QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Similar documents
QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

for relative humidity and temperature

for relative humidity and temperature

Duct Temperature Sensors

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Duct Air Quality Sensors

for relative humidity and temperature with calibration certificates

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room Temperature Sensors

QPM21 Series Duct CO 2 and Air Quality Sensors

Duct Temperature Sensors

Room Air Quality Sensors

Room air quality sensors

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

PRELIMINARY EDITION

Differential pressure sensors

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Room Temperature Controller

Immersion Temperature Controller

Room Temperature Controller

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Room Temperature Sensors

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Hygro/hygrothermal transducers (hygrometric)

Heating Controller. Building Technologies HVAC Products. Synco 700

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Flame Safeguards LFE10. Building Technologies HVAC Products

Room Temperature Controller with LCD

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Frost Protection Thermostat

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Flame Safeguards LFE10. Building Technologies HVAC Products

UV Flame Supervision System

RVP310. Heating Controller. Building Technologies HVAC Products

MANDÍK MEASUREMENT AND CONTROL SYSTEM

Hygro/hygrothermal transducers (hygrometric)

LAE10 LFE10. Use. Series 02

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Semi flush-mount room thermostat

Use. Functions. Key function. Other functions

RVL479. Heating Controller. for use with a partner unit

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

No. Icon Name Function

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Infrared Flame Detectors

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Room Temperature Controllers

RVL470. Heating Controller. Use. Functions. Series B

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Preliminary Release. Room Temperature

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Room Temperature Sensor

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

C Note! LGI16... Burner Controls. Building Technologies

Self-learning Room Temperature Controller

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

RVL481. Heating Controller. including d.h.w. heating

RVL480. Heating Controller

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

02/11/2015

QRA10... QRA53... QRA55...

More Precision. indusensor // Linear inductive displacement sensors

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Flame detector. The QRA4.U is for use with the following types of burner control:

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

SIMRAD GD10PE IR GAS DETECTOR

LC1350 Level Controller

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Heating Controller. Synco 700

Operating Manual MS220DA

Burner Management System

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

HYGROPHIL H process hygrometer

Conductive Leakage detectors of the Leckstar range

Room Temperature Controller

More Precision. indusensor // Linear inductive displacement sensors

Boiler Sequence Controller

District heating controller

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Transcription:

1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21... Use Type summary Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity Signal output DC 0...10 V or T1 or LG-Ni 1000 for temperature Measuring accuracy ±3 % relative humidity within the comfort range The QFM21 duct sensors are for use in air ducts of ventilation and air conditioning plants for acquiring: The relative humidity and The temperature The sensors are used as: Control sensors in the supply or extract air Reference sensor, e.g. for shifting the dew point Limit sensor, e.g. in connection with steam humidifiers Limit sensor, e.g. for measured value indication or for connection to a building automation and control system Sensor for enthalpy and absolute humidity, together with the AQF61.1 (refer to Data Sheet N1899) or SEZ222 (refer to Data Sheet N5146) Type reference measuring range signal output measuring range signal output QFM2100 None None 0...100 % Active, DC 0...10 V QFM2120 35...+60 C Passive, LG-Ni 1000 0...100 % Active, DC 0...10 V QFM2140 35...+60 C Passive, T1 (PTC) 0...100 % Active, DC 0...10 V QFM2160 0...50 C or 35...+35 C Active, DC 0...10 V 0...100 % Active, DC 0...10 V CE1N1864en 27.04.2004 Siemens Building Technologies HVAC Products

Ordering and delivery When ordering, please give name and type reference, e.g.: Duct sensor QFM2120 The sensor is supplied complete with mounting flange and cable entry gland M16. Equipment combinations All systems or devices capable of acquiring and handling the sensor s DC 0...10 V or 4...20 ma output signal. Function Relative humidity The sensor acquires the relative humidity in the air duct via its capacitive humidity sensing element whose electrical capacitance changes as a function of the relative humidity. The electronic measuring circuit converts the sensor s signal to a continuous DC 0...10 V signal, which corresponds to 0...100 % relative humidity. In the range 0...9. ( 0...95 % r. h.), the signal is linear to the measuring accuracy given in Technical data, resulting in an effective measuring range of 0 95 % r.h. The sensor acquires the temperature in the air duct via its sensing element whose electrical resistance changes as a function of the temperature. Depending on the type of sensor, this change in resistance is converted either to an active DC0 10 V output signal ( 0 50 C or 35 +35 C) or is provided as a passive output signal ( 35 60 C). Sensing elements, simulated LG-Ni 1000 Characteristic: R [Ω] 1400 1811D01 1200 1000 800 600 ϑ 50 40 30 20 10 0 10 20 30 40 50 60 70 80 [ C] T1 (PTC) R [Ω] 3200 3000 2800 2600 1864D01 2400 2200 2000 1800 1600 1400 ϑ 40 30 20 10 0 10 20 30 40 50 60 70 80 [ C] Legend R ϑ Resistance value in Ohm in degrees Celsius 2/6

Mechanical design The duct sensor consists of housing, printed circuit board, connection terminals, mounting flange and immersion rod with measuring probe. The 2-sectional housing is comprised of base and removable cover (snap-on design). The measuring circuit and the setting element are located on the printed circuit board inside the cover, the connection terminals on the base. The sensing elements are located at the end of the measuring probe and protected by the filter cap. Cable entry is made via the cable entry gland M16 (IP 54) supplied with the sensor, which can be screwed into the housing. Immersion rod and housing are made of plastic and rigidly connected. The sensor is designed for screwed or flanged mounting. It can be fitted as follows: With the mounting flange supplied with the sensor (recommended), which is to be fitted to the sensor and then secured in accordance with the required immersion length, or Without mounting flange (making use of the maximum immersion length). For that propose, the housing has 4 holes for fitting the sensor directly to the air duct Setting element Range 1 2 3 Messbereich 123 Testfunktion aktiv U1 U2 BS-MS 10 V 0 V 10 V 20 C 75 C 20 C 0 V 35 C 1864Z05 The setting element is located inside the cover. It consists of 6 pins and a shorting plug. It is used to select the required measuring range and to activate the test function. The different plug positions have the following meaning For the passive temperature measuring range: Shorting plug in the mid position (R2) = 35...+60 C (factory setting) For the activating temperature measuring range: Shorting plug in the left position (R1) = 35...+35 C, Shorting plug in the mid position (R2) = 0...50 C (factory setting), Shorting plug in the right position (R3) = 0...50 C For activating the test function: Shorting plug in the horizontal position: The values according to the table "Test function active" will be made available at the signal output. Fault Should the temperature sensor become faulty, there will be a voltage of 0 V at signal output U2 or signal output BS-MS 35 C, and the humidity signal at signal output U1 will reach 10 V Should the humidity sensor become faulty, there will be a voltage of 10 V at signal output U1 after 60 seconds, and the temperature signal will remain active Accessories (for replacement) Name Filter cap Type reference AQF3101 3/6

Engineering notes To power the sensor, a transformer for safety extra low-voltage (SELV) with separate windings for 100 % duty is required. When sizing and protecting the transformer, the local safety regulations must be observed. When sizing the transformer, the power consumption of the duct sensor must be taken into consideration. For correct wiring of the sensor, refer to the Data Sheets of the devices with which the sensor is used. The permissible line lengths must be observed. Cable routing and cable selection When laying the cables, it must be observed that the longer the cables run side by side and the smaller the distance between them, the greater the electrical interference. Shielded cables must be used in environments with EMC problems. Twisted pair cables are required for the secondary supply lines and the signal lines. Mounting notes To ensure degree of protection IP 54, the sensor must be fitted with the cable entry pointing downward! The sensor must be mounted in locations where it can be easily accessed for service. Note! If used in connection with steam humidifiers, the distance to the humidifier must be a minimum of 3 m. If permitted by the installation, the distance should be as great as possible, but no more than 10 m The sensing elements in the immersion rod are susceptible to impact and shock. Any impact or shock should therefore be avoided If the application involves dew point shifting, the sensor must be mounted in the extract air duct. Mounting Instructions are printed on the package. Commissioning notes Check wiring before switching on power. The temperature measuring range must be selected on the sensor, if required. Technical data Power supply Line lengths for the measuring signal, terminal U1, U2 Cable lengths for measuring signal terminals BS-MS Functional data of humidity sensor Operating voltage Frequency Power consumption Perm. cable lengths Copper cable 0.6 mm dia. Copper cable 1 mm 2 Copper cable 1.5 mm 2 Perm. cable lengths Measuring range Measuring accuracy at 23 C 0...95 % r.h. 30...70 % r.h. dependency Time constant at 0...50 C and 10...80 % r. h. Perm. air velocity AC 24 V ±20 % or DC 13.5...3 50/60 Hz 1 VA 50 m 150 m 300 m refer to Data Sheet of the device handling the signal refer to "Type summary" ±5 % ±3 %, typically 0.1 % r. h./ C approx. 20 s, in moving air 20 m/s Output signal, linear (terminal U1) DC 0...9. 0...95 % r. h., max. ±1 ma 4/6

Functional data of temperature sensor with QFM2160 Functional data of temperature sensor with QFM2120, QFM2140 Protective data Electrical connections Environmental conditions Materials and colors Measuring range 0...50 C / 35...+35 C Sensing element NTC 10 kω Measuring accuracy at 15...35 C 35...+50 C ±0.8 K ±1 K Time constant approx. 20 s, in moving air Output signal, linear (terminal U2) DC 0...10 V 0...50 C / 35...+35 C max. ±1 ma Measuring range 35...+60 C Sensing element simulated, corresponding to QFM2120 QFM2140 Measuring accuracy at 15...35 C 35...+60 C Time constant LG-Ni 1000 T1 (PTC) ±0.8 K ±1 K approx. 20 s, in moving air Degree of protection of housing IP 54 to IEC 529 Safety class III to EN 60 730 Connection terminals for 1 2.5 mm 2 or 2 1.5 mm 2 Cable entry gland (enclosed) M 16 x 1.5 Operation Climatic conditions (housing with electronic) Mechanical conditions Transport Climatic conditions Mechanical conditions Base Cover Immersion rod Filter cap Mounting flange Cable entry gland Sensor (complete assembly) Packaging IEC 721-3-3 class 3K5 15...+60 C 0...95 % r. h. (non-condensing) class 3M2 IEC 721-3-2 class 2K3 25...+70 C <95 % r. h. class 2M2 polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7035 (light-grey) polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7001 (silver-grey) PA 66(black) PA, RAL 7035 (light-grey) silicone-free corrugated cardboard Standards Weight Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Immunity Emissions conformity to conformity to Australian EMC Framework Radio Interference Emission Standard Incl. packaging QFM2100 QFM2120 QFM2140 QFM2160 EN 61 000-6-1 EN 61 000-6-3 EMC Directive 89/336/EEC Radio Communication Act 1992 AS/NZS 3548 5/6

Connection terminals QFM2160 QFM2120, QFM2140 QFM2100 G (R1 = 35...+35 C / (r.h.) R2 = 0...50 C) G0 U1 U2 1864G01 G (R2 = 35...+60 C) (r.h.) G0 U1 BS MS 1864G02 G G0 (r.h.) U1 1864G03 G, G0 Operating voltage AC 24 V (SELV) or DC 13.5...3 U1 Signal output DC 0...9. for relative humidity 0...95 % U2 Signal output DC 0...10 V for temperature range 0...50 C or 35...+ 35 C BS, MS Signal output for temperature range 35...+ 60 C (passive); the wires must not be interchanged Dimensions (in mm) 80 60 28 39 28 3 14,5 M16 x 1,5 222 183 ø 20 ø 15 80 50 (41) max. 154 1864M01 (62,8) 21(16) 60 Drilling template with (without) mounting flange 6/6 2004 Siemens Building Technologies AG Subject to change