Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No.

Similar documents
SEER 1½

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A

Product Data TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 07/08

Product Data WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

4YCC3048A3096A /3/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, KBTU R-410A

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Modular Multi-position Air Handler

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers

PAJ3. Product Specifications

36,000-62,000 BTUH Nominal Capacity

Advance Release September 2009

PAR5. Product Specifications

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Split System Cooling Product & Performance Data

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Split System Cooling Product & Performance Data

Cooling/Heat Pump Convertible Air Handlers

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Split System Cooling Product Data

High Heat COP. High/Low Stage

RGE 13 A T - 1 A

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Variable Speed Convertible Air Handler 5 Ton

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Split System Heat Pump Product & Performance Data

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Vertical Upflow Horizontal Left Air Handlers

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Modular Multi-position Air Handlers

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

Modular Multi-position Air Handlers

Product Data. Fig. 1 - Unit 50VR -A

Variable Speed Convertible Air Handler 4 Ton

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Split System Heat Pump Product Data

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Split System Heat Pump Product Data

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Variable Speed Convertible Air Handler 2 1/2 Ton

Split System Heat Pump Product Data

Split System Cooling Product Data

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Modular Multi-position Air Handlers

Split System Cooling Product Data

Split System Cooling Product Data

WJH4 Product Specifications

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. Convertible Air Handlers 1 1/2 5Ton

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Split System Cooling Product Data

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Product Data. Convertible Air Handlers 1 1/2 5Ton

Split System Heat Pump Product Data

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Split System Cooling Product Data

Hyperion TM Split Systems

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Split System Cooling Product Data

Bosch BVA Series Air Handler

Modular Multi-position Air Handlers

Split System Heat Pump Product Data

Transcription:

Product Data 22179614 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2 5 Ton R410A 2013 Trane Pub. No. 22179614

It's Hard to Stop a Trane. Single Packaged Cooling System Trane offers a complete family of cooling systems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. Introducing the new TRANE Single Packaged Cooling System. Single Packaged Cooling Systems are easy and versatile to install. Because cooling and air handling functions are all contained in a single cabinet, a Trane packaged air conditioner is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to an optional Trane thermostat control, and air distribution ducts, you have a highly efficient, total home comfort system. better performance. Our single packaged air conditioners offer cooling efficiencies that are unmatched in the industry and provide you with a product far superior in performance than the competition. Single Packaged Cooling Systems provide 2

Contents Optional Equipment Listing 4 General Data 5 Heater Data 8 SPEK Data 9 Performance Data Indoor Fan 12 Typical Wiring 15 Optional Equipment 18 Dimensional Data 23 Mechanical Specifications 29 3

Optional Equipment OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [3] indicates accessories included) Hinged Filter Access Door (4TCY4024036)... BAYACCDOR1A[ ] Hinged Filter Access Door (4TCY4042060)... BAYACCDOR2A[ ] Roof Curb Full Perimeter (4TCY402436) 3...BAYCURB050A[ ] Roof Curb Full Perimeter (4TCY4042060) 3...BAYCURB051A[ ] Roof Curb Utility Extension Kit (BAYCURB050A)...BAYUTIL101B[ ] Roof Curb Utility Extension Kit (BAYCURB051A)...BAYUTIL102B[ ] 025% Manual Fresh Air Damper (4TCY402436) 1...BAYOSAH001A[ ] 025% Manual Fresh Air Damper (4TCY4042060) 1...BAYOSAH002A[ ] Motorized Fresh Air Damper (4TCY402436) 1... BAYDMPR101A[ ] Motorized Fresh Air Damper (4TCY4042060) 1... BAYDMPR102A[ ] 16" Round Duct Adapter (2 per box) (4TCY402436) 6... BAYSQRD001A[ ] 18" Round Duct Adapter (2 per box) (4TCY4024060) 6... BAYSQRD002A[ ] 0100% Mod Economizer w/baro. Relief (4TCY402436) 24... BAYECON101B[ ] 0100% Mod. Economizer w/baro. Relief (4TCY4042060A) 124... BAYECON102B[ ] 0100% Horizontal Economizer (4TCY402436) 12... BAYECON200A[ ] 0100% Horizontal Economizer (4TCY4042060) 12... BAYECON201A[ ] Enthalpy Control for Economizer (solid state)...bayenth001a[ ] Remote Potentiometer (AllBAYECON***A)...BAYSTAT023[ ] 1"2" Filter Frame (4TCY402436) (20 x 25 filter not included) 1... BAYFLTR101B[ ] 1"2" Filter Frame (4TCY4042060) (20 x 20 & 20 x18 filter not included) 1..... BAYFLTR201B[ ] Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5....BAYLOAM105A[ ] Quick Start Kit (4TCY4 1)... BAYKSKT300A[ ] Crankcase Heater Recip (4TCY4024 1 (230v) 5...BAYCCHT101A[ ] Crankcase Heater Scroll (4TCY4036060 1/3)(230v) 5...BAYCCHT102A[ ] Adapter Curb 4TCY402436 to BAYCURB030,38... BAYADAP050A[ ] Adapter Curb 4TCY402436 to BAYCURB033... BAYADAP051A[ ] Adapter Curb 4TCY4042060 to BAYCURB030,38... BAYADAP052A[ ] Adapter Curb 4TCY4042060 to BAYCURB033... BAYADAP053A[ ] Adapter Curb 4TCY4042060 to BAYCURB034... BAYADAP054A[ ] 12" Duct Shroud Covers Horizontal 4TCY40240607...BAYCOVR112A[ ] 18" Duct Shroud Covers Horizontal 4TCY4024060 7...BAYCOVR118A[ ] Extreme Condition Mounting Kit All BAYCURB & BAYADAP...BAYEXMK001A[ ] Extreme Condition Mounting Kit All BAYUTIL...BAYEXMK002B[ ] Extreme Condition Mounting Kit All Slab Mounts...BAYEXMK003A[ ] Lifting Lug Kit...BAYLlFT002B[ ] SUPPLEMENTARY HEATERS (1 PHASE) 3.76/5.0 KW Heater (208/240V 1PH) (4TCY4024060 1)... BAYHTRV105E[ ] 3.76/5.0 KW Heater (208/240V 1PH) (4TCY4024060 1)... BAYHTRV108E[ ] 7.50/10.0 KW Heater (208/240V 1PH) (4TCY4024060 1)... BAYHTRV110E[ ] 11.27/15.00 KW Heater (208/240V 1PH) (4TCY4030060 1)... BAYHTRV115E[ ] 15.0/20.0 KW Heater (208/240V 1PH) (*4TCY4042060 1)... BAYHTRV120E[ ] 18.78/25.0 KW Heater (208/240V 1PH) (4TCY4042060 1)...... BAYHTRV125E[ ] SUPPLEMENTARY HEATERS (3 PHASE) 3.76/5.0 KW Heater (208/240V 3PH) (4TCY4036060 3)... BAYHTRV305E[ ] 3.76/5.0 KW Heater (208/240V 3PH) (4TCY4036060 3)... BAYHTRV308E[ ] 7.50/10.0 KW Heater (208/240V 3PH) (4TCY402448 3)... BAYHTRV310E[ ] 11.27/15.00 KW Heater (208/240V 3PH) (4TCY4036060 3)... BAYHTRV315E[ ] 15.00/20.0 KW Heater (208/240V 3PH) (4TCY4048060 3)... BAYHTRV320E[ ] 18.78/25.0 KW Heater (208/240V 3PH) (4TCY4048060 3)...... BAYHTRV325E[ ] Single Power Entry Kit 8... BAYSPEK060F[ ] Single Power Entry Kit 8... BAYSPEK061E[ ] Single Power Entry Kit 8... BAYSPEK062F[ ] Single Power Entry Kit 8... BAYSPEK063F[ ] Single Power Entry Kit 8... BAYSPEK064E[ ] Single Power Entry Kit 8... BAYSPEK065E[ ] NOTES: 1 Must use internal filter frame when economizer or fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow only. 5 Low Ambient cooling requires crankcase heater (BAYCCHTB). 6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications. 8 See table on page 8 for matching kit with units and heaters. = A or B 4

General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/WattHr.) Sound Power Rating [db(a)] POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity Fuse Size Max. (amps) Fuse Size Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4TCY4024A1000B 23400 780 1.99 12 / 14.0 68 16.5 25 25 RECIPROCATING 200230/1/60 8.3 / 57.8 SPINEFIN 2 / 24 13.32 PLATE FIN 3 / 15 3.54 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 2560 1/12 / 810 230/1/60 0.54 / 0.95 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1/2 / VARIABLE 200230/1/60 4.3 / 4.3 NO THROWAWAY 4.0 R410A 6.0 H X W X L 45.86 / 44.5 / 52.03 444 / 348 4TCY4030A1000B 30000 900 2.5 12.0 / 14.0 71 19.1 30 30 RECIPROCATING 11.1 / 63 SPINEFIN 2 / 24 13.32 PLATE FIN 3 / 15 3.54 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 2550 1/6 / 830 0.9 / 1.7 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1/2 / VARIABLE 4.3 / 4.3 NO THROWAWAY 4.0 R410A 6.30 H X W X L 45.86 / 44.5 / 52.03 444 / 348 4TCY4036B1000B 38000 1195 3.17 12.0 / 14.2 69 26.3 40 40 SCROLL 16.7 / 69 SPINEFIN 2 / 24 15.49 PLATE FIN 4 / 15 3.54 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 3300 1/5 / 830 230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1/2 / VARIABLE 200230/1/60 4.3 / 4.3 NO THROWAWAY 4 R410A 7.80 H X W X L 47.86 / 44.5 / 52.03 450 / 354 1 Rated in accordance with AHRI Standard 210/240. 2 Sound Power values are not adjusted for ARI 27095 tonal corrections. 3 Calculated in accordance with currently prevailing Nat'l Electrical Code. 4 Standard Air Dry Coil Outdoor. 5 Standard Air Wet Coil Indoor. 6 Rated in accordance with D.O.E. test procedure. 7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 5

General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/WattHr.) Sound Power Rating [db(a)] POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity Fuse Size Max. (amps) Fuse Size Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4TCY4036B3000A 208230/3/60 37000 1195 3.17 12.0 / 14.2 69 208230/3/60 18.4 25 25 SCROLL 208230/3/60 10.4 / 73 SPINEFIN 2 / 24 15.49 PLATE FIN 4 / 15 3.54 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 3260 1/5 / 830 230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1/2 / VARIABLE 200230/1/60 4.3 / 4.3 NO THROWAWAY 4 R410A 7.80 H X W X L 47.86 / 44.5 / 52.03 450 / 354 4TCY4042B1000B 42000 1420 3.5 12.0 / 14.25 74 30.7 45 45 SCROLL 17.9 / 112 SPINEFIN 2 / 24 18.01 PLATE FIN 3 / 15 5 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 4460 1/4 / 825 1.4 / 3.4 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 6.8 / 6.8 NO THROWAWAY 5.3 R410A 7.00 H X W X L 47.86 / 47.4 / 61.75 607 / 479 4TCY4048B1000B 48500 1605 4.041 12 / 14.2 72 35.5 50 50 SCROLL 21.8 / 117 SPINEFIN 2 / 24 18.01 PLATE FIN 3 / 15 5.0 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 4460 1/4 / 825 230/1/60 1.4 / 3.37 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 200230/1/60 6.8 / 6.8 NO THROWAWAY 5.3 R410A 8.30 H X W X L 47.86 / 47.4 / 61.75 623 / 495 1 Rated in accordance with AHRI Standard 210/240. 2 Sound Power values are not adjusted for AHRI 27095 tonal corrections. 3 Calculated in accordance with currently prevailing Nat'l Electrical Code. 4 Standard Air Dry Coil Outdoor. 5 Standard Air Wet Coil Indoor. 6 Rated in accordance with D.O.E. test procedure. 7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 6

General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/WattHr.) Sound Power Rating [db(a)] POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity Fuse Size Max. (amps) Fuse Size Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4TCY4048B3000A 208230/3/60 48500 1605 4.041 12.0 / 14.2 72 208230/3/60 25.3 35 35 SCROLL 208230/3/60 13.7 / 83.1 SPINEFIN 2 / 24 18.01 PLATE FIN 3 / 15 5.0 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 4460 1/4 / 825 230/1/60 1.4 / 3.37 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 200230/1/60 6.8 / 6.8 NO THROWAWAY 5.3 R410A 8.30 H X W X L 47.86 / 47.4 / 61.75 607 / 479 4TCY4060A1000B 60000 1800 4.93 12.0 / 14.0 76 41.6 60 60 SCROLL 26.4 / 134 SPINEFIN 2 / 24 23.57 PLATE FIN 4 / 15 5.0 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 5720 1/3 / 825 230/1/60 1.7 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1 / VARIABLE 6.9 / 6.9 NO THROWAWAY 5.3 R410A 10.10 H X W X L 51.86 / 47.4 / 61.75 612 / 484 4TCY4060A3000B 208230/3/60 60000 1800 4.93 12.0 / 14.0 76 208230/3/60 28.6 40 40 SCROLL 208230/3/60 16.0 / 110 SPINEFIN 2 / 24 23.57 PLATE FIN 4 / 15 5.0 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 5720 1/3 / 825 230/1/60 1.7 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1 / VARIABLE 6.9 / 6.9 NO THROWAWAY 5.3 R410A 10.10 H X W X L 51.86 / 47.4 / 61.75 612 / 484 1 Rated in accordance with AHRI Standard 210/240. 2 Sound Power values are not adjusted for AHRI 27095 tonal corrections. 3 Calculated in accordance with currently prevailing Nat'l Electrical Code. 4 Standard Air Dry Coil Outdoor. 5 Standard Air Wet Coil Indoor. 6 Rated in accordance with D.O.E. test procedure. 7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 7

Heater Data 4TCY4024 to 4TCY4060 Heater Data UNIT MODEL ELECTRIC HEATER MODEL RATED VOLTAGE PHASE AMPS HEATER CAPACITY KW/STAGE NO. OF KW BTUH STAGES 1 2 MCA MAX FUSE OR HACR CKT BKR SIZE (4) CANADA ONLY MAX. CKT BKR SIZE (5) ^W/TC*3018060 1 ^W/TCY4024060 1 ^WCZ6036060 1 BAYHTRV105E 208/240 1 18/21 3.76/5.0 12800/17100 1 3.76/5.0 23/26 25/30 25/30 ^W/TC*3018060 1 ^W/TCY4024060 1 ^WCZ6036060 1 BAYHTRV108E 208/240 1 29/33 6.0/8.0 20500/27300 1 6.0/8.0 36/41 40/45 40/45 ^W/TC*3024060 1 ^W/TCY4024060 1 ^WCZ6036060 1 ^W/TC*3030060 1 ^W/TCY4030060 1 ^WCZ6036060 1 ^W/TC*3042060 1 ^W/TCY4042060 1 ^WCZ6048060 1 4WC*3042 1 ^W/TC*3060 1 ^W/TCY4042060 1 ^WCZ6048060 1 BAYHTRV110E BAYHTRV115E# BAYHTRV120E# BAYHTRV125E# 208/240 1 36/42 7.5/10.0 25600/34100 1 7.5/10.0 45/52 45/60 208/240 1 54/63 11.27/15.0 38500/51200 2 7.5/10.0 3.76/5.0 68/78 70/80 208/240 1 72/83 15.0/20.0 51200/68300 2 7.5/10.0 7.5/10.0 90/104 90/110 208/240 1 90/104 18.78/25.0 64100/85300 2 11.26/15.0 7.5/10.0 113/130 125/150 45/60 70/80 90/110 125/150 ^W/TC*3036060 3 ^W/TCY4036060 3 ^WCZ6036060 3 BAYHTRV305E 208/240 3 10/12 3.76/5.0 12800/17100 1 3.76/5.0 13/15 15/15 15/15 ^W/TC*3036060 3 ^W/TCY4036060 3 ^WCZ6036060 3 BAYHTRV308E 208/240 3 17/19 6.0/8.0 20500/27300 1 6.0/8.0 21/24 25/25 25/25 ^W/TC*3036060 3 ^W/TCY4036060 3 ^WCZ6036060 3 ^W/TC*3036060 3 ^W/TCY4036060 3 ^WCZ6036060 3 ^W/TC*3048060 3 ^W/TCY4048060 3 ^WCZ6048060 3 ^W/TC*3060 3 ^W/TCY4048060 3 ^WCZ6048060 3 ^W/TC*3036060 4 ^WCZ6036060 4 ^W/TC*3036060 4 ^WCZ6036060 4 ^W/TC*3036060 4 ^WCZ6036060 4 BAYHTRV310E BAYHTRV315E BAYHTRV320E BAYHTRV325E# BAYHTRV405E 7.5/10.0 208/240 3 42/48 15.0/20.0 51200/68300 2 7.5/10.0 208/240 3 40/45 40/45 BAYHTRV408E 480 3 10 8.0 27300 1 8.0 13 15 15 BAYHTRV410E 208/240 3 208/240 3 480 480 3 3 21/24 7.5/10.0 25600/34100 1 31/36 11.27/15.0 38500/51200 52/60 18.78/25.0 64100/85300 6 5.0 17100 12 10.0 34100 2 7.5/10.0 3.76/5.0 2 1 11.26/15.0 7.5/10.0 5.0 1 10.0 7.5/10.0 26/30 30/30 30/30 39/45 52/60 60/60 65/75 8 15 70/80 15 60/60 70/80 15 15 15 ^W/TC*3036060 4 ^WCZ6036060 4 ^W/TC*3048060 4 ^WCZ6048060 4 ^W/TC*3060 4 ^WCZ6048060 4 BAYHTRV415E BAYHTRV420E BAYHTRV425E 480 3 18 15.0 480 3 24 20.0 480 3 30 25.0 51200 68300 85300 2 2 2 10.0 10.0 15.0 5.0 23 25 25 10.0 30 30 30 10.0 38 40 40 General Table Notes: Any power supply and circuits must be wired and protected in accordance with local electrical codes. 2 The MCA values listed are for electric heater only. Field wire must be rated at least 75 C 4 The HACR circuit breaker is for U.S.A. installations only. 5 For Canada installation reference only. # Heater uses fuses. Unit Model Notes: ^ = 2 or 4 * = C or X = A or B 8

Single Power Entry Kit Data Notes: * = C or X = A or B 9

Single Power Entry Kit Data Notes: * = C or X = A or B 10

Single Power Entry Kit Data Notes: * = C or X = A or B 11

Indoor Blower Performance Indoor Fan Performance (230v) 4TCY4024 (230vperformance) Horizontal Airflow 4TCY4024HOR DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON ON 400 CFM/TON* 450 CFM/TON ON Down Airflow Watts 52 66 89 115 140 164 186 206 229 259 CFM 706 716 727 733 731 719 700 679 662 659 Watts 72 94 120 148 177 207 233 254 267 290 CFM 786 793 805 813 813 806 793 780 778 799 Watts 80 99 125 153 182 211 243 284 342 CFM 860 862 877 892 903 904 897 884 869 4TCY4024DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON ON 400 CFM/TON* 450 CFM/TON ON Watts 35 70 90 108 131 160 188 204 225 250 CFM 695 729 734 728 721 715 705 679 680 685 Watts 79 87 105 129 155 180 206 232 264 306 CFM 846 807 802 810 816 813 803 794 800 846 Watts 86 102 127 156 185 213 242 275 319 CFM 884 870 882 899 909 907 895 886 898 Indoor Fan Performance (230v) 4TCY4030 (230vperformance) Horizontal Airflow 4TCY4030HOR DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON ON 400 CFM/TON* 450 CFM/TON ON Watts 106 135 164 193 220 247 275 306 CFM 860 887 901 907 905 899 887 870 Watts 136 172 199 226 256 288 316 329 CFM 972 996 1001 1000 1000 999 988 951 Watts 182 218 251 283 317 351 381 CFM 1108 1113 1119 1121 1119 1115 1119 Down Airflow 4TCY4030DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON ON 400 CFM/TON* 450 CFM/TON ON Watts 109 133 162 190 214 234 259 298 CFM 856 867 875 876 869 855 842 838 Watts 134 174 200 222 247 276 306 328 CFM 960 987 980 968 965 966 952 884 Watts 184 216 254 289 318 343 375 CFM 1087 1094 1103 1107 1105 1098 1091 *Factory Default Setting 12

Indoor Blower Performance Indoor Fan Performance (230v) 4TCY4036 (230vperformance) Horizontal Airflow 4TCY4036HOR DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON ON Watts 162 173 197 226 256 285 313 343 360 CFM 1058 1062 1063 1063 1062 1060 1057 1053 1010 400 CFM/TON* Watts 179 230 265 296 329 366 403 431 436 CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 450 CFM/TON ON Watts 318 336 365 399 435 469 502 533 CFM 1390 1376 1370 1366 1361 1354 1349 1351 Down Airflow 4TCY4036DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON ON Watts 169 182 210 243 273 301 331 370 433 CFM 1025 1062 1068 1063 1060 1061 1064 1055 1015 400 CFM/TON* Watts 225 253 283 315 348 381 414 449 484 CFM 1187 1201 1203 1201 1198 1197 1194 1184 1157 450 CFM/TON ON Watts 339 357 390 424 455 483 516 571 CFM 1391 1377 1377 1375 1366 1352 1344 1360 Indoor Fan Performance (230v) 4TCY4042 (230vperformance) Horizontal Airflow 4TCY4042HOR DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON 400 CFM/TON* 450 CFM/TON ON ON Watts Watts Watts 181 261 353 211 296 390 241 325 426 270 352 462 298 380 499 327 411 536 355 444 573 382 477 609 408 509 645 CFM CFM CFM 1248 1444 1608 1250 1448 1611 1253 1441 1613 1254 1429 1613 1249 1417 1612 1240 1407 1608 1225 1400 1603 1209 1394 1597 1195 1386 1590 Down Airflow 4TCY4042DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON 400 CFM/TON* 450 CFM/TON ON ON Watts Watts Watts 195 289 385 229 312 422 258 341 457 283 371 491 308 402 527 335 432 563 362 461 600 390 491 636 415 523 670 CFM CFM CFM 1240 1433 1604 1244 1422 1602 1245 1415 1600 1243 1411 1598 1238 1405 1596 1229 1399 1593 1217 1392 1590 1203 1383 1585 1189 1377 1578 *Factory Default Setting 13

Indoor Blower Performance Indoor Fan Performance (230v) 4TCY4048 (230vperformance) Horizontal Airflow 4TCY4048HOR DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON ON Watts 187 232 264 291 318 347 379 413 446 472 CFM 1355 1387 1396 1392 1382 1370 1360 1351 1341 1326 400 CFM/TON* Watts 315 324 352 389 428 464 498 529 563 606 CFM 1603 1581 1577 1580 1583 1583 1577 1567 1558 1556 450 CFM/TON ON Watts 301 431 507 552 584 615 651 694 739 779 CFM 1752 1794 1812 1816 1812 1806 1800 1797 1793 1785 Down Airflow 4TCY4048DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 350 CFM/TON ON Watts 208 254 284 312 343 379 414 437 460 490 CFM 1337 1393 1398 1388 1383 1390 1399 1384 1380 1370 400 CFM/TON* Watts 302 349 386 423 465 509 552 583 599 628 CFM 1574 1580 1585 1589 1594 1598 1601 1597 1584 1556 450 CFM/TON ON Watts 501 523 555 592 631 672 714 760 800 845 CFM 1847 1823 1817 1818 1820 1819 1817 1820 1815 1810 Indoor Fan Performance (230v) 4TCY4060 (230vperformance) Horizontal Airflow 4TCY4060AHOR DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 350 CFM/TON ON Watts 394 427 464 504 548 591 633 668 CFM 1673 1772 1799 1793 1779 1771 1767 1756 400 CFM/TON* Watts 695 642 660 710 764 811 849 893 966 1108 CFM 2054 2036 2031 2032 2033 2031 2023 2012 2002 2000 Down Airflow 4TCY4060ADOWN DIPSWITCH SETTINGS External Static Pressure (in. wg) AIRFLOW SETTING 1 2 3 4 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 350 CFM/TON ON Watts 443 461 493 532 571 607 642 680 CFM 1796 1741 1726 1725 1722 1712 1698 1692 400 CFM/TON* Watts 740 697 715 763 819 866 892 894 872 835 CFM 2010 1987 1979 1977 1976 1969 1950 1913 1852 1759 *Factory Default Setting 14

4TCY4024 AIRFLOW WITH AUXILIARY HEAT (CFM) SWITCH SETTINGS SELECTION NOMINAL AIRFLOW 7 8 LOW 700 CFM 7ON 8 HIGH 800 CFM 7 8ON HIGH 800 CFM 7ON 8ON HIGH 800 CFM 4TCY4030 AIRFLOW WITH AUXILIARY HEAT (CFM) SWITCH SETTINGS SELECTION NOMINAL AIRFLOW 7 8 LOW 1050 CFM 7ON 8 HIGH 1200 CFM 7 8ON HIGH 1200 CFM 7ON 8ON HIGH 1200 CFM Indoor Blower Performance COOLING FAN DELAY OPTIONS NOMINAL SWITCH SETTINGS DELAY AIRFLOW 5 6 NONE 100% 5ON 6 45 SEC 100% 5 6ON 90 SEC 50% 5ON 6ON ** 50100% ** This ENHANCED MODE selection provides a ramping up and ramping down of the indoor blower speed to provide improved comfort, quietness, and potential energy savings. The Graph below shows the ramping process 100% if necessary 4TCY4036 AIRFLOW WITH AUXILIARY HEAT (CFM) 80% SWITCH SETTINGS SELECTION NOMINAL AIRFLOW 7 8 LOW 1050 CFM 7ON 8 HIGH 1200 CFM 7 8ON HIGH 1200 CFM 7ON 8ON HIGH 1200 CFM FAN OPERATION (CFM) 50% Dehumidify Fast Coil Cooling Efficiency 50% 4TCY4042 AIRFLOW WITH AUXILIARY HEAT (CFM) SWITCH SETTINGS SELECTION NOMINAL AIRFLOW 7 8 LOW 1400 CFM 7ON 8 HIGH 1600 CFM 7 8ON HIGH 1600 CFM 7ON 8ON HIGH 1600 CFM 1 minute 7.5 minutes COMPRESSOR OPERATION ON as required 3 minutes 4TCY4048 AIRFLOW WITH AUXILIARY HEAT (CFM) SWITCH SETTINGS SELECTION NOMINAL AIRFLOW 7 8 LOW 1400 CFM 7ON 8 HIGH 1600 CFM 7 8ON HIGH 1600 CFM 7ON 8ON HIGH 1600 CFM 4TCY4060 AIRFLOW WITH AUXILIARY HEAT (CFM) Switch Setting Selection Normal Airflow 7 8 LOW 1750 CFM 7ON 8 HIGH 2000 CFM 7 8ON HIGH 2000 CFM 7ON 8ON HIGH 2000 CFM 15

Typical Wiring 16

Typical Wiring 17

Optional Equipment BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB FOR *****024036 17 7/8 46 3 3 5/8 19 1/2 14 2 3/16 15 19 1/2 38 7/8 1 1/2 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 35 7/8 43 18

Optional Equipment BAYCURB051A Full Perimeter Roof Mounting Curb for *****042060 15 7/8 56 1/8 3 1 1/2 20 19 1/2 4 3/4 10 7/8 41 7/8 19 1/2 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 38 7/8 53 1/8 19

Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) A HVAC Unit Economizer rain hood Economizer Unit Application Models A Mist eliminator Outside air dampers Return air dampers Required filter kit, order separately BAYECON101A BAYECON102A 4TC*,WC*,YC*,DC* *018036 4TC*,WC*,YC*, DC* *042060 20.125" 24.375" Relief damper Roofcurb Return Duct BAYECON200,201A Horizontal Economizer and Rain Hood The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Economizer C A B D Gaskets (2) Duct E Rain Hood Mixed Air Sensor Economizer A B C D E F BAYECON200AA 22" 20" 167/8" 1511/16" 1111/16" 15" BAYECON201AA 26" 2221/32" 19" 1711/16" 1411/16" 21" 20

Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. D C A FULLY OPEN 2/3 1/3 B FULLY CLOSED Manual Fresh Air Model BAYOSAH001 BAYOSAH002 Unit Application Models 4YC,WC3018036 4TC*3018036, 4W/T/Y/DCY4024036, 4W/Y/DCZ6036 4YC,WC3042060, 4TC*3042060, 4W/T/Y/DCY4042060, 4W/Y/DCZ6048060 A B C D 22 7/16"" 20 11/16"" 12 "" 9 3/16"" 25 3/16"" 20 11/16"" 12 "" 9 3/16"" BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) A C B E D Unit Application Models A B C D E BAYDMPR101A BAYDMPR102A 4YC,WC3018036 4TC*3018036, 4W/T/Y/DCY4024036, 4W/Y/DCZ6036 4YC,WC3042060, 4TC*3042060, 4W/T/Y/DCY4042060, 4W/Y/DCZ6048060 15 13/16"" 11 13/16"" 10 1/4"" 11 1/2"" 12 1/4"" 18 3/16"" 15 1/8"" 10 1/4"" 11 1/2"" 12 1/4"" 21

Optional Equipment BAYFLTR101, 201B, 1" 2" Filter Rack (Mounts in Filter/Coil Section) Filter BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 22

Dimensional Data and Weights NOTE: The view labeled Bottom Side represents the Base as viewed looking up from underneath the unit. 4TCY4024 through 4TCY4036 (1 of 3) 23

Dimensional Data and Weights 4TCY4024 through 4TCY4036 (2 of 3) 24

Dimensional Data and Weights 4TCY4024 through 4TCY4036 (3 of 3) 25

Dimensional Data and Weights NOTE: The view labeled Bottom Side represents the Base as viewed looking up from underneath the unit. 4TCY4042 through 4TCY4060 (1 of 3) 26

Dimensional Data and Weight 4TCY4042 through 4TCY4060 (2 of 3) 27

Dimensional Data and Weight 4TCY4042 through 4TCY4060 (3 of 3) 28

General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with R 22. All units shall be factory run tested to check cooling operation, fan and blower rotation and control sequence. Units shall be designed to operate at ambient temperatures between 55 F and 115 F in cooling as manufactured. Cooling performance shall be rated in accordance with A.H.R.I. standards. Unit Casing All panels shall be heavy gauge steel, gasketed and insulated. Foilfaced fiber insulation shall be in the heater section. Foilfaced fiber insulation shall be in the evaporator section. Base pan shall be heavy gauge steel. WEATHERGUARD exteriorcorrosionresistant screws shall be used for added resistance to rust and corrosion. Compressor The compressor shall be a hermetically sealed, high efficiency Climatuff compressor. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Other features include, centrifugal oil pump and low vibration and noise. Refrigeration System All units shall have refrigerant control. Service pressure tap ports, and a refrigerant line filter shall be standard. Evaporator Coil Internally enhanced inch OD seamless copper tubing me chani cally bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig. All units have a TXV to control refrigerant flow. Mechanical Specifications Condenser Coil The Spine Fin condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Directdrive, forwardcurved, centrifugal wheel in a Composite Vortica Blower housing. Motor shall have thermal overload protection and permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Outdoor Fan One direct drive, statically and dynamically balanced propeller fan shall be used in a draw through configuration. Permanently lubricated weather proof motor shall have built in thermal overload protection. System Controls System controls include condenser fan, evaporator fan and compressor contactors. Accessories Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal between supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory installed wood nailer strips. Electric Heaters Each heater assembly shall include power supply fusing if over 48 amps, automatic resetting limit switches and heat limiters for thermal protection. Heaters shall be provided with polarized plugs for quick connection to unit low voltage wiring. Single Source Power Entry This accessory, when used with electric heat accessory, shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut to length interconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit components shall install within the heater cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer This accessory shall be field installed and be composed of the following items: 0 100% fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the downflow economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment off cycle. Manual Outside Air Dampers Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit Extra compressor starting capacity for single phase equipment. ControlOptionsStandardIndoorThermostats Two stage heating/cooling or one stage heating/cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setback Thermostat Programmable electronic thermostat shall provide heating setback and cooling setup with 7 day, programming capability. 1 H/1 C or 2H/2C models available. Trane 6200 Troup Highway Tyler, TX 757079010 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 29