Use of Electric Downhole Heaters to Prevent Wax Build-up, Offshore, West Africa by Alistair Hill and Rick Newell, Pentair Thermal Management

Similar documents
Tyco Thermal Controls. Oil Field Services. Providing Thermal Technologies to meet your Upstream Flow Assurance Needs Tyco Thermal Controls

Tyco Thermal Controls. Heat Management Solutions for Upstream Sector. Valentin ILIE Tyco Thermal Controls

John M. Karanikas Chief Technology Officer Salamander Solutions. Downhole Heating A New and Robust Re-Creation of a Proven Technology

FIBER-OPTIC SENSING TECHNOLOGIES

The Roxar Downhole product portfolio Permanent downhole monitoring system

Artificial Lift. Integrated lifting solutions for enhanced well production

Solving challenges. Artificial Lift Enhancing the Halliburton Product Line

PowerReach Service: Hybrid Coiled Tubing & Jointed Pipe Technology. Fraser McNeil

Novel Coiled Tubing Perforation Approach Avoids Overflushing in Multistage Hydraulic Fracturing Operations in a Horizontal Well

Longline Heating. Contents. Introduction

Flooding Detection System for Flexible Annulus Integrity Monitoring

FIBER-OPTIC SYSTEM FOR MONITORING EXTENDED OBJECTS «FOSM»

Leak Detection. Ron Threlfall Manager, Leak Detection, Maintenance and Integration

INDUSTRIAL HEAT TRACING SOLUTIONS. Products & Services

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Technology, expertise, quality, and service. Slickline. Measurement and activation services

Figure 6- Capillary Installation

Optical Fiber Sensors for Permanent Downwell Monitoring Applications in the Oil and Gas Industry

INDUSTRIAL HEAT TRACING SOLUTIONS PRODUCTS & SERVICES

ADVANCED INDUSTRIAL SOLUTIONS HEAT-TRACING PRODUCTS & SERVICES

Installation of Downhole Heaters to Prevent Paraffin Blockages

CORPORATE PROFILE. Contents 1 Introduction 2 Products and Services 3 Contact Us 10

Downhole video technology

Roxar Flow Measurement Topside Flow Assurance Solutions. Søren Forné, Sales Manager Scandinavia

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

Kinetics Controls & Innovation Ltd RIGLESS WELL INTEGRITY & INTERVENTION ISOLATIONS. kciltd.co.uk

Cased Hole Division. Jimmy Mathis Cased Hole Manager Youngsville, LA. District

Darchem Thermal Protection

Tubular Industrial Process

Freezer Frost Heave Prevention

Daylight Energy Ltd. Well Blowout W5M March 4, 2011

Distributed Temperature Sensing. On Demand. OPTICall. Thermal Profile and Investigation Service

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Zenith E-Series ESP gauges

In-Situ Fluid Analysis in the North Sea

ALL PROTECTION SERVICES

Factory and Field Installed Splices

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Technology Overview of Distributed Pressure and Temperature Sensing with Fiber Bragg Grating Technology

ClampOn DSP Corrosion- Erosion Monitor

TECHNICAL PUBLICATION

Strip/Clamp-On Heaters

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

Fluid Delivery Heaters

6 th Pipeline Technology Conference 2011

Fluid Delivery Heaters

Integrated Cased-Hole Services. Maximum Well Performance

Tubular Industrial Process

A NEW LINE IN INTERVENTION

Integrated Well Abandonment

System Level Design Review. P16420: Lip Balm and Hand Salve Process Improvement

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

Industry Best 10 Year Commercial Warranty

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Mineral Insulated Band Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Asset Integrity Monitoring

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

High Performance Heater with More Efficient Heat

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

DOWNHOLE SOLUTIONS. MOTION CONTROL SOluTIONS TAILORED TO YOUR CRITICAL DOWNHOLE APPLICATIONS WHAT MOVES YOUR WORLD. Rev.

Use of Pressure Transient Analysis to Evaluate the Impact of Salt Deposition in Gas Wells. E.H. Smith

HEATERS MOUNTED ON THREADED PLUG

Gas Value Chain Solutions. Randy Miller

CASED HOLE SERVICES

Installation and Maintenance Manual Please retain this manual for future reference.

ICOTA Roundtable Retrievable Temperature Logging using DTS. October 20, 2011

FX5 Series Explosion-Proof Electric Air Heaters

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Use Metal Bellows To Replace Springs Benefits of Precision Metal Bellows as Spring Replacements in Mechanical and Electrical Applications

ReAct. Completion Technology Ltd. Remotely Activated Technology. omega-completion.com

Wellbore Diagnostics & Evaluation Using Fiber-Optic Enabled Coiled Tubing. Leak Detection & Production Logging Case Studies

Oil Field Services. Ground-breaking fibre-optic Distributed Acoustic Sensing (DAS) technology

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

Heat traced pipe-in-pipe for S or J-lay proof of concept test results

"ER" Series Electric Humidifier

Offshore Fiber-Optic Connectors from Topside to Downhole

Mineral Insulated Band Heater

Mapping the orientation of downhole sensing cables and control lines using an engineered hybrid distributed acoustic sensing system

OIL & GAS EXPERTS PRESSURE RELIEF & PRESSURE ACTIVATION WE ARE THE RIGHT SOLUTION

The water heater evolved. Hot water. Perfected.

RELAY. Digital Slickline System INTELLIGENT SLICKLINE CONVEYANCE FOR WELL INTERVENTION

DYNALINK TELEMETRY SYSTEM Reliable, real-time, wireless downhole communication

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

Evolution of Steam Sub-metering at Penn State University

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

LMR Electric Fire Pump Controllers Features

2018 Year 11 Physics Week 8. Thermal Energy Transfer

Coe Press Equipment Corporation. Power Straighteners. Coe Press Equipment Corporation. The Company That Feeds an Industry

Advancing Pipeline Safety

SLICK-E-LINE COMBINING MECHANICAL SLICKLINE CAPABILITY WITH REAL TIME LOGGING ONE CREW. ONE LINE. ONE RIG-UP.

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

FREEZE CASE HISTORY. 3-½ Tailpipe 7" packer 5-¾ open hole Lateral = 1500 ft

Transcription:

Use of Electric Downhole Heaters to Prevent Wax Build-up, Offshore, West Africa by Alistair Hill and Rick Newell, Pentair Thermal Management

AGENDA Issue - ensure a fluid temperature throughout the identified well-bore length that is above the expected wax appearance temperature Solutions which Electric Downhole Product is best suited to application What has been achieved

Programme First Steps Pentair Thermal Management was contracted in June of 2006 to perform a Feasibility Study on the Down Hole Heating System for a proposed Development Field, located off the West African coastline. The intent of the feasibility study was to provide a technical and economically viable solution to the unique heating needs of these offshore wells. The first step in this study was to properly evaluate the well-stream and wellbore conditions, specifically to define the heat-input requirement for the length of the production tube. This process included the analysis of several well-bore geometries; gas-liquid ratios; fluid/gas temperatures, differing flow rates, and other well-stream specific criteria pertinent to the thermal-hydraulic modelling needs for these wells.

Programme Requirement The engineering study was needed to conclude the following: What is the target WHT under normal production? What is the target temperature for well start-up? Heat input required versus well conditions (P, T, GOR, water cut, gross liquid rate) Which heater technology is appropriate? What is the reduction in WHT for each option? Electrical sizing of topsides equipment (based on development concept). How does this differ between options? Schedule and cost estimate for equipment and installation services

Field Conditions Waxy Crude WAT of +40 C, API of 33 Fractured Reservoir with multiple wells Expected variable GOR over life of wells leading to variable flow rates Expected variable Water Cut over life of wells leading to variable flow rates Wax re-melt facility after shut-in

Solution/ Modelling Wellbore Model to Client Data Comparison Client Data Matching Accuracy - to confirm the accuracy of the modelling software by using client Test data Definition of Investigation Matrix ; to prepare lifetime scenarios max flow for early well, intermediate flow for mature well, low flow for late well Cases Without Down Hole Heating Cases With Down Hole Heating Cool-down & Heat-up

Technology Discussion Once the thermal-hydraulic modelling had been completed, the evaluation of the correct heating method could then be investigated. Mechanical - Scraping/ Pigging Lost production due to intervention Frequency Infrastructure costs & labour costs Chemical Cost Infrastructure costs Recovery Back-up

ELECTRIC DOWNHOLE HEATING ENHANCED OIL RECOVERY (EOR) Definition Increase the amount of hydrocarbon entering the production tube by adding heat to the formation Application Heavy Oil production Enhanced Oil Recovery (EOR) FLOW ASSURANCE Definition Getting the hydrocarbons from the reservoir to the wellhead Application Prevent Wax/Paraffin & Hydrate Reduce Viscosity from reservoir to well head (Heavy Oil) Flow Assurance

PetroTrace Down Hole Heater Cables PetroTrace DHSX Series resistance cables Our DHSX downhole heater provides Flow Assurance heating to 3300ft (1km) TD, in applications where lower power levels are sufficient. 50 degc max 30kW to 45kW typical PetroTrace MI cables The downhole version of our MI cables are made to withstand the wellbore environment for EOR and Flow Assurance applications. Standard designs can provide very high power output over lengths up to 4000ft (1.2km), reaching to 8000ft (2.4km) TD or more. 482 degc max 20kW to 300kW typical Coiled Tube Skin effect Systems (STSi) For downhole use, we provide our STS heater in coiled tube form. This heater is well suited for Flow Assurance applications requiring moderately high power, for depths up to 6900ft (2.1km) TD. 150 degc max 100kW to 400kW typical

Conclusion Of the three Pentair technologies currently available for this type of application DHSX, MI and STS modelling shows that the MI Cable is the best overall solution for this service. The MI Cable can provide the required watt-density and can be manufactured to the lengths required. Most importantly, the MI Cable can meet the requirements of the most extreme the well conditions in the Field. The DHSX or STS technologies may still be used on select wells where conditions are applicable; but if only one technology were to be deployed throughout the Field to meet the most extreme cases, then the MI technology would be the right answer.

Downhole Heating System Offshore West Africa 600V 3-Phase with Wye Splice P/N#: PTM-3P-3278-10 Revision: 2 - Change to 3278 feet, 600 Volts Each heater supplied on a wooden Reel Part No. RL 78 x 36 Cold Leads factory terminated with 3/4" brass pot and 3/4" stainless steel gland 10 Feet (3.0 M) #2 AWG MI Cold Lead Cable Ref. 496-2/CU825 Diameter: 0.496" (12.6mm) Weight/Heater: 1930 Lb. 875 Kg TIG Welded Hot/Cold Splice (Typ. 3) Reel Weight: Estimated 456 Lb. 207 Kg Approx. Diam.: 1.1" (28mm) with strain relief cones Shipping 2386 Lb. 1082 Kg Weight/Htr: Pipe Section No. Watts/FT (Watts/M) Watts per Hot Section 3278 Feet (999.4 M) Long Cable Ref. 319-8/CU825 Diameter: 0.319" (8.1mm) of Pipe Section Cold Lead Hot Section 10.5 (34) 43.4 (142) 105 142,200 TIG Welded Hot/Hot Splice (Typ. 6) with strain relief cones Approx. Diam.: 1.0" (25.4mm) (Splices may not be at same location on each leg) Running Current (Amps) in oil at avg. 127 F (52.8 C) Startup Current (Amps) at 68 F (20 C) 136.7 160.3 - All heating and cold lead cables are 1/c Alloy 825 sheath. - There will be at least as many Tig Welded Wye Splice Hot/Hot splices as shown. Approx. diam.: 1.50" (38.1mm) - All splices TIG welded with Alloy 825 components. - Location of joints to be staggered at least 1 foot (300mm) apart.

Power and Control Four separate platforms Each with: Distribution board Master control panel Thyristor Controlled Power Cabinets Thyristor Control used as electronic contactor (on/off control) with coarse power control via manual autotransformer taps. Local control via independent PLC with integration into remote DCS on FPSO for remote operation

Fully automated multi-well control system 31 thyristor cabinets distributed across four platforms (3x 8, 1x 7). Each platform has its own DCS/PLC system for independent and local platform control. Remote information for all platforms available on field FPSO using subsea fibre optic communications network. Thyristor cabinet suite for multi well fully automated control system

MI Heater Installation Wye Splice Protector

Cable Clamps & Protectors Centralizing Clamp Wye splice protector

Heater-Tubing Separation (cable sag ) effect Cable sags away from tubing Clamping heater to tubing improves heat into tubing

MI Heater Installation Mandrel Based Penetrator Individual Penetrator System

What has been achieved A number of heaters have been deployed and operational since 2010. Oil production rates have greatly increased on wells with DHH deployed compared to those that haven t. wells which did not have DHH, wireline intervention could not pass beyond the mud line whereas those which did have DHH installed were as clean as a whistle Full evaluation is on-going as field performance has been affected by other operational issues but the wellbore heating is doing exactly what it was designed to do Some heaters were inactive for 10 months but were restarted without problem allowing production to re-commence.

Thank You!