Rosemount 2088 Absolute and Gage Pressure Transmitter

Similar documents
Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Rosemount 2090P Pulp and Paper Pressure Transmitter

Annubar Flowmeter Series

Rosemount 4500 Hygienic Pressure Transmitter

Sanitary Pressure Transmitter

Absolute and Gage Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 752 Fieldbus Remote Indicator

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2051T In-line Pressure Transmitter

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 3051S Series of Instrumentation

Rosemount 3051SFC Compact Orifice Flowmeter

Rosemount 3051S Series of Instrumentation

Rosemount 3051CFC Compact Flowmeter

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 3051L Level Transmitter

Rosemount 3051SFP Proplate Flowmeter

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 3051 Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter

Rosemount 3100 Series Ultrasonic Level Transmitters

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Rosemount 3051 Pressure Transmitter

Configuration Data Sheet

Rosemount 3051S MultiVariable Transmitter

Rosemount 3051 Pressure Transmitter

Rosemount 2051CF DP Flowmeters

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3051 Pressure Transmitter

Rosemount Integral Orifice Flowmeter Series

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA

Rosemount 3100 Series Ultrasonic Level Transmitters

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 3051CF DP Flowmeters

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol.

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount Compact Orifice Flowmeter Series

Rosemount 3490 Series

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter

Rosemount 3051S MultiVariable Extension Supplement

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 702 Wireless Discrete Transmitter

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 8800D Series Vortex Flowmeter

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Rosemount 1595 Conditioning Orifice Plate

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Rosemount 644 Temperature Transmitter

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 248 Temperature Transmitter

Rosemount 8800D Series Vortex Flowmeter

Rosemount 644H and 644R Smart Temperature Transmitters

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Rosemount 2100 Series

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Druck DPI 705/DPI 705 IS Series

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

ST 3000 Smart Transmitter Series 900 Extension Models. Specification and Model Selection Guide. Introduction 34-ST /04

Rosemount 3144P Temperature Transmitter with HART Protocol

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

High Pressure Conductivity Monitor

Rosemount 2120 Vibrating Fork Liquid Level Switch

OPTIBAR DP 7060 Supplementary Instructions

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Gas cylinder scale Model GCS-1

Enraf Servo Gauge 854 XTG

FAHM Co. Temperature Transmitter PTT74 Series

M7100 Pressure Transducer

Enraf Servo Gauge 854 ATG

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Rosemount 3144P Temperature Transmitter

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Rosemount 248 Temperature Transmitter

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Transcription:

Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Absolute and gage pressure ranges from 0 1.5 psi to 0 4,000 psi (0 0.1 to 0 276 bar) Performance of 0.075% with high accuracy option Rangeability of 20:1 Lightweight, compact design for cost effective installation Optional HART low power Contents Specifications.............................................. page Pressure-3 Product Certifications........................................ page Pressure-5 Dimensional Drawings........................................ page Pressure-8 Ordering Information......................................... page Pressure-9 www.rosemount.com

Rosemount 2088 Product Data Sheet Rosemount 2088 Gage and Absolute Transmitter The 2088 Pressure Transmitter is an economical addition to the pressure transmitter line of instruments. The 2088 is designed with reliability, long-term performance, and maintainability in mind. The 2088 maintain a specification conformance of at least 3 (1). The rugged, reliable performance for which Rosemount transmitters are famous, coupled with capabilities, make these transmitters exceptional values. The 2088 is available in either gauge or absolute pressure in pressure ranges to 4,000 psi (275 bar). It utilizes a solid-state, polysilicon pressure sensor with a choice of either 316L or Hastelloy C-276 isolating diaphragms. The low oil fill of this design has very little temperature effect and outstanding accuracy. (1) Sigma ( ) is a statistical symbol to designate the standard deviation from the mean value of normal distribution. Features The 2088 provides accurate, stable, and reliable pressure measurement in difficult applications. Its small compact design allows it to be directly connected to a process - providing a quick, easy, and cost effective installation. The 2088 standard process connection is 1 /2 inch NPT but a variety of optional connections are available. Optional connections range from multiple threaded connections to our full line of manifolds and remote diaphragm seals that provide solutions for virtually any connection. The 2088 also features an optional, fully configurable LCD that displays pressure and diagnostic information. The information displayed is directly from the microprocessor which accounts for its accuracy and reliability. Rosemount Pressure Solutions Rosemount 3051S Series of Instrumentation Scalable pressure, flow and level measurement solutions improve installation and maintenance practices. Rosemount 3095 Mass Flow Transmitter Accurately measures differential pressure, static pressure and process temperature to dynamically calculate fully compensated mass flow. Rosemount 305, 306 and 304 Manifolds Factory-assembled, calibrated and seal-tested transmitter-to-manifold assemblies reduce installation costs. Rosemount 1199 Diaphragm Seals Provides reliable, remote measurements of process pressure and protects the transmitter from hot, corrosive, or viscous fluids. Orifice Plate Primary Element Systems: Rosemount 1495 and 1595 Orifice Plates, 1496 Flange Unions and 1497 Meter Sections A comprehensive offering of orifice plates, flange unions and meter sections that are easy to specify and order. The 1595 Conditioning Orifice provides superior performance in tight fit applications. Annubar Flowmeter Series: Rosemount 3051SFA ProBar, 3095MFA Mass ProBar, and 485 The state-of-the-art, fifth generation Rosemount 485 Annubar combined with the 3051S or 3095 MultiVariable transmitter creates an accurate, repeatable and dependable insertion-type flowmeter. Compact Orifice Flowmeter Series: Rosemount 3051SFC, 3095MFC, and 405 Compact Orifice Flowmeters can be installed between existing flanges, up to a Class 600 (PN100) rating. In tight fit applications, a conditioning orifice plate version is available, requiring only two diameters of straight run upstream and two downstream. ProPlate Flowmeter Series: Rosemount 3051SFP ProPlate, 3095MFP Mass ProPlate, and 1195 These integral orifice flowmeters eliminate the inaccuracies that become more pronounced in small orifice line installations. The completely assembled, ready to install flowmeters reduce cost and simplify installation. Pressure-2

Product Data Sheet Rosemount 2088 Specifications Performance Specifications (Zero-based spans, reference conditions, silicone oil fill, and 316L SST isolating diaphragm.) Reference Accuracy ±0.10% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability ±0.075% of calibrated span (high accuracy option) Ambient Temperature Effect Expressed as a total effect per 50 F (28 C) Total effect includes zero and span effects. ± (0.15% URL + 0.15% of span) from 40 F to 185 F (-40 C to 85 C) Stability ±0.10% of URL for 12 months Vibration Effect Less than ±0.1% of URL when subjected to vibration of: peak to peak constant displacement of 4 mm (5 15 Hz) and constant acceleration of 2 g (15 150 Hz) and 1 g (150 2000 Hz). Ranges Range Minimum Span URL/Max. span/ Sensor Limit 1 1.5 psi (103 mbar) 30 psi (2,1 bar) 2 7.5 psi (517 mbar) 150 psi (10,3 bar) 3 40 psi (2,8 bar) 800 psi (55,2 bar) 4 200 psi (13,8 bar) 4000 psi (275,8 bar) Output Code S: 4 20 ma dc Code N: 1-5 volt dc, low power (Outputs are directly proportional to the input pressure) Rangedown 20 to 1 Load Limitations Reverse polarity protection is standard. Maximum loop resistance is determined by the power supply voltage as described by the following equations: Max. Loop Resistance = 43.5 (Power Supply Voltage 10.5) Power Supply Effect Less than 0.01% of calibrated span per volt Mounting Position Effect Zero shift of up to 1.2 inh 2 O (0.30 kpa), which can be calibrated out. No span effect. Load (ohms) Operating Region RFI Effect Less than ±0.25% of upper range limit from 20 1000 MHz at 30 V/m with leads in conduit. Less than ±0.25% of upper range limit from 20-1000 MHz at 10 V/m with unshielded twisted pair (no conduit). Transient Protection Limits IEEE 587 Category B 6 kv Crest (1.2 50 s) 3 ka Crest (8 20 s) 6 kv Crest (0.5 s by 100 khz) IEEE 472 SWC 2.5 kv Crest,1 MHz waveform General Specifications Tested to IEC 801-3 Functional Specifications Service Liquid, gas, and vapor applications Power Supply Output Code S (dc Volts) Communication requires a minimum loop resistance of 250 ohms. (1) For hazardous location approvals, power supply must not exceed 36 V. (2) For CENELEC Ex ia approval, the power supply must not exceed 30 V. Power Supply External power supply required. Transmitter operates on 10.5 36 V dc with no load (6 12V for Low Power). Reverse polarity protection is standard. Current Draw Output Code N: 3 ma without LCD display. Overpressure Limits Range 1: 120 psig max All other ranges: two times the URL Burst Pressure 11,000 psi for all ranges Pressure-3

Rosemount 2088 Product Data Sheet Zero Elevation and Suppression Zero can be suppressed between atmosphere for gage transmitters or 0 psia for absolute transmitters and upper range limit, provided the calibrated span is equal to or greater than the minimum span, and the upper range value does not exceed the upper range limit. Time Response Time Constant: 200 milliseconds Dead time: < 0.1 s Update rate: 20 times per second minimum Temperature Limits Process Silicone fill sensor: 40 to 250 F ( 40 to 121 C) Inert fill sensor: 22 to 250 F ( 30 to 121 C) Process temperatures above 185 F (85 C) require derating the ambient limits by a 1.5:1 ratio: Ambient: 40 to 185 F ( 40 to 85 C) 4 to 175 F ( 20 to 80 C) with LCD display (1) (1) LCD display may not be readalbe and LCD updates will be slower at temperatures below -4 F (-20 C). Storage: 50 to 230 F ( 46 to 110 C) 40 to 185 F ( 40 to 85 C) with LCD display Maximum Ambient = Temperature in F Maximum Ambient = Temperature in C Humidity Limits 0 100% relative humidity Volumetric Displacement Less than 0.00042 cm 3 Turn-on Time 2.0 seconds, no warm-up required Transmitter Security ( Process Temp 185) 185 ---------------------------------------------------------- 1.5 85 ( Process Temp 85) ------------------------------------------------------- 1.5 Activating the transmitter security function prevents changes to the transmitter configuration, including local zero and span adjustments. Security is activated by an internal switch. Failure Mode If self-diagnostics detect a sensor or microprocessor failure, the analog signal is driven either high or low to alert the user. High or low failure mode is user-selectable with a jumper on the transmitter. The values to which the transmitter drives its output in failure mode depend on whether it is factory-configured to standard or NAMUR-compliant operation. The values for each are as follows: Standard Operation Output Code Linear Output Fail High Fail Low S 3.9 I 20.8 I 21.75 ma I 3.75 ma N 0.97 V 5.2 V 5.4 V V 0.95V N with Code C2 0.78 V 3.44 V 4.0 V V 0.77 V NAMUR-Compliant Operation Linear Output Fail High Fail Low Output Code S 3.8 I 20.5 I 22.5 ma I 3.6 ma Physical Specifications Electrical Connection 1 /2 14 NPT, M20 1.5 (CM20), PG 13.5, or G 1 /2 female (PF 1 /2 female) conduit entry Process Connection 1 /2 14 NPT female, DIN 16288 G 1 /2 male, RC 1 /2 female (PT 1 /2 female), M20 1.5 (CM20) male Process Wetted Parts Isolating Diaphragm 316L stainless steel or Hastelloy C-276 Process Connector 316L stainless steel CF-3M (Cast version of 316L SST, material per ASTM_A743) or Hastelloy C-276 Non-wetted Parts Electronics Housing Low-copper aluminum, NEMA 4X, IP65, IP67,CSA enclosure Type 4X Paint Polyurethane Cover O-rings Buna-N Fill Fluid Silicone or inert fill Weight Output Code S and N: Approximately 2.44 lb (1.11 kg) Tagging The transmitter is tagged, at no charge, in accordance with customer requirements. All tags are stainless steel. The standard tag is permanently attached to the transmitter. Tag character height is 1 /8 in. (0.318 cm). A wired tag is available upon request. Accessory Block and Bleed Valve (S5 Option) The Rosemount 306 Integral Manifold is pre-assembled to transmitter and leak checked. Pressure-4

Product Data Sheet Rosemount 2088 Product Certifications Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota, USA Emerson Process Management GmbH & Co. Wessling, Germany Emerson Process Management Asia Pacific Private Limited Singapore Beijing Rosemount Far East Instrument Co., LTD Beijing, China European Union Directive Information The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting our local sales office. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) 2088/2090 Pressure Transmitters Sound Engineering Practice Electro Magnetic Compatibility (EMC) (2004/108/EC) All 2088/2090 Pressure Transmitter: EN 61326-1:1997 with Amendments A1, A2, and A3 Canadian Standards Association (CSA) C6 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for Class II, Division 1, Groups E, F, G, Class III, indoor and outdoor hazardous locations. CSA enclosure Type 4X; factory sealed. Suitable for Class I, Division 2, Groups A, B, C, and D. Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. Temp. Code T3C. Intrinsically safe when connected with approved barriers in accordance with Rosemount drawing 02088-1024. For input parameters see control drawing 02088-1024. European Certifications I1 ATEX Intrinsically Safe Certificate No.: BAS00ATEX1166X EEx ia IIC T5 (T amb = 55 to 40 C) EEx ia IIC T4 (T amb = 55 to 70 C) 1180 TABLE 1. Input Parameters Loop/Power U i = 30 V dc I i = 200 ma P i = 0.9 W C i = 0.012 F II 1 G Input Type Hazardous Locations Certifications North American Certifications Ordinary Location Certification for Factory Mutual As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Factory Mutual (FM) Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for Class II, Division 1, Groups E, F, G, Class III, Division 1, indoor and outdoor (Type 4X) hazardous locations; factory sealed. I5 Intrinsically safe for use in Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, and G; and Class III, Division 1 when connected in accordance with Rosemount drawing 02088-1018. Non-incendive for Class I, Division 2, Groups A, B, C, and D. For input parameters see control drawing 02088-1018. N1 Special Conditions For Safe Use (x): When the optional transient protection terminal block is installed, the apparatus is not capable of withstanding a 500V rms test to case. This must be taken into account on any installation in which it is used, for example by assuring that the supply to the apparatus is galvanically isolated. ATEX Type n Certification No.: BAS00ATEX3167X EEx nl IIC T5 (T a = -40 C to 70 C) U i = 50 V dc max II 3 G Special Conditions For Safe Use (x): When the optional transient protection terminal block is installed, the apparatus is not capable of withstanding a 500 V r.m.s. test to case. This must be taken into account on any installation in which it is used, for example, by assuring that the supply to the apparatus is galvanically isolated. Pressure-5

Rosemount 2088 Product Data Sheet ND ED ATEX Combustible Dust Certificate No.: BAS01ATEX1427X II 1 D T105 C (T amb = -20 C to 85 C) IP66 1180 Vmax = 36 V dc Max I i = 24 ma Special Conditions For Safe Use (x): 1. The user must ensure that the maximum rated voltage and current (36 volts, 24 ma, D.C.) are not exceeded. All connections to other apparatus or associated apparatus shall have control over this voltage and current equivalent to a category ib circuit according to EN50020. 2. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP66. 3. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7J impact test. 5. The 2088/2090 sensor module must be securely screwed in place to maintain the ingress protection of the enclosure. ATEX Flameproof Certification No.: KEMA97ATEX2378 II 1/2 G EEx d IIC T6 (T a = -40 C to 40 C) T4 (T a = -40 C to 80 C) 1180 Vmax = 36 (with output option) Vmax = 14 (with low power output option) Japanese Certifications E4 TIIS Flameproof Ex d IIC T6 (T amb = 85 C) Certificate Description TC15879 2088 with SST wetted parts (with display) TC15877 2088 with Hast wetted parts (with display) TC15876 2088 with Hast wetted parts (no display) TC15875 2088 with SST wetted parts (no display) TC15874 2088 with Hast wetted parts (with display) TC15873 2088 with Hast wetted parts (no display) TC15872 2088 with SST wetted parts (with display) TC15871 2088 with SST wetted parts (no display) Australian Certifications I7 N7 E7 NK SAA Intrinsic Safety Certification No.: AUS Ex 1249X Ex ia IIC T4 (T amb = 70 C) Ex ia IIC T5 (T amb = 40 C) IP66 When connected per Rosemount drawing 03031-1026 TABLE 2. Input Parameters Loop/Power U max = 30 V I max = 200 ma I max = 160 ma (Ouput Code A with T1) P max = 0.9 W P max = 1.3 W (Fieldbus/Profibus) C i = 0.01 F C i = 0.042 F (Output Code M) L i = 10 H L i = 1.05 H (Output Code A with T1) L i = 0.75 H (Output Code M) Input Type Special Conditions For Safe Use (X): Observe barrier/entity parameters during installation. A passive current limited power source must be used. The power source must be such that Po (Uo * Io)/4. For modules using transient protection in the terminal assembly (T1 transient protection models), the apparatus enclosure is to be electrically bonded to the protective earth. The conductor used for the connection shall be equivalent to a copper conductor of 4mm 2 minimum cross-sectional area. SAA Type n (Non-Sparking) Certificate No.: AUS Ex 1249X Ex n IIC T4 (T amb = 70 C) Ex n IIC T5 (T amb = 40 C) IP66 Special Conditions For Safe Use (X): Where the equipment is installed such that there is an unused conduit entry, it must be sealed with a suitable blanking plug to maintain the IP66 degree of protection. Any blanking plug used with the equipment shall be of a type which requires the use of a tool to effect its removal. Voltage source shall not exceed 60V ac or 75V dc. IECEx Flameproof (Explosion-Proof) IECEx Certificate number: IECEx KEM 06.0021X Ex d IIC T6(T amb = -20 C to 40 C) Ex d IIC T4(T amb = -20 C to 80 C) Vmax = 55Vdc Ii = 23mA IECEx Dust Ignition Proof IECEx Certificate number: IECEx KEM 06.0021X Ex td A22 IP66 T90 C(T amb = -20 C to 80 C) Vmax = 55Vdc Ii = 23mA Pressure-6

Product Data Sheet Rosemount 2088 Special Conditions For Safe Use (x): 1. The device contains a thin wall diaphragm. Installation, maintenance, and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime. 2. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP 66. 3. Unused cable entries must be used which maintain the ingress protection of the enclosure to at least IP 66. 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7J impact. 5. The 2088/2090 sensor module must be securely screwed in place to maintain the ingress protection of the enclosure Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types. KB KH K5 K6 K7 K1 Combination of K5 and C6 Combination of K5, I1, and ED Combination of E5 and I5 Combination of C6, I1, and ED Combination of I7, N7, E7, and NK Combination of I1, N1, ED, and ND Pressure-7

Rosemount 2088 Product Data Sheet Dimensional Drawings Rosemount 2088 0.75 (20) Clearance for Cover Removal 5.0 (127) 4.3 (110) Max. Optional Display Cover 3.9 (99) Certifications Tag 2 ½ 14 NPT Conduit Connection Terminal Connections Transmitter Circuitry 4.7 (120) 5.75 (146) Typical 2 ¼ 20 UNC-2B Mounting Holes M20 1.5 Female (CM20), PG 13.5, and G 1 /2 Female (PF 1 /2 Female) also available as options. ½ 14 NPT Female Process Connection (See Ordering Table for other options.) Mounting Configurations with Optional Mounting Brackets Pipe Mounting Panel Mounting 3.9 (99) 5.0 (127) 4.3 (110) 4.0 (102) 5.3 (135) 3.8 (97) 2.8 (71) 6.2 (157) 3.1 (78) 6.3 (159) 3.0 (80) 2-inch U-Bolt for pipe mounting (clamp shown) 4.8 (122) 7.0 (178) 1 /4 1 1 /4 Bolts for transmitter mounting (not supplied) 1.3 (33) 2.8 (71) 5 /16 1½ Bolts for panel mounting (not supplied) 1 /4 1 1 /4 Bolts for transmitter mounting (not supplied) 1.3 (33) Dimensions are in inches (millimeters). Pressure-8

Product Data Sheet Rosemount 2088 Ordering Information Model Product description 2088 Pressure Transmitter Code Transmitter type A Absolute G Gage Code Range Minimum span URL/Max.span 1 0 30 psi (0 2,1 bar) 1.5 psi (103,0 mbar) 30 psi (2,1 bar) 2 0 150 psi (0 10,3 bar) 7.5 psi (517,0 mbar) 150 psi (10,3 bar) 3 0 800 psi (0 55,2 bar) 40 psi (2,8 bar) 800 psi (55,2 bar) 4 0 4,000 psi (0 275,8 bar) 200 psi (13,8 bar) 4000 psi (275,8 bar) Code Output S 4 20 ma dc/digital HART Protocol N 1-5 V dc Low Power/ Digital HART protocol Materials of Construction Code Process connection Isolating diaphragm Oil fill 22 (1) 316L SST 316L SST Silicone 33 (1) Hastelloy C-276 Hastelloy C-276 Silicone 2B (1)(2) 316L SST 316L SST Inert Code Process connection A ½ 14 NPT Female B (2) DIN 16288 G ½ Male C (3) RC ½ Female (PT ½ Female) D (3) M20 1.5 Male (CM20 Male) Code Conduit thread 1 ½ 14 NPT 2 (2) M20 1.5 Female (CM20) 3 (4) PG 13.5 4 (4) G ½ Female (PF ½ Female) Code Options Integral manifold S5 (5)(6) Assemble to Rosemount 306 integral manifold Diaphragm seal assemblies S1 (6) Assemble to one Rosemount 1199 diaphragm seal Mounting brackets B4 SST mounting bracket with SST Bolts Special configuration (software) C4 (4) NAMUR alarm and saturation levels, high alarm CN (4) NAMUR alarm and saturation levels, low alarm C9 (7) Software configuration (Requires completed Configuration Data Sheet) Special configuration (hardware) C2 0.8-3.2 V dc output with HART protocol, Output code N only. Pressure-9

Rosemount 2088 Product Data Sheet Product Certifications I1 ATEX Intrinsic Safety N1 (4) ATEX Type n ND (4) ATEX Dust ED ATEX Flameproof C6 CSA Explosion-Proof, Intrinsically Safe, and non-incendive K6 (4) CSA Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (4) (8) E4 TIIS Flameproof E5 FM Explosion-Proof, Dust Ignition-proof E7 IECEx Flameproof I5 FM Intrinsically safe, Division 2 K5 FM Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2 KB FM and CSA Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2 KH (4) FM Approvals and ATEX Explosion-Proof and Intrinsically Safe I7 SAA Intrinsic Safety N7 SAA Type n NK IECEx Dust K7 SAA Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n K1 ATEX Flameproof, Intrinsic Safety, Type n, Dust Water Approval DW (9) NSF drinking water approval Display M5 LCD display, scaled 0 100% M7 LCD display, special configuration Special procedures P1 Hydrostatic testing P2 Cleaning for special service P8 (10) 0.075% accuracy to 10:1 turndown Special certifications Q4 Calibration certificate Q8 Material Traceability Certification per EN 10204 3.1B Q16 Surface finish certification for sanitary remote seals Toolkit Total System Performance Reports QZ Remote Seal System Performance Calculation Report Terminal blocks T1 Transient protection (Available with Option codes E5, ED, I1, I5, N1, C6, and K5) Typical Model Number: 2088 G 2 S 22 A 1 B4 M5 (1) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. (2) Not available with Range 4 or process connection code D. (3) Not available with Hastelloy C-276, Materials of Construction code 33 and low power output code N. (4) Not available with low-power Output code N. (5) Use 1 /2-14 NPT Female Process Connection code A. (6) Assemble-to items are specified separately and require a completed model number. (7) A Configuration Data Sheet, see document number 00806-0100-4690, must be completed. (8) Available with Conduit Thread code 4 and with or without Digital Display codes M5 and M7. (9) Requires Materials of Construction code 22 with Process Connection code A. (10) Available with Output code S, stainless steel isolators, and silicone fill. 00806-0100-4690 English R Pressure-10

Product Data Sheet Rosemount 2088 Pressure-11

Rosemount 2088 Product Data Sheet Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount, the Rosemount logotype, Annubar, ProPlate and Mass ProPlate are registered trademarks of Rosemount Inc. HART is a registered trademark of the HART Communications Foundation. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. All other marks are the property of their respective owners. Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1 800 999 9307 T (International) (952) 906 8888 F (952) 949 7001 www.rosemount.com 00813-0100-4690* 2008 Rosemount Inc. All rights reserved. Emerson Process Management Heath Place Bognor Regis West Sussex PO22 9SH England T 44 (0) 1243 863121 F 44 (0) 1243 867554 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.EmersonProcess.com