Variable Speed Drives: Reducing the energy costs of commercial HVAC systems

Similar documents
Refrigeration: Reducing energy costs in dairy parlours

RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

CHOOSING A COOLING SYSTEM

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

General HVAC Recommendations

Improving Performance with a Building Tune-Up. Janice Peterson, P.E. LEED AP Market Manager, Building Operations BetterBricks

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

Commercial Maintenance Agreement (CMA) Benefits

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Quality Products AHU Repair, Refurbishment and Replacement

Kills bills. How Vaillant technologies reduce home heating bills

Energy audit checklist

Energy Saving Fact Sheet Agriculture & Horticulture

COMMERCIAL ENERGY SAVINGS GUIDE

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

10 tips for getting more reliability from your air-conditioning system [reliability]

b.) Technical Information:

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Appendix 13. Categories of Cooling and Heating systems

Heating Efficiency Program COLORADO

Addressing Energy & Comfort in Ageing Leisure Centres. Luke Treadwell Senior Engineer, Arup

Checklists LAUNDRY GREENKEYGLOBAL.COM

30 Great Energy Savings Tips for Your Businesses

FirstEnergy Program Overview

MCH Series Drives. HVAC Application Guide. ag-mch-e2

Introduction. Motor Types

5 Cool Tips for Getting the Right Air Conditioning System pg. 1

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Connected Control (BCC100)

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Screw Compressors ESM Fixed Speed & VS Variable Speed

Distributed By: M&M Control Service, Inc Building Technologies

CN7232 Advanced Garage Ventilation Controller

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

PRODUCT RANGE: ROOFTOP PACKAGE

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

ACMVTECH HIGH EFFICIENCY UNITARY AHU

HVAC Water chiller selection and optimisation of operation

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

A Manufacturer s Guide to High Performance CSA P.9 Tested Combos

Reducing Energy Use in Grain Dryers

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Energy Saving Service

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

LOW TEMPERATURE FREEZER MANAGEMENT GUIDE

Energy Efficient Fan and Dust Collection Systems

Selected Laboratory Energy Efficiency Measures

Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings

Heat Pump Water Heaters

Energy recovery from exhaust gases using Heat Pipe technology

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Selection of air conditioning systems

about your house Before You Start an Energy-Efficient Retrofit Mechanical Systems

Climate control systems Providing optimum HVAC solutions for all types of standard and bespoke applications

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

Precision Ultrasonic Cleaning Equipment Buyers Guide

WESTERN HTDM 90+ OMEGA 91% & 95% EFFICIENT INDIRECT FIRED HEAT EXCHANGER UP TO 60:1 TURNDOWN HEAT ONLY & HEAT / COOL UNITS

CPVS PRODUCT DESCRIPTION

INSTRUCTION MANUAL P Heating and 1 Cooling

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Tips To Help Conserve Electricity

Combined Space and Water Heating: Making it Work

Overview. Heating and Cooling System Strategy

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

USER S GUIDE. For all Packaged Systems (Air Conditioners and Heat Pumps)

Air-Conditioning Buying Guide

TopMaster Air Handling unit. Installation instructions

Sunny Hills. HVAC Maintenance Checklist Template. conducted for. Conducted on 31 Oct :40 PM. Prepared by Jon Nieve

Home owner user pack for the Nibe 200P

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Boiler Manager Technical Report

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

HEATING, VENTILATION AND AIR CONDITIONING. Saving energy without compromising comfort.

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Better Design, Better Control, Better Systems.

Energy Recovery Ventilation

OWNER S MANUAL. SACC Series Add-On Cooling Unit. (English) (SACC)

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Energy consumption in properties

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

Troubleshooting the Indoor AHU as a Standard Product

Operation Manual R205BV, R209BV

New Zealand Sales Hotline: Sales Fax:

Climate Control System

Operating Performance

FREQUENTLY ASKED QUESTIONS

INDUSTRIALS GROUP. Screw Compressors. ESM Fixed Speed & VS Variable Speed

Natural Gas & Propane Burners

PLP - TERMS AND CONDITIONS Philadelphia Gas Works Residential Parts & Labor Plan Contract

EC Fans Growing in Popularity

Transcription:

Variable Speed Drives: Reducing the energy costs of commercial HVAC systems Factsheet

Using Variable Speed Drives (VSDs) to reduce the cost of heating, ventilation and air conditioning (HVAC) systems in commercial buildings B y virtue of their energy intensiveness, heating, ventilation and air conditioning (HVAC) systems account for a large percentage of companies energy costs. Continued misuse can dramatically impact on the effectiveness of companies energy-saving projects and initiatives, which are mostly driven by the need to reduce operating costs. HVAC systems are responsible for 26% of the electricity consumed in the commercial sector, with motors that drive compressors, pumps and fans in these systems accounting for more than 98% of that energy. Variable Speed Drives (VSDs), when applied to HVAC systems, can provide energy savings of between 20 and 40%, while also enhancing operation and comfort. VSDs are potentially the most underutilised tools for optimising the energy efficiency of electrical equipment. Using them in suitable applications such as HVAC systems can save energy, cut operating costs and extend the lifespan of equipment. VSDs explained A VSD, also known as a Variable Frequency Drive or Adjustable Speed Drive, is a device that can adjust electricity supply and regulates and adapts motor speed to match the actual demand required by the system or application it is driving, resulting in a reduction in energy consumption. VSDs offer a high degree of motor control, accurately varying motor speed according to demand whilst adjusting torque accordingly all within the specifications of a particular manufacturer.

VSDs come in different sizes and are typically encased in boxes as small as a milk carton or as big as a cupboard. Sizes range from 0.18kW through to several MW. They are available as stand-alone devices and are connected to motors electrical supply. On some smaller motor designs usually under 15kW VSDs may be built onto motors and are available as integrated motor drives. A basic VSD can be used for simple applications, such as controlling a pump or a fan where variable loads are required. It can also be interfaced with a transducer, such as a pressure or flow rate sensor, and programmed to maintain a particular setting. More advanced VSDs can be used for precise speed and torque control in complex applications like materials forming and can be interfaced with a computing system to provide real time operating data on the status and performance of a motor. VSDs can be used in a wide variety of applications including most kinds of ventilation systems, air extraction systems, cooling systems and combustion-air control systems for boilers. Variable Speed Drives can vary the output of your HVAC system to meet your building s needs throughout the day. This will help you save energy and money. Taking the load off HVAC systems in commercial buildings VSDs are ideal for equipment with varying load conditions such as HVAC systems. Even in the most energy-efficient HVAC systems, VSDs can help to further reduce energy usage by closely matching the speed of the motors that drive the systems with actual demand. When HVAC systems require less cooling or heating than the maximum load that it was sized for, VSDs allow the compressors, blowers and condenser fans (in the case of a screw in compressor) to operate at a lower speed and, therefore, use less electricity. There is a broad range of Variable Speed Drives available specifically engineered for heating, ventilation and air conditioning applications, which can be integrated into a variety of building management systems to improve flexibility and optimise energy efficiency. In ventilation systems for large buildings, VSDs on fans save energy by allowing the volume of air moved to match the system s demand. Variable Speed Drives are also used on pumps and other equipment.

When linked by remote control, a VSD can be used to switch off motors or to lower the speed of motors to decrease the flow rate during Eskom s peak hours of demand for electricity. VSDs are particularly suitable for electronic control systems such as Programmable Logic Controllers (PLCs) and Personal Computers (PCs). These systems are typically used in complex building climate control systems. By responding to inputs from various sensors in the building and adjusting the speed of relevant motors, the process can be kept at optimal speed and wastage is minimised. VSDs are one of the most cost effective methods to increase efficiency and reduce the costs of HVAC systems they cut power usage and prevent energy wastage by precisely matching motor speed with cooling demand. Putting VSDs to work Conduct a proper feasibility study before investing in a VSD to ensure that it is the best solution to optimise your HVAC system. VSDs can increase harmonics in the electricity supply, which disturb the sine curve of the Alternating Current and cause motors to run warmer than they are designed for, reducing their life expectancy. Harmonics can also decrease the life expectancy of computers and negatively influence the operation and accuracy of electronic measuring devices. The appropriate harmonic filters and chokes must, therefore, be installed along with the VSD to filter out the harmonics and protect your equipment. Spend a bit more on quality VSDs are high tech; mixing low quality with high tech is not recommended. Full energy-saving gains will be achieved when harmonic filter protections and components are properly installed and tested. Since VSDs are dust sensitive, an appropriate dust filter needs to be installed when operating in dusty conditions they also need to operate within specified temperature and humidity parameters. VSDs must be installed by qualified installers that can back up their product. Once installed, a VSD must be properly programmed setting incorrect parameters will result in poor control and energy wastage. Regular maintenance of VSDs and associated motors is essential to maintain energy savings; preventive maintenance is always less expensive than correcting faults and having unanticipated breakdowns. Opt for a maintenance contract with your supplier to ensure the VSD is kept in an optimal condition. Important note: If you have a power factor correction capacitor installed, remove it before installing a VSD.

Additional tips to help reduce HVAC system energy costs: Where boilers are used check for scale deposits, electrical contacts, heater elements and control instrumentation For compressors that are cooling on a regular basis, listen for unusual sounds or vibrations and check for signs of wear Regularly lubricate fan bearings and clean fan components Regularly replace dirty or blocked air filters and leaky dampers Use economiser controls Insulate thermal surfaces such as coolant and hot water pipe work Inspect ductwork for air leaks For cooling equipment, ensure heat exchanger surfaces are clean and reset evaporation and condensation temperatures, particularly under extreme operating conditions Take full advantage of various control and heat recovery devices on the ventilation system Ensure that electrical equipment is working at the rated voltage Establish and follow a regular maintenance programme make sure that staff are trained accordingly and take advantage of a computer programme to facilitate maintenance scheduling When fitting new equipment ask your supplier to conduct a proper needs analysis, replace oversized motors and size new units at optimal efficiency Ask an experienced specialist to properly balance your ventilation system Reduce HVAC operating hours to reduce electrical, heating and cooling requirements Eliminate HVAC usage in unoccupied offices, underutilised communal spaces and empty store rooms Minimise direct cooling in unoccupied areas by turning off fan coil units and unit heaters, and closing the vent or air supply diffuser Adjust thermostat settings for a change in seasons Check the combustion efficiency by measuring carbon dioxide and oxygen concentrations and the temperature of stack gases; make the necessary adjustments Close outdoor air dampers Install heat recovery ventilators that exchange between 50 and 70% of the energy between the incoming fresh air and the outgoing return (conditioned) air Be sure to switch off air-conditioners when leaving the office after a day s work or install timers to switch air-conditioners off to prevent them from running overnight or over weekends. Consider installing occupancy sensors, which will switch on HVAC systems based on occupancy and switch them off when rooms are left vacant.

Eskom s Energy Advisors are on standby to assist you. Eskom s national Advisory Service offers information on manufacturers and suppliers of VSDs. The team can also advise businesses on: Reducing energy usage Doing walk-through energy assessments to identify energy usage patterns, energy needs, areas of energy wastage and energy-saving opportunities Improving the energy efficiency of operations and electrical systems and processes Prioritising maintenance as an important contributor to reducing energy usage Finding SANAS approved energy savings Measurement & Verification Authorities. Advisors can also provide information on funding opportunities for energy efficiency projects. Call 08600 37566, leave your name and number and an Eskom Energy Advisor will contact you. Alternatively, ask for a specific advisor to contact you. Visit www.eskom.co.za/idm for more information. Credits: www.emersonindustrial.com S. Nadel, N. Elliott, Overview of programmes to promote energy efficient motor systems in the United States, in: Energy Efficiency Improvements in Electric Motors and Drives, Springer, 1997, pp. 365-376 www.wseas.org Issued by Eskom Integrated Demand Management October 2015 Eskom Holdings SOC Ltd Reg No 2002/015527/30