Fire Retardant Resins PERFORMANCE THAT TAKES THE HEAT

Similar documents
Abrasion Resistance of Fluoropolymer and polyester Coatings

Three fire retardant soft PVC with excellent environmental performance, ready for industrial use

Generation, Assessment

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

Market-Leading Non-Metallic Enclosure Brands

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Overview of fire retardants solutions PIN Flame Retardants in PVC cables

Disaster Response Can Composites Prevent This? Construction, Corrosion, & Infrastructure Conference April

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

THERMAL & ACOUSTIC INSULATION FOR RAILWAY VEHICLES

Cablosam Tapes for Fire-Resistant Cables

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

FR Veil Provides Low Cost Model to Achieve ASTM E-84 Class A Smoke Index

Fire Performance of Translucent Systems

CHOOSING CORE MATERIALS FOR AEROSPACE APPLICATIONS

Appendix: Standards and Specifications for Evaluation of Thermal Management in Electronic Industry

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

ON FIRE OF QUALITY: SINCE 1972 A CONTINUUM

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Woven Polyester High. ACETex the proven choice for: n Embankment Support over piles. n Support over voids

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

BS 476: Part 6: 1989+A1:2009

FIRE TESTING SERVICES FIRE TESTING SER

Cotton Flammability Issues: An Update COTTON INCORPORATED MARY ANKENY

BS EN ISO : 2010

Product Data Sheet Trespa HPL Panels

Protective & Marine Coatings Europe, Middle East, Africa & India

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

Makrolon. Makrolon Sheet Products Guide. BG performance for bus glazing,

EU flammability standards and ENFIRO

AAA Chimney Corp dba 1 Hour Chimney

Plug in your cables with BLUESIL

Public Comment No. 1-NFPA [ Section No ]

Guide to interpreting Markings for Single Axis Fire Doors Hinges

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

ENGINEERING EVALUATION

IMO Resolution MSC 61(67): Annex 1: Part 2

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

Passive protection against hydrocarbon hazards

2.2 Factors in design

Wiring Duct Product Selection Guide

Review Fire Test Report

AVAILABILITY LIST (METRIC)

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Use of Flame Retardants to Comply with Fire Safety Requirements for Textiles. Marcelo M. Hirschler

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

PERFORMANCE POLYMER SOLUTIONS

BS EN ISO : 2010

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Identifying and Preventing Dust Fire and Explosion Hazards

Nuclear Power Plant LSZH Cable Overview

R-407A R-448A R-449A

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

The UK National Radon Action Plan From Directive to Publication

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

Geomembranes that work

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011

BS EN ISO : 2010

Standards in Security Shutters & Fire Shutters (UK & USA)

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

INTERNATIONAL STANDARD

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

Flame Retardant Polyethylene Tubing

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

BS 476: Part 6: 1989+A1:2009

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

Pneumatic Tubing POLYTUBING O.D. 5/32"

FUNDERMAX GMBH FIRE TEST REPORT

A JOURNEY OF COMBINING FIRE SAFETY AND DESIGN CRITERIA FOR ENGINEERING THERMOPLASTICS FOR RAILWAY INTERIORS

IFLA Regional Office for Latin America and the Caribbean: Call for Applications to host the Regional Office

BS EN : 2001 & IEC :2000

SIGMADEK, LTD. FIRE TEST REPORT

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Dow Wind Energy - Epoxy Systems Latin America Team

fire resistant cables

Geomembranes that work

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

FACADES AND FIRE The Essential Elements

Your partner for thermoplastic powders. Worldwide. Flame retardance

BUSINESS PLAN CEN/TC 79 RESPIRATORY PROTECTIVE DEVICES EXECUTIVE SUMMARY

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

The Importance of Flame Retardant. Jackson Liu, 3M Taiwan

A Look at General Cable s GenFree II Product Line

INTERNATIONAL STANDARD

CPS V Cabinet Power System

TUFFAK Sheet Products Guide

TUFFAK polycarbonate. A new generation of engineered sheet products for signage

Transcription:

Fire Retardant Resins PERFORMANCE THAT TAKES THE HEAT

AOC s resins combine the performance benefits of composite resins with fire retardant and smoke suppression technologies. resins meet flame, smoke and other performance requirements for specific enduse applications and fabrication methods including hand lay-up, spray-up, filament winding and pultrusion. Some products can also be used in closed mold processes such as Resin Transfer Molding (RTM) and Infusion. With superior strength, durability and flexibility, AOC fire-retardant resins outperform the competition. The information contained in this brochure is based on laboratory data, testing results, and field experience. AOC believes this information to be reliable, but does not guarantee the applicability of such information to the user s process or that the user will be able to replicate such results in their own process. Further, AOC assumes no liability for occurrences arising out of such information. The user, by accepting the products described herein, agrees to be solely responsible for thoroughly testing each such application before committing to production. The only operative warranties with respect to any of the products described herein shall be pursuant to AOC s standard terms and conditions associated with an executed invoice or purchase order pursuant to an executed purchase agreement.

PRODUCTS FIRE RETARDANT RESINS Halogen-Free Resin Chemistry Product Series Description Test Certifications Primary Markets Served K140 Designed for mass transportation and building applications Achieves Class A flame and smoke requirements Meets globally recognized transportation standards Exceeds US Docket 90 requirements Achieves HL2 rating by European Standard 45545 Lighter weight than products using ATH Improved handling and storage stability Bombardier SMP 800-C ISO 5660 ISO 5658 ISO 5659 Halogen-Free Requires Alumina Trihydrate (ATH) K320 High reactivity for improved cycle times in Light RTM applications Achieves Class B rating Renewable bio-derived versions available Bombardier SMP 800-C UL 94 Methacrylate Modified K133 Achieves Class A rating Exceptionally low smoke development Thixotropic versions available for improved ATH suspension Economical RoHS compliant versions BSS 7239 UL 94 ASTM E 1354 ASTM D 635 BS 6853 BS 476 Part 6&7 Bisphenol-A Vinyl Ester K010 Designed for Light RTM applications Tough and versatile resin with excellent crack resistance Thixotropic versions available for improved ATH suspension Bombardier SMP 800-C Summary Class I Flame Rating Class II Flame Rating Class I Smoke Rating Class A Class B 25 Flame Spread 26-75 Flame Spread 450 Smoke Development Class I Flame and Class I Smoke Class II Flame and Class I Smoke

FIRE RETARDANT TEST METHOD OVERVIEW Requirement Test Method Market Requirement Test Characteristic K140 K320 K133 K010 International Building Code Flame Spread and Smoke Development * British Standards BS 476 Part 6 and Part 7 Fire Propagation and Flame Spread * * * British Standards BS 6853 Annex B and Annex D Smoke Development and Smoke Toxicity * * * Federal Transit Administration Flame Spread Federal Transit Administration Smoke Development Bombardier Specification SMP 800 Toxic Gas Production Boeing Specification BSS 7239 Toxic Gas Generation * * * European Consolidated Standard EN45545 (ISO 5658-2, ISO 5659-2, ISO 5660-1) Flame Spread, Smoke Development, Toxic Gas, Heat Release * * * Underwriters Laboratory UL 94 Devices and Appliances Flammability Rating * * Miscellaneous ASTM D 635 Miscellaneous Rate of Burning * * * Miscellaneous ASTM E 1354 ISO 5660-1 Miscellaneous Oxygen Consumption Calorimeter * * *Not tested. Many products are able to meet other requirements in addition to the formal testing listed above. AOC chemists can customize a formula to meet specific needs and test requirements not listed. Please contact your AOC sales or technical service representative for more information about your project s unique needs. Testing: The degree of fire resistance of a cured resin is characterized by many different tests depending on the requirements for the end use application. These tests are performed under strictly controlled conditions by third party accredited testing facilities. How the results are reported vary depending on the test performed. Results from this testing can be assigned a rating based on a predefined scale and/or on a pass/fail criteria. The fire retardant performance of a composite cured under controlled conditions can vary significantly in an actual fire situation due to the large number of unpredictable variables associated with actual fire situations. The fire performance of a particular resin as determined by the conditions of a fire test is indicative of a fully-cured composite and is dependent on part thickness and glass content. AOC has additional information regarding post-cure and laminate construction that can be useful for assisting our customers in fabricating a composite part to meet the intended fire test requirements.

FIRE RETARDANT / CORROSION RESINS Contains Halogens Resin Chemistry Product Series Description Primary Markets Served Bisphenol-A Vinyl Ester K022 Can meet Class 1 flame spread requirements Versions containing Antimony Trioxide (ATO) are available for improved flame spread results Thixotropic versions available for improved sag resistance RoHS compliant versions Specialty Bisphenol-A Vinyl Ester K026 Can meet Class 1 flame spread requirements Thixotropic versions available for improved sag resistance Higher heat distortion temperature than standard Bisphenol-A Vinyl Esters Novolac Vinyl Ester K095 Can achieve Class 1 flame and smoke requirements Designed for elevated temperature service Isophthalic K733 Can meet Class 1 flame spread with and without ATO Thixotropic versions available for improved sag resistance Suitable for some mild chemical resistant applications K130 Most versatile fire retardant resin Can meet Class 1 flame requirements ATH filled versions available to achieve Class A rating RoHS compliant versions Chlorendic K190 Preferred resin for hot-wet chlorine and oxidizing chemicals Can meet ASTM Class B requirements

SALES CONTACTS AOC World Headquarters 955 Highway 57 East Collierville, TN 38017 + 01 901.854.2800 info@aoc-resins.com www.aoc-resins.com @aocresins AOC,, and are registered trademarks of AOC, LLC. 2017 AOC North America +01 866.319.8827 northamerica@aoc-resins.com Latin America +01 863.815.5016 latinamerica@aoc-resins.com Middle East middleeast@aoc-resins.com Europe europe@aoc-resins.com AOC UK Ltd. salesuk@aoc-resins.com India india@aoc-resins.com Asia/Australia asia@aoc-resins.com