HYDROGEN SULFIDE REMOVAL SYSTEMS

Similar documents
SYSTEMS for CATALYTIC FILTERS

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

Aer-Max Installation Instructions

ispring Whole House Water Filter Systems USER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Installation, Operation, and Maintenance Manual

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Installation Instructions PP-AS20 Anti-Scale System

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction

INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

MIGHTY PRO 1/4 HP CHILLER

Kinetico 2060f OD Sulfur Guard Installation Instructions

Fleck 2510 SXT Catalox Installation & Start Up Guide

IMPORTANT SAFETY INFORMATION READ ALL...

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

Installation and Operating Instructions

INSTRUCTION MANUAL HS-229G

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

OPERATING INSTRUCTIONS

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

Ozone + UV Sanitation

Owner s Manual. Terpene Trap CF 1000

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

NOTICE TO INSTALLER: Instructions must remain with installation. FW Supersedes HomeGuard OPTIMA

Alkaline RO System INSTALLATION MANUAL

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual

A2Z Ozone, Inc. PRODUCT MANUAL

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2

EcoMaster - Residential Pools up to 40,000 Gallons

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Clean Water Made Easy

Genesis Whole House Chlorination System Page 2

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

MP-MBA-45T-1/60T-1 / 75T-1

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Residential Gas Hybrid Water Heater

MASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual

OPERATING AND INSTALLATION MANUAL

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

OPERATING AND INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS WARRANTY

Installation & Service Manual

Hardwired Electric Garage Heater

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

7500-S Sediment Backwash Filter Guide

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

BEFORE OPERATING THE MACHINE: WARNING

MKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual

Electric Garage Heater

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

55-Gallon Dispenser Package

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Arch Feeder: Installation Manual

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

55-Gallon Dispenser Package

52 CEILING FAN. Owner s Manual Models #50336, 50337

Hardwired Electric Garage Heater

INSTALLATION INSTRUCTIONS

Tankless Water Heater

gamma pond Ultraviolet Sterilizers

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Installation Instructions AS-WH Whole House Water Filter

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Duct Mount Atomizing Humidifier

Installation and Maintenance Guide

INSTALLATION INSTRUCTIONS

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

EcoMaster - Residential Pools up to 40,000 Gallons

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

DR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

QUICK PRIME INSTALLATION AND SERVICE MANUAL

2-Stage Under Counter Filtration System Model: WP-2 LCV

Whole House Descaler Installation Instructions

ACT Cartridge Dust Collector

Installation Manual & Owner s Guide

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

Transcription:

OX120U5, OX120U10 OX120B5, OX120B10 OX120U10R & OX120U5R INSTALLATION, OPERATION & SERVICE INSTRUCTIONS HYDROGEN SULFIDE REMOVAL SYSTEMS NO MEDIA NO CHEMICALS NO WASTE PRESSURE BOOSTING SYSTEM MODELS: OX120B5, OX120B10 STANDARD SYSTEM MODELS: OX120U5, OX120U10 STANDARD SYSTEM / RAW WATER BYPASS (for less than 1 PPM sulfide only) OX120U5R, OX120U10R US Patents: 6,080,306; 6,074,562; 6,481,456; 6,663,771; 6,884,358; 7,125,003 AFTER COMPLETING THE INSTALLATION LEAVE THIS MANUAL WITH THE END USER

TABLE OF CONTENTS GENERAL INFORMATION 2 CHECKLIST 3 SYSTEM COMPONENTS 4 PLUMBING THE SYSTEM 5 PLUMBING THE BOOSTED SYSTEM 7 WIRING THE BOOSTER PUMP 10 SYSTEM START-UP 11 TROUBLESHOOTING 12 WARRANTEE 14 GENERAL SAFETY INFORMATION Inspect for shipping damage and notify freight carrier and supplier immediately if damage is present. Annual maintenance must be done purge system of precipitants and to avoid restriction or contamination. System should be purged more often if iron or organics are present. Like any pressurized tank the tank or connections can over time weaken and leak or burst, possibly causing injury and or property damage. Repair any leaks and locate system where potential damage is minimized. Consult a water quality professional to test or evaluate your water and recommend any other necessary treatment for bacteria, chemical or other possible contaminants. Electrocution and explosion hazard! Before working on this product turn of the power and release all the pressure in the system. Product requires clean air. Locate in a well-ventilated area with access to fresh air. Surrounding area should be free from fumes, exhaust, chemicals, odors or similar toxins, which could be captured into the system. As in all water storage vessels and plumbing products, bacteria can grow especially during extended times of non-use. Consult your local plumbing and or treatment professional regarding any steps you may take to safely disinfect your home s plumbing system. READ CAREFULLY THE INSTALLATION, OPERATING AND SERVICE INSTRUCTION MANUAL TO AVOID PERSONAL INJURY AND PROPERTY DAMAGE AND TO ENSURE SAFE USE AND PROPER CARE OF THIS PRODUCT A QUALIFIED PROFESSIONAL MUST INSTALL THIS PRODUCT. 2

2. CHECKLIST The system utilizes high-pressure water and air to transform hydrogen sulfide into water and elemental sulfur. This solid collects on the bottom of the tank to be periodically purged. This process requires a minimum contact time of 55 minutes (on 68 F water) per PPM sulfide to complete. The system will provide on demand or all at once, sulfur free water equal to 38% of the water storage capacity and 75% of the storage capacity of the contact tank. Using the chart below, ensure the system you select is properly sized for the job, with the additional contact tanks if required. This sizing chart is for average households with typical water use patterns. Large hot tubs or other high volume fixtures should be added to the typical contact volume required. For example, a 2-person home with 2-ppm sulfide and an 80-gallon whirlpool tub would require an additional 80 or 120-gallon contact tank. Use the OX120B5 or OX120U5 for 5-9 GPM applications, the OX120B10 or OX120U10 for 10-15 GPM applications. Use the OX120U5I for 5-9 GPM treated and 30 GPM raw applications by adding the bypass check as shown in 4.A.3. Use the Oxidizer 80 or 120 gallon well tank with 15 GPM Inductor and optional 1-1/2 hp pressure booster for 15-25 GPM treated applications instead of the models in this manual. The well pump must be able to supply the minimum gallons per minute to the system at a pressure of at least 80 PSI to not use a booster pump. Sulfide Concentration SIZING CHART System & Number of Additional Contact Tanks Recommended 15 PPM + (2) CT120 + (3) CT120 10 PPM 5 PPM + (2) CT120 2 PPM + (2) CT120 + (2) CT120 1 PPM + (3) CT120 + (2) CT120 + (3) CT120 + (2) CT120 + (2) CT120 0.4 PPM Number of Residents 2 3 4 5 6 MODEL TANK CAPACITY DIMENSIONS AND PERFORMANCE DATA TANK WIDTH HEIGHT MINIMUM -- TREATED FLOW BOOSTER PUMP SIZE REQUIRED INLET PRESSURE MAXIMUM WORKING PRESSURE PIPE SIZE OX120U5 120 GALLON 24 72 5-9 GPM N/A 80-100 PSI 100 PSI 1 NPS OX120B5 120 GALLON 24 72 5-9 GPM ½ hp 10-50 PSI 100 PSI 1 NPS OX120U10 120 GALLON 24 72 10-15 GPM N/A 80-100 PSI 100 PSI 1 NPS OX120B10 120 GALLON 24 72 10-15 GPM ¾ hp 10-50 PSI 100 PSI 1 NPS OX120U5R 120 GALLON 24 72 5-9 GPM * N/A 80-100 PSI 100 PSI 1 NPS OX120U10R 120 GALLON 24 72 10-15 GPM N/A 80-100 PSI 100 PSI 1 NPS CT120 120 GALLON 24 72 0-25 GPM N/A N/A 100 PSI 1 NPS * Raw Water flow up to 30 GPM. System tank serves additionally as well tank with raw water bypass union check provided. Recommended accessories: Drain line for ¾ MPT pressure relief & 1 NPS tank drain 1 NPS pipe, shut-off valve, union & ordinary pipefittings and joint materials. 3/8 black poly tubing and connector 3

3. SYSTEM COMPONENTS RAW WATER BYPASS UNION CHECK VALVE (optional) Note: Items 4, 6, & 7 are bagged for the Standard kit only. Items 4 & 6 come with Booster 4

4.A PLUMBING THE SYSTEM (without a pressure booster) In order for the well pump to be eligible to drive the oxidation process through the Inductor on the standard system, the well pump must be able to supply a minimum of 5 gallons per minute to the system at a pressure of at least 80 PSI. If the pump is not capable of maintaining that pressure then use the booster pump which will also provide better pressure to the home. Sulfur concentrations over 10-ppm sulfide must have a minimum 90 PSI. Pressure on the well line from the well pump to the Inductor inlet may exceed 80 PSI. If you are using your own pressure booster, follow the directions under section 4.B PLUMBING THE SYSTEM WITH BOOSTER PUMP on page 7 substituting your own pump and pressure switch. Make certain that the pump performance curve is adequate before selecting any other pressure-boosting pump. If you need raw water for irrigation from the same well and are using the well pump without a booster pump, use the Raw Water Bypass option for 1-PPM sulfide. Use a different model, the Odor Oxidizer Pressure Tank with Raw Water Bypass option for 1-10 PPM sulfide or add a pressure booster to this model. Locate near drain adequate for the pressure relief or the momentary purge of sulfur compounds, which are trapped in the sump. The system should be installed in a dry location that provides adequate space for installation and service. As components age leaks may occur, therefore, do not locate in an area where water from the tank can cause property damage. Do not treat water over 100 F. Do not expose the system to temperatures below freezing as water freezing in the tank or components will break them. 5

4.A PLUMBING THE SYSTEM (without a pressure booster)(continued) 1 Position the Oxidation Tank as close to the well pump discharge as is practical using the Tank as the pressure tank for controlling the well pump. Also locate near the existing pressure switch so the control line can be as short as possible. See the installation diagram previous page. 2 Assemble the Air Inductor assembly as shown. Orient the pressure gauges so they can be read, but hand tight only. Inlet pressure gauge seals against an O-ring, however the system pressure gauge requires Teflon tape to seal. Install the Air Filter finger tight only as it may be removed later. Secure all unions hand tight. 3 Glue the outlet port of the Air Inductor to the Tank inlet. Note: If you are using the raw water bypass option, plumb a tee at the tank inlet and branch to the optional union check with the arrow towards the well pump. 4 Plumb the inlet of the Air Inductor to the well pump discharge line. Note: If you are using the raw water bypass option, Tee the check outlet to the well line at the Inductor inlet as shown. Do not reduce or restrict the well line. 5 Install a drain valve on the Tank drain and plumb the drain to the exterior or use a hose. Plumb the pressure relief to the exterior. Plumb the relief valve to a suitable drain. Failure to do so can result in flooding and property damage. 6 Remove the existing well pump Square D FSG pressure switch (if installed) and install the new pressure switch spring provided in the kit. This will give the desired pressure differential when adjusted later. Thread the ¼ Ell provided into the port on the pressure switch with Teflon tape finger tight. Loosen the compression nut then press one end of the ¼ tubing provided into the fitting so that the tubing is past the seal, then secure the nut finger tight. Plug the vacated switch connection. 7 Wire the pressure switch per local code. Secure the switch to the plumbing at a convenient location using the two switch clamps provided. The clamps attach to the switch from the bottom through the ground lug taps. Secure the ground to the new lugs the clamps provide. 8 Press the other end of the pressure control line from the pressure switch onto the control line fitting on top of the Air Inductor outlet. 9 Connect the vent line at the base to 3/8 polyethylene tubing (not provided) and run the length of tubing to the exterior. Air released from this line is humid and may corrode metal in the vicinity. Should the vent valve malfunction, water can spray from the line. Plumb the vent line to the exterior or to a suitable drain. 10 Plumb the outlet of the Tank with a ball valve to the treated line or contact tank inlet, if additional contact is needed. 11 When using a contact tank, install a drain valve on the Tank drain to the exterior as done in step 5, and then plumb the contact tank outlet to the treated line as done in step 10, or the next contact tank if additional contact is required. 6

4.B PLUMBING THE PRESSURE BOOSTED SYSTEM Locate near drain adequate for: The pressure relief and to drain the vessel. This system should be installed in a dry location that provides adequate space for installation and service. As components age leaks may occur, do not locate in an area where water from the tank can cause property damage. If installed outdoors in temperate regions, avoid roof drip edges that can concentrate rain fall onto the pump motor, or areas that flood and may submerge the motor. Any water treatment or handling equipment installed upstream must be vacuum resistant or vacuum protected in the event of a supply failure. Water pressure from the well must be from 10-50 PSI. The flow rate must always be greater than 5 GPM. An interruption of the water supply can result in heat damage and potential failure and leaking at the booster pump. To reduce this risk, your product includes a temperature-sensing switch that is designed to turn off if the pump is over-heated. Do not alter or remove this sensor. Electrocution and explosion hazard! Before working on this product, turn off the power to the pump and release the pressure in the system. Never install two pumps that draw in parallel on the same suction line or artesian well line. One pump will cause the other to become vapor locked and not perform properly or over-heat. Do not allow partially cured glue or other plumbing debris to enter the booster pump or Inductor at start-up. Always flush lines. Do not over-tighten fittings. Plastic treaded fittings should be snug; unions should be hand tight only. Make certain the pump performance curve is adequate before selecting any other pressure-boosting pump. Wire the pressure booster to the pressure switch as indicated by the pump manufacturer in compliance with local codes. To make wiring the booster pump easier, prior to the installation determine the best available electrical source. Then following the instructions 5. Wiring the Pressure Booster: connect with the ½ nut and wire the pressure switch to the booster. Then select the proper voltage wiring per the diagram on the pump motor and replace the motor connection access plate. This is much easier to do on a bench than on the floor. 7

4.B PLUMBING THE PRESSURE BOOSTED SYSTEM (CONTINUED) 1 Position the Oxidizer Tank and Booster Pump as shown previous page. The system must be plumbed in after the well pump pressure tank and any raw waterline must tee into the line ahead of the Pump inlet. 2 Assemble the Air Inductor assembly as shown. Orient the pressure gauges so they can be read, but hand tight only. Inlet pressure gauge seals against an O-ring, however the system pressure gauge requires Teflon tape to seal. Install the Air Filter finger tight only as it may be removed later in the installation. Secure all union connections hand tight. 3 Glue the outlet port of the Air Inductor to the inlet of the Tank. If you are feeding solution with a chemical pump, plumb a tee in the line between the Air Inductor and the Tank inlet for the injector. Avoid feeding chemicals ahead of the Air Inductor, as it may lead to scaling and sacrifice the performance of the air Induction. 4 Make a pump discharge fitting as shown with a 1 union. Thread the fitting into the end or discharge of the Booster Pump as shown. 8

4.B PLUMBING THE PRESSURE BOOSTED SYSTEM (CONTINUED) 5 Glue the Air Inductor inlet fitting to the Booster Pump discharge fitting using 1 NPS pipe. If you wish to elevate the Booster or locate the Pump on the inlet side, then you can glue 1 NPS ell(s) to the discharge pipe and set the pump horizontally even at another location within 20 using as few ell as is practical. The control line provided is only 6 long. 6 Plumb the supply line from the well tank to the inlet (top) of the Booster with a union. Make certain that all raw waterlines tee from the supply before the Booster inlet. Set the well pump cutout pressure so that it is lower than the Booster cut-in pressure (55-75 PSI). 7 Install a drain valve on the Tank drain and plumb the drain line to the exterior or adequate drain. Plumb the pressure relief discharge to the exterior or an adequate drain. Plumb the relief valve discharge to the exterior or a suitable drain. Failure to do so can result in flooding and property damage. 8 Thread the ¼ Ell provided into the port on the pressure switch with Teflon tape finger tight. Loosen the compression nut then press one end of the ¼ tubing provided into the fitting so that the tubing is past the seal, then secure the nut finger tight. 9 Press the other end of the pressure control line onto the pressure control fitting on top of the Air Inductor outlet. 10 Connect to the vent line 3/8 polyethylene tubing (not provided) and run the length of tubing to the exterior. The air released from this line is humid and may corrode metal in the vicinity. Should the vent valve malfunction water can spray from the line. 11 Plumb the outlet of the Tank with a ball valve to the treated line or contact tank, if required. 12 When using a contact tank, install a drain valve on the Tank drain as done above in step 7 and plumb to the exterior or an adequate drain. Plumb the tank outlet as done in step 11 to the treated line or contact tank if additional contact is required. 9

5. WIRING THE PRESSURE BOOSTER All wiring and fuse sizing are preliminary recommendations only. For your safety, local codes and in their absence, national codes must be followed to minimize risk of electrical shock, property damage or personal injury. Grounding the pump is essential for your protection and the protection of the motor. All wiring should be completed by a trained electrician and or qualified professional. The voltage of the pump must match the voltage of the power source. The ½ hp booster pump is factory set for 115 Volts. To connect to 230 volts make certain the power source is disconnected then wire to the junction box. Change the motor voltage setting on the booster motor following the wiring diagram located below and on the motor label. The ¾ & larger hp booster pumps are factory preset for 230 volts. The power leads should be large enough to carry the rated amperage. 1 Remove the plastic cover from the pressure switch and the lock nut from the ½ connector to the motor. Place the switch on the connector secured to the motor and secure the switch horizontally with the lock nut. Remove the electrical access plate from the back of the motor. 2 Pass the two pressure switch wires through the connector as shown. 3 Attach one of the pressure switch wire leads to the Line # 1 push-on tab and then attach the other lead to the Line # 4 push-on tab on the motor terminal board. If changing the voltage move the other wires as indicated in the diagram below. Replace the motor access plate when wiring is complete. 4 Now wire the pressure switch placing the ground on the ground lug first then placing the lines or the line and common on the two outside lugs. Connect the wiring at the electrical source. Replace the cover when wiring is complete. Secure the wires with the lug nuts firmly as loose lugs cause arcing and subsequent heat damage and failure. 10

6. STARTUP & ADJUSTMENT 1 After completing the plumbing remove the inlet union nut to the Air Inductor or to the booster pump and separate the line so the line can be flushed out to a bucket or drain. Turn the well pump on momentarily to flush out any line debris. Then reconnect the union. Line debris can cause the Air Inductor or the booster pump to malfunction, always flush the lines prior to pressurizing. 2 Turn off any drain valves and the Oxidizer Tank outlet valve. Restore power to the well pump and pressurize the system. You will hear water rush through into the Tank and later hear air venting from the vent valve until water reaches the set level. If using a booster pump: Immediately turn on power to the pressure booster. After the system is pressurized check for leaks. Often some vibration will occur in the Air Inductor. This will diminish in an hour and completely disappear in days as air from the installation trapped in the bypass damper is adsorbed. 3 Adjust the pressure switch to the desired pressure 59-74 PSI. It may be necessary to cycle the pump several times to achieve the proper setting. While filling the Tank and at cut-in the inlet pressure will be around 40 PSI greater. If not using a booster pump: The inlet pressure on the Air Inductor must be 20 PSI greater than the cut-out pressure setting on the Oxidizer Tank. The Air Inductor must draw air through the entire pump cycle. Air induction must be constant for thorough treatment. Check at this time that air is drawn when the system pump runs. Run the Oxidation Tank pressure as high as possible while still inducting air gives a longer pump cycle and higher oxygen levels for treatment. Never exceed the working pressure rating on the Tank. Higher pressure than rated can damage the unit; void the warrantee and cause flooding damage. 4 If using a contact tank to extend treatment capacity, fill the contact tank with the outlet valve off. Throttle the Oxidizer Tank outlet valve so pressure remains constant while filling the contact tank. Once pressurized open valve and vent the air displaced from the contact tank so it doesn t enter the home. Sulfur will be gone in the number of hours equal to the concentration of sulfide in PPM. (Example: 10 ppm H2S take 10 hours to remove). Waterlines require several day to clear up. Extremely caked lines require several weeks and line flushing to clear up completely. 11

7. TROUBLESHOOTING CHART 12

APPLICATION RECORDS AND NOTES 13

OXIDIZER LIMITED PRODUCT WARRANTEE This warrantee cannot be transferred- it is extended only to the original purchaser or first user of the product. By accepting and keeping this product you agree to all of the warranty terms and limitations of liability described below. Read carefully the installation, operation and maintenance instructions in this manual to avoid serious personal injury and or property damage and to ensure safe and effective use of the product. Aquatechnics warrants to the purchaser or first user of the new product that at the time of manufacture, the tank and component parts used with the product are free from defects and workmanship. Any warranty claim made must be made within (2) years unless another time period is set forth in this manual. Any warranty claim made on the pump must be made within (1) one year as is customary with pumps. In the event of a breach of the foregoing warranty Aquatechnics will, at it s discretion either make repairs or supply a new component or replacement part. Aquatechnics will not accept any claims for labor, property damage or other cost. This warranty does not cover any claim unless it was caused by a defect in material or workmanship during the warranty period. In addition this warranty does not apply: If the product is not correctly installed, operated, repaired or maintained as described in the manual; To any failure resulting from abuse (including freezing); improper or negligent: handling, shipping, storage, use, operation, accident; or alteration, lightning, flood or any other environmental condition; To any failure due to any use other than that specified in the manual. This Warranty does not cover any claims made to Aquatechnics or an authorized distributor or retailer more than 30 days after expiration of the applicable time period. This warranty also does not cover repair or replacement cost not authorized in advance by Aquatechnics. Aquatechnics must authorize any covered warranty service. Contact the person from whom you purchased the Product, who must receive authorization from an Aquatechnics distributor or Aquatechnics. If you do not receive a prompt response, contact Aquatechnics directly at the address below. Before Aquatechnics determines to provide any replacement part or component, it may as a precondition require that warranty claimant ship the product, postage prepaid to an authorized Aquatechnics representative, or to Aquatechnics and provide proof of purchase evidenced by the original sales receipt or product registration. In the case of replacement Aquatechnics reserves the right to make changes to the design, material, construction or to substitute components or products, which shall be subject to all of the terms and limitations of this warranty, except that the applicable warranty periods shall be reduced by the amount of time the warranty claimant owned the product prior to submitting notification of the warranty claim. 3811 W UNIVERSITY BLVD JACKSONVILLE, FL 32217 INFO@AQUATECHNICS.BIZ PRODUCT MODELS DURATION ODOR OXIDIZER ALL MODELS TWO (2) YEARS LIMITED WARRANTEE BOOSTER PUMP ALL MODELS ONE (1) YEAR LIMITED WARRANTEE 05/15/2008 AQUATECHNICS MANUFACTURING INC 14