

PC4020 v3.2 Instruction Manual

Installation Guide. Control/Communicator

GE Security Fire & Life Safety F-DACT(F) Digital Alarm Communicator Transmitter Installation Sheet

PROGRAMMING WORKSHEETS

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

Installation Manual Premier 412/816/832. Issue 10

Installation Instructions

NX-148 LCD CODE PAD TABLE OF CONTENTS

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

NetworX NX-8V2. LED Keypad User Manual

THE OPERATOR ACCESSING YOUR SYSTEM 3 FUNCTIONS OF THE "OPERATOR" 4 PROGRAMMING/CHANGING ACCESS CODES 13 ACTIVATING EMERGENCY ALARMS 14

NETWORX TM. User manual NX-4

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

SIGA-CC1 Single Input Signal Module Installation Sheet

MR-2602 Two Zone Fire Alarm Control Panel

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

CONNECTIONS OF CUSTOMER-PROVIDED PREMISES EQUIPMENT. CONTENTS Page

NetworX Series NX-1500E LED Keypad

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HILLS Series LCD Code Pad User Manual

EVO192 v3.0 Fire and Burglary What s New

INSTALLATION INSTRUCTIONS TALKBACK MODULE

AVS Audio Verification System

Using your LED Plus keypad

About Your Security System. General System Operation. Fire Detection. Testing. Monitoring

Instruction Manual W A R N I N G

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

D7212 Control/Communicator Operation and Installation Manual

R E G E N C Y Model 2615 Control/Communicator. Installation Manual. Part Number , Rev. A Initial Release Date: March 1995 Revised August 1998

DS7400Xi Addressable Control/ Communicator

Series. NX-4-EUR Control Panel. Installation manual

Supervised Security System Owner's Guide

System Introduction. 1.1 Specifications S E C T I O N 1

User's Manual 5120XM N8031 6/96

XR10/XR20 Command Processor Panels Installation Guide

Print Specification. Publication. Instructions. Specific requirements. General requirements

Addressable Fire Alarm Control Panel

SECURITY SYSTEM NOTES

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

Operation and Installation Guide. Fire Alarm Control Panel

4100U City and Relay Cards Installation Instructions

HARDwired Installation/ Owner s Manual

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

INSTRUCTION MANUAL PC255O

System Introduction. 1.1 Specifications

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Simon XTi Quick Operation Guide

Tek-ENTRY Telephone Entry System

INSTRUCTION MANUAL PC255O

KT-100 Door Controller

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

Resolution Compatibles Flex GSM IGM is a GSM cellular device that provides

INSTALLATION GUIDE XTLN-WIFI PANEL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

TELGUARD TG-4 CDMA. Revised August 14, PROPRIETARY INFORMATION For use by TELGUARD customers only. Distribution to others strictly prohibited.

Panic. Part Number SYSTEMS, Inc.

Digital Alarm Communicator/Transmitter. Document # /07/00 Rev. P/N 50921:C ECN

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

Concord 4 Series Security Systems

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

RELEASE DEVICE CONTROLS

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Instruction Manual PC55O. With PC5OORK Keypad

Booster Power Supply Manual

System Manual W A R N I N G. PC6O1O Software Version 2.1

Computer Room Guard Model VM Manual and Installation Instructions

TABLE OF CONTENTS TABLE OF CONTENTS 1

R A D I O N I C S. D7212 Control/Communicator Operation and Installation Manual B 2/ Radionics

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

INSTALLATION MANUAL PC15OO

Concord 5 TouchScreen Installation Sheet

Model 4880 Status Output Display Module Manual

SECTION FIRE ALARM SYSTEMS

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

Digital Alarm Communicator/Transmitter 411UD. Document # /07/00 Rev. P/N 50759:C ECN

RMS/RPX Reader. User Manual

Transcription:

NetworX Series NX-870E Fire Supervision Module Installation and Startup

2002 GE Interlogix All rights reserved. Printed in the USA. NetworX is a trademark of GE Interlogix. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met during installation, operation, and maintenance. If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser s purpose, the matter should be referred to GE Interlogix, Gladewater, Texas, USA. This document contains proprietary information of GE Interlogix, USA and is furnished to its customer solely to assist that customer in the installation, testing, operations, and/or maintenance of the equipment described. This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Interlogix. Please refer to the current GE Interlogix product catalog for detailed warranty information. TABLE OF CONTENTS I. GENERAL DESCRIPTION...3 II. TERMINAL DESCRIPTIONS...3 III. WIRING THE MODULE...4 IV. INSTALLING THE MODULE...5 V. ENROLLING THE MODULE...5 VI. ENCLOSURE DIAGRAM...5 VII. LOCAL TELEPHONE PANY INTERFACE...6 VIII. UNDERWRITERS LABORATORIES...7 IX. ORDERING INFORMATION...7 X. SPECIFICATIONS...8 2 NX-870E Fire Supervision

I. GENERAL DESCRIPTION The NX-870E Fire Supervision module is a microprocessor-controlled expansion module that provides the features necessary in most fire system installations. The module facilitates the connection of two (2) phone lines to the NX-8-CF control panel. It provides the necessary monitoring and switching of these phone lines for a quick and easy addition to those systems that require the additional security of a second phone line. The fire supervision module also provides a separate fully supervised bell output that can be used to power fire annunciators separate from burglary annunciators. Additionally, it provides full supervision of the earth ground connection required by most fire installation standards. II. TERMINAL DESCRIPTIONS Terminal Line 1 R Line 1 T Line 1 R1 Line 1 T1 Line 2 R Line 2 T Line 2 R1 Line 2 T1 POS GND DATA BELL + BELL PIPE EARTH Ring terminal for the incoming primary phone line. Tip terminal for the incoming primary phone line. Description Ring terminal for the building phones connected to the primary phone line. This terminal, along with T1, feeds the incoming primary phone line to the building phones. Tip terminal for the building phones on the primary phone line. This terminal, along with R1, feeds the incoming primary phone line to the building phones. The primary phone line will always be connected to the control when it is available. Ring terminal for the incoming secondary phone line. Tip terminal for the incoming secondary phone line. Ring terminal for the building phones connected to the secondary phone line. This terminal, along with T1, feeds the incoming secondary phone line to the building phones. Tip terminal for the building phones on the secondary phone line. This terminal, along with R1, feeds the incoming secondary phone line to the building phones. The secondary phone line will only be connected to the control if the primary is not available. A failure of the secondary phone line will be reported to the control even if it is not being used by the control. Connect to control panel BELL+ terminal. This terminal supplies power to the Fire Supervision board. With the NX-870E connected, the BELL terminals on the NX-8-CF cannot be used as a speaker or siren output. Connect to the control panel MON terminal. This terminal supplies the common side of the power to the Fire Supervision board. Connect to the control panel DATA terminal. This terminal is the data-signaling terminal to all the devices on the buss. Connect the positive side of fire warning devices to this terminal. For full supervision of these devices connect according to the diagram on page 4. Connect the negative side of fire warning devices to this terminal. For full supervision of these devices connect according to the diagram on page 4. Connect this terminal to the cold water pipe ground. This terminal provides supervision of the earth ground connection to the system. Connect to a cold water pipe ground or rod driven into the ground. When using the Fire Supervision module, it is important not to connect a separate earth ground to the earth ground terminal of the control panel. This will be interpreted by the control as a ground fault. Ground is provided to the control panel via the GND terminal of the power connection. 3 NX-870E Fire Supervision Module

III. WIRING THE MODULE LED4 W4 NX-8-CF FIRE PANEL LED3 LED1 THESE LEDS ARE FOR PROPER CIRCUIT OPERATION ONLY. W3 LED2 1 2 3 4 1 AUXOUT NX-870E FIRE SUPERVISION MODULE 2 3 4 5 6 7 8 ZONES THIS CONNECTION MUST BE MADE WITH 12 GAUGE WIRE. SPARE EARTH PIPE BELL- DATA BELL+ BELL- AUX PRW+ SMOKE+ POS KEYPAD BELL+ AC AC EARTH TO ADDITIONAL KEYPADS AND EXPANSION DEVICES. MAX 8 KEYPADS PER PARTITION. MAX 24 KEYPADS PER SYSTEM. T1 T R R1 THE PANEL T1 AND R1 TERMINALS MUST NOT BE USED WITH THE NX870. DATA GND POS THIS CONNECTION MUST BE MADE WITH 12 GAUGE WIRE. T1 T R LINE2 BROWN GREEN RED LIGHTNING PROTECTION THE CONTROL PANEL MUST BE EARTH GROUNDED FOR LIGHTNING PROTECTION TO WORK EFFECTIVELY. THE GROUND CONNECTION SHOULD BE TIED TO A VERIFIED COLD WATER PIPE OR A DEDICATED METAL ROD 6 TO 10 LONG. USE MINIMUM 14 GAUGE WIRE. R1 GREY T R T1 T R R1 LINE1 PANEL BROWN GREEN RED GREY USE CADDX PART #EOL33 SUPERVISED 3.3K EOL + - USE CADDX PART #EOL-D5400 U.L. INSTALLATIONS The Class 2, Class 3, and power-limited fire alarm circuits must be installed using FPL, FPLP, FPLR, CL3, CL3R,or CL3P, or substitute cable permitted by National Electrical Code ANSI/NFPA 70 and the Class 2, Class 3 and power-limited fire alarm circuit conductors extending beyond the cable jacket must be separated a minimum of ¼ inch or by non- conductive tubing or non-conductive barrier from all other conductors. TO TELCO NETWORK RJ31X SUPERVISED TO TELCO NETWORK RJ31X CURRENT LIMITED TO 12V, 600MA MAXIMUM SPECIAL APPLICATIONS: PATIBLE FIRE ALARM BELL WHEELOCK MODELS # NS - 1215W, NS-121575W THE BELL OUTPUT IS VOLTAGE ONLY, AND IS PULSED DURING A FIRE ALARM. THE BELL OUTPUT ON THE PANEL BEES A 2.5AMP CURRENT LIMITED VOLTAGE OUTPUT AND MAY NOT BE USED TO POWER ADDITIONAL EQUIPMENT. 4 NX-870E Fire Supervision

IV. INSTALLING THE MODULE The Fire Supervision module can be installed in a simple two-step process. First, wire the NX-870E according to the wiring diagram on page 4. Second, use the procedure below to enroll the Fire Supervision module into the NX-8-CF. All functions associated with the Fire Supervision module will be performed automatically. No programming is required beyond the enrolling process. V. ENROLLING THE MODULE For supervision purposes, the NX-8-CF has the ability to automatically find and store in its memory, the presence of all keypads, zone expanders, wireless receivers, and any other module connected to the data terminal. This allows these modules to be supervised by the control panel. To enroll the modules, enter the Program Mode of the NX-8-CF control panel as follows. To enter the Program Mode, press [r]-[8]. At this time, the five function LEDs (Stay, Chime, Exit, Bypass, & Cancel) will begin to flash. Next, enter the "Go To Program Code" (FACTORY DEFAULT IS [9]-[7]-[1]-[3]). If the "Go To Program Code" is valid, the "Service" LED will flash and the five function LEDs will illuminate steady. You are now in the Program Mode. When the Program Mode is exited by pressing the [Exit] key, the NX-8-CF control will automatically enroll the devices. The enrolling process takes about 12 seconds, during which time the "Service" LED will illuminate. User codes will not be accepted during the enrolling process. If a speaker is attached to the NX-8-CF, it will click at this time. If a siren or bell is attached to the NX-8-CF, it will sound for about 1 second. Once a module is enrolled, if it is not detected by the control, the "Service" LED will illuminate. NOTE: In the event of a trouble condition, the address reported for the Fire Supervision module will be 9". VI. ENCLOSURE DIAGRAM Inside the can, several 3-holed insertion points have been constructed. This allows for either vertical or horizontal placement of the modules. Notice that the insertion points have two sizes of holes -- a larger hole and two smaller holes. Diagram 1: The black plastic PCB guides are grooved on the top where the PC Board is to be situated. This grooved side goes into the larger hole, while the other side has a deep notch for the screw to be secured into on one of the smaller holes. Diagram 2: Take the black plastic PCB guide, grooved side down, and place it in the top insertion point. The grooved/notched side will be in the large hole, facing the inside of the can. It should not require force, and you will detect a slight settling when it is in place. Insert one of the provided screws into the small hole (from inside the can) to secure it in place. Note: The screw will be in the small hole on the top or bottom if the board is positioned vertically, or it will be in the right or left hole if the board is placed horizontally. The second PCB slide should be positioned upside down from the first (grooved side up) and placed in the lower insertion point, using the same procedures described above. Once mounted, screw it in securely. Diagram 3: The PC board should slide freely in the grooves of both guides. 5 NX-870E Fire Supervision Module

VII. LOCAL TELEPHONE PANY INTERFACE TELEPHONE CONNECTION REQUIREMENTS Except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and standard telephone company provided jacks or equivalent in such a manner as to allow for immediate disconnection of the terminal equipment. Standard jacks shall be so arranged that if the plug connected thereto is withdrawn, no interference to the operation of the equipment at the customers premises, which remains connected to the telephone network, shall occur by reason of such withdrawal. INCIDENCE OF HARM Should terminal equipment or protective circuitry cause harm to the telephone network, the telephone company shall, where practical, notify the customer that temporary discontinuance of service may be required. However, where prior notice is not practical, the telephone company may temporarily discontinue service if such action is deemed reasonable in the circumstances. In the case of such temporary discontinuance, the telephone company shall promptly notify the customer who will be given the opportunity to correct the situation. The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted. CHANGES IN TELEPHONE PANY EQUIPMENT OR FACILITIES The telephone company may make changes in its communications facilities, equipment, operations, or procedures where such action is reasonably required and proper in its business. Should any such change render the customers terminal equipment incompatible with the telephone company facilities, the customer shall be given adequate notice to make modifications to maintain uninterrupted service. GENERAL The FCC prohibits customer provided terminal equipment be connected to party lines. IMPORTANCE OF THE RINGER EQUIVALENCE NUMBER The Ringer Equivalence Number (REN) of this device is 0.1B. This number is a representation of the electrical load that it applies to your telephone line. MALFUNCTION OF THE EQUIPMENT In the event that the device should fail to operate properly, the customer shall disconnect the equipment from the telephone line to determine if it is the customer s equipment that is not functioning properly. If the problem is with the device, the customer shall discontinue use until it is repaired. EQUIPMENT INFORMATION MANUFACTURER OF CONNECTING EQUIPMENT: CADDX CONTROLS, INC. FCC REGISTRATION NUMBER: GCQAL01BNX-870E; RINGER EQUIVALENCE: 0.1 B 6 NX-870E Fire Supervision

VIII. UNDERWRITERS LABORATORIES REQUIREMENTS Special Applications: UL Commercial Fire Must be used in conjunction with NetworX NX-8-CF Commercial Fire panel. Compatible Fire Alarm bell: Wheelock models # NS-1215W, # NS-121575W IX. ORDERING INFORMATION PART # NX-8-CF NX-8-CF-KIT-7 NX-148E-CF NX-216E NX-320E NX-508E NX-870E NX-003-CF DESCRIPTION NX8 Commercial Fire Control Panel NX8 Commercial Fire Control Panel in NX-003-CF Enclosure, NX-148E-CF LCD keypads (2); NX-870E Fire Supervision module; 16.5V 50VA Transformer NX148E LCD Keypad for Commercial Fire panel (Red plastic) 16 Zone Expander Remote Power Supply Eight Output Module Fire Supervision Module Commercial Fire Enclosure (Red) 7 NX-870E Fire Supervision Module

X. SPECIFICATIONS OPERATING POWER 12 VDC, Supplied from NX-8-CF CURRENT DRAW Standby 20 ma Operating 110 ma Communicating with Phone Line 2 Selected BELL LOAD DIMENSION SHIPPING WEIGHT 600mA Maximum 6" Wide 3.25" High 1" Deep 9 lbs. GE INTERLOGIX 1420 NORTH MAIN STREET GLADEWATER, TEXAS 75647 Main Phone 800-727-2339 Technical Support 800-727-2339 Outside the US 903-845-6941 Tech Support Fax 903-845-8409 Main Fax 903-845-6811 Sales & Literature 800-547-2556 Web: www.caddx.com www.ge-interlogix.com NX870EIA02 Rev A (Sept 2002)