PumpLab TM Operator s Manual

Similar documents
EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No Revised: February 2009

Manual for MC21A SETUP INSTRUCTIONS

Sacksafoam Heli-Case Operations Manual - Version A Issue Date: April 2017 PLEASE READ BEFORE USING

BACK WASH INSIDE THE SPA

Instruction Manual. Bucket Oil Pump

Sirius Technologies, Inc.

QIAcube HT Unpacking and Installation Instructions

18 INCHES, OSCILLATING STAND FAN

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

OPERATIONS MAINTENANCE MANUAL

Manual for MC91 SETUP INSTRUCTIONS

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-10 AseptiMini Pneumatic Portable Dental System

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

Manual for MC37/MFC3600

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

Read All Instructions Thoroughly Before Installing or Using the Disposer.

Instruction Manual. Cheese Warmer with Pump

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea

INSTRUCTIONS FOR OPERATION AND CARE OF

Food Waste Disposer Instruction Manual

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Econo-16 Models 2024EX, 2024STX 16oz. Popcorn Machine Instruction Manual

Experiment 4: Temperature Control of Heat Exchanger ( TBC 1/21/2012, 2/11/2017 )

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX

Mobile Evaporative Cooler. Use & Care Guide MC37 / MC61 INDEX

Manual update 2016 MC37/MFC3600

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

918 Clock Gauge Installation, Operation, and Maintenance Instructions

Oil and Water Retort Instruction Manual

Citation Models #2001, 2001ST, 2001BN Instruction Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

16 Stand Fan with Remote Control Model No: FS3-40R-30

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Bag-In-A-Box Oil Pump System

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Instruction Manual. Nacho Cheese Dispenser and Warmer

POWERCLEAN. Vacuum USER GUIDE 1305, 1306, 1645, 1646, 1647 SERIES. For How-To videos, go to

OPERATING MANUAL 12 AXIAL FANS

JOVY SYSTEMS RE-7500 User Manual Rev Index

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

FROZEN CONCOCTION MAKER

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

Your electrician must furnish sufficient voltage levels, and current for proper operation of your machine. We recommend this machine be on a

Installation. Leveling

OPERATING MANUAL/ INSTALLATION

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

B.I.C.A Built-In Coffee Appliance

MICRO SWITCH NT Series

CER-1 & CER-2 Installation & Testing Instructions

FLUSH WATER SAVER DUAL FLUSH KIT

Eldex Column Heater. Operator s Manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

AQUAPEUTICS MONACO INSTALLATION MANUAL

HW-17 Record Cleaning Machine Setup and Instruction Manual

Control Panel For Water Wash Hoods AM2

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

100 Series Maxi Internal Filters

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Installing ProSeries 2004

Wax Base Heater & Dispenser

Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

USER S GUIDE. ecal lite Software Access Code included! SUBSECTION. Read Guide Before Operating Product. Save Guide For Reference.

University of Minnesota Nano Fabrication Center

SANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION

With Full Size Nozzle. Owner s Manual

INSTALLATION. Glass Panel Doors (select models) CAUTION

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual

CORNADO POPPING UNIT 36 & 48 oz. Domestic Units Instruction Manual

SAM. Interface Robot & Trainer Board. User Guide V0211

Pedestal Fan. 12 months. 3 Speed, 40cm R2000B

Eliza Hugger 56 CEILING FAN

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Routine Outdoor Helium Compressor Maintenance Instructions

Power Pack Service Manual

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

Power Pack Service Manual

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

INSTALLATION INSTRUCTIONS

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

BEFORE OPERATING THE MACHINE: WARNING

Operating Manual Model BP500 and BP500 IJ Tape Dispenser

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

OWNER S MANUAL VERSION 4.4 SERIAL # X-1 SINGLE LAYER PRESS. With EG-260 Variable Speed Grinder

EXPANDABLE 0.5W LED FRESHWATER LIGHT FIXTURES

Transcription:

PumpLab TM Operator s Manual PumpLab TM Centrifugal Flow/ Process Control System

i PumpLab TM Main Features Clear View Flow Circuit Outlet Valve Data Display/Record Flow Meter Exit Pressure Sensor Computer Drive Motor Pump Casing (Volute) Inlet Valve Inlet Pressure Sensor Strobe Light Control Key Prime Pump On/Off Switch Master Power Fluid Reservoir Drain Primer Pump Valve Impeller Spinner Tool Primer Pump Interchangeable Pump Impellers Lockable Casters

Introduction ii Thank you for displaying confidence in us by selecting the Turbine Technologies, Ltd. PumpLab system. You've just joined an ever-growing list of operators. Turbine Technologies Ltd. has a long history of strong customer support, resulting in an enviable level of operator satisfaction. We promise to do our best in assisting you with turning your new PumpLab into a true educational centerpiece. SAFETY As with any piece of laboratory equipment, basic lab safety precautions must be taken. Protective eyewear must be provided for all participants. Equipment familiarization should be completed prior to any operation.

Notifications iii Any trademarks used in this manual are the property of their respective owners. Copyright 2009 Turbine Technologies, Ltd. Copyright 2009 National Instruments Corporation

Table of Contents iv PumpLab TM Main Features...i Introduction...ii Notifications...iii Table of Contents...iv General Description...1 Shipping Information...2 Upon Delivery...2 Production Dimensions...2 Electrical Connection...3 Pump Lab Setup...4 Filling the Reservoir Tank...4 Priming the Flow Circuit...5 Changing Impellers...6 Draining Main Reservoir Tank...7 Data Acquisition...8 Software Setup and Installation...9 PumpLab Two (2) Year Limited Warranty...10 Appendix A Changing Pump Impeller...11 How to change the pump impeller...11 Priming the System...15 Appendix B Software Setup and Installation...16 Installing USB drivers...16 Installing Data Acquisition Software...18

General Description 1 PumpLab, specifically designed for educational purposes, is a self-contained centrifugal-flow pump demonstrator. This ready-to-operate, hands-on system offers students a unique new opportunity - clear visualization of pump performance and operating characteristics. Changeable impellers and a see-through flow circuit are key educational features. Lab participants can observe the entire flow path - from point of reservoir pick-up to reservoir return. Inlet and outlet valves allow for a full adjustment of system flow for the creation of pump performance maps. Cavitation can be witnessed in the pump impeller and in the clear view test section. Additional NPT threaded test ports are installed for possible dye injection, flow velocity gradient studies and turbulence demonstrations. EXPERIMENTAL OPPORTUNITIES Demonstration of pump characteristics at various speeds Development of performance maps, including surge line determination for three separate impeller designs (straight bladed, rearward swept and forward swept) Witness cavitation with electronic verification and data capture Record flow rates via the installed flow rotameter (paddle wheel type with clear housing) Determine pump power required, efficiency, volume vs. pressure relations Insert student designed impellers for testing and design verification Sensor/ software calibration studies

Shipping Information 2 Upon Delivery PumpLab is shipped in a custom built container. This crate is intended for re-use. Therefore, do not force the shipping box open. Remove the screws marked red along the perimeter of the front panel. After removing the panel, unscrew the red screws that secure the PumpLab s hold down board. Then, unlock the front casters and slide the system out of the crate or remove the crate walls from around the unit and then unlock casters and move from pallet. Please assure shipping crate is stored for future use. Once removed from its shipping container, a general inspection is necessary. Check for obvious external dents or damage that may have occurred during transit. If shipping damage is noticed, please notify us by calling 715 924 4876. Production Dimensions PumpLab TM Length: Width: Height: 29 inches 48 inches 71 inches Shipping container dimensions Length: Width: Height: 33 5/16ths inches 55 5/16ths inches 81 1/4th inches

Electrical Connection 3 Electrical connection is simple. However, it is imperative that the power connection be properly grounded (green wire). The system is pre-wired and is equipped with a 6-foot rubber electrical cord. The input electrical power required is single phase 220-240 V, 50/60 Hz. It should be protected by a standard 20 Amp circuit breaker.

Pump Lab Setup 4 Filling the Reservoir Tank Note: A quarter cup of household bleach may be added to a full reservoir tank. This will help maintain water clarity. 1. You will need to remove 3 Philip head screws located in the tanks top cover. This will allow you to remove the left half of the acrylic cover. 2. Insert hose into tank and fill the tank to within 5 inches of the top (to the base of the grey collar) 3. Re-install tank cover (replace lid and the 3 screws removed in step 1) If filling system with any other fluid besides water, please contact Turbine Technologies first.

Priming the Flow Circuit 5 1. Remove T-handle from holder (located directly below the stored impellers) 2. Insert T-handle and turn valve to clockwise stop 3. Open pump housing breather valve (located on top of the clear pump housing) 4. Turn on prime toggle switch (assure that pump inlet and outlet valves are open) 5. Close breather valve as water level reaches the top of the clear view impeller housing. If this is not done, water will spill out through the breather valve. 6. Turn master power key switch to on position 7. Press red stop button on motor controller key pad 8. Press forward button and adjust motor rpm with up and down keys 9. Turn primer pump switch off * Inlet and outlet valves can now be adjusted to vary flow parameters

Changing Impellers 6 Note: Assure that master power key switch is turned off 1. Open breather valve to allow water to return to reservoir 2. Attach supplied hose to outlet spigot at bottom of pump housing. Open valve and drain water into a bucket, sink, or drain 3. Unscrew and remove inlet elbow fitting 4. Remove 8 silver pump housing clamps 5. Carefully remove acrylic pump cover (do not drop) 6. Remove impeller change tool from front storage cabinet 7. Remove spinner by turning spinner counter clockwise with change tool while holding impeller. Pull impeller off of shaft (Be careful not to lose shaft key as you pull the pump impeller off of the shaft) 8. Remove desired impeller from storage cabinet and place onto shaft 9. Replace spinner nut and tighten with supplied change tool 10. Replace acrylic cover and 8 hold down clamps 11. Slide inlet elbow in and tighten clear, acrylic union

Draining Main Reservoir Tank 7 1. Drain pump housing as described in changing impeller section 2. Take supplied drain hose and attach to grey drain receptacle located in the front impeller storage cabinet 3. Turn drain valve to counter clockwise stop by using supplied T-handle 4. Turn on prime switch. The prime pump will pump the water through the hose into your drain/sink It is imperative for the system to be completely drained and dried prior to storage in below freezing conditions.

Data Acquisition 8 The PumpLab is equipped with a data acquisition system. This USB connected system is fully integrated and precalibrated. Industrial grade sensors measure system parameters for real time display on the provided computer. Data can be recorded for playback or follow on analysis. Data acquisition software is user configurable without programming. The data outputs are graphically depicted and include the following values: 1. Pump Inlet Pressure 2. Pump Exit Pressure 3. Flow Rate 4. Pump Torque 5. Pump RPM Two additional ports, located on the inlet and exit side of the pump, are provided for operator expansion and designed to accept thermocouples, pressure or flow transducers and other sensors as desires. The data acquisition software offers Out-of-the-Box functionality for immediate configuration, display and recording of data without the need for programming. PumpLab is delivered with all software preinstalled and calibrated. Should these settings be accidentally lost or re-set, a CD-ROM is included with copies of all factory settings.

Software Setup and Installation 9 Data acquisition for the PumpLab TM centrifugal pump system is achieved with the PumpLab TM software application. All software is preinstalled and factory verified when purchased with accompanying computer. For instructions related to manual installation please refer to Appendix B. Screenshot of the PumpLab TM PC application used for data acquisition

PumpLab Two (2) Year Limited Warranty 10 Turbine Technologies Ltd. warrants each PumpLab, of its manufacture, to be free of defects in materials and workmanship at time of shipment, and to remain in serviceable condition for a period of 2 years (24 calendar months) following date of shipment. In the event of malfunction or failure, purchaser may, at its expense, return the PumpLab to Turbine Technologies Ltd. for inspection. If, in its sole discretion, it determines that the malfunction or failure resulted from a defect in materials or workmanship, Turbine Technologies Ltd. will repair or replace any defective component(s). Specific Exceptions 1. This warranty will become void if any person has made any attempt, except those specifically authorized by Turbine Technologies Ltd. (in writing), to repair or modify the PumpLab 2. PumpLab is not offered as and shall not be construed by purchaser to be a "Consumer Product" (within the common definition or definitions of the Federal Trade Commission). 3. PumpLab is represented to be, and is offered as, experimental technology, subject to the limitations in performance and safety inherent to equipment so classified. 4. Purchaser shall be solely responsible for determining, prior to purchase, the suitability for any purpose(s) intended, of equipment offered or supplied by Turbine Technologies Ltd. 5. This Limited Warranty as written constitutes the entire warranty offered or intended, expressed or implied and is offered in lieu of all other warranties. 6. This Limited Warranty does not apply to on board hardware or software items that are covered by other OEM warranties. Examples include data acquisition software and computer hardware.

Appendix A Changing Pump Impeller 11 How to change the pump impeller Your PumpLab TM is supplied with 3 impellers with specific vane profiles; Black: Forward Swept Red: Straight Gold: Rearward Swept Each impeller can be easily changed out to allow testing of the next one. 1. For safety, turn off power master key. 2. Open Bleeder Port to allow major portion of water in piping to drain back into tank. 3. Drain the volute into a bucket by attaching included drain hose and opening volute drain valve (Bleeder Port still open). 4. Loosen the threaded pipe connection.

12 5. Loosen and remove all volute clamps by unscrewing set screws and lifting them from volute. 6. Remove volute face by grasping with two hands and pulling forward. Set carefully on a towel (next picture). 7. Locate Impeller Spinner Tool in Accessory Compartment. 8. Remove impeller spinner using spinner tool (loosen counter-clockwise). (In the event the spinner is difficult to loosen, use a block of wood to assist with removal). 9. Grasp and pull impeller from motor shaft. Retain key that is in keyway. 10. Remove new impeller from its storage peg and replace it with the pulled impeller.

13 11. Slide new impeller onto shaft, carefully aligning it with shaft key and keyway. 12. Screw on impeller spinner Clockwise. 13. Tighten with impeller tool. 14. Verify O-Ring Seal in volute face is still in place. 15. Position volute face onto volute housing.. 16. Align threaded connection and tighten clockwise. 18. Confirm clamps are properly seated. 17. Reinsert volute clamps and tighten until snug.

14 19. Close volute drain valve. 20. Be sure bleeder port plug is open.

Priming the System 15 1. Turn on power master key. 2. Turn on primer pump switch on power panel. 3. As water slowly fills inlet piping and volute, start screwing in bleeder port plug. Time it so plug is completely closed as water reaches bleeder port hole. 4. Turn Prime Pump Switch off.

Appendix B Software Setup and Installation 16 Installing USB drivers 1. Select the.inf and.sys files and copy them to a folder on your hard drive. These will be installed next. 2. Be sure the control is powered up 3. Connect the USB cable to the control. Windows should find a new USB device. 4. Install the USB drivers. a. Choose install from a list or specific location and click Next.

b. Choose Don't search I will choose the driver to install. 17 c. Click Have Disk. Then enter the location that you stored the inf and sys files (in step 3) and click Next to install the driver files.

Installing Data Acquisition Software 18 1. To install the data acquisition software, simply double click the file setup.exe in the PumpLab folder on the included CD. This will launch the installer. 2. Choose the directory locations for the installed software or use the default locations.

19 3. Accept the license agreement. 4. Click next until finished. 5. The PumpLab program will now be available from the start menu or from the shortcut icon on the desktop.