DCS-3000 AutoCure Operating Manual

Similar documents
CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Electronic Pellet Burner Controller NPBC-V3-1

B-40/B-41 Modulating Temperature Controller

Electronic Pellet Burner Controller NPBC-V3M

Dryer Controller M720

User Manual. Dryer Controller M720

DYGIZONE GJD910 Lighting Controller & Enunciator

Pioneer-R16 Gas Monitor Operator s Manual

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

Introduction. OM-THA2

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

ESSEX ENGINEERING CORPORATION

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Refrigerated air dryers

Product Manual SZ2161. Description The SZ2161 is a microprocessor-based controller designed for water source heat pump plant control applications.

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Installer Manual KNX Touchscreen Thermostat

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

Revised 12/14/2001. DC-5500 DC-5750 Operation Manual

Section 9 System Operation

EXPERT TRI-STAR. Temperature controller. User s Manual

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

OWNER S MANUAL Venstar Inc. 08/07

Autoclave Operations Manual

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

EC Series Wall Unit Humidifier

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

Installation Instructions

HEAT HEAT HEAT COOL COOL

QuadraTouch Pro Software Manual Dryer Control System

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on.

DT968C C.T. BATH CONTROLLER

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

TABLE OF CONTENTS TABLE OF CONTENTS 1

Siemens RDY2000BN. Start Up Guide

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

Product Manual SZ1144

G a

Summit 3208GLD USER MANUAL. Electronics Line

Oven Control System Operation - Ver 2.8

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3021H Non Programmable Thermostat. Table of Contents. Description. Initial Thermostat Power up

HEAT COOL. Meets Commercial California Title 24

Product Manual SZ1145

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

Operator: Save these instructions for future use!

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual

Section 8 System Operation

SSV-DC user manual. Phason

- Data Brochure Universal Reset Module 422

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

OWNER S MANUAL Venstar Inc. 08/07

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

TC-9102 Applications

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

CA5000 Liquid CO 2 Freezer Backup System

OVEN INDUSTRIES, INC.

Analog Room Pressure Monitor RPC Series

DYNATROL INSTRUCTIONS (Version 3.2)

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Table of Contents SECTION PAGE

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Digital Precise Air Control - DPAC

Carbon Monoxide Transmitter

Installation, Operating and Maintenance Manual

ADC150 Automatic Draft Control

Ammonia Leak Detector Manual

Self-learning Room Temperature Controller

CommStat 4 Controller

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

OPERATING INSTRUCTIONS

MR3CCUHV Temperature/Defrost Control

- Data Brochure Boiler Control 274

Transcription:

DCS-3000 AutoCure Operating Manual DCS-3000 AutoCure Control System 2011 110707 page 1

ABLE OF CONENS 1. Overview 2. AutoCure operation 3. Casing control 4. Set Up (Changing the way the instrument works) 5. Factory default settings 6. Alarms 7. rouble Shooting 8. Connections 9. Compatibility with previous versions 10. Aqua-Stat pulsing rates DCS-3000 AutoCure Control System 2011 110707 page 2

1. OVERVIEW he DCS-3000 AutoCure is a Supervisor Control System 1 designed to cure tobacco while requiring little operator intervention, yet giving him full control. In this technique the kiln fan runs continuously but the furnace fires only when the temperature difference between the top 2 and bottom 3 of the kiln is less than a specified amount. Initially with wet, tightly packed tobacco it is difficult for air to pass through the tobacco and the the temperature at the bottom of the kiln rises faster than at the top of the kiln. When the temperature difference between the top and bottom is greater than 5 (step 1) or 15 (step 2) 4 the furnace quits firing but the fan continues to run. As air circulation continues the top and bottom temperatures will approach each other and the furnace will fire again. With a freshly loaded kiln, the temperature advances slowly but as the tobacco dries air passes from the bottom to the top more readily and the furnace will automatically fire longer and the kiln temperature will advance faster. obacco should cure faster and more uniformly with less operator interaction than with the advance and hold method which requires an operator to estimate several times during a cure the rate that the temperature should advance. YELLOWING and ING wo step process, the first is yellowing and the second is drying. he wet bulb is controlled automatically he advance rate is determined automatically. During yellowing and drying little or no operator intervention is required although at all times the operator can make changes either locally or via a remote PC. In order to ensure quality tobacco the controller holds kiln conditions steady when yellowing conditions are reached until the operator decides that yellowing is complete and the kiln should start drying. Once drying begins the controller again advances automatically to a predetermined end temperature. REMOE CONROL 5 DCS-3000 systems can be upgraded to be monitored and controlled remotely over a telephone line when the available software and hardware module are added. Software allows a farmer to see an overview of up to 253 kilns in one yard. Kilns requiring action are highlighted to draw the operator s attention. he farmer can select a particular kiln and see on his computer screen the status of that kiln. He can then change the status of that kiln. A new hardware interface unit, the DCS-IU, connects up to 253 kilns to one telephone line. CASING Before casing the first kiln of tobacco the operator enters the dry and wet bulb temperatures as well as the duration of casing he wants. he DCS-3000 will then automatically control the casing process. Again the operator can allow completely automatic operation of this step or view and change conditions at any time. 1 Supervisory control the controlled machine or process continues autonomously. It is observed from time to time by a human who, when deeming it necessary, intervenes to modify the control algorithm in some way. Wikipedia 2 Return Air or Delta temperature 3 Supply Air or Dry Bulb emperature 4 hese are default temperatures. hey be changed by the operator and will be remembered by the controller once changed. 5 See separate Computer Interface Manual DCS-3000 AutoCure Control System 2011 110707 page 3

2. OPERAION SAND-BY As long as power is applied to the DCS-3000 the dry bulb temperature of the kiln is indicated on the upper display. If the other displays are blank the unit is NO controlling the kiln and is said to be in stand-by mode. YELLOWING WE ELAPSED - delta WE delta ENER SEP1 SEP2 DMPR Press and hold the SEP1 button for about 5 seconds until the middle and lower displays light. While the unit operates the light in the SEP 1 button remains lit, the actual dry bulb temperature, the actual wet bulb temperature and the elapsed time displays will be on. he elapsed time counter is set to zero when SEP 1 is pressed. Use the set point keys to change the factory values if desired. ING WE ELAPSED - delta WE delta ENER SEP1 SEP2 DMPR When you are satisfied the yellowing process is complete press and hold the SEP 2 button until the SEP1 light goes off. he SEP2 light will turn on, the dry bulb temperature, wet bulb temperature and elapsed time displays will display. Use the set point keys to change the factory values if desired NOE: he DCS will only call for heat during YELLOWING and ING if all the following conditions are met: - the dry temperature is below or equal to the dry setpoint - the dry temperature is not more than the delta setpoint value above the delta temperature 6 - the dry temperature is not more than 10 degrees below the delta temperature 7 DAMPER OPERAION If the actual wet bulb temperature is below the set point the damper will remain closed. As soon as the wet bulb temperature exceeds its set point the damper will begin to open gradually until it is fully open when the actual temperature reaches the set point plus 2 1/2 degrees. his allows moisture to be exhausted from the kiln. 6 his allows the temperature to rise faster as the tobacco dries and allows more air to pass through while at the same time prevents tobacco near the floor from being overheated. It is also a safeguard to prevent a runaway kiln should one of the temperature sensors be mechanically damaged and report false readings. 7 Normally the top of the kiln, where the delta sensor is located, will be cooler than the floor where the dry bulb temperature sensor is located, and where heat is introduced. However, this condition allows the furnace to fire at startup on a hot day when the sun could have heated the air space above the tobacco bins. If the ceiling is even more than 10 degrees warmer than the floor the fan will continue to run until the circulating air has lowered the ceiling temperature. DCS-3000 AutoCure Control System 2011 110707 page 4

PING HE CURE WE ELAPSED - delta WE delta ENER SEP1 SEP2 DMPR At the end of the cure press SEP2 for about 5 seconds until the red light goes out. his will reset the clock, so that you are ready for the next cure. SE POIN KEYS here are set point keys, labelled, WE, delta to easily view and change any individual set point. While the program is running depress any set point key to display the set point value. o change the value, keep the key depressed and use the arrow keys to select the desired value. he program is now updated. Pressing the DAMPR key will display the damper percent opening. his can not be changed. he 10 degree alarm works as a high alarm. It does not monitor low temperatures. he DCS-3000 is delivered preprogrammed with the following values. YELLOWING SAGE dry bulb set point 100 F wet bulb set point 100 F delta set point 5 F ING SAGE dry bulb set point 155 F wet bulb set point 100 F delta set point 15 F Any changes to these values entered by the operator during one cure will be remembered by the instrument and used by it as the default values for the next cure. AUO DAMPER CONROL Auto damper control is active at all times. DCS-3000 AutoCure Control System 2011 110707 page 5

WHA HE KEYBOARD LIGHS MEAN If lit the dry or wet bulb temperature is 10 deg Fahrenheit or more above the set point. If lit the instrument is controlling SEP1 of a cure cycle. If lit the instrument is controlling the casing process. ELAPSED - delta SEP1 WE SEP2 delta WE DMPR If lit the instrument is controlling SEP2 of a cure cycle. If lit the instrument is calling for heat. Dry bulb temperature, Setpoint when pressed Wet bulb temperature Setpoint when WE pressed his display normally indicates elapsed hours. It indicates the delta setpoint when the delta button is depressed. It indicates delta actual when is pressed WHA HE BUONS DO Increase value displayed when, WE, RAE or DMPR buttons are pressed. Decrease value when, WE or delta buttons are pressed. Press SEP1 to start a cure. he DCS-3000 remembers the setpoints from the last cure. You can check the setpoints by pressing the, WE or delta keys. his step will control the cure up to the yellowing stage. 1. While in Standby Press 5 sec to start casing. 2. While in Casing Press 5 sec to stop casing. 3. While in SEP1 or SEP2 Press for temperature of delta sensor. WE ELAPSED - delta SEP1 SEP2 WE delta DMPR Press SEP2 to complete a cure. he DCS-3000 remembers the set points from the last cure. You can check the set points by pressing the keys on the right side. his step will control the cure from yellowing to completion. Press and hold here while pressing the arrow keys to change the temperature set point. Press and hold here while pressing the arrow keys to change the WE set point. Change the number of degrees the top and bottom of the kiln can be apart and still have the furnace fire Press and hold here to see the damper position displayed in % DCS-3000 AutoCure Control System 2011 110707 page 6

3. Casing 8 O BEGIN CASING From SANDY press and hold the button for 5 seconds until the light above this button remains on. his time delay is intentional to prevent casing beginning accidentally. Once a casing cycle is started it can be stopped by pressing the same button for 5 seconds. Again this time delay prevents casing from being accidentally stopped. SAR RAE WE DMPR While the unit operates, the light in the button remains lit, the upper display indicates the dry bulb, the middle display indicates the wet bulb and the lower display counts down the time remaining in the casing cycle. A dry bulb temperature of 122F and wet bulb temperature of 113F are automatically set by the instrument when the key is used the first time. hese values can be easily changed and the instrument will remember and use the most recent values when starting the next casing cycle. An elapsed time of 8 hours will be set by the DCS-3000 each time a casing cycle is started. his duration can be changed for the current cycle. he new value will not be stored for future cycles. When the CASING cycle is started:. the humidity relay is deactivated the 10 degree dry bulb window alarm is deactivated the fan will turn on the furnace relay will operate as required to reach the dry bulb setpoint if the actual dry bulb temperature is greater than the dry bulb setpoint. - the damper will open fully if the actual dry bulb temperature is less than the dry bulb setpoint. - the damper will close fully When the actual dry bulb temperature reaches its setpoint the damper will close fully the 10 degree dry bulb window alarm is activated the humidification relay will activate to maintain a wet bulb of 113F or the value specified by the operator by closing the normally open humidity relay when the wet bulb temperature drops below its setpoint. the gas valve will be controlled to maintain the dry bulb setpoint. the dry and wet bulb temperatures will be held at their setpoints for 8 hours or for as long as specified by the operator. When the timer counts down to 0 the damper will stay closed the fan will shut off the burner, humidity and 10 degree alarm relays will be de-activated the timer will continue to count down to 1.0 hours or until the button is held down for 5 seconds 8 this feature requires multi-function board DCS-3000 AutoCure Control System 2011 110707 page 7

O CHANGE CASING BULB EMPERAURE Hold the button down and at the same time press an arrow key until the desired new temperature is displayed. SAR RAE WE DMPR O CHANGE CASING WE BULB EMPERAURE Hold the WE button down and at the same time press an arrow key until the desired new temperature is displayed. ENER WE WE ELAPSED - delta delta SEP1 SEP2 DMPR O CHANGE CASING DURAION Hold the HOUR button down and at the same time press an arrow key until the desired new time is displayed. SAR RAE WE DMPR O A CASING CYCLE Hold the button for 5 seconds until the light in this button turns off. SAR RAE WE DMPR NOE 1: he DCS-3000 remembers the wet and dry bulb casing setpoints from run to run and uses the last values as the default. he casing duration can be changed for a run, but will reset to 8 hours for the next run. NOE 2: Once the dry bulb set point is reached the casing humidity relay will call for humidity when the actual wet bulb drops below set point. his will only have an effect if a water supply and the casing wand are connected. DCS-3000 AutoCure Control System 2011 110707 page 8

4. SE-UP (Changing the way the instrument works) he DCS-3000 is normally delivered preprogrammed and you will not need to use this section. If you want to change how the DCS-3000 operates these instructions tell you how to: Specify how many seconds to wait before starting the fan motor after a power failure 9 Specify the beginning of range temperature you can set in run mode Set an identification number for the instrument if using the communications features Set a correction to the pulsing rate Apply temperature correction to the RD temperature sensors Press and hold the UP arrow and keys for 10 seconds SAR RAE WE DMPR Software identification: After 10 seconds has elapsed and as long as you continue to hold the two keys the top display will read 308, the middle display will read r30 and the bottom display will read dt. his information is helpful to our technicians. Display check: Once you release the keys all numeric and LED displays will cycle continuously. his is used to verify all display segments are operating properly. Once you are happy all display segments are operational Press the key in the lower left corner SAR RAE WE DMPR Do this to move from step to step in the set-up process 9 this feature requires multi-function board DCS-3000 AutoCure Control System 2011 110707 page 9

Choose fan motor startup time delay: 123 CHOOSE DESIRED VALUE SAR RAE SAR RAE WE DMPR WE DMPR SE DESIRED VALUE o prevent circuit over loads when starting several kilns on the same power line after a power failure a time delay can be programmed to stagger the starts of individual kilns. he top display shows FAn, the middle display shows dly and the lower flashes the number of seconds the fan start up will be delayed. Choose the desired value with the arrow keys. Press the lower left unmarked key to set this value. his delay only applies to start after a power failure. On manual start the fan will start immediately. If you do not have the multi-function board set this value to zero since the instrument will prevent the furnace from firing until the set time has elapsed. Choose start temperature of operating range: 123 CHOOSE DESIRED VALUE SAR RAE SAR RAE WE DMPR WE DMPR SE DESIRED VALUE he top display shows Str and the middle display flashes a number from 32 to 112. Choose the desired value with the arrow keys. Press the lower left unmarked key to set this value. he operating range will always be 100 Fahrenheit degrees. It will normally be from 70 to 170. Choose instrument ID: 123 CHOOSE DESIRED VALUE SAR RAE SAR RAE WE DMPR WE DMPR SE DESIRED VALUE If several DCS-3000 s are connected to a computer you will need to uniquely identify each DCS-3000. In SEUP mode a 3 digit identification number can be assigned to each DCS-3000. he top display will read 1d, meaning identification. Choose the desired value with the arrow keys. Press the lower left unmarked key to set this value between 1 and 253. DCS-3000 AutoCure Control System 2011 110707 page 10

Changing the Aqua-Stat pulse rate 123 CHOOSE DESIRED VALUE SAR RAE SAR RAE WE DMPR WE DMPR SE DESIRED VALUE It is no longer necessary to manually adjust a knob on the front of the Aqua-Stat. he Aqua-Stat pulse rate is controlled by the DCS-3000 and automatically pulses faster as the temperature increases in the kiln. However, if the default value of 100 is either too slow and the wet bulb dries out or is too fast and the water reservoir empties too quickly the rate can be changed here. he default set at the factory is 100%. You can adjust this value in 1% increments down to 50% to decrease the time between pulses. his will increase the amount of water going to the wet bulb if it was drying out too quickly. You can also adjust this value in 1% increments up to 200% which will increase the time between pulses and use water less quickly. he top display will read AqA for Aqua-Stat. he bottom display will read a value from 50 to 200. Press either arrow key to choose the value you want. When the desired value is displayed press the lower left key to set the value. Apply temperature correction: SAR RAE WE DMPR he displayed temperature of each of the three RD sensors can be offset 10 here by up to plus or minus five degrees Fahrenheit. Hold the button to the right of the display to be offset and use the arrow keys to apply a correction. he DCS-3000 will not display temperatures above 185, so boiling water can not be used. Instead, immerse sensors in a bucket of ambient temperature water along with an accurate thermometer if you wish to verify the temperature accuracy or apply a correction. 10 emperature correction should rarely be necessary as this system uses platinum RD sensors. hese sensors are widely used in industrial applications where long term accuracy and stability are critical. Rare failures are normally the result of mechanical damage requiring sensor replacement. DCS-3000 AutoCure Control System 2011 110707 page 11

5. DEFAUL VALUES he standard unit will be delivered preprogrammed and ready for operation with the following variables preset. emperature displays will be in Fahrenheit he temperature control switching differential will be set to 0.7 degrees he beginning of range set point, SPL, will be set to 70 he motor start time delay will be set to 10 seconds he instrument ID will be set to 000 he delta SEP1 dry bulb will be set to 100F he delta SEP1 wet bulb will be set to 100F he delta SEP1 differential will be set to 5F he delta SEP2 dry bulb will be set to 155F he delta SEP2 wet bulb will be set to 100F he delta SEP2 differential will be set to 15F he casing dry bulb temperature will be set to 122F he casing wet bulb temperature will be set to 113F he casing time will be set to 8 hours 6. ALARMS he High alarm will be active while the unit is in SEP1 or SEP2. 1. If either the wet or dry bulb is 10 degrees above its corresponding set point an alarm relay will be closed. his relay can be wired into an external annunciator. 2. An LED to the left of the dry bulb display indicates a high temperature alarm. DCS-3000 AutoCure Control System 2011 110707 page 12

7. ROUBLE SHOOING he unit will not power up if: he air pressure switch does not detect the fan running. An on/off toggle switch has been installed and is in the OFF position he unit will not call for heat if: he set point alarm temperature is 10 degrees F or more above the dry bulb set point. he high alarm temperature is above its set point which can be set to 150,200 or 250F. In this case the relay will latch open and can be reset by pushing the button on the multi-function board after the temperature has dropped. 8. CONNECIONS 1!!! 8 16 9 he above view is from the back of the DCS-3000-A controller 1. 24 VAC1 2. Ground 3. 5V for Comms 4. Gas valve (N.O.) 5. Gas valve common 6. Gas valve (N.C.) 7. Alarm relay common 8. Damper output (2-10 VDC) 9. emperature Set point logic signal to multi-function board 10. Alarm relay (N.C.) 11. Alarm relay (N.O.) 12. Humidification control logic signal to multi-function board 13. Comms Receive 14. Comms ransmit 15 Fan control logic signal to multi-function board 16. 24 VAC2 DCS-3000 AutoCure Control System 2011 110707 page 13

9. COMPAIBILIY WIH PREVIOUS VERSIONS DCS-3000 front boards and multi function boards manufactured recently can be upgraded to AutoCure units. You can see if a DCS-3000 controller can be upgraded by checking its Software Identification. o do this see section 4. If the first digit on the top display is a 2 or 3 the instrument can be upgraded. Most commonly the top display will read 201 or 308 on versions that can be upgraded. 10. AQUA-SA PULSING RAES he DCS-3000 increases the Aqua-stat pulsing rate as the actual dry bulb temperature increases to ensure accurate wet bulb temperatures at higher temperatures. DCS-3000 AutoCure Control System 2011 110707 page 14