Room air quality sensors

Duct Air Quality Sensors

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

QPM21 Series Duct CO 2 and Air Quality Sensors

Room Temperature Sensors

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

for relative humidity and temperature with calibration certificates

Duct Temperature Sensors

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Duct sensors. Symaro. for relative humidity and temperature

for relative humidity and temperature

for relative humidity and temperature

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room Temperature Sensors

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Room Temperature Sensor

Room Temperature Controller

Indoor Air Quality Controller

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Semi flush-mount room thermostat

Room Temperature Controller

Room Temperature Controller with LCD

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

PRELIMINARY EDITION

Preliminary Release. Room Temperature

Room thermostats with LCD for wall mounting

Room Temperature Controllers

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Differential pressure sensors

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Duct Temperature Sensors

Flush-mounted room thermostat

Room Temperature Controller

Use. For 2-pipe fan coils

Self-learning Room Temperature Controller

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Flush-mounted room thermostats

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

Immersion Temperature Controller

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Wireless room thermostat with LCD

Wall-mounted room thermostat with LCD

No. Icon Name Function

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

RVL479. Heating Controller. for use with a partner unit

Room thermostat with Auto Timer, Option External Input

Flame Safeguards LFE10. Building Technologies HVAC Products

UV Flame Supervision System

Room thermostat with 24-hour time switch and large LCD

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Semi flush-mount room thermostats

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Room Unit. Building Technologies SYNERGYR

Flame Safeguards LFE10. Building Technologies HVAC Products

QAW70. Room Unit. Building Technologies. for use with heating controllers

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

RVP310. Heating Controller. Building Technologies HVAC Products

Room thermostat with Auto Timer, Option External Input

Room thermostats with LCD RDD100..

Self-learning Room Temperature Controller

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

RVL481. Heating Controller. including d.h.w. heating

Room thermostat with Auto Timer, Option External Input

Indoor Air Quality Controller

Heating Element. Building Technologies HVAC Products

Self-learning Room Temperature Controller

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Self-learning Room Temperature Controller

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

RVL480. Heating Controller

Heating Controller. Building Technologies HVAC Products. Synco 700

Flame detector. The QRA4.U is for use with the following types of burner control:

Frost Protection Thermostat

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

SIMRAD GD10PE IR GAS DETECTOR

LAE10 LFE10. Use. Series 02

Flame detector. Building Technologies Division Infrastructure & Cities Sector

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Flame detector. The QRA4.U is for use with the following types of burner control:

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

ECO ROOF FAN. A modern, energy-saving roof fan with a DC motor. INSTALLER Register the roof fan for an extended 5 year guarantee!

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

Semi flush-mount communicating room thermostats

Application guide RDG160 Remote control

Transcription:

1 961 1961P1 1961P2 QPA2 QPA2D Room Air Quality Sensors QPA2 With maintenance-free photoacoustic CO 2 sensing element and depending on the type of sensor VOC 1) sensing element, based on a heated tin dioxide semiconductor CO 2 temperature and CO 2 humidity-temperature multisensor No recalibrations required Operating voltage AC 24 V or DC 13535 V Signal outputs DC 1 V 1) VOC = volatile organic compounds (also called mixed gas) Use In ventilation and air conditioning plant to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation The sensor acquires: CO 2 concentrations as an indication of occupancy in rooms where smoking is prohibited VOC concentrations as an indication of odors in the room, such as tobacco smoke, body odor, or material fumes The relative humidity in the room The room temperature The QPA2 can be used as a: Control sensor Transmitter for building automation and control systems and / or display units Typical use: Acquisition of CO 2 and VOC concentrations: In party rooms, lounges, fair pavillions and exhibition halls, restaurants, canteens, shopping malls, sports gymnasiums, sales rooms, and conference rooms Acquisition of CO 2 concentrations: In rooms with varying occupancy levels where smoking is prohibited, such as museums, theatres, movie theatres, auditoriums, office spaces, and school rooms CE1N1961en 22725 Siemens Building Technologies HVAC Products

Important! The QPA2 sensors are not suited for use as safety devices, such as gas or smoke warning devices! Type summary Type reference CO 2 measuring range VOC sensitivity Temperature measuring range Humidity measuring range Display of measured value QPA2 2 ppm --- --- --- No QPA22 2 ppm Low (R1) Normal (R2) High (R3) QPA22D 2 ppm Low (R1) Normal (R2) High (R3) --- --- No --- --- Yes QPA26 2 ppm --- 5 C / 35+35 C --- No QPA26D 2 ppm --- 5 C / 35+35 C --- Yes QPA262 1) 2 ppm --- 5 C / 35+35 C 1 % No QPA262D 1) 2 ppm --- 5 C / 35+35 C 1 % Yes Ordering Equipment combinations 1) Available from March 26 When ordering, please give name and type reference, eg: Room air quality sensor QPA22 The QPA2 are suited for use with all types of systems and devices capable of acquiring and handling the DC 1 V output signal delivered by the sensor Mode of operation CO 2 concentrations Function diagram CO 2 (output U1) CO 2 /VOC concentration only with QPA22 and QPA22D Ventilation demand diagram (output U2) The sensor acquires and evaluates the CO 2 concentration The resulting output signal of DC 1 V is proportional to the CO 2 content of the ambient air 1 8 6 4 2 U1 [V] 4 8 12 16 2 1961D1 CO 2 [ppm] The sensor acquires and evaluates the CO 2 / VOC concentration and transforms it to a ventilation demand signal It represents the result of maximum selection of the CO 2 measuring signal and the filtered VOC measuring signal With maximum selection, the 2 demand signals are compared and depending on the result and the selected VOC sensitivity delivered as the common air quality demand The ventilation demand signal is delivered via output U2 as a DC 1 V signal to be fed to the ventilation controller 1 8 6 4 2 U2 [V] 4 8 12 16 2 1961D2 Max (CO 2, VOC) [ppm*] 2/6 Siemens Building Technologies Indoor air quality sensors QPA2 CE1N1961en HVAC Products 22725

VOC sensitivity Response time "VOC signal" Relative humidity only with QPA262 and QPA262D Temperature only with QPA26 Mechanical design Using the shorting plug on the setting element for the measuring range, the impact of VOC ventilation demand on maximum selection against CO 2 ventilation demand can be changed The position in the middle (R2) produces normal sensitivity of the VOC signal (factory setting) The 2 other positions are used for increasing (R3) or decreasing (R1) VOC sensitivity Before the processor handles a change of the measured VOC value for maximum selection, a response time of 3 minutes for every Volt the signal value changes is observed The sensor acquires the relative humidity in the room with a capacitive humidity sensing element whose capacitance changes as a function of the relative humidity An electronic measuring circuit converts the signal from the sensing element to a continuous DC 1 V signal, corresponding to a relative humidity range of 1 % The sensor acquires the room temperature with a sensing element whose electrical resistance changes as a function of the temperature The change is converted to an active DC 1 V output signal ( 5 C or 35+35 C) The units have been designed for wall mounting They are suited for use with most types of commercially available recessed conduit boxes The cables can be introduced from the rear (concealed wiring) or from below or above (surface-run wires) through knockout openings The units consist of 2 major sections: Casing and baseplate Both snap together but can be detached again The measuring circuit, the sensing elements and the setting elements are located on a printed circuit board inside the unit The mounting base carries the connection terminals Setting elements R1 R2 R3 F C X4 X17 Measuring range R1 R2 R3 1 3 5 1 3 F C 2 4 6 Temperature unit 2 4 1 3 5 1 3 5 1 3 5 1 3 5 Test function active X4 U1 U2 X17 U3 2 4 6 2 4 6 2 4 6 2 4 6 5 V V V 5 V 5 V 1 V 1 V 5 V 1 3 5 1 3 5 1 3 5 1 3 5 2 4 6 2 4 6 2 4 6 2 4 6 5 V V 5 V 1 V 1961Z2en The setting elements can be accessed after removing the mounting base for the measuring range with QPA2 Meaning of the different shorting plug positions: For the CO 2 measuring range: Shorting plug in the mid position (R2) = 2 ppm (factory setting) with QPA22 and QPA22D For CO 2 / VOC weighting: Shorting plug in the upper position (R1) = VOC sensitivity "low" Shorting plug in the mid position (R2) = VOC sensitivity "normal" (factory setting) Shorting plug in the lower position (R3) = VOC sensitivity "high" Siemens Building Technologies Indoor air quality sensors QPA2 CE1N1961en HVAC Products 22725 3/6

with QPA26 for the active test function for changeover of the temperature display Behavior in the event of fault All types QPA22 QPA26 and QPA26D QPA262 and QPA262D Display of measured values Disposal Engineering notes For the temperature measuring range: Shorting plug in the upper position (R1) = 35+35 C Shorting plug in the mid position (R2) = 5 C (factory setting) Shorting plug in the lower position (R3) = 5 C Shorting plug for the measuring range in the vertical position: The signal output delivers the values according to table "Test function active" Meaning of the different shorting plug positions: For the unit of temperature: Shorting plug in the horizontal, lower position = C (factory setting) Shorting plug in the horizont, upper position = F In the event of CO 2 failure, 1 V will be present at signal output U1 (after 6 seconds) In the event of CO 2 or VOC failure, 1 V will be present at signal output U2 (after 6 seconds) Should the temperature sensor become faulty, V will be present at signal output U2 Should the temperature sensor become faulty, V will be present at signal output U3, and the humidity signal at signal output U2 will increase to 1 V (after 6 seconds) Should the humidity sensor become faulty, 1 V will be present at signal output U2 (after 6 seconds), and the temperature signal will remain active With sensors type QPA22D, QPA26D and QPA262D, the measured values can be read off from an LCD The following measured values are displayed: CO 2 : In ppm CO 2 + VOC: As a bar chart (4 bars U2 = 2 V, 2 bars U2 = 1 V) Temperature: In C or F Humidity: In % The major plastic components bear the material references in compliance with ISO / DIS 11 469 to facilitate environment-friendly disposal Cable routing and cable selection Mounting notes Mounting location Mounting Instructions The sensor must be powered by a transformer for safety extra low-voltage (SELV) with separate windings, suited for 1 % duty It must be sized and fused in compliance with local safety regulations When sizing the transformer, the power consumption of the sensor must be taken into consideration For information about wiring, refer to the Data Sheets of the devices with which the sensor is used The maximum permissible cable lengths must be observed When laying the cables, it should be considered that electrical interference is the greater the longer the cables run parallel and the smaller the distance between them On applications with EMC problems, shielded cables should be used For the secondary power lines and signal lines, use cables with twisted pairs Inner wall of the room to be ventilated, not in niches, not behind curtains, not above or near heat sources, and not exposed to direct light from spot lights The sensor must not be exposed to direct solar radiation The end of the conduit at the sensor must be sealed to prevent false measurements due to drafts through the conduit Mounting Instructions are enclosed in the package 4/6 Siemens Building Technologies Indoor air quality sensors QPA2 CE1N1961en HVAC Products 22725

Commissioning notes The sensor s functions can be checked 3 minutes after applying power: Checking the CO 2 function: In well ventilated rooms, the sensor shows the CO 2 concentration of the outside air Typically, this is 36 ppm (the sensor s measuring accuracy must be considered) Also, a basic functional check can be made by exhaling on the sensor In that case, it must be taken into account that the sensor s rate of response has been purposely delayed (time constant t 9 = 5 min) Checking the VOC function: Touch the sensor with a cotton ball dowsed in alcohol (eg gas from a cigarette lighter, without lighting a flame) Ventilation should start when the preset switching level of the connected controller is reached After applying power to the types of sensor with display, Init will appear for about 6 seconds Technical data Power supply Cable lengths for measuring signal Functional data "CO 2 " Functional data "Maximum selection of CO 2 and VOC" with QPA22 and QPA22D Functional data "rh" with QPA262 and QPA262D Functional data "Temperature" with QPA26 Display of measured value Protective data Electrical connections Environmental conditions Operating voltage (SELV) Frequency Power consumption AC 24 V ± 2 % or DC13535 V 5 / 6 Hz at AC 24 V 2 VA Perm cable lengths refer to Data Sheet of the device handling the signal Measuring range (MW = measured value) 2 ppm 1) Measuring accuracy at 2 C, 4 % rh and 97 hpa ±(2 ppm 1) + 15 % MW) Temperature dependency in the range of 1535 C ±4 % MW Repeatability ±2 ppm 1) Long-time drift Time constant t 9 ±2 ppm 1) pa <5 min Output signal, linear (terminal U1) DC 1 V 2 ppm 1), max ± 1 ma Recalibration-free 8 years Measuring range 2 ppm 1) VOC sensitivity refer to "Type summary" Output signal, linear (terminal U2) DC 1 V 2 ppm 1), max ± 1 ma Response time "VOC signal" t VOC Range of use Measuring range Measuring accuracy at 23 C and AC 24 V 95 % rh 37 % rh Temperature dependency Time constant 3 min / V 95 % rh (noncondensing) 1 % rh ± 5 % rh ± 3 % rh (typically) 1 % rh / C 2 min Output signal, linear (terminal U2) DC 1 V 1 % rh, max ± 1 ma Measuring range Measuring element Measuring accuracy in the range of 1535 C 35+5 C Time constant 5 C (R2, R3) or 35+ 35 C (R1) NTC 1 kω ± 8 K ± 1 K 7 min Output signal, linear (terminal U2 or U3) DC 1 V 5 C / 35+ 35 C max ± 1 ma With QPA22D, QPA26D, QPA262D LCD Degree of protection of housing IP 3 to IEC 529 Safety class III to EN 6 73 Screw terminals for 1 25 mm 2 or 2 15 mm 2 Operation to Climatic conditions Temperature (housing incl electronics) Humidity Mechanical conditions IEC 721-3-3 class 3K3 5 C 95 % rh (noncondensing) class 3M2 5/6 Siemens Building Technologies Indoor air quality sensors QPA2 CE1N1961en HVAC Products 22725

Materials and colors Standards Weight Connection terminals Transport to Climatic conditions Temperature Humidity Mechanical conditions Cover Housing Mounting plate Sensor (complete) Packaging Product safety Automatic electrical controls for household and similar use EN 6 73-1 Electromagnetic compatibility Immunity Emissions conformity to conformity to Australian EMC Framework Radio Interference Emission Standard Incl packaging Without display With display 1) ppm = parts per million QPA2 IEC 721-3-2 class 2K3 25+ 7 C < 95 % rh class 2M2 ASA + PC, NCS S 52- (white) ASA + PC, NCS 281-Y43R (grey) PC, NCS 281-Y43R (grey) silicone-free corrugated cardboard EN 61-6-2 EN 61-6-3 EMC directive 89/336/EEC Radio Communication Act 1992 AS / NZS 3548 approx 1 kg approx 12 kg QPA22, QPA22D CO 2 CO 2 CO 2 / VOC U1 U1 U2 19611 QPA26, QPA26D QPA262, QPA262D R1 = -35+35 C / CO 2 R2 = 5 C CO 2 rh U1 U2 U1 U2 19613 19612 R1 = -35+35 C / R2 = 5 C U3 19614 Dimensions (in mm), System potential AC 24 V (SELV) or DC 13535 V System neutral and measuring neutral U1 Signal output DC 1 V U2 Signal output DC 1 V U3 Signal output DC 1 V 4,2 9,5 1 56 6 9 36 56 6 1961M1 Drilling plan 6/6 25 Siemens Switzerland Ltd Subject to change Siemens Building Technologies Indoor air quality sensors QPA2 CE1N1961en HVAC Products 22725