QFM21... Duct sensors. Symaro. for relative humidity and temperature

Similar documents
QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Duct Temperature Sensors

for relative humidity and temperature

for relative humidity and temperature

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Duct Air Quality Sensors

Room Temperature Sensors

Duct Temperature Sensors

for relative humidity and temperature with calibration certificates

QPM21 Series Duct CO 2 and Air Quality Sensors

Room Air Quality Sensors

Room air quality sensors

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

PRELIMINARY EDITION

Immersion Temperature Controller

Room Temperature Controller

Hygro/hygrothermal transducers (hygrometric)

Room Temperature Sensors

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Differential pressure sensors

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Room Temperature Controller

Room Temperature Controllers

Semi flush-mount room thermostat

Heating Controller. Building Technologies HVAC Products. Synco 700

Frost Protection Thermostat

MANDÍK MEASUREMENT AND CONTROL SYSTEM

Hygro/hygrothermal transducers (hygrometric)

RVL479. Heating Controller. for use with a partner unit

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

02/11/2015

Room Temperature Controller with LCD

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Frost Units for air temperature monitoring

Room Temperature Controller

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

No. Icon Name Function

Infrared Flame Detectors

Room thermostats with LCD for wall mounting

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

Operating Manual MS220DA

M7100 Pressure Transducer

RVL480. Heating Controller

Flame Safeguards LFE10. Building Technologies HVAC Products

RVL481. Heating Controller. including d.h.w. heating

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Use. Functions. Key function. Other functions

Use. For 2-pipe fan coils

Wall-mounted room thermostat with LCD

02/11/2015

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

District heating controller

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Boiler Sequence Controller

LC1350 Level Controller

C Note! LGI16... Burner Controls. Building Technologies

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

RAR... Photocell Detectors. Building Technologies Division

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Flush-mounted room thermostat

Room thermostat with Auto Timer, Option External Input

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

LGA... Gas Burner Controls. Building Technologies Division

District heating controller

Preliminary Release. Room Temperature

RVP310. Heating Controller. Building Technologies HVAC Products

LAE10 LFE10. Use. Series 02

RVL470. Heating Controller. Use. Functions. Series B

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

District Heating Controller

UV Flame Supervision System

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Operating Manual MS220KA and MSR220KA

Flame Safeguards LFE10. Building Technologies HVAC Products

Heating Controller. Synco 700

OH720, OP720, HI720, HI722

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Beck. The differential pressure transmitter for air

Wireless room thermostat with LCD

HYGROPHIL H process hygrometer

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

FAST RESPONSE TEMPERATURE SENSORS 42.11a

IT system floor-standing distribution

Transcription:

1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10 V / 4 20 ma / T1 / LG-Ni 1000 for temperature Measuring accuracy ±3 % r. h. within the comfort range Range of use 15 +60 C / 0 95 % r. h. (non-condensing) Use The QFM21 duct sensors are for use in air ducts of ventilation and air conditioning plant for acquiring: The relative humidity and The temperature. The sensors are used as: Control sensors in the supply or extract air Reference sensors, e.g. for shifting the dew point Limit sensors, e.g. in connection with steam humidifiers Limit sensors, e.g. for measured value indication or for connection to a building automation and control system Sensors for enthalpy and absolute humidity, together with SEZ220 (see Data Sheet N5146) CE1N1864en 01.06.2012 Building Technologies

Type summary Type reference Temperature measuring range Temperature signal output Humidity measuring range Humidity signal output Operating voltage QFM2100 None None 0...100 % active, DC 0...10 V AC 24 V or DC 13.5 35 V QFM2101 None None 0...100 % active, 4 20 ma DC 13.5 35 V QFM2120 35...+ 5 0 C passive, LG-Ni 1000 0...100 % active, DC 0...10 V AC 24 V or DC 13.5 35 V QFM2140 35...+ 5 0 C passive, T1 (PTC) 0...100 % active, DC 0...10 V AC 24 V or DC 13.5 35 V QFM2160 0...50 C / 35...+ 35 C active, DC 0...10 V 0...100 % active, DC 0...10 V AC 24 V or DC 13.5 35 V or 40...+ 70 C QFM2171 0...50 C / 35...+ 35 C or 40...+ 70 C active, 4 20 ma 0...100 % active, 4 20 ma DC 13.5 35 V Ordering and delivery When ordering, please give name and type reference, e.g.: Duct sensor QFM2120 The sensor is supplied with mounting flange and cable entry gland M16. Equipment combinations All systems and devices capable of acquiring and handling the sensor s DC 0...10 V, 4...20 ma, LG-Ni 1000 or T1 output signal. When using the sensors for minimum or maximum selection, for averageing, or to calculate enthalpy, enthalpy difference, absolute humidity, and dewpoint, we recommend to use the SEZ220 signal converter (see Data Sheet N5146). Function Relative humidity Temperature Simulated passive output signal The sensor acquires the relative humidity in the air duct via its capacitive humidity sensing element whose electrical capacitance changes as a function of the relative humidity. The electronic measuring circuit converts the sensor s signal to a continuous DC 0...10 V or 4 20 ma signal, which corresponds to 0...100 % r. h. The sensor acquires the temperature in the air duct via its sensing element whose electrical resistance changes as a function of the temperature. Depending on the type of sensor this change in resistance is converted either to an active DC 0 10 V or 4 20 ma output signal corresponding to a temperature range of 0 50 C, 35 +35 C, or 40...+70 C. The measuring range can be selected. The temperature is provided as a simulated passive LG-Ni 1000- or T1-output signal ( 35 50 C) as an alternative to the active output signal. The measuring current of systems/devices for acquiring the electrical resistance of the passive sensor differs greatly and impacts self-heating of the temperature sensing element at the end of the measuring tip. To compensate the impact, the passive output signal is simulated with an electronic circuit. 2/8

Sensing elements, simulated LG-Ni 1000 Characteristic: R [Ω] 1400 1811D01 1200 1000 800 T1 (PTC) 600 ϑ 50 40 30 20 10 0 10 20 30 40 50 60 70 80 [ C] R [Ω] 3200 3000 2800 2600 1864D01 2400 2200 2000 1800 1600 1400 ϑ 40 30 20 10 0 10 20 30 40 50 60 70 80 [ C] Legend R ϑ Resistance value in Ohm Temperature in degrees Celsius Burden diagram Output signal, terminal I1 / I2 Burden [Ohm] 900 800 700 600 500 400 300 200 100 Inadmissible range! Admissible range 0 0 10 20 30 40 Operating voltage [DC V] 1864D03en Mechanical design The duct sensor consists of a housing, a printed circuit board, connection terminals, a mounting flange and an immersion rod having a measuring tip. The 2-sectional housing comprises a base and a removable cover (snap-on design). The measuring circuit and the setting element are located on the printed circuit board inside the cover, the connection terminals on the base. The sensing elements are located at the end of the measuring tip and protected by a filter cap. Cable entry is made via the screwed cable gland M16 supplied with the sensor. Immersion rod and housing are made of plastic and are rigidly connected. The sensor is fitted with the mounting flange supplied with the sensor. The flange is to be placed over the immersion rod and then secured in accordance with the required immersion length. 3/8

Setting element Range 123 Measuring range 123 Test function active U1 U2 BS-MS I1 I2 10 V 5 V 20 C 20 ma 12 ma 5 V 10 V 75 C 12 ma 20 ma 0 V 5 V 5 V 0 V 20 C 35 C 4 ma 12 ma 12 ma 4 ma 1864Z05en The setting element is located inside the cover. It comprises 6 pins and a jumper. It is used to select the required measuring range and to activate the test function. The different jumper settings have the following meaning: For the passive temperature measuring range: Jumper in the middle position (R2) = 35...+50 C (factory setting) For the active temperature measuring range: Jumper in the left position (R1) = 35...+35 C, Jumper in the middle position (R2) = 0...50 C (factory setting) Jumper in the right position (R3) = 40...+70 C For activating the test function: Jumper in the horizontal position: The values according to the table "Test function active" will be made available at the signal output. Malfunction Should the temperature sensor become faulty a voltage of 0 V (4 ma) will be applied at signal output U2 (I2) or signal output BS-MS becomes high impedance (>1 MΩ) after 60 seconds, and the humidity signal at signal output U1 (I1) will reach 10 V (20 ma). Should the humidity sensor become faulty a voltage of 10 V (20 ma) will be applied at signal output U1 (I1) after 60 seconds, and the temperature signal will remain active. Accessories Name Filter cap (for replacement) Type reference AQF3101 Engineering notes Cable routing and cable selection Note to QFM2171 A transformer for safety extra low-voltage (SELV) with separate windings for 100 % duty is required to power the sensor. When sizing and protecting the transformer, local safety regulations must be complied with. When sizing the transformer, the power consumption of the duct sensor must be taken into consideration. For correct wiring, refer to the Data Sheets of the devices with which the sensor is used. The permissible cable lengths must be considered. It must be considered for routing of cables that the longer the cables run side by side and the smaller the distance between them, the greater electrical interference. Shielded cables must be used in environments with EMC problems. Twisted pair cables are required for the secondary supply lines and the signal lines. Terminals G1(+) and I1( ) of the humidity output must always be connected to power, even if only terminals G2(+) and I2( ) of the temperature output are used! 4/8

Mounting notes Location Caution! Mounting instructions Mount the sensor in the center of the duct wall. If used together with steam humidifiers, the minimum distance after the humidifier must be 3 m to max 10 m. Fit the sensor in the extract air duct if the application involves dew point shifting. Fit only the flange to the duct wall. The sensor is then inserted through the flange and engaged. To ensure degree of protection IP 54, fit the sensor with the cable entry pointing downward. The sensing elements inside the measuring tip are sensitive to impact. Avoid any impact on mounting. The mounting instructions are printed on the inside of the package of the device. Commissioning notes Check wiring before switching on power. The temperature measuring range must be selected on the sensor, if required. Wiring and the output signals can be checked by making use of the test function (refer to "Mechanical design"). We recommend not to use voltmeters or ohmmeters directly at the sensing element. In the case of the simulated passive output signals, measurements with commercially available meters cannot be made (measuring current too small). Technical data Power supply Cable lengths for measuring signal Functional data of humidity sensor Functional data of temperature sensor with QFM2160, QFM2171 Operating voltage AC 24 V ±20 % or DC 13.5...35 V Frequency 50/60 Hz at AC 24 V Power consumption 1 VA Perm. cable lengths See data sheet of the device handling the signal Range of use 0 95 % r. h. (non-condensing) Measuring range 0 100 % r. h. Measuring accuracy at 23 C and AC/DC 24 V in 0...95 % r. h. 30...70 % r. h. ±5 % r. h. ±3 %, r. h. typically Temperature dependency 0.1 % r. h./ C Time constant at 0...50 C and 10...80 % r.h. < 20 s Perm. air velocity 20 m/s Output signal, linear (terminal U1) DC 0...10 V 0...100 % r. h., max. ±1 ma Output signal, linear (terminal I1) Burden Measuring range Sensing element Measuring accuracy at AC/DC 24 V in 15...35 C 35...+50 C Time constant 4 20 ma 0...100 % r. h. See "Function" 0...50 C (R2 = factory setting), 35...+35 C (R1) or 40 +70 C (R3) NTC 10 kω ±0.8 K ±1 K < 3.5 min. in with 2 m/s moved air Output signal, linear (terminal U2) DC 0...10 V 0...50 C / 35...+35 C / 40...+70 C max. ±1 ma 5/8

Functional data of temperature sensor with QFM2120, QFM2140 Protective data Electrical connections Environmental conditions Materials and colors Standards and directives Environmental compatibility Weight Output signal, linear (terminal I2) 4 20 ma 0...50 C / 35...+35 C / 40...+70 C Burden See "Function" Measuring range 35...+50 C Sensing element simulated, corresponding to QFM2120 QFM2140 Measuring accuracy at AC/DC 24 V in the range of 15...35 C 35...+50 C Time constant Perm. measuring current with QFM2120 QFM2140 Degree of protection of housing LG-Ni 1000 T1 (PTC) ±0.8 K ±1 K < 3.5 min. in with 2 m/s moved air 1.18 4.21 ma 0.53 1.89 ma IP 54 as per IEC 60 529 in built-in state Safety class III as per EN 60 730 Connection terminals for 1 2.5 mm 2 or 2 1.5 mm 2 Cable entry gland (enclosed) M 16 x 1.5 Operation Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions Transport Climatic conditions Temperature Humidity Mechanical conditions Base Cover Immersion rod Filter cap Mounting flange Cable entry gland Sensor (complete assembly) Packaging Product standard: Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Immunity Emissions conformity to IEC 60721-3-3 Class 3K5 15...+60 C 0...95 % r. h. (non-condensing) Class 3M2 IEC 60721-3-2 Class 2K3 25...+70 C <95 % r. h. Class 2M2 Polycarbonate, RAL 7001 (silver-grey) Polycarbonate, RAL 7035 (light-grey) Polycarbonate, RAL 7001 (silver-grey) Polycarbonate, RAL 7001 (silver-grey) PA66 GF35 (black) PA, RAL 7035 (light-grey) Silicone-free Corrugated cardboard EN 61 000-6-1 EN 61 000-6-3 EMC directive 2004/108/EC C-tick conformity (EMC) to EN 61 000-6-3 conformity 1) UL 873 Environmental product declaration CE1E1864en provides information on environmentally compatible product design and assessment (RoHS compliance, composition of substances, packaging, environmental benefit, disposal). Incl. packaging QFM21 ISO 14001 (environment) ISO 9001 (quality) SN 36350 (environmental comp. products) RL 2002/95/EC (RoHS) Approx. 0.18 kg 1) Does not apply to the QFM2160 duct sensor! 6/8

Connection terminals QFM2160 QFM2120, QFM2140 QFM2100 G (R1 = 35...+35 C / R2 = 0...50 C / (r.h.) R3 = 40...+70 C) G0 U1 U2 1864G01 G (R2 = 35...+50 C) (r.h.) G0 U1 BS MS 1864G02 G G0 (r.h.) U1 1864G03 QFM2101 QFM2171 G1 (r.h.) I1 1864G04 G1 G2 (r.h.) (R1 = 35...+35 C / R2 = 0...50 C / I1 R3 = 40...+70 C) I2 1864G05 G, G0 Operating voltage AC 24 V (SELV) or DC 13.5...35 V G1, G2 Operating voltage DC 13.5...35 V U1 Signal output DC 0...10 V for 0...100 % r. h. U2 Signal output DC 0...10 V for temperature range 0...50 C (R2 = factory setting), 35...+ 35 C (R1) or 40...+ 70 C (R3) I1 Signal output 4 20 ma for 0...100 % r. h. I2 Signal output 4 20 ma for temperature range 0...50 C (R2 = factory setting), 35...+ 35 C (R1) or 40...+ 70 C (R3) BS, MS Signal output LG-Ni 1000- or T1 for temperature range 35...+ 50 C (passive, simulated); wires must not be interchanged Note on connection terminals of the QFM2171: Terminals G1(+) and I1 ( ) for the humidity output must always be connected to power, even if only the temperature output G2 (+) and I2 ( ) is used! 7/8

Dimensions 80 60 28 28 3 14,5 39 M16 x 1,5 222 ø 20 80 50 183 ø 15 (41) min. 90, max. 154 1864M01 (62,8) 21(16) 60 Drilling plan with (without) mounting flange Dimensions in mm 8/8 2006-2012Siemens Switzerland Ltd. Subject to change