NERC PRC Compliance Guide

Similar documents
Eagle Eye Battery Monitoring Solutions BMS-Series

4. Applicability: 4.1. Functional Entities: 4.2. Facilities: 5. Effective Date: See Implementation Plan

Standard PRC Protection System and Automatic Reclosing Maintenance. Standard Development Roadmap

4. Applicability: 4.1. Functional Entities: 4.2. Facilities: 5. Effective Date: See Implementation Plan

Standard Development Roadmap

4. Applicability: 4.1. Functional Entities: 4.2. Facilities:

Standard PRC-005-3(i) Protection System and Automatic Reclosing Maintenance

Standard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

June 4, 2014 VIA ELECTRONIC FILING. Ms. Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, D.C.

Standard PRC-005-3(X) Protection System and Automatic Reclosing Maintenance

Standard PRC-005-4(X) Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

Standard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

Standard PRC-005-X Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

PRC NERC Protection System Maintenance Standard PRC-005-2

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

Specification for On-Line UPS Battery Monitoring and Data Management System

Alarm Indication Philosophy and Implementation in Cellwatch

Loadstar AC/DC Systems

A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Spectron LSN (Life Safety Network) Suggested Specifications

A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing

Batt-Safe Battery String Monitoring System

A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing

EMEX 110 and EMEL. EMEX 110 and EMEL. 110, 50 and 24 volt AC/DC Central Battery Systems. EMEX 110 and EMEL

A77 Series. Microprocessor Controlled SCR Filtered/Battery Eliminator Filtered Charger. Installation and Operation Manual

Installer Certification Expiration. Terms

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Supplementary Reference and FAQ - Draft

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

Dale Power Solutions Ltd

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Agenda Technical Committee on Testing and Maintenance of Fire Alarm and Signaling Systems June 23-24, 2014 La Jolla, CA

Electrolyte Monitoring Sensor

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Appendix B. FRCC regional application of the term transmission Protection Systems

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

A Review of America s First Step Towards the Harmonization of Portable Battery Standards: UL 62133

Constant voltage charger. Type UP 610. »We store the world's energy« Network

NEO XL NEO XL NEO XL POWER SUPPLIES - MADE IN SWEDEN ENGLISH

Maintenance Best Practices & Intervals for Substation Equipment. Presented by: Paul Schlies, President/CEO Energis High Voltage Services, Inc.

PRC-005. Tips and Updates. February 25th, Jonathan Hayes

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Distribution Control Center Operator Training

Supplementary Reference and FAQ

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

EPIC SERIES CONSOLE 2.0 EPIC YOUR DC SYSTEM ANYWHERE. hindlepowerinc.com JF Rev

Liquid Helium Level Instruments

A77 SNMPv1 SCADA INTERFACE INSTRUCTIONS

Part of the Crop Monitoring and Automatic control range. The most advanced automatic fan control and crop monitoring system available

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

INSPECTION AND TESTING FORM

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

DOCUMENTATION IPS640

DOCUMENTATION IPS640

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual

Commercial and Light Industrial Fire Alarm Control Panel

ANALOX 3000 Carbon Monoxide Monitor

CELLGUARD SYSTEM-ELS+ ELECTROLYTE LEVEL MONITORING SYSTEM. user GUIDE

Constant voltage 3-phase rectifier.

» EN50171» Lighting» Reliable

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

/9308 External Battery Chargers Installation Instructions

Optimizing Cold Weather Performance. Optimum Cold Temperature Performance From Biosystems Portable Gas Detectors

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

WIRELESS TOW ALARM SYSTEM (1ST GENERATION)

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Functional Performance Test

Supplementary Reference & FAQ. Draft

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

IWASAKI ELECTRIC CO., LTD

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

Rittal roof-mounted fans

AMG BMCS. Battery Management Conditioning System. Battery Failure has the potential for serious business disruption, data loss and more!

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

i-alert Monitoring Solution Sensor App Ai Platform

EMBEDDED MINI PROJECT LIST 2018

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

A77 SNMPv3 SCADA INTERFACE INSTRUCTIONS

Installation, Operating and Maintenance Manual

Standard PRC Transmission Relay Loadability

TPSD. Installation and Operation Manual. Filtered Battery Charger Power Supply / Battery Eliminator

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

RACK MONITORING SYSTEM - RAMOS Ultra

OWNERS MANUAL OPERATION GUIDE

CO warning instruments and gas spillage detectors

La Marche Manufacturing Company A36D. Battery Charger / Power Supply. Installation and Operation Manual

Liberty Premium 8. User Instructions

Siemens Process Automation End-user Summit- 2011

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

Taking Over-cum-A/T Document For Redeployed NSN BTS Sites

Transcription:

www.eepowersolutions.com Keeping an Eye on Your Critical Power! NERC PRC-005-2 Compliance Guide Ensure Reliability of Critical Backup Power Eagle Eye Power Solutions, LLC www.eepowersolutions.com

To Order Call Toll Free: 1-877-805-3377 Eagle Eye NERC Battery Monitoring Solution Compliance Solutions NERC Battery Monitoring Solution Eagle Eye Power Solutions provides battery monitoring solutions to power utilities worldwide. NERC (North American Electric Reliability Corporation) is a not-for-profit regulatory authority that ensures the reliability of the BES by enforcing reliability standards. NERC PRC-005 is the standard for Protection Systems Maintenance and Testing. PRC-005-2 requires utilities to document and implement programs for the maintenance of all protection systems affecting the reliability of the Bulk Electric System (BES). NERC PRC-005-2 -Table 1-4(f) Exclusions for Protection System Station DC Supply Monitoring Devices and Systems *Maximum Maintenance Interval: No periodic maintenance specified NERC Requirement Attributes / Eagle Eye Solution Any station dc supply with high and low voltage monitoring and alarming of the battery charger voltage to detect charger overvoltage and charger failure. BQMS: Monitors String Voltage Any battery based station dc supply with electrolyte level monitoring and alarming in every cell. ELM-Series: Monitors Electrolyte Level Any station dc supply with unintentional dc ground monitoring and alarming GFM-100: Monitors for DC Grounds Any station dc supply with charger float voltage monitoring and alarming to ensure correct float voltage is being applied on the station dc supply BQMS: Monitors String Voltage Any battery based station dc supply with monitoring and alarming of battery string continuity BQMS: Monitors String/Cell Voltage & Cell Internal/ Connection Resistance Any battery based station dc supply with monitoring and alarming of the intercell and/or terminal connection detail resistance of the entire battery BQMS: Monitors Cell Internal & Connection Resistance Any Valve Regulated Lead-Acid (VRLA) or Vented Lead-Acid (VLA) station battery with internal ohmic value or float current monitoring and alarming, and evaluating present values relative to baseline internal ohmic values for every cell/unit BQMS: Monitors DC Current, & Internal Ohmic Values for all Battery Types Any Valve Regulated Lead-Acid (VRLA) or Vented Lead-Acid (VLA) station battery with monitoring and alarming of each cell/unit internal ohmic value BQMS: Monitors Ohmic Value of Each Cell Maintenance Activities No periodic verification of station dc supply voltage is required. No periodic inspection of the electrolyte level for each cell is required. No periodic inspection of unintentional dc grounds is required. No periodic verification of float voltage of battery charger is required. No periodic verification of the battery continuity is required. No periodic verification of the intercell and terminal connection resistance is required. No periodic evaluation relative to baseline of battery cell/unit measurements indicative of battery performance is required to verify the station battery can perform as manufactured. No periodic inspection of the condition of all individual units by measuring battery cell/unit internal ohmic values of a station VRLA or Vented Lead-Acid (VLA) battery is required. 16

BQMS Battery Monitoring System The BQMS Battery Monitoring System is a modular system that allows for complete monitoring of a single or multiple battery systems. Parameters monitored include string voltage, DC current, cell voltage, cell / connection resistance, cell temperature, & ambient temperature. The BQMS is designed for use on vented lead acid, valve regulated lead acid, and nickel-cadmium battery systems. The included software package, Centroid 2, allows for remote viewing and data management of all connected Eagle Eye battery monitoring systems. 1 BQMS Modular Battery Monitoring Solution ELM-Series Electrolyte Level Monitor The ELM-Series is a reliable dual sensor system that monitors the electrolyte level and temperature of individual flooded batteries. Utilizing low cost, easy to install sensors, the system will alarm on low electrolyte level or higher than normal temperature. There are LED indicators on the system for visual alarming on site and alarm contacts for external alarming. The alarm contacts can be made as make-on-alarm or fail-safe mode and may be linked in to any facilities management alarm system. 1 ELM-Series (1) Battery Electrolyte Level Monitor (1) monitor and number of sensors per jars / cells 1) Model number varies per number of jars (Ex. ELM-60C for system with 60 jars) GFM-100 Ground Fault Monitor Compliance Solutions NERC Battery Monitoring The GFM-100 is a simple solution for monitoring battery ground faults. The unit reads battery bus status, detects out-of-limit conditions, and provides alarm indications per user settings. The monitor s status, under voltage & over voltage trip values, ground fault, time delay, and IP address settings are accessible on the color touchscreen. The GFM-100 Ground Fault Monitor has (2) Form C Alarm Contacts - each for positive and negative ground. 1 GFM-100- Ground Fault Monitor, available for 24V, 48V, 125V, or 250V 1) Determine part number for required voltage, Ex. GFM-100- would be GFM-100-125 for 125V applications. 17

To Order Call Toll Free: 1-877-805-3377 Eagle Eye NERC Portable Testing Solutions Eagle Eye understands the importance of testing and maintaining batteries per NERC PRC-005-2 standards. We offer complete battery testing kits and options that meet and exceed these requirements. The purpose of NERC PRC-005 is to document and implement programs for the maintenance of all protection systems affecting the reliability of the Bulk Electric System (BES) so that these protection systems are kept in working order. Compliance Solutions NERC Portable Testing Solution NERC PRC-005-2 -Table 1-4(a-e) 4 CALENDAR MONTHS - Maximum Maintenance Interval Verify station DC supply voltage IBE-Series Inspect electrolyte level SG-Series Inspect for unintentional grounds GFL-Series 6 CALENDAR MONTHS - Maximum Maintenance Interval Inspect condition of all individual units by measuring battery cell/unit internal ohmic values IBE-Series 18 CALENDAR MONTHS - Maximum Maintenance Interval Verify float voltage of battery charger IBE-Series Verify battery continuity IBE-Series Verify battery terminal connection resistance IBE-Series Verify battery intercell or unit-to-unit connection resistance IBE-Series Inspect cell condition of all individual battery cells where cells are visible - or measure battery cell/unit internal ohmic values where the cells are not visible IBE-Series Inspect physical condition of battery rack IBE-Series 6 CALENDAR MONTHS or 3 CALENDAR YEARS - Maximum Maintenance Interval VRLA Only Maintenance Activities EEPS Solution OR Verify that the station battery can perform as manufactured by evaluating cell/ unit measurements indicative of battery performance (e.g. internal ohmic values or float current) against the station battery baseline (6 calendar months) IBE-Series OR performance or modified performance capacity test of the entire battery bank (3 calendar years) SLB-Series 18 CALENDAR MONTHS or 6 CALENDAR YEARS - Maximum Maintenance Interval VLA Only Maintenance Activities EEPS Solution Verify that the station battery can perform as manufactured by evaluating OR cell/unit measurements indicative of battery performance (e.g. internal ohmic values or float current) against the station battery baseline (18 calendar IBE-Series months) OR performance or modified performance capacity test of the entire battery bank SLB-Series (6 calendar years) 6 CALENDAR YEARS - Maximum Maintenance Interval NiCd Only Maintenance Activities EEPS Solution performance or modified performance capacity test of the entire battery bank (6 calendar years) SLB-Series 18

Ultra-Max Plus Kit The Ultra-Max Plus Kit is the premier kit for NERC compliance for Vented Lead Acid (VLA) and Nickel-Cadmium (NiCad) batteries. The Ultra-Max Plus kit has three parts: an IBE-Ultra Portable Ohmic Battery Tester, SG-Ultra Max Digital Hydrometer, and Exmons Ultra+ Battery Management Software for all-in-one trending and reporting. The Ultra-Max Plus Kit tests internal resistance (internal ohmic values), voltage, inter-cell resistance (connection resistance), temperature, DC current, ripple current, specific gravity (state of charge), and electrolyte temperature. 1 Ultra-Max-Plus Kit IBE-Ultra Battery Tester, SG-Ultra Max Digital Hydrometer, Exmons Ultra Plus Software GFL-1000 Ground Fault Locator The GFL-1000 Ground Fault Locator is an essential instrument to pinpoint faulty grounding where electrical cables have breakage and loss to the ground. The unit measures current leakage of DC systems with high resistance. The GFL-1000 is designed to fast-detect, track, and locate virtual grounding faults for both offline and online DC systems. The GFL-1000 is used to meet NERC PRC-005-2 Compliance by inspecting for unintentional grounds for VLA, VRLA and NiCad batteries every four calendar months. 1 GFL-1000 Ground Fault Locator, Range: 24-1000V, 1-325 Hz SLB-Series DC Load Banks The SLB-Series Smart DC Load Banks monitor system voltage and cell voltage during discharge. The units are portable, durable, economic and come complete with software for data management. Capacity testing is a requirement every six years under NERC PRC-005-2 for VLA and NiCad battery banks and every three years for VRLA. Discharge testing is a direct measurement of the battery strings capacity and is essential to learning the true health of critical DC systems. The SLB-Series has over 80+ models to meet any utility battery system configuration. Compliance Solutions NERC Portable Testing Solution 1 SLB-Series* SMART Constant Current DC Load Bank with Monitoring (12-480V, 100-600A) *See catalog page 30 for complete model list *Add DAC after model number for wireless monitoring per cell 19