Model AI. Intrinsically Safe Pressure Gauge DESCRIPTION FEATURES

Similar documents
Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Airflow Sensors Line Guide

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Airflow Sensors Line Guide

TruStability Board Mount Pressure Sensors

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

MICRO SWITCH NT Series

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Force Sensors Line Guide

MICRO SWITCH NT Series

Intrinsically Safe Transmitters, Option Code 2n

HIH-4602-L Series Humidity Sensors

HIH-4602 A & C Series.

HIH-5030/5031 Series Low Voltage Humidity Sensors

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

V-Basic Standard V15 Series

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

FSS-SMT Series. Low Profile Force Sensor


HIH-4000 Series Humidity Sensors

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Potential Applications

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Guide to Hazardous Location Approvals:

MICRO SWITCH BAF/DTF Series

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

MICRO SWITCH E6/V6 Series

Installation Instructions for the

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

High Temperature Industrial VRS Magnetic Speed Sensors

MICRO SWITCH GSX Series

Micropower Omnipolar Digital Hall-Effect Sensor ICs

Linear Current Sensors

Wireless Panel-Mount Monitor

MICRO SWITCH GLL Series

General Purpose Industrial VRS Magnetic Speed Sensors

Sensors in Ventilators

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HIH-4010/4020/4021 Series Humidity Sensors

HOA6480 Series Barcode Sensor Infrared Products

WARNING MISUSE OF DOCUMENTATION

Selecting Honeywell Board Mount Pressure Sensors

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

HFX Fiber Optic Component 50 Mbps, 650 nm LED

FEATURES AND BENEFITS

Fiber Optics and Liquid Level Sensors Line Guide

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

MICRO SWITCH V15W Series Watertight Miniature Switches

Heavy Duty Pressure Transducers Line Guide

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HIH-4030/31 Series Humidity Sensors

Installation Instructions for the 600 Series Optical Encoders

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Sensors and Switches in Commercial Traction Elevators

MEAS CAL ALARM WASH CONF APT4000 TC

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

MICRO SWITCH Basic Switches Line Guide

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MICRO SWITCH BX/BX2 Series

Configurable Pressure Transducer Model FP Issue 1. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

MICRO SWITCH. Pushbutton Switches Line Guide FEATURES MICRO SWITCH. PUSHBUTTON SWITCHES PB Series. Features: Compact size Up to four

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer

Heavy Duty Pressure Transducers

Interactive Catalog Replaces Catalog Pages

Toroidal Conductivity Transmitters Series APT4000 Specifications

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Honeywell Pressure Switches Line Guide

DP86 Constant Voltage with Fitting

LCZ Series Hall-effect Zero Speed Sensors

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

Transcription:

Model AI Intrinsically Safe Pressure Gauge DESCRIPTION As an in-process gauge or portable calibrator, the hand-held Model AI delivers long-lasting performance with enhanced accuracy. Accuracy of 0.05 % coupled with an enhanced resolution, 4½-digit display makes this unit an excellent transfer standard for calibrating pressure measuring equipment. The AI is rugged and features high/low pressure capture with a field-adjustable update rate from three-to-ten times per second. These units are manufactured from stainless steel and use sensor technology which has no moving parts, requires little recalibration and has excellent overpressure tolerance. NEMA 4 construction provides EMI and RFI protection. Units of measure are field-selectable, and the unit is offered with gage, absolute, vacuum, or compound reference. The Model AIW is powered by one or two common 9 V alkaline batteries. The Model AIV is powered by an 11 Vdc to 32 Vdc power supply. The AI Digital Gauges have the following complete Factory Mutual Approved Classifications: Class I: Gases and vapor Class II: Combustible dust Class III: Fibers Intrinsically safe systems limit the thermal and electrical energy to the hazardous area to help prevent ignition. Division 1: present or likely to be present in normal operation Division 2: not present in normal operation Group A: Acetylene Group B: Hydrogen Group C: Acetaldehyde, Ethylene, Methyl Ether Group D: Acetone, Gasoline, Methanol, Propane Group E: Metal dust Group F: Carbon dust Group G: Grain dust FEATURES High accuracy: 0.05 % full scale Factory Mutual approved Ranges to 10000 psi - gage, absolute, vacuum, or compound construction 4½ digit display with 0.5 in height On/off switch Optional handles Optional carrying case and panel mounting ring 9 V battery power High/low capture and store

Model AI PERFORMANCE SPECIFICATIONS ADDITIONAL SPECIFICATIONS Accuracy 0.05 % of full scale BSFL Pressure range, 0 psi to: 15, 50, 100, 200, 500, 750, 1000, 1500, 2000, 5000, 7500, 10000 psi High and low capture Standard Pressure range (psi) 0 psi to 15 psi = 15 0 psi to 50 psi = 50 Maximum safe over pressure (psi) 1 75 0.005 250 0.01 Incremental display steps Update speed Adjustable from 3 to 10 per sec 0 psi to 100 psi = 100 500 0.02 ENVIRONMENTAL SPECIFICATIONS Temperature, operating (standard) Temperature, operating (optional) -1 C to 71 C [30 F to 160 F] -18 C to 82 C [0 F to 180 F] 0 psi to 200 psi = 200 0 psi to 500 psi = 500 0 psi to 750 psi = 750 0 psi to 1000 psi = 1K 0 psi to 1500 psi = 1.5K 1000 0.05 1500 0.1 1500 0.2 2000 0.2 3000 0.5 ELECTRICAL SPECIFICATIONS Rating Power, Model AIW Power, Model AIV NEMA 4 (also provides temperature range of -18 C to 82 C [0 F to 180 F]) One or two 9 V alkaline batteries (included) (3 ft cable included) 0 psi to 2000 psi = 2K 0 psi to 5000 psi = 5K 0 psi to 7500 psi = 7.5K 0 psi to 10000 psi = 10K 4000 0.5 7500 1 12000 2 15000 2 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage MECHANICAL SPECIFICATIONS Diameter 93,98 mm [3.7 Mounting dimensions and characteristics Display Pressure port Wetted parts Case material Low battery indication Face membrane Calibration data 4 LCD digits - 12,7 mm [0.5 high 9/16-18 UNF-2B - female straight thread with SAE spec J514 o-ring boss Standard Tactile feedback raised buttons Stored on memory chip For reference only 2 Honeywell Sensing and Control

Model AI Order Guide * = Example SERIES AI POWER W V Notes = Battery powered (9 V alkaline)* = 11 Vdc to 32 Vdc (3 ft. cable) PRESSURE RANGE (PSI) 15 = 0-15 50 = 0-50 100 = 0-100 200 = 0-200* 500 = 0-500 750 = 0-750 1K = 0-1000 1.5K= 0-1500 AI W 200 G REFERENCE G = Gage (std) reads zero at atmosphere * A = Absolute (opt) reads zero at vacuum (15 psi or higher) V = Vacuum (opt) scaled in In Hg (15 psi or lower) C = Compound (opt) reads both positive & negative (vacuum) pressure ELECTRICAL CONNECTION 2K = 0-2000 5K = 0-5000 7.5K= 0-7500 10K = 0-10000 Z = No electrical connection (Model AIW - 9 V battery)* C=3 foot cable (Model AIV) Call factory for availability of other electrical connections and cable lengths. FIELD SELECTABLE STANDARD UNITS OF MEASURE Each gauge has the following scaling built in for field selection: Bar = Bar Ft H20 = Feet of water mbar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mm of mercury Consult factory for other units of measure not listed 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/Vac at 1/2 A. Z Intrinsically Safe Pressure Gauge Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008688-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model AK Digital Pressure Test Gauge DESCRIPTION The hand-held Model AK is an in-progress gauge or portable calibrator and delivers long-lasting, enhanced accuracy performance. Accuracy of 0.05 % coupled with an enhanced resolution, 4½-digit display makes this unit an excellent transfer standard for calibrating pressure measuring equipment. The AK is rugged and features high/low pressure capture with a field-adjustable update rate from three to 10 times per second. These units are manufactured from stainless steel and use sensor technology which has no moving parts, requires little recalibration and has excellent overpressure tolerance. Optional NEMA 4 rating extends the operating temperature to -18 C to 82 C [0 F to 180 F]. Units of measure are field-selectable and the unit is offered with gage, absolute, vacuum, or compound reference. * with optional NEMA 4 rating FEATURES High accuracy: 0.05 % full scale 0 F to 180 F operating temperature* Enhanced resolution construction Field-selectable units of measure 4½ digit display with 0.5 in height Customer recalibration On/Off switch CE compliant (certain models, consult factory) NEMA 4 rating (optional) Optional carrying case and panel mounting ring Optional pressure ports NIST traceable (optional) 9 V battery power High/low capture and store

Model AK PERFORMANCE SPECIFICATIONS Accuracy 0.05 % of full scale BFSL Pressure ranges 0 psi to 15, 50, 100, 200, 500, 750, 1000, 1500, 2000, 5000, 7500, 10000 psi ENVIRONMENTAL SPECIFICATIONS Temperature, operating (standard) Temperature, operating (optional) ELECTRICAL SPECIFICATIONS Rating Display Power, Model AKW Power, Model AKT Power, Model AKV -1 C to 71 C [30 F to 160 F] -18 C to 82 C [0 F to 180 F] (NEMA 4 option required) MECHANICAL SPECIFICATIONS Physical diameter Pressure port Wetted parts Case material Low battery indication High and low capture Update speed Face membrane Calibration data NEMA 2 (NEMA 4 optional, except AKT) 4½ LCD digits - 12,7 mm [0.5 high One or two 9 V alkaline batteries (included) 110 Vac adapter @ 60 Hz (included) (3 ft cable included) 93,98 mm [3.7 9/16-18 UNF-2B, female straight thread with SAE spec J514 0-ring boss Standard Standard Adjustable from 3 to 10 per second Tactile feedback raised memory chips Stored on memory chip ADDITIONAL SPECIFICATIONS ORDER CODE * = Example SERIES AK* POWER W T V Pressure range (psi) ORDER CODES = Battery Powered (9 V alkaline)* = 110 Vac adapter (included) = 11 Vdc to 32 Vdc (3 ft. cable) PRESSURE RANGE (PSI) 15 = 0-15 50 = 0-50 100 = 0-100 200 = 0-200* 500 = 0-500 750 = 0-750 1K = 0-1000 1.5K= 0-1500 AK W 200 G 2K = 0-2000 5K = 0-5000 7.5K= 0-7500 10K = 0-10000 REFERENCE G = Gage (std) reads zero at atmosphere * A = Absolute (opt) reads zero at vacuum (15 psi or higher) V = Vacuum (opt) scaled in In Hg (15 psi or lower) C = Compound (opt) reads both positive & negative (vacuum) pressure ELECTRICAL CONNECTION Maximum safe over pressure (psi) 1 0 psi to 15 psi = 15 75 0.005 0 psi to 50 psi = 50 250 0.01 0 psi to 100 psi = 100 500 0.02 0 psi to 200 psi = 200 1000 0.05 0 psi to 500 psi = 500 1500 0.1 0 psi to 750 psi = 750 1500 0.2 0 psi to 1000 psi = 1K 2000 0.2 0 psi to 1500 psi = 1.5K 3000 0.5 0 psi to 2000 psi = 2K 4000 0.5 0 psi to 5000 psi = 5K 7500 1 0 psi to 7500 psi = 7.5K 12000 2 0 psi to 10000 psi = 10K 15000 2 Z = No electrical connection (Model AKW - 9 V battery)* C=3 foot cable (Model AKV) T = ac adapter (Model AKT) Call factory for availability of other electrical connections & cable lengths. OPTIONAL 4 = NEMA 4 (Not available on AKT) NEMA 4 option also provides temperature range of 0-180 F Incremental display steps 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Z 4 FIELD SELECTABLE STANDARD UNITS OF MEASURE Each gauge has the following scaling built in for field selection: Bar = Bar mbar = Millibar kpa = Kilopascals MPa = Megapascals Ft H20 = Feet of water In H20 = Inches of water In Hg = Inches of mercury mmhg = mm of mercury Consult factory for other units of measure not listed 2 Honeywell Sensing and Control

Model AK Digital Pressure Test Gauge Mounting dimensions and characteristics Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For reference only Notes 1. Ure faci bla feuipit nostin vullam zzril 2. Ure faci bla feuipit nostin vullam zzril dolesto consent nis del ipsuscilis nismodiamcor sustinit am eugait velestinit ut nibh elisim eugait nim iril ut del duisi. 3. Ure faci bla feuipit nostin vullam zzril dolesto consent nis del4. Ure faci bla feuipit nostin vullam zzril dolesto consent nis del5. Ure faci bla feuipit nostin vullam zzril dolesto consent nis del 6. Ure faci bla feuipit nostin vullam zzril dolesto consent nis del ipsuscilis nismodiamcor sustinit am eugait velestinit ut nibh elisim eugait nim iril ut del duisi. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008689-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JA High Accuracy Digital Pressure Gauge DESCRIPTION The Series JA digital pressure test gauge with 0.1 % full scale accuracy uses transducer technology and a stainless steel diaphragm for high overpressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JA has no moving parts and thus, may provide a long life with fewer re-calibrations. The stainless steel NEMA construction also provides EMI and RFI protection. The JA provides high resolution with an easy to read digital display. There are no operator errors due to interpolation of hash marks or parallax errors. The Model JAB provides a 4 ma to 20 ma, two-wire output. The Model JAE provides a 0 Vdc to 5 Vdc output. The Model JAR has two programmable limits and relays with no analog output. The Model JAX provides a 0 Vdc to 5 Vdc output with two programmable limits and relays for process control or alarm indication. The Model JAW is powered by one or two common 9 V alkaline batteries. The Model JAT is powered by a 110 Vac adapter. The Model JAV is powered by an 11 Vdc to 32 Vdc power supply. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. FEATURES 4 ma to 20 ma (two-wire) and 0 Vdc to 5 Vdc analog outputs Two programmable limits and relays (optional) High accuracy - 0.1 % full scale High and low detection - Microprocessor based Ranges to 10000 psi, gage or absolute 4½ digit display with 0.5 in height Customer recalibration Zero offset/tare On/off switch disable feature Two programmable limits and relays (optional) NEMA 4 rating (optional) Optional carrying case and panel mounting ring NIST traceable (optional)

Model JA PERFORMANCE SPECIFICATIONS Linearity and hysteresis 0.1 % full scale (better than test gauge accuracy) Pressure range 0 psi to 10, 20, 50, 100, 200, 500, 1000, 2000, 5000 and 10000 psi High and low capture Update speed Zero and span signal adjustment Standard 3 times per sec Standard: Models JAB, JAE, JAX ADDITIONAL SPECIFICATIONS Pressure range (psi) Maximum safe over pressure (psi) 2 0 psi to 10 psi = 10 50 0.01 0 psi to 20 psi = 20 100 0.01 0 psi to 50 psi = 50 250 0.05 0 psi to 100 psi = 100 0 psi to 200 psi = 200 500 0.1 1000 0.1 Incremental display steps ENVIRONMENTAL SPECIFICATIONS Temperature, operating -1 C to 71 C [30 F to 160 F] ELECTRICAL SPECIFICATIONS Rating NEMA 2 (optional NEMA 4) 0 psi to 500 psi = 500 0 psi to 1000 psi = 1K 0 psi to 2000 psi = 2K 0 psi to 5000 psi = 5K 0 psi to 10000 psi = 10K 1500 0.5 2000 1 4000 1 7500 5 15000 5 Power, Model JAW Power, Model JAT Power, Model JAV Power, Model JAB Power, Model JAE Power, Model JAR Power, Model JAX Electrical connection One or two 9 V alkaline batteries (included) 110 Vac adapter @ 60 Hz (included) (3 ft cable included) 11 Vdc to 32 Vdc (depending on loop resistance) @ 20 ma 3 ft cable standard: Models JAB, JAE, JAR, JAX, JAV 2 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Mounting dimensions and characteristics MECHANICAL SPECIFICATIONS Diameter Display Pressure port 93,98 mm [3.7 4½ LCD digits - 12,7 mm [0.5 high 1/4-18 NPT male (200 psi and below) 1/4-18 UNF 2B female straight thread with SAE spec J514 o-ring boss (500 psi and above) Wetted parts Case material Face membrane Calibration data Low battery indication Limits and relays Tactile feedback raised buttons Stored on memory chip Standard: Model JAW Models JAR and JAX1 For reference only 2 Honeywell Sensing and Control

Model JA ORDER guide * = Example SERIES JA = High accuracy 0.1% full scale* MODEL DESIGNATION Models with Output Signal B = 4 ma to 20 ma (two-wire) E = 0 Vdc to 5 Vdc R = 2 programmable limits & relays X = 0 Vdc to 5 Vdc with two limits & relays Models with No Output Signal W = Battery powered (9 V alkaline) * T = 110 Vac adapter (included) V = 11 Vdc to 32 Vdc (3 ft. cable) PRESSURE RANGE (PSI) 0-10 =10 0-200 = 200 0-20 =20 0-500 = 500 0-50 =50 0-1000 = 1K* 0-100=100 0-2000 = 2000 JA W 1K G Z ( ) 0-5000 = 5K 0-10000= 10K REFERENCE G = Gage (std) reads zero at atmosphere* A = Absolute (opt) reads zero at vacuum(15 psi or higher) ELECTRICAL CONNECTION Z = No electrical connection (Model JAW - 9 volt battery)* C=3 foot cable T = ac adapter (Model JAT) B = Bendix (opt) PTIH-10-6P or equal (connector sold separately) Call factory for availability of other electrical connections and cable lengths. The following order code is used ONLY if you want this option. NEMA 4 CONSTRUCTION 4 = NEMA 4 (not available on Model JAT) FIELD SELECTABLE STANDARD UNITS OF MEASURE Bar = Bar Ft H20 = Feet of water MBar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mm of mercury Consult factory for other units of measure not listed This order code is used ONLY if you want NEMA 4 Rating. NOTES 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/ Vac at 1/2 A. High Accuracy Digital Pressure Gauge Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008690-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JD Differential Digital Pressure Gauge DESCRIPTION The hand-held Model JD wet/wet differential pressure gauge delivers long-lasting, enhanced accuracy performance. Accuracy of 0.2 % coupled with an enhanced resolution, 4½-digit display makes this unit an excellent transfer standard for calibrating pressure measuring equipment. The JD is rugged and features high/low pressure capture with an update rate of three times per second. These units are manufactured from stainless steel and use sensor technology which has no moving parts, requires little recalibration, and has excellent overpressure tolerance. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. FEATURES Ranges 1 psi to 10000 psi differential Field selectable units of measure 4 ma to 20 ma (two-wire) or 0 Vdc to 5 Vdc analog outputs (optional) Two programmable limits and relays (optional) High and low detection with microprocessor memory 4½ digit display with 0.5 in height Accuracy 0.2 % full scale Optional NEMA 4 rating NIST traceable CE compliant (certain models, consult factory) On/off switch with auto-off feature

Model JD PERFORMANCE SPECIFICATIONS Linearity and hysteresis 0.2 % full scale (better than test gage accuracy) Pressure range 0 psid to 1, 5, 5, 10, 15, 25, 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10000 psid High and low capture Update speed Zero and span signal adjustment Standard 3 times per sec ENVIRONMENTAL SPECIFICATIONS Temperature, operating Standard: Models JDB, JDE, JDX ELECTRICAL SPECIFICATIONS -1 C to 71 C [30 F to 160 F] Rating NEMA 2 (optional NEMA 4) Power, Model JDW Power, Model JDT Power, Model JDV Power, Model JDB Power, Model JDE Power, Model JDR Power, Model JDX Electrical connection MECHANICAL SPECIFICATIONS Diameter Display Pressure port Wetted surfaces O-ring material Housing Face membrane Calibration data Low battery indication Limits and relays One or two 9 V alkaline batteries (included) 110 Vac adapter @ 60 Hz (included) (3 ft cable included) 11 Vdc to 32 Vdc (depending on loop resistance) @ 20 ma 3 ft cable (standard) on Models: JDB, JDE, JDR, JDX, JDV 93,98 mm [3.7 4½ LCD digits - 12,7 mm [0.5 high 1/8-27 NPT female on rages to 750 psid; 1/4-18 NPT female on ranges 1000 psid and above 1 psid to 750 psid - Viton 1000 psid to 10000 psid - Teflon-coated stainless steel Tactile feedback raised buttons Stored on memory chip Standard on Model JDW Models JDR and JDX Accessories order codes Order code AD12 AD5 AD2 AD3 NISTCERTS Accessory * available Pressure adapter (Zinc plated steel) 1/8-27 NPTM by 1/4-18 NPTF* Pressure adapter (Zinc plated steel) 1/4-18 NPTM to 1/4-18 NPTM* Pressure adapter (Zinc plated steel) 1/4-18 NPTM to 7/16-20 UNF F* Pressure adapter (Zinc plated steel) 1/4-18 NPTM to 7/16-20 UNFM* NIST certification (in addition to NIST statement) Additional specifications Pressure range (psi) Maximum line pressure (psi) 1 Maximum safe over pressure (psi) 2 0 psi to 1 psi 1500 1500 0.001 0 psi to 2 psi 1500 1500 0.001 0 psi to 5 psi 1500 1500 0.005 0 psi to 10 psi 1500 1500 0.01 0 psi to 15 psi 1500 1500 0.01 0 psi to 25 psi 1500 1500 0.02 0 psi to 50 psi 1500 1500 0.05 0 psi to 75 psi 1500 1500 0.05 0 psi to 100 psi 1500 1500 0.1 0 psi to 150 psi 1500 1500 0.1 0 psi to 200 psi 1500 1500 0.1 0 psi to 300 psi 1500 1500 0.2 0 psi to 500 psi 1500 1500 0.5 0 psi to 750 psi 1500 1500 0.5 0 psi to 1000 psi 1500 1500 1 0 psi to 1500 psi 3500 2250 1 0 psi to 2000 psi 4000 3000 1 0 psi to 3000 psi 5000 4500 2 0 psi to 5000 psi 7000 7000 5 0 psi to 7500 psi 9500 9500 5 0 psi to 10000 psi 12000 12000 5 Incremental display steps (psi) - positive only 1 Maximum line pressure is the amount of pressure that can be placed on both sides of the diaphragm 2 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage 2 Honeywell Sensing and Control

Differential Digital Pressure Gauge Mounting dimensions and characteristics 1 TO 25 PSID 50 TO 750 PSID 1000 TO 10000 PSID For reference only 2.2 2.2 MOUNTING HOLES TYPICAL EACH SIDE 1/4-28 UNF.3125" DRAIN PORT 2X, 1/8-27 NPT 2.2 DRAIN PORT 2X, 1/8-27 NPT PRESSURE PORT 2X, 1/4-18 NPT FEMALE Request certified drawing before designing mountings or fixtures. Specifications subject to change without notice. MOUNTING HOLES TYPICAL EACH SIDE 1/4-28 UNF.3125 in 2.25 3.0 1.82 2.5 2.25 2X,.40 3.7 5.1 2.25 3.7 5.1 3.5 PRESSURE PORT 2X, 1/8-27 NPT 3.7 5.1 3.0 PRESSURE PORT 2X, 1/8-27 NPT OPTIONAL 3 FEET CABLE all pressure ranges Order guide * = Example JD REFERENCE D = Differential unit scaled from 0 psi to positive full scale value on the positive pressure side.* Bi-directional scaling is available as an option. Please consult the factory. ELECTRICAL CONNECTION Z = No electrical connection (Model JDW - 9 V battery)* C= 3 foot cable (Models JDB, JDE, JDR, JDX & JDV) T = ac adapter (Model JDT) B = Bendix (opt) PTIH-10-6P or equal (connector sold separately) W SERIES JD* MODEL DESIGNATION Models with output signal B= 4 ma to 20 ma (two-wire) E= 0 Vdc to 5 Vdc R = 2 programmable limits & relays X= 0 Vdc to 5 Vdc with two limits & relays Models with no output signal W = Battery powered (9 V alkaline)* T = 110 Vac adapter (included) V= 11 Vdc to 32 Vdc (3 ft. cable) PRESSURE RANGE (PSID) 1 = 0-1 75 = 0-75 1K = 0-1000 2 = 0-2 100= 0-100 1.5K= 0-1500 5 = 0-5* 150= 0-150 2K = 0-2000 10 =0-10 200= 0-200 3K = 0-3000 15 =0-15 300= 0-300 5K = 0-5000 25 =0-25 500= 0-500 7.5K= 0-7500 50 =0-50 750 = 0-750 10K =0-10000 Call factory for availability of other electrical connections and cable lengths. NEMA 4 CONSTRUCTION 4 = NEMA 4 (not available on Model JDT) FIELD SELECTABLE STANDARD UNITS OF MEASURE Bar = Bar Ft H20 = Feet of water MBar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mm of mercury Consult factory for other units of measure not listed 5 D Z This order code is used ONLY if you want NEMA 4 rating Honeywell Sensing and Control 3

Model JD Differential Digital Pressure Gauge Notes 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/ Vac at 1/2 A. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008714-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JG Differential Pressure Gauge DESCRIPTION The hand-held Model JG wet/wet differential pressure gauge delivers long-lasting, enhanced accuracy performance. Accuracy of 0.2 % coupled with an enhanced resolution, 4½-digit display makes this unit an excellent transfer standard for calibrating pressure measuring equipment. The JG is rugged and features high/low pressure capture with an update rate of three times per second. These units are manufactured from stainless steel and use sensor technology which has no moving parts, requires little recalibration, and has excellent overpressure tolerance. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. FEATURES High accuracy: 0.2 % full scale -1 C to 71 C [30 F to 160 F] operating temperature Enhanced resolution construction On/off switch CE compliant (certain models, consult factory) 4½ digit display with 0.5 in height Optional carrying case and panel mounting ring Optional NEMA 4 rating 9 V battery power High/low capture and store Four digit display

Model JG PERFORMANCE SPECIFICATIONS Accuracy 0.2 % full scale Maximum line pressure 500 psid High and low capture Standard Update speed 3 times per sec Mounting dimensions and characteristics ENVIRONMENTAL SPECIFICATIONS Temperature, operating -1 C to 71 C [30 F to 160 F] ELECTRICAL SPECIFICATIONS Rating NEMA 2 Power, Model JGW Power, Model JGT Power, Model JGV MECHANICAL SPECIFICATIONS Diameter Display Pressure port Wetted parts Case material Low battery indication Face membrane Calibration data 2 Honeywell Sensing and Control One or two 9 V alkaline batteries (included) 110 Vac adapter @ 60 Hz (included) (3 ft cable included) 93,98 mm [3.7 4 LCD digits - 12,7 mm [0.5 high 1/4-18 NPT male Standard Tactile feedback raised buttons Stored on memory chip Order guide * = Example SERIES JG POWER W T V B E R X = Battery powered (9 V alkaline)* = 110 Vac adapter (included) = 11 Vdc to 32 Vdc (3 ft. cable) = 4 ma to 20 ma (two-wire) = 0 Vdc to 5 Vdc = Two programmable limits & relays = 0 Vdc to 5 Vdc with limits & relays PRESSURE RANGE (PSI) 1 = 0-1(opt) 200 = 0-200* 5 = 0-5(opt) 300 = 0-300 15 = 0-15 500 = 0-500 30 = 0-30 750 = 0-750 50 = 0-50 1K = 0-1000 100 = 0-100 1.5K= 0-1500 REFERENCE D=Differential ELECTRICAL CONNECTION JG W 5 D Z = No electrical connection (Model JGW - 9 V battery)* C=3 foot cable (Model JGV) T = ac adapter (Model JGT) Call factory for availability of other electrical connections and cable lengths. OPTIONAL 4 = NEMA 4 NEMA 4 option also provides temperature range of 0-180 F OPTIONAL UNITS OF MEASURE Each gauge has the following scaling built in for field selection: Bar = Bar mbar = Millibar kpa = Kilopascals MPa = Megapascals 2K = 0-2000 3K = 0-3000 5K = 0-5000 7.5K= 0-7500 10K = 0-10000 Z Ft H20 = Feet of water In H20 = Inches of water In Hg = Inches of mercury mmhg = mm of mercury Consult factory for other units of measure not listed

Model JG NOTES 1. The limit/relay models include two LED status indicators on front face anåçd two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/Vac at 1/2 A. Accessories order codes Stainless steel Zinc-plated steel Additional specifications Pressure range (psi) Accessory SS6 AD6 Pressure adapter (Zinc plated steel) to 1/4-18 NPT female* SS7 AD7 Pressure adapter (Zinc plated steel) to 1/4-18 NPT male* SS9 AD9 Pressure adapter (Zinc plated steel) to 7/16-20 UNF male with 37 flare* CC2 MR2 NISTCERTS * Call factory for other fittings Carrying case Panel mounting ring NIST certification (in addition to NIST statement) Maximum safe over pressure (psi) 1 0 psi to 1 psi = 1 (opt) 10 0.001 0 psi to 5 psi = 5 (opt) 25 0.005 0 psi to 15 psi = 15 75 0.01 0 psi to 30 psi = 30 150 0.02 0 psi to 50 psi = 50 250 0.05 0 psi to 100 psi = 100 500 0.1 0 psi to 200 psi = 200 1000 0.1 0 psi to 300 psi = 300 1200 0.2 0 psi to 500 psi = 500 1500 0.5 0 psi to 750 psi = 750 1500 0.5 0 psi to 1000 psi = 1K 2000 1 0 psi to 1500 psi = 1.5K 3000 1 0 psi to 2000 psi = 2K 4000 1 0 psi to 3000 psi = 3K 6000 2 0 psi to 5000 psi = 5K 7500 5 0 psi to 7500 psi = 7.5K 12000 5 0 psi to 10000 psi = 10K 15000 5 Model JG 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Differential Pressure Gauge Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008713-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JH High Pressure Digital Pressure Gauge DESCRIPTION Using high pressure autoclave fittings, the Series JH digital pressure test gauge with 0.2 % full scale accuracy uses transducer technology and a stainless steel diaphragm for high over pressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JH has no moving parts and thus, may provide a long life with fewer re-calibrations. The stainless steel NEMA construction also provides EMI and RFI protection. The JH provides high resolution with an easy to read digital display. There are no operator errors due to interpolation of hash marks or parallax errors. The units can be scaled to read in various engineering units. PSI pressures are read x 10 with the 4½-digit display. The Model JHB provides a 4 ma to 20 ma, twowire output. The Model JHE provides a 0 Vdc to 5 Vdc output. The Model JHR has two programmable limits and relays with no analog output. The Model JHX provides a 0 Vdc to 5 Vdc output with two programmable limits and relays for process control or alarm indication. The Model JHW is powered by one or two common 9 V alkaline batteries. The Model JHT is powered by a 110 Vac adapter. The JHV, JHB, JHE, JHR and JHX models are powered by an 11 Vdc to 32 Vdc power supply. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be deactivated. FEATURES Pressure ranges from 15000 psi to 60000 psi gage Two programmable limits and relays (optional) Accuracy - 0.2 % full scale High and low detection - Microprocessor based 4 ma to 20 ma (two-wire) and 0 Vdc to 5 Vdc analog outputs (optional) Customer recalibration 4½ digit display with 0.5 in height Zero offset/tare On/off switch disable feature Two programmable limits and relays (optional) NEMA 4 rating (optional) NIST statement (standard) NIST traceable (optional) Optional carrying case and panel mounting ring

Model JH PERFORMANCE SPECIFICATIONS Linearity and hysteresis 0.2 % full scale (better than test gauge accuracy) Pressure range 0 psi to 15000, 20000, 25000, 30000, 35000, 40000, 50000, 60000 psi High and low capture Update speed Zero and span signal adjustment Standard 3 times per sec Standard: Models JHB, JHE, JHX ADDITIONAL SPECIFICATIONS Pressure range (psi) Maximum safe over pressure (psi) 2 0 psi to 15000 psi = 15K 20000 1 x 10 0 psi to 20000 psi = 20K 25000 1 x 10 0 psi to 25000 psi = 25K 31000 1 x 10 0 psi to 30000 psi = 30K 37000 2 x 10 0 psi to 35000 psi = 35K 43000 5 x 10 0 psi to 40000 psi = 40K 50000 5 x 10 Incremental display steps 0 psi to 50000 psi = 50K 62000 5 x 10 ENVIRONMENTAL SPECIFICATIONS Temperature, operating -1 C to 71 C [30 F to 160 F] 0 psi to 60000 psi = 60K 75000 5 x 10 2 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage ELECTRICAL SPECIFICATIONS Mounting dimensions and characteristics Rating NEMA 2 (optional NEMA 4) Power, Model JHW Power, Model JHT Power, Model JHV Power, Model JHB Power, Model JHE Power, Model JHR Power, Model JHX Electrical connection One or two 9 V alkaline batteries (included) 110 Vac adapter @ 60 Hz (included) (3 ft cable included) 11 Vdc to 32 Vdc (depending on loop resistance) @ 20 ma 3 ft cable standard: Models JHB, JHE, JHR, JHX, JHV MECHANICAL SPECIFICATIONS Diameter Display Pressure port Wetted parts Case material Face membrane Calibration data Low battery indication 93,98 mm [3.7 4½ LCD digits - 12,7 mm [0.5 high 9/16-18 UNF-2B female (per Autoclave AE F 250-C) Tactile feedback raised buttons Stored on memory chip Standard: Model JHW For reference only Limits and relays Models JHR and JHX 1 2 Honeywell Sensing and Control

Model JH Order guide ORDER CODE * = Example SERIES JH* MODEL DESIGNATION Models with Output Signal B= 4 ma to 20 ma (two-wire) E= 0 Vdc to 5 Vdc R = 2 programmable limits & relays X= 0 Vdc to 5 Vdc with two limits & relays Models with No Output Signal W = Battery powered (9 V alkaline) * T = 110 Vac adapter (included) V = 11 Vdc to 32 Vdc (3 ft cable) PRESSURE RANGE (PSI) 15K = 0-15000 35K = 0-35000 20K = 0-20000 40K = 0-40000 25K = 0-25000 50K = 0-50000* 30K = 0-30000 60K = 0-60000 REFERENCE G = Gage - Unit reads zero at atmosphere* ELECTRICAL CONNECTION NEMA 4 CONSTRUCTION 4 = NEMA 4 (not available on Model JHT) JH W 50K G Z ( ) Z = No electrical connection (Model JHW - 9 V battery)* C = 3 foot cable T = ac adapter (Model JHT) B = Bendix (opt) PTIH-10-6P or equal (connector sold separately) Call factory for availability of other electrical connections and cable lengths. FIELD SELECTABLE STANDARD UNITS OF MEASURE Bar = Bar Ft H20 = Feet of water MBar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mm of mercury Consult factory for other units of measure not listed This order code is used ONLY if you want NEMA 4 rating NOTES 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/ Vac at 1/2 A. High Pressure Digital Pressure Gauge Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008691-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JK Digital Pressure Gauge DESCRIPTION The Series JK digital pressure test gauge with 0.2 % full scale accuracy uses transducer technology and a stainless steel diaphragm for high overpressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JK has no moving parts and thus, may provide a long life with fewer re-calibrations. The stainless steel NEMA construction also provides EMI and RFI protection. The JK provides high resolution with an easy to read digital display. There are no operator errors due to interpolation of hash marks or parallax errors. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. The Model JKW is powered by one or two common 9 V alkaline batteries. The Model JKT is powered by a 110 Vac adapter. The Model JKV is powered by an 11 Vdc to 32 Vdc power supply. FEATURES Ranges to 10000 psi 0.2 % accuracy Field selectable engineering units Available -18 C to 82 C [0 F to 180 F] operating temperature 4 construction 4½ digit display with 0.5 in height Customer recalibration 9 V battery power High/low capture and store On/off switch CE compliant (certain models, consult factory) Optional carrying case and panel mounting ring

Model JK PERFORMANCE SPECIFICATIONS Range Accuracy 0.2 % 1 Update speed See additional specifications table 3 per second ENVIRONMENTAL SPECIFICATIONS Temperature, operating Rating ELECTRICAL SPECIFICATIONS Display Power supply, Model JKW Power supply, Model JKT Power supply, Model JKV Electrical connection Low battery indication Calibration data High and low capture -1 C to 71 C [30 F to 160 F] (-18 C to 82 C [0 F to 180 F] with optional NEMA 4 rating) NEMA 2, std. (NEMA 4 optional except model JKT) LCD, 4 1/2-digit, 1,3 cm [0.5 high 1 or 2 9-volt batteries (included) 110 volt ac adaptor @ 60 Hz (included) 0,9 m [3 ft] cable (std.) for model JKV Standard on model JKW Stored on memory chip Standard ADDITIONAL SPECIFICATIONS Pressure range (psi) Max. safe over pressure (psi) Incremental display steps Pressure range (psi) Max. safe over pressure (psi) Incremental display steps 1 5 15 30 50 100 200 300 500 10 25 75 150 250 500 1000 1200 1500 0.001 0.005 0.01 0.02 0.05 0.1 0.1 0.2 0.5 750 1000 1500 2000 3000 5000 7500 10000 1500 2000 3000 4000 6000 7500 12000 15000 0.5 1 1 1 2 5 5 5 Mounting dimensions and characteristics MECHANICAL SPECIFICATIONS Pressure port Face membrane Case material Wetted parts 1-4/18 NPT male (300 psi and below) 9/16-18 UNF - 2B female straight thread with SAE spec J514 o-ring boss (500 psi and above) Tactile feedback raised buttons For reference only 2 Honeywell Sensing and Control

Model JK Order guide * = Example JK* POWER W T V = Battery powered (9 V alkaline)* = 110 Vac adapter (included) = 11 Vdc to 32 Vdc (3 ft. cable) PRESSURE RANGE (PSI) 1 = 0-1(opt) 200 = 0-200* 5 = 0-5(opt) 300 = 0-300 15 = 0-15 500 = 0-500 30 = 0-30 750 = 0-750 50 = 0-50 1K = 0-1000 100 = 0-100 1.5K = 0-1500 JK 2K = 0-2000 3K = 0-3000 5K = 0-5000 7.5K= 0-7500 10K = 0-10000 REFERENCE G = Gage (std) reads zero at atmosphere * A = Absolute (opt) reads zero at vacuum (15 psi or higher) V = Vacuum (opt) C = Compound (opt) reads both positive & negative (vacuum) pressure ELECTRICAL CONNECTION Z = No electrical connection (Model JKW - 9 volt battery)* C= 3 foot cable (Model JKV) T = ac adapter (Model JKT) Call factory for availability of other electrical connections and cable lengths. OPTIONAL 4 = NEMA 4 (Not available on JKT) NEMA 4 option also provides temperature range of 0-180 F FIELD SELECTABLE STANDARD UNITS OF MEASURE Each gauge has the following scaling built in for field selection: Bar = Bar mbar = Millibar kpa = Kilopascals MPa = Megapascals W 200 NOTES 1. Accuracies stated are for best fit straight line for all errors including linearity, hysteresis and repeatability through zero. 2. Consult factory for optional units of measure. 3. Consult factory for optional electrical connectors and cable lengths. 4. -18 C to 82 C [0 F to 180 F] operating temperature only with optional NEMA 4 rating. Z Ft H20 = Feet of water In H20 = Inches of water In Hg = Inches of mercury mmhg = mm of mercury Consult factory for other units of measure not listed G 4 Digital Pressure Gauge Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008692-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JP Food/Pharmaceutical Digital Pressure Gauge DESCRIPTION Using Tri-Clover sanitary fittings, the Series JP digital pressure test gauge with 0.2% full scale accuracy uses transducer technology and a stainless steel diaphragm for high over pressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JP has no moving parts and thus, may provide a long life with fewer re-calibrations. The stainless steel NEMA construction also provides EMI and RFI protection. The JP provides high resolution with an easy to read 4½-digit display. There are no operator errors due to interpolation of hash marks or parallax errors. The units can be scaled to read in various engineering units such as InHg, Ft H 2 O, etc. The Model JPB provides a 4 ma to 20 ma, two-wire output. The Model JPE provides a 0 Vdc to 5 Vdc output. The Model JPR has two programmable limits and relays with no analog output. The Model JPX provides a 0 Vdc to 5 Vdc output with two programmable limits and relays for process control or alarm indication. The Model JPW is powered by one or two common 9 V alkaline batteries. The Model JPT is powered by a 110 Vac adapter. The Model JPV is powered by an 11 Vdc to 32 Vdc power supply. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. FEATURES Tri-Clover sanitary fittings Two programmable limits and relays (optional) Test gauge accuracy - 0.2 % full scale High and low detection - Microprocessor based NEMA 4 4½ digit display with 0.5 in height Customer recalibration Zero offset/tare On/off switch disable feature Optional carrying case and panel mounting ring Two programmable limits and relays (optional) NIST traceable (optional)

Model JP PERFORMANCE SPECIFICATIONS Linearity and hysteresis Pressure range 0 psi to High and low capture Update speed Zero and span signal adjustment 2 Honeywell Sensing and Control 0.2 % full scale (better than test gauge accuracy) 1, 2, 5, 10, 20, 50, 100, 200, 500 psi Standard 3 times per sec Standard: Models JPB, JPE, JPX ENVIRONMENTAL SPECIFICATIONS Temperature, operating ELECTRICAL SPECIFICATIONS -1 C to 71 C [30 F to 160 F] Rating NEMA 4 Power, Model JPW Power, Model JPT Power, Model JPV Power, Model JPB Power, Model JPE Power, Model JPR Power, Model JPX Electrical connection MECHANICAL SPECIFICATIONS Diameter Display Pressure port Wetted parts Case material Face membrane Calibration data Low battery indication Limits and relays One or two 9 V alkaline batteries (included) 110 Vac adapter @ 60 Hz (included) (3 ft cable included) 11 Vdc to 32 Vdc (depending on loop resistance) @ 20 ma 3 ft cable standard: Models JPB, JPE, JPR, JPX, JPV 93,98 mm [3.7 4½ LCD digits - 12,7 mm [0.5 high Sanitary flanges: 1.5 in, 2.0 in, 2.5 in, 3.0 in Tactile feedback raised buttons Stored on memory chip Standard: Model JPW Models JPR and JPX* ADDITIONAL SPECIFICATIONS Pressure range 0 to: (psi) Mounting dimensions and characteristics 2.2 2.0" TRI-CLOVER SANITARY FLANGE Maximum safe over pressure (psi) 1, 2 1.5 in flange dia. 2.0 in flange dia. 3 FEET CABLE EXIT * 3.7 1.5" TRI-CLOVER SANITARY FLANGE Request certified drawing before designing mountings or fixtures. Specifications subject to change without notice. For reference only 5.2 2.5" TRI-CLOVER SANITARY FLANGE 2.5 in flange dia. 1.2 *Models JPB, JPE, JPR, JPX, JPV No cable for battery powered Model JPW 3.0 in flange dia. 3.0" TRI-CLOVER SANITARY FLANGE Incremental display steps 1 (opt) 10 10 10 10 0.001 2 (opt) 15 15 15 15 0.002 5 (opt) 25 25 25 25 0.005 10 50 50 50 50 0.01 15 75 75 75 75 0.01 25 125 125 125 125 0.02 50 250 250 250 250 0.05 100 500 500 500 350 0.1 250 600 600 600 350 0.2 400 600 600 600 NA 0.5 500 600 600 NA NA 0.5 Max. flange pressure at 100 F 600 600 600 350 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage. 2 Maximum pressure: 1 1/2, 2, 2 1/2 inch dia. flange - 600 psi at 100 F; 3 inch dia. flange - 350 psi at 100 F temperatures above; 100 F reduce maximum flange pressure. Please call factory.

Model JP Order guide JP * = Example SERIES JP* MODEL DESIGNATION Models with output signal B= 4 ma to 20 ma (two-wire) E= 0 Vdc to 5 Vdc R = Two programmable limits & relays X= 0 Vdc 5 Vdc with two limits & relays Models with no output signal W= Battery powered (9 V alkaline) * T = 110 Vac adapter (included) V= 11 Vdc to 32 Vdc (3 ft. cable) NOTES 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/ Vac at 1/2 A. W PRESSURE RANGE (PSI) 1 = 0-1 (opt) 15 = 0-15 250= 0-250* 2 = 0-2 (opt) 25 = 0-25 400= 0-400 5 = 0-5 (opt) 50 = 0-50 500= 0-500 10 =0-10 100 = 0-100 250 REFERENCE G = Gage (std) reads zero at atmosphere* A = Absolute (opt) reads zero at vacuum (15 psi or higher) V = Vacuum (opt) scaled in In Hg (15 psi or lower) C = Compound (opt) reads both positive and negative (vacuum) pressure ELECTRICAL CONNECTION Z = No electrical connection (Model JPW - 9 V battery)* C = 3 foot cable T = ac adapter (Model JPT) B = Bendix (opt) PTIH-10-6P or equal (connector sold separately) Call factory for availability of other electrical connections and cable lengths. SANITARY FLANGE SIZE : P = 1.5 inches (up to 500 psi) (does not comply with 3A standards) Q=2.0 inches (up to 500 psi) R = 2.5 inches (up to 400 psi) S = 3.0 inches (up to 250 psi) FIELD SELECTABLE STANDARD UNITS OF MEASURE Bar = Bar Ft H20 = Feet of water MBar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mm of mercury Consult factory for other units of measure not listed G Z Food/Pharmaceutical Digital Pressure Gauge Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008693-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JR Remote Pressure Digital Pressure Gauge DESCRIPTION With a 6-ft microchange cable connection, the Model JR digital pressure test gauge with 0.2 % full scale accuracy uses transducer technology and a stainless steel diaphragm for high over pressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JR has no moving parts and may provide a long life with fewer re-calibrations. The JR provides high resolution with an easy to read 4½-digit display. There are no operator errors due to interpolation of hash marks or parallax errors. The units can be scaled to read in various engineering units such as InHg, Ft H 2 O, etc. The Model JRB provides a 4 ma to 20 ma, two-wire output. The Model JRE provides a 0 Vdc to 5 Vdc output. The Model JRR has two programmable limits and relays with no analog output. The Model JRX provides a 0 Vdc to 5 Vdc output with two programmable limits and relays for process control or alarm indication. The Model JRW is powered by one or two common 9 V alkaline batteries. The Model JRT is powered by a 110 Vac adapter. The Model JRV is powered by an 11 Vdc to 32 Vdc power supply. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. FEATURES Portable battery powered available Two programmable limits and relays (optional) Test gauge accuracy - 0.2 % full scale High and low detection - Microprocessor based Ranges to 60000 psi - gage, absolute, vacuum, or compound Optional pressure port adapters 4½ digit display with 0.5 in height Customer recalibration Zero offset/tare On/off switch disable feature Optional carrying case and panel mounting ring NEMA 4 rating (optional) NIST traceable (optional)

Model JR PERFORMANCE SPECIFICATIONS Linearity and hysteresis 0.2 % full scale (better than test gauge accuracy) Pressure range 0 psi to 1, 5, 15, 30, 50, 100, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10000 psi (see Series JH for ranges above 10000 psi) High and low capture Update speed Zero and span signal adjustment Standard 3 times per sec ENVIRONMENTAL SPECIFICATIONS Temperature, operating Standard: Models JRB, JRE, JRX ELECTRICAL SPECIFICATIONS -1 C to 71 C [30 F to 160 F] Rating NEMA 2 (optional NEMA 4) Power, Model JRW Power, Model JRT One or two 9 V alkaline batteries (included) 110 Vac adapter @ 60 Hz (included) ADDITIONAL SPECIFICATIONS Pressure range (psi) Maximum safe over pressure (psi) 1 Model JR 0 psi to 1 psi = 1 (opt) 10 0.001 0 psi to 5 psi = 5 (opt) 25 0.005 0 psi to 15 psi = 15 75 0.01 0 psi to 30 psi = 30 150 0.02 0 psi to 50 psi = 50 250 0.05 0 psi to 100 psi = 100 500 0.1 0 psi to 200 psi = 200 1000 0.1 0 psi to 300 psi = 300 1200 0.2 0 psi to 500 psi = 500 1500 0.5 0 psi to 750 psi = 750 1500 0.5 0 psi to 1000 psi = 1K 2000 1 0 psi to 1500 psi = 1.5K 3000 1 0 psi to 2000 psi = 2K 4000 1 0 psi to 3000 psi = 3K 6000 2 0 psi to 5000 psi = 5K 7500 5 0 psi to 7500 psi = 7.5K 12000 5 0 psi to 10000 psi = 10K 15000 5 (See Series JH for ranges above 10000 psi) Power, Model JRV Power, Model JRB Power, Model JRE Power, Model JRR Power, Model JRX Electrical connection (3 ft cable included) 11 Vdc to 32 Vdc (depending on loop resistance) @ 20 ma 3 ft from back of unit to power supply: Models JRB, JRE, JRR, JRX, JRV 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Mounting dimensions and characteristics MECHANICAL SPECIFICATIONS Diameter Display Pressure port Wetted parts Case material Face membrane Calibration data Low battery indication Limits and relays 93,98 mm [3.7 4½ LCD digits - 12,7 mm [0.5 high 1/4-18 NPT male (1 psi to 300 psi); 9/16-18 UNF-2B female straight thread with SAE spec J514 o-ring boss (500 psi and above) Tactile feedback raised buttons Stored on memory chip Standard: Model JRW Models JRR and JRX 2 Honeywell Sensing and Control For reference only

Model JR Order guide * = Example SERIES JR* MODEL DESIGNATION Models with output signal B= 4 ma to 20 ma (two-wire) E= 0 Vdc to 5 Vdc R = Two programmable limits & relays X= 0 Vdc to 5 Vdc with two limits & relays Models with No Output Signal W= Battery powered (9 volt alkaline) * T = 110 Volt AC adapter (included) V= 11 to 32 VDC (3 ft. cable) PRESSURE RANGE (PSI) 1 = 0-1(opt) 200 = 0-200* 5 = 0-5(opt) 300 = 0-300 15 =0-15 30 =0-30 500 = 0-500 750 = 0-750 50 =0-50 1K = 0-1000 100= 0-100 1.5K = 0-1500 See Series JH for ranges above 10,000 psi. JR W 200 G Z ( ) 2K = 0-2000 3K = 0-3000 5K = 0-5000 7.5K = 0-7500 10K =0-10000 REFERENCE G= Gage (std) reads zero at atmosphere* A = Absolute (opt) reads zero at vacuum(15 psi or higher) V = Vacuum (opt) scaled in inches of mercury (15 psi or lower) C = Compound (opt) reads both positive and negative (vacuum) pressure ELECTRICAL CONNECTION Z = No electrical connection (Model JRW - 9 V battery)* C = 3 foot cable T = ac adapter (Model JRT) B = Bendix (opt) PTIH- 10-6P or equal (connector sold separately - back connection only) Call Factory for availability of other electrical connections and cable lengths. NEMA 4 CONSTRUCTION 4 = NEMA 4 (Not available on Model JRT) FIELD SELECTABLE STANDARD UNITS OF MEASURE Bar = Bar Ft H20 = Feet of water MBar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mm of mercury Consult factory for other units of measure not listed This order code is used ONLY if you want NEMA 4 rating NOTES 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/ Vac at 1/2 A. Remote Pressure Digital Pressure Gauge Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008694-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JS Digital Pressure Gauge With Output DESCRIPTION The Model JS digital pressure test gauge with 0.2 % full scale accuracy uses transducer technology and a stainless steel diaphragm for high over pressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JS has no moving parts and thus, may provide a long life with fewer re-calibrations. The stainless steel NEMA construction also provides EMI and RFI protection. The JS provides high resolution with an easy to read digital display. There are no operator errors due to interpolation of hash marks or parallax errors. The units can be scaled to read in various engineering units such as InHg, Ft H 2 O, etc. The Model JSB provides a 4 ma to 20 ma, two-wire output. The Model JSE provides a 0 Vdc to 5 Vdc output. The Model JSR has two programmable limits and relays with no analog output. The Model JSX provides a 0 Vdc to 5 Vdc output with two programmable limits and relays for process control or alarm indication. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. FEATURES 4 ma to 20 ma (two-wire) and 0 Vdc to 5 Vdc analog outputs Two programmable limits and relays (optional) Test gauge accuracy - 0.2 % full scale High and low detection - Microprocessor based Ranges to 10000 psi - gage, absolute, vacuum, or compound 4½ digit display with 0.5 in height Customer recalibration Zero offset/tare On/off switch disable feature Optional carrying case and panel mounting ring Optional pressure port adapters NEMA 4 rating (optional) NIST traceable (optional)

Model JS PERFORMANCE SPECIFICATIONS Linearity and hysteresis 0.2 % full scale (better than test gauge accuracy) Pressure range 0 psi to 1, 5, 15, 30, 50, 100, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10000 psi High and low capture Update speed Zero and span signal adjustment Standard 3 times per sec Standard: Models JSB, JSE, JSX ADDITIONAL SPECIFICATIONS Pressure range (psi) Maximum safe over pressure (psi) 1 Model JS 0 psi to 1 psi = 1 (opt) 10 0.001 0 psi to 5 psi = 5 (opt) 25 0.005 0 psi to 15 psi = 15 75 0.01 0 psi to 30 psi = 30 150 0.02 0 psi to 50 psi = 50 250 0.05 0 psi to 100 psi = 100 500 0.1 0 psi to 200 psi = 200 1000 0.1 0 psi to 300 psi = 300 1200 0.2 ENVIRONMENTAL SPECIFICATIONS Temperature, operating -1 C to 71 C [30 F to 160 F] 0 psi to 500 psi = 500 1500 0.5 0 psi to 750 psi = 750 1500 0.5 0 psi to 1000 psi = 1K 2000 1 0 psi to 1500 psi = 1.5K 3000 1 0 psi to 2000 psi = 2K 4000 1 ELECTRICAL SPECIFICATIONS Rating NEMA 2 (optional NEMA 4) Power, Model JSB Power, Model JSE 11 Vdc to 32 Vdc (depending on loop resistance) @ 20 ma 0 psi to 3000 psi = 3K 6000 2 0 psi to 5000 psi = 5K 7500 5 0 psi to 7500 psi = 7.5K 12000 5 0 psi to 10000 psi = 10K 15000 5 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Power, Model JSR Power, Model JSX Electrical connection 3 ft cable (standard) Mounting dimensions and characteristics MECHANICAL SPECIFICATIONS Diameter Display Pressure port Wetted parts Case material Face membrane Calibration data Limits and relays 93,98 mm [3.7 4½ LCD digits - 12,7 mm [0.5 high 1/4-18 NPT male (1 psi to 300 psi); 9/16-18 UNF-2B female straight thread with SAE spec J514 o-ring boss (500 psi and above) Tactile feedback raised buttons Stored on memory chip Models JSR and JSX For reference only 2 Honeywell Sensing and Control

Model JS Order guide * = Example SERIES JS* OUTPUT SIGNAL B= 4 ma to 20 ma (two-wire)* E= 0 Vdc to 4 Vdc R = 2 programmable limits & relays X= 0 Vdc to 5 Vdc with two limits & relays PRESSURE RANGE (PSI) 1 = 0-1 (opt) 100 = 0-100 5 = 0-5 (opt) 200 = 0-200* 15 = 0-15 300 = 0-300 30 = 0-30 500 = 0-500 50 = 0-50 750 = 0-750 REFERENCE G = Gage (std) reads zero at atmosphere* A = Absolute (opt) reads zero at vacuum (15 psi or higher) V = Vacuum (opt) scaled in In Hg (15 psi or lower) C= Compound (opt) reads both positive and negative (vacuum) pressure ELECTRICAL CONNECTION JS NOTES 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/ Vac at 1/2 A. B 200 1K = 0-1000 1.5K= 0-1500 2K = 0-2000 3K = 0-3000 5K = 0-5000 7.5K= 0-7500 10K = 0-10000 C = 3 foot cable* B = Bendix (opt) - PTIH-10-6P or equal (connector sold seperately) Call factory for availability of other electrical connections and cable lengths NEMA 4 CONSTRUCTION 4 = NEMA 4 FIELD SELECTABLE STANDARD UNITS OF MEASURE Bar = Bar Ft H20 = Feet of water MBar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mm of mercury Consult factory for other units of measure not listed G C ( ) This order code is used ONLY if you want NEMA 4 rating Digital Pressure Gauge With Output Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008695-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model JV Digital Pressure Gauge With VCR Fittings DESCRIPTION Using VCR, the Series JV digital pressure test gauge with 0. 2% full scale accuracy uses transducer technology and a stainless steel diaphragm for high over pressure protection. The transducer technology provides enhanced accuracy over the entire pressure range. The JV has no moving parts and thus, may provide a long life with fewer re-calibrations. The stainless steel NEMA construction also provides EMI and RFI protection. The JV provides high resolution with an easy to read digital display. There are no operator errors due to interpolation of hash marks or parallax errors. The units can be scaled to read in various engineering units, such as in-hg, ft-h 2 0, etc. The Model JVB provides a 4 ma to 20 ma, two-wire output. The Model JVE provides a 0 Vdc to 5 Vdc output. The Model JVR has two programmable limits and relays with no analog output. The Model JVX provides a 0 Vdc to 5 Vdc output with two programmable limits and relays for process control or alarm indication. The Model JVW is powered by one or two common 9 V alkaline batteries. The Model JVT is powered by a 110 Vac adapter. The JVV, JVB, JVE, JVR, and JVX models are powered by an 11 Vdc to 32 Vdc power supply. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be deactivated. FEATURES Passivation or oxygen-cleaned options Two programmable limits and relays (optional) Test gauge accuracy - 0.2 % full scale High and low detection - Microprocessor based Ranges to 5000 psi - gage, absolute, vacuum, or compound 4½ digit display with 0.5 in height Customer recalibration Zero offset/tare On/off switch disable feature Optional carrying case and panel mounting rings NEMA 4 rating (optional) NIST traceable (optional)

Model JV PERFORMANCE SPECIFICATIONS Linearity and hysteresis 0.2 % full scale (better than test gauge accuracy) Pressure range 0 psi to 1, 5, 15, 30, 50, 100, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10000 psi High and low capture Update speed Zero and span signal adjustment Standard 3 times per sec Standard: Models JVB, JVE, JVX ADDITIONAL SPECIFICATIONS Pressure range (psi) Maximum safe over pressure (psi) 1 Model JV 0 psi to 1 psi = 1 (opt) 10 0.001 0 psi to 5 psi = 5 (opt) 25 0.005 0 psi to 15 psi = 15 75 0.01 0 psi to 30 psi = 30 150 0.02 0 psi to 50 psi = 50 250 0.05 0 psi to 100 psi = 100 500 0.1 0 psi to 200 psi = 200 1000 0.1 0 psi to 300 psi = 300 1200 0.2 ENVIRONMENTAL SPECIFICATIONS Temperature, operating -1 C to 71 C [30 F to 160 F] 0 psi to 500 psi = 500 1500 0.5 0 psi to 750 psi = 750 1500 0.5 0 psi to 1000 psi = 1K 2000 1 0 psi to 1500 psi = 1.5K 3000 1 0 psi to 2000 psi = 2K 4000 1 ELECTRICAL SPECIFICATIONS Rating NEMA 2 (optional NEMA 4) Power, Model JVW Power, Model JVT One or two 9 V alkaline batteries (included) 110 Vac adapter @ 60 Hz (included) 0 psi to 3000 psi = 3K 6000 2 0 psi to 5000 psi = 5K 7500 5 0 psi to 7500 psi = 7.5K 12000 5 0 psi to 10000 psi = 10K 15000 5 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Power, Model JVV Power, Model JVB Power, Model JVE Power, Model JVR Power, Model JVX Electrical connection (3 ft cable included) 11 Vdc to 32 Vdc (depending on loop resistance) @ 20 ma 3 ft cable (standard) on Models: JVB, JVE, JVR, JVX, JVV Mounting dimensions and characteristics MECHANICAL SPECIFICATIONS Diameter Display Pressure port Wetted parts Case material Face membrane Calibration data Low battery indication Limits and relays 93,98 mm [3.7 4½ LCD digits - 12,7 mm [0.5 high Size 4 stainless steel VCR (male) (Other VCR parts available. Consult factory) Tactile feedback raised buttons Stored on memory chip Standard on Model JVW Models JVR and JVX For reference only 2 Honeywell Sensing and Control

Model JV Order guide JV * = Example SERIES JV* MODEL DESIGNATION Models with output signal B= 4 ma to 20 ma (two-wire) E= 0 Vdc to 5 Vdc R = 2 programmable limits & relays X= 0 Vdc to 5 Vdc with two limits & relays Models with no output signal W= Battery powered (9 V alkaline)* T=110 Vac adapter (included) V= 11 Vdc to 32 Vdc (3 ft. cable) PRESSURE RANGE (PSI) 1 = 0-1 (opt) 100= 0-100* 5 = 0-5 (opt) 200= 0-200 15 =0-15 30 =0-30 50 =0-50 300= 0-300 500= 0-500 750= 0-750 1K =0-1000 REFERENCE NOTES 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/ Vac at 1/2 A. W 100 1.5K = 0-1500 2K = 0-2000 3K = 0-3000 5K = 0-5000 7.5K = 0-7500 10K = 0-10000 G = Gage (std) reads zero at atmosphere* A = Absolute (opt) reads zero at vacuum (15 psi or higher) V = Vacuum (opt) scaled in In Hg (15 psi or lower) C = Compound (opt) reads both positive and negative (vacuum) pressure ELECTRICAL CONNECTION Z = No electrical connection (Model JVW - 9 V battery)* C = 3 foot cable T = ac adapter (Model JVT) B = Bendix (opt) (PTIH-10-6P or equal) connector sold separately Call factory for availability of other electrical connections and cable lengths. VCR PRESSURE FITTING V = Size 4 stainless steel VCR (male)* Other VCR ports available. Please call factory. NEMA 4 CONSTRUCTION 4 = NEMA 4 (not available on Model JVT) FIELD SELECTABLE STANDARD UNITS OF MEASURE Bar = Bar Ft H20 = Feet of water MBar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mm of mercury Consult factory for other units of measure not listed G Z V ( ) This order code is used ONLY if you want NEMA 4 rating Digital Pressure Gauge With VCR Fittings Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008696-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model PI Intrinsically Safe Pressure Gauge DESCRIPTION As an in-process gauge or portable calibrator, the hand-held Model PI delivers long-lasting, enhanced accuracy performance. Accuracy of 0.2 % coupled with an enhanced resolution, 4½-digit display makes this unit an excellent transfer standard for calibrating pressure measuring equipment. The PI is rugged and features high/low pressure capture with a field-adjustable update rate from three-to-ten times per second. These units are manufactured from stainless steel and use sensor technology which has no moving parts, requires little recalibration and has excellent overpressure tolerance. NEMA 4 rating provides EMI and RFI protection. Units of measure are fieldselectable and the unit is offered with gage, absolute, vacuum, or compound reference. The Model PIW is powered by one or two common 9 V alkaline batteries. The PI Digital Gauges have the following complete Factory Mutual Approved Classifications: Class I: Gases and vapor Class II: Combustible dust Class III: Fibers Intrinsically safe systems limit the thermal and electrical energy to the hazardous area to help prevent ignition. Division 1: present or likely to be present in normal operation Division 2: not present in normal operation Group A: Acetylene Group B: Hydrogen Group C: Acetaldehyde, Ethylene, Methyl Ether Group D: Acetone, Gasoline, Methanol, Propane Group E: Metal dust Group F: Carbon dust Group G: Grain dust FEATURES High accuracy: 0.2 % full scale Factory Mutual approved Ranges to 10000 psi - gage, absolute, vacuum, or compound construction On/off switch CE compliant 9 V battery power Optional pressure ports Optional carrying case and panel mounting ring High/low capture and store 4½-digit display with 0.5 in height

Model PI PERFORMANCE SPECIFICATIONS Accuracy 0.2 % of full scale BSFL Pressure range, 0 psi to: 15, 50, 100, 200, 500, 750, 1000, 1500, 2000, 5000, 7500, 10000 psi High and low capture Update speed Standard 3 per sec ADDITIONAL SPECIFICATIONS Pressure range (psi) Maximum safe over pressure (psi) 1 0 psi to 15 psi = 15 75 0.01 0 psi to 50 psi = 50 250 0.05 0 psi to 100 psi = 100 500 0.1 0 psi to 200 psi = 200 1000 0.1 Incremental display steps 0 psi to 500 psi = 500 1500 0.5 ENVIRONMENTAL SPECIFICATIONS Temperature, operating (standard) Temperature, operating (optional) -1 C to 71 C [30 F to 160 F] -18 C to 82 C [0 F to 180 F] 0 psi to 750 psi = 750 1500 0.5 0 psi to 1000 psi = 1K 2000 1 0 psi to 1500 psi = 1.5K 3000 1 0 psi to 2000 psi = 2K 4000 1 0 psi to 5000 psi = 5K 7500 5 0 psi to 7500 psi = 7.5K 12000 5 0 psi to 10000 psi = 10K 15000 5 ELECTRICAL SPECIFICATIONS 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Rating Power, Model PIW Power, Model PIV NEMA 4 (also provides temperature range of -18 C to 82 C [0 F to 180 F]) One or two 9 V alkaline batteries (included) (3 ft cable included) Mounting dimensions and characteristics MECHANICAL SPECIFICATIONS Diameter Display Pressure port Wetted parts Case material Low battery indication Face membrane Calibration data 93,98 mm [3.7 4 LCD digits - 12,7 mm [0.5 high 9/16-18 UNF-2B - female straight thread with SAE spec J514 o-ring boss Standard Tactile feedback raised buttons Stored on memory chip For reference only 2 Honeywell Sensing and Control

Model PI Order code * = Example SERIES PI POWER W Notes = Battery powered (9 v alkaline)* PRESSURE RANGE (psi) 15 = 0-15 50 = 0-50 100 = 0-100 200 = 0-200* 500 = 0-500 750 = 0-750 1K = 0-1000 1.5K= 0-1500 PI W 200 G REFERENCE G = Gage (std) reads zero at atmosphere * A = Absolute (opt) reads zero at vacuum (15 psi or higher) V = Vacuum (opt) scaled in In Hg (15 psi or lower) C = Compound (opt) reads both positive & negative (vacuum) pressure ELECTRICAL CONNECTION 2K = 0-2000 5K = 0-5000 7.5K= 0-7500 10K = 0-10000 Z = No electrical connection (Model PIW - 9 V battery)* Call factory for availability of other electrical connections and cable lengths. NEMA (STANDARD) 4 = NEMA 4 FIELD SELECTABLE STANDARD UNITS OF MEASURE Each gage has the following scaling built in for field selection: Bar = Bar Ft H20 = Feet of water mbar = Millibar In H20 = Inches of water kpa = Kilopascals In Hg = Inches of mercury MPa = Megapascals mmhg = mmof mercury Consult factory for other units of measure not listed 1. The limit/relay models include two LED status indicators on front face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/Vac at 1/2 A. Z 4 Intrinsically Safe Pressure Gauge Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008685-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Models AC and JC Portable Pressure Calibrators DESCRIPTION Constructed with stainless steel wetted parts and totally portable, the JC and AC Series pressure calibrators can handle many rugged applications and harsh environments. The circuitry is designed to withstand dropping and is immune to electromagnetic interference. The calibrators are fully battery powered (9 V) so they are easily transportable from site to site. This versatile pressure calibrator is available in two accuracies: JC Series with 0.2 % accuracy and AC Series with 0.05 % accuracy. The calibrators have a 4½-digit display for accurate and easy readings. The high/low feature captures and holds both the highest and lowest pressure reading. (Press clear or off to reset). Operating temperatures are from -18 C to 82 C [0 F to 180 F]. The set includes the digital gauge, carrying case, NIST certificate, and pressure adapter. FEATURES 0.2 % and 0.05% full scale accuracy Field selectable engineering units High and low and peak memory function Wetted stainless steel construction High over-pressure protection 4½ digit display with 0.5 in height EMI and RFI shielding for all types of industrial environments NIST traceable (standard) NEMA 4 rated for harsh environments Optional pressure ports Optional carrying case and panel mounting ring NIST traceable (optional)

Models AC and JC PERFORMANCE SPECIFICATIONS Additional specifications Accuracy, JC Series 0.2 % of full scale Incremental display steps Accuracy, AC Series 0.05 % of full scale Pressure range (psi) Maximum safe over pressure (psi) 1 Model JC Model AC ENVIRONMENTAL SPECIFICATIONS Temperature, operating (standard) Temperature, operating (optional) ELECTRICAL SPECIFICATIONS Display, AC Series Display, JC Series -1 C to 71 C [30 F to 160 F] -18 C to 82 C [0 F to 180 F] (NEMA 4 AK only option required) 4½ LCD digits, 0.5 in high 4 LCD digits, 0.5 in high 0 psi to 1 psi = 1 (opt) 10 0.001 0 psi to 5 psi = 5 (opt) 25 0.005 0 psi to 15 psi = 15 75 0.01 0.005 0 psi to 30 psi = 30 150 0.02 0 psi to 50 psi = 50 250 0.05 0.01 0 psi to 100 psi = 100 500 0.1 0.02 0 psi to 200 psi = 200 1000 0.1 0.05 0 psi to 300 psi = 300 1200 0.2 0 psi to 500 psi = 500 1500 0.5 0.1 0 psi to 750 psi = 750 1500 0.5 0.2 0 psi to 1000 psi = 1K 2000 1 0.2 0 psi to 1500 psi = 1.5K 3000 1 0.5 0 psi to 2000 psi = 2K 4000 1 0.5 0 psi to 3000 psi = 3K 6000 2 MECHANICAL SPECIFICATIONS Wetted parts 0 psi to 5000 psi = 5K 7500 5 1 0 psi to 7500 psi = 7.5K 12000 5 2 0 psi to 10000 psi = 10K 15000 5 2 Case material High and low capture Calibration data Standard Stored on memory chip 1 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage Mounting dimensions and characteristics For reference only 2 Honeywell Sensing and Control

Models AC and JC Portable Pressure Calibrators Order Codes * = Example = Available on JC only SERIES JC* = 0.2% AC = 0.05% POWER W = Battery powered (9 V alkaline)* T = 110 Vac adapter (included) V = 11 Vdc to 32 Vdc (3 ft. cable) JC W 200 G PRESSURE RANGE (PSI) Standard 1=0-1 (opt) 200 = 0-200* 2K = 0-2000 5=0-5 (opt) 300 = 0-300 3K = 0-3000 15 =0-15 500 = 0-500 5K = 0-5000 30 = 0-30 750 = 0-750 7.5K= 0-7500 50 =0-50 1K = 0-1000 10K = 0-10000 100 =0-100 1.5K= 0-1500 REFERENCE G= Gage (std) reads zero at atmosphere * A= Absolute (opt) reads zero at vacuum (15 psi or higher) V= Vacuum (opt) scaled in In Hg (15 psi or lower) C= Compound (opt) reads both positive & negative (vacuum) pressure ELECTRICAL CONNECTION Z = No electrical connection (Model JCW - 9 volt battery)* C= 3 foot cable (Model JCV) T = ac adapter (Model JCT) O P T I O N A L Call factory for availability of other electrical connections and cable lengths. The following order codes are used ONLY if you want these options. OPTIONAL UNITS OF MEASURE (AC is Front Panel Field Selectable, JC is Factory Set) Ft H20 = Feet of water Bar = Bar In H20 = Inches of water mmhg =mm of mercury In Hg = Inches of mercury kpa = Kilopascals Consult factory for other units of measure not listed Note: PSI is standard NEMA 4 CONSTRUCTION 4 = NEMA 4 (not available on Model JCT or ACT) Z ( ) These order codes are used ONLY if you want special units of measure and/or NEMA 4 rating. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008687-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model LC Digital Force Indicator Model LC shown with optional handle. DESCRIPTION The Model LC digital force indicator is a highly portable force measurement device. With its 9 V battery supply and compact size the indicator can easily be carried to remote locations to perform force measurement calibrations. The unit can measure compression forces up to 50,000 lbs. The peak capture feature allows the highest force reading taken to be displayed with the push of a button. The remote location of the load sensor minimizes the chance of damage to the electronic body of the gauge. The stainless steel construction of the sensor and the indicator makes them often resistant to the occasional mishandling than can occur in the field. Optional handles are available for the load cell and gauge. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. FEATURES Ranges to 50000 lb Compression measurement High/low force capture Zero offset/tare NIST traceable Customer recalibration Optional handles and panel mounting ring Optional carrying case Optional NEMA 4 rating Selectable engineering units

Model LC PERFORMANCE SPECIFICATIONS Repeatability 0.2 % of full scale Range 5 lb to 50000 lb High and low capture Standard Update speed 3 per sec (selectable to 10 per sec) ELECTRICAL SPECIFICATIONS Power 9 V battery, 11 Vdc to 32 Vdc, 100 Vac MECHANICAL SPECIFICATIONS Diameter 93,98 mm [3.7 Display 4½ digits Case material Cell materials Zero/span adjustment Standard Low battery indication Standard Face membrane Tactile feedback Calibration data Stored on memory chip Mounting dimensions ADDITIONAL SPECIFICATIONS Pressure range (psi) 0 psi to 1 psi (opt) = 1 0.001 0 psi to 5 psi (opt) = 5 0.005 0 psi to 25 psi = 25 0.005 0 psi to 50 psi = 50 0.01 0 psi to 100 psi = 100 0.02 0 psi to 250 psi = 250 0.05 0 psi to 500 psi = 500 0.1 0 psi to 1000 psi = 1K 0.2 0 psi to 2000 psi = 2K 0.5 0 psi to 3000 psi = 3K 2 0 psi to 4000 psi = 4L 2 0 psi to 5000 psi = 5K 1 0 psi to 7500 psi = 7.5K 2 0 psi to 10000 psi = 10K 2 0 psi to 15000 psi = 15K 2 0 psi to 20000 psi = 20K 2 Incremental display steps 0 psi to 30000 psi = 30K Consult factory 0 psi to 50000 psi = 50K Consult factory ACCESSORIES ORDER CODES Order code Accessory CC2 Standard carrying case: 3 9/16 D x 7 13/16 W x 8 1/2 L MR2 NISTCERTS HD1 Panel mounting ring NIST certification (in addition to NIST statement) Handle 2 Honeywell Sensing and Control

Model LC NOTES 1. Accuracies stated are for best fit straight line for all errors including linearity, hysteresis and repeatability through zero. 2. Consult factory for optional units of measure. 3. Consult factory for optional electrical connectors and cable lengths. ORDER GUIDE SERIES LC=0.2% repeatability POWER W=Battery powered (9 V alkaline) T=110 Vac adapter (included) V=11 Vdc to 32 Vdc (3 ft.cable) PRESSURE RANGE (lb) standard 5=0-5 1K=0-1000 10K=0-10,000 10=0-10 2K=0-2000 15K=0-15,000 25=0-25 3K=0-3000 20K=0-20,000 50=0-50 4K=0-4000 30K=0-30,000 100=0-100 5K=0-5000 50K-0-50,000 250=0-250 7.5K=7500 500=0-500 REFERENCE K=Compression ELECTRICAL CONNECTION Z= No electrical connection C= 3 foot cable T = ac adapter Call factory for availability of other electrical connections and cable lengths. UNITS OF MEASURE (Field Selectable) Note: lbs is standard n = Newton Kn = Kilonewton g = Grams Kg = Kilograms Consult factory for other units of measure not listed OPTIONAL NEMA 4 CONSTRUCTION 4 = NEMA 4 LC W 100 K Z ( ) This order code is used ONLY if you want NEMA 4 rating. Digital Force Indicator Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008671-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.

Model LK Digital Force Indicator Model LK shown with optional handle. Visit our Web site for more information on optional handles. DESCRIPTION The Model LK Digital Force Indicator is a highly portable force measurement device. With its 9 V battery supply and compact size the indicator can easily be carried to remote locations to perform force measurement calibrations. The unit can measure forces in tension and compression over ranges up to 10000 lb. The peak capture feature allows the highest force reading taken to be displayed with the push of a button. The remote location of the load sensor minimizes the chance of damage to the electronic body of the gauge. The stainless steel construction of the sensor and the indicator also make them resistant to the occasional mishandling than can occur in the field. Optional handles are available for the load cell and gauge. Each unit has a membrane face with raised buttons and tactile feedback for setup and operation. The high, low, and clear buttons are easily accessible on this front membrane. Zero adjustment and zero offset/tare functions are standard on each unit. Calibration and setup parameters are stored on a memory chip to protect from loss even when power is interrupted. Unauthorized set ups and calibrations are also blocked with internal security. Various combinations of the front panel buttons can be de-activated. FEATURES Ranges to 10000 lb Tension and compression measurement High and low force capture Zero offset/tare NIST traceable Optional carrying case and panel mounting ring Optional NEMA 4 rating Field selectable engineering units (lb, N, kn, g, kg) Customer recalibration