CalMag Filter Installation Instructions

Similar documents
CalMag Heating Pack Installation Instructions

DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

Installation and servicing instructions

Greenstar System Filter

PRODUCT GUIDE. High performance heating system filter Improves energy efficiency Captures magnetic and nonmagnetic.

PERFORMANCE SHOWER PRODUCTS

Eliminator TotalGuard Installation Manual

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

HEAVY DUTY BRASS SHOWER PUMPS

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

Winchester Heated Towel Rail. Fitting Instructions

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Male elbow, copper x BSP taper male thread

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Union coupling. copper x copper. Cone joint to BS 1010.

Rycroft Supapac Plate Heat Exchangers

Installation Instructions Flute Tap Range

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Aquila Single Lever Vessel Faucet

Ocellaris Instruction version: 30/06/2014. Inspiring Excellence in Fish Care! Coldwater. Tropical.

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Boiler protection kit guide

Seda 8 Widespread 2-Handle Faucet

ASSEMBLY & OPERATING INSTRUCTIONS

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Coda Single Lever Basin Faucet

Alkaline RO System INSTALLATION MANUAL

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

PLATE DISPENSER MODEL NUMBERS MPN10000 MPN10500 MPN20000 MPN20500

Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET

Infra Red Thermostatic Wall Mixer

General System Layout Sketch

Installation & Operating Instructions

ERGOMAX 7 INSTALLATION

Cirrus 8 Widespread Basin Faucet

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

Dove Eco thermostatic bar mixer shower

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

PROPANE GAS HEATER MODEL NO: GRH35 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC01/14

BASIN MIXERS INSTALLATION & AFTERCARE INSTRUCTIONS

Solinder Single Lever Basin Faucet

CPC-150-ANA. 150 litres, 535mm x 1300mm high. Pandora Heat Bank. 100kW Plate Heat Exchanger with 22mm Thermostatic Mixing Valve.

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Dovre 250 Cast Iron Gas Stove

OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE

POWER SHOWERS Models 4500M 5002M 4500T 5002T

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Oltis thermostatic bar mixer

WC2 & WC3 Installation & Maintenance Instructions

Intatherm Safe Touch Basin Tap IT1008CP

User and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396

Optimax Refrigerated Retail Merchandisers

Optimax Refrigerated Retail Merchandisers

SEALED THERMAL STORE

Single Lever Pull Out Kitchen Faucet

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

STEAM WALLPAPER STRIPPER MODEL HTW5

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Coda 8 Widespread Basin Faucet

Food Waste Disposer Instruction Manual

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

TFM, TFC & TFN Filters. Installation and Operating Instructions

Beautifully Traditional

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

5700-E Sediment Filter Installation & Start-Up Guide

For commercial & industrial systems. Large volume dirt collection capacity

BMW E36 Thermostat Removal And Coolant Flush

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

Installation and Commissioning Manual

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

TITAN FLOW CONTROL, INC.

SLIM-LINE RC FAN CONVECTOR.

HEAVY DUTY RANGE BAIN MARIES & HOTCUPBOARDS (ELECTRIC)

Installation and Servicing Instructions

METRO BASIN MONO MIXER CHR

ADVANCE ECB ELECTRIC COMBINATION BOILER

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

IS09 ECN2087. EB3, EB4 & EB6 Automatic Fill Water Boilers INSTALLATION, USER & SERVICING INSTRUCTIONS

Installation and Operating Instructions for Microlene Underbench System

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

ELECTRIC ASH CAN Model: CVACASH500 Part No:

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Infra Red Basin Tap IR120CP.1 & IR121CP.1

Oil burners fuel unit with solenoid valve

ELECTRONIC WATER CONDITIONERS USER GUIDE IMPORTANT READ THESE INSTRUCTIONS BEFORE FITTING

100 Series Maxi Internal Filters

AllClear G2 Series Pressurized Filters Product Manual

PERSONAL CUEING DEVICE MODEL NO. BDAAU100 INSTRUCTION MANUAL.

Transcription:

Calming troubled waters CalMag Filter Installation Instructions Please note: This filter is unique and does not have or need a messy top mounted air bleed valve. Air is channelled via a snorkel arrangement to the bottom drain valve where the air and water mixture can be conveniently and cleanly collected in a bucket or similar receptacle.

CalMag Filter Installation Instructions CALMAG FILTER 22mm This CalMag Filter has been designed and manufactured in Great Britain under a quality management system, registered to ISO 9001. Key features of this design are the bottom mounted bleed point, the ease with which the canister can be fully emptied and that the canister can also double as a dosing point for liquid water treatment chemicals. The body and lid are manufactured from Zytel nylon resin and can withstand a maximum pressure of 10 Bar at 82 C. Why fit a CalMag filter? Radiator panels provide the largest surface area of a central heating system where they act as heat emitters. They are usually made of mild steel, which is highly reactive to corrosion. Even with a quality corrosion inhibitor installed, low levels of corrosion can occur. In the absence of air this is usually black magnetite, which is magnetic in nature and which can therefore be captured with a magnet. Although magnetite is seven times heavier than water and quite happy to sit in the bottom of the radiator from whence it came, some particles are dispersed around the system by the flow. If a magnetic filter does not collect these particles, they will surely end up trapped in the next device with electro-magnetic properties; the circulator pump where they will cause premature wear. The magnetic filter can also double as a sampling point to analyse the system water, or become the treatment point for liquid chemical additives. The table below shows some water conditions and suggested remedial action that can be determined from visual inspection of the contents of the filter canister:- Water Condition Clear water, no magnetite Clear water, magnetite build up Black water, magnetite build up Orange water, no magnetite Orange water, magnetite build up Suggested Remedial Action System appears to be corrosion free inspect annually. Top up inhibitor every one to three years System is corroding. Clean filter, add inhibitor, inspect every one to three months System is corroding badly. Clean the system consider Power Flushing, then add inhibitor on final fill System is corroding due to ingress of air investigate mechanical fault then clean the system then add inhibitor on final fill System is corroding due to ingress of air and likely absence of inhibitor. Investigate mechanical fault. Clean the system consider Power Flushing, then add inhibitor on final fill Zytel is a registered trademark of DuPont.

Please retain these instructions for future use. Do s: Install the filter upright to enable it to be fully evacuated of air during commissioning. Pipe runs can be vertical, horizontal or any angle in between. The inlet and outlet can also be swapped to suit. Where the filter is fitted to the metallic building structure, Earth bonding continuity is required around it. All bonding connections must be accessible and labelled Safety Electrical Connection Do Not Remove. Service the filter annually (at boiler inspection) to remove any collected debris. Use the filter in conjunction with a scale and corrosion inhibitor. The inlet/outlet valves have PTFE valve seats, which can be initially stiff. Operate with the hex end of the service spanner to loosen for hand operation: When using the key/cap to bleed air from the system make sure you have a bucket handy to catch the spill. Screw key/cap onto drain valve as a drip cover. Don ts: Magnets may affect or interfere with sensitive mechanical and electronic instruments such as heart pacemakers, computers / magnetic media and watches. Always keep magnets at least 300mm (1 foot) away from such equipment. NEVER close the INLET or OUTLET isolation valves, OR UNDO the lid when the pump is running! Don t get scalded! Allow the system to cool before operating the device. Don t fit the device too close to the boiler allow at least 300mm gap and sufficient space to service the unit. Don t tighten the lid with the service spanner over tightening could damage the unit. Don t remove the laminated label from the body of the filter. This carries the unit s unique serial number and removal will invalidate the warranty. Don t attempt to tighten (or loosen) the drain valve s union with the canister as this has been fastened into position with Thread Lock to form a permanent watertight seal. Consequently this is NOT a user serviceable connection.

CalMag Filter Installation Instructions Spare Parts: For warranty and spare parts, in the first instance, please call our Technical Department on 01535 210320.

Installation Instructions Only a competent person such as a qualified heating engineer should install the device. 1. Locate a suitable site for the filter to allow access and servicing. We recommend that you fit it on the return. Do not fit it between the boiler and the overflow on open vented systems. 2. Release heating system pressure and drain the pipe-run where the filter is to be located. (It may be necessary to drain the whole system). 3. The filter has been designed to facilitate various inlet and outlet configurations. Most configurations will require Elbows. For soldering we recommend 2 x Solder Ring Elbow 22mm or for compression we recommend 2 x Compression Elbow 22mm and the fitting instructions (which follow) are based around dimensions of these Elbows. For clarity the recommended solder and compression fittings require the same dimension of cut out. 4. Vertical pipe runs: measure and mark a 109mm section and remove the marked section with a rotary tube cutter. Create 64mm and 106mm lengths of 22mm copper pipe to attach between the respective elbow and compression fitting on the inlet/outlet. [Tip: re-use the cut-out section] The inlet and outlet isolation valves should face the wall for a compact installation. The diagram shows how to mount the filter on the left of the pipe-run (looking from the wall). To mount the filter on the right of a pipe run simply swivel the isolation valves through 180 and swap the 106mm length to the upper position and the 64mm length to the lower position.

CalMag Filter Installation Instructions Horizontal pipe runs: measure and mark a 73mm section and remove the marked section with a rotary tube cutter. Create 64mm and 134mm lengths of 22mm copper pipe to attach between the respective elbow and compression fitting on the inlet/outlet. [Tip: re-use the cut-out section] 5. Lubricate the olives within the isolation valves with jointing compound, and tighten the compression fittings. 6. Loosely secure the canister to the valves ensuring the canister is upright and square. Don t fit the washers at this point as you are pre-assembling the filter to assess it for fit. Providing everything lines up proceed to the next step, otherwise make any necessary adjustments. 7. Loosen off the valve flange nuts and insert the washers. Thoroughly tighten the flange nuts, taking care not to over tighten. DO NOT leave the washers out. Tighten the lid retaining-ring only by hand. 8. Refill the heating system, ensuring the inlet and outlet valves are both in the OPEN position, with the drain valve in the CLOSED position. 9. Start the heating system. Have a bucket ready to collect spillage and open the drain valve to purge air from the filter. Close the drain valve once water begins to flow. Bleed the filter again after the system has come up to temperature. Take care when doing so as the water expelled will be hot. Observe the unit, checking that there are no leaks. 10. The unit has now been successfully commissioned. If fitted correctly it will be silent in operation. We suggest its serviced annually to remove any particulate matter that it has collected. This could be done at the same time the boiler is serviced.

Annual Servicing Requirement: 1. Before commencing any service work, turn off the boiler and isolate the electrical supply. Wait for the temperature to cool before undertaking any work to avoid scalding. Turn both isolating valves to the OFF position. Have a bucket ready to collect spillage and OPEN the drain valve to release internal pressure. CLOSE the drain valve again to free your hand. 2. Open the lid by turning the retaining-ring anticlockwise using the service spanner. Remove the inner lid, by lifting upwards to withdraw the magnet. 3. Withdraw the snorkel. Some debris may stick to the non-magnetic snorkel but the remaining debris will fall to the bottom of the canister. 4. Have a bucket ready to collect spillage and reopen the drain valve to allow the debris to escape. Rinse out the canister with fresh water and clean the snorkel, lid, O-ring, magnet and mesh before reassembling. 5. Tighten the lid retaining-ring only by hand. Ensure the inlet and outlet valves are both in the OPEN position, with the drain valve in the CLOSED position. Start the heating system. 6. Have a bucket ready to collect spillage and open the drain valve to purge air from the filter. Close the valve once water begins to flow. Bleed the filter again after the system has come up to temperature. Take care when doing so as the water expelled will be hot. Observe the unit, checking that there are no leaks. Chemical Dosing: At step 4 in servicing, place the snorkel in position and carefully pour a bottle of water treatment corrosion and scale inhibitor (sufficient capacity is available to hold 500ml) into the canister, down the outer edge of the snorkel do not tip it down the centre of the snorkel, as this is the drain exit! For best results temporarily cover the hole in the snorkel with the bottle lid. Continue with step 5 in servicing. Allow the system to circulate for 5 minutes to disperse the chemical treatment. Continue with step 6 in servicing to complete the operation. Warranty: The 5 year limited warranty is subject to the following terms and conditions: I. That the filter has been correctly installed and serviced in accordance with the instructions herein provided. The warranty does not cover damage or defects caused as a result of im proper installation or servicing. II. That the filter has not been tampered with or misused. III. That the filter has not been modified in any way. IV. That the filter s label and unique serial number has not been removed. V. That the filter is returned at the purchaser s own cost together with proof of purchase in the form of an original receipt or invoice (which will be returned). VI. The sole and exclusive remedy under this warranty is for the repair or replacement of the filter and no other remedy including but not limited to incidental or consequential damage or loss, irrespective of nature shall be available. VII. This warranty will not cover any associated installation costs incurred as a result of the filter being defective. VIII.Our decision on matters relating to warranty claims shall be final. This warranty does not affect your statutory rights.

Phone: 01535 210320 Fax: 01535 210321 Email: sales@calmagltd.com Web: www.calmagltd.com Calmag Ltd Riverview Buildings, Bradford Road, Riddlesden, Keighley, West Yorkshire, BD20 5JH