INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

Similar documents
INSTRUCTIONS FOR HL-3 HOPPER LOADER HL-3 PPE SOUTH

INSTRUCTIONS FOR HL-9 HOPPER LOADER HL-9 PPE SOUTH

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

ADVANTAGE-100H-SC EXTRACTOR

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

Dust Collector. Sizes DC1 and DC2 U S E R G U I D E UGC

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

Dishwasher Installation Manual

Product Manual. Scotsman. Models: 10150, and 10250

Installation Instructions

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

PORT700CF Portable Fume Collector

XLT-60 EXTRACTOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

RINGMASTER 5-1/2 & 7 COTTON CANDY MACHINE

VACUUM LOADERS GSL Series

Frosty Factory of America, Inc.

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

Operator's Manual. PCP October 2017

IMpORTANT SAFETy INSTRUcTIONS

MODEL 7000 SUCTION UNIT

14 Upright Vacuum with HEPA Filter & Dual Power

VACUUM LOADERS GSL Series

MODELS: TJ45 TJ90 Operator s Manual

IMpORTANT SAFETy INSTRUcTIONS

COBRA -300H EXTRACTOR

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

HEDMAN DI-50. Endorser Instructions. Hedman DI-50 Operators Guide

COBRA -H EXTRACTOR 120V

PRO 2000i LOW LEVEL DEPOSITOR

DEMA 830 Laundry Master TM Installation Instructions

BLAST-IT-ALL BUMPER BLASTER

Owner s Manual & Safety Instructions

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Glass Door Merchandiser Refrigerator and Freezer

INSTRUCTION MANUAL POWER DRIVE UNIT MODEL PAD-350 ONE YEAR LIMITED WARRANTY

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

Bona DCS70/Portable DCS Manual and safety instruction

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Vacuum Receivers VR and VRP Series

STEAM WALLPAPER STRIPPER MODEL HTW5

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

MICRO CLEANER. OPERATOR MANUAL Advance MODEL /10 Rev E Document Number

Installation Instructions

HP310-C EXTRACTOR 120V

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

Model CBD OPERATORS MANUAL

HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)

OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION

Installation Instructions

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

Owner s Manual RD432-0 Chemical Controller

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

DEHUMIDIFIER. User Manual 50BT, 70BT

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Vacuum Receivers VR and VRP Series

Food Waste Disposer Instruction Manual

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

TLR Model Tube Loaders

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Installation Requirements for Models:

Installation Instructions

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

Bag-In-A-Box Oil Pump System

HEAT PUMP INSTALLATION MANUAL

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

Humidistat-Thermostat

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Operator s Manual S-333. Automated Soil Compactor. Version 3.3. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Liebert Xtreme Density Chiller (XDC) Unit Warranty Inspection Check Sheet

GENIUS 14 GENIUS 18 OPERATING & MAINTENANCE

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

R100 Oil-Less Refrigerant Recovery Unit

SSS Intrepid 16 FMS. Manual

MERCHANT POPCORN MACHINE SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL

GULPER 16SV 16 GALLON WET/DRY VACUUM WITH FRONT MOUNT SQUEEGEE

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Installation & Operating Guide

COUNTER SHOWCASE WARMER

THE BLACK PROVAC BACK PACK VACUUM CLEANER

Transcription:

INSTRUCTIONS FOR TAL SERIES VACUUM HOR LOADER TAL-15U 150 LBS PER HOUR MAGNETIC LEVEL SWITCH TAL-3U-E 450 LBS PER HOUR SIGHT GLASS WITH PROXIMITY LEVEL SWITCH Proportional Dual Feed Valve Available TAL-6U 660 LBS PER HOUR MAGNETIC LEVEL SWITCH TAL-12U 900 LBS PER HOUR MAGNETIC LEVEL SWITCH Revised Oct 2017 Copyright Plastic Process Equipment, Inc 2016 Our Vacuum Loaders are a exclusive only available from. Do not confuse these with any other make, model or manufacturer.

WARRANTY All machinery is warranted to be free of defective material and workmanship for a minimum period of 1 YEAR from date of sale. Some machinery components may carry longer warranties per our suppliers policies which are passed on to our customers (i.e. our drier compressors, conveyor motors, etc.). KNOW YOUR WARNING SIGNS AND SYMBOLS! This instruction manual uses the following signal words Caution and/or Danger and symbols to call attention to the degree or level of possible hazard seriousness. 1. CAUTION: A warning to indicate a potentially hazardous situation which, if ignored, may result in personal injury or threat of health. Also used to alert against unsafe practices which could cause property damage or accidents. See label B. 2. WARNING: Warns of a potentially hazardous situation which, if not avoided, could result in serious injury. Warning signs are a yellow triangle with a black border and black symbols. See Label A. 3. DANGER: Indicates an imminently hazardous situation which, if not avoided, may result in serious injury or death. This signal word is limited to the most extreme situations. Always follow the warnings or instructions that accompany the danger label, such as: High Voltage, Acid, Hot Surface, etc, etc, etc. See Label C. 4. SYMBOL/PICTORIAL: Conveys a message without words. See labels A & B. 5. SAFETY ALERT SYMBOL (an exclamation point inside a triangle): Is a general warning and indicates a potential personal injury hazard. Follow instructions and read labels and/or product information. See Label A. Label A Label B Label C HIGH VOLTAGE DISCONNECT POWER BEFORE OPENING BOX General Warning Sign Hazard Warning Sign Danger Warning Sign 2

INTRODUCTION AND GENERAL INFORMATION TAL-15, TAL-3U-E, TAL-6U & TAL-12U RECEIVING Please thoroughly inspect your TAL Series Vacuum Hopper Loader and report any damage to the motor freight carrier before uncrating for setup. They are responsible for any damage incurred during transit. Make note of model and serial numbers. These numbers must be used when ordering parts or accessories from. Before installation of this equipment the user must carefully read the Use and Operating Instructions to avoid damage to the machine and most important to avoid personal injuries. The TAL Series Vacuum Hopper Loaders are designed to convey virgin plastic bead materials via a vacuum motor which is selfcontained and does not require outside air pressure except for the filter cleaning blow-off system. A few of our many other features include our latest Euro-Style designs, stainless steel hoppers to avoid material contamination with high surface polish, noise reducing motor covers, air filter blow-off system and most important, a remote control pad with a 6 foot line cord for extra operator safety while making settings and adjustments. CHARACTERISTICS OF TAL SERIES VACUUM LOADERS A. All models TAL-15U, TAL-3U-E, TAL-6U and TAL-12U utilize a vacuum type carbon brush high speed motor for maximum power in a compact design. B. The models TAL-15U, TAL-6U and TAL-12U hoppers use a bottom hinged dump valve and a magnetic sensor switch for dependable long life. The dump valve must swing freely to empty the material. The model TAL-3U-E features a material sight glass and proximity level control switch for those that wish to view material flow. It also requires a smaller 1-9/16" dia. hole in your hopper lid. C. Loader mounting bases have multiple mounting holes to aid installation. See diagram. D. The filter auto-clean function can be set with the program pendant. The filter must be kept clean for maximum suction. Keep the filter clean!! E. The vacuum motors are equipped for a soft start function set with the control pendant. F. All electrical components are enclosed within the control box for user safety and security. All electrical work of any kind, if necessary, must be done by a licensed professional electrician. All power sources and the unit power switch must be turned off before any maintenance can be performed. 3

CAUTION NOTICE: All service work should be carried out by a person with technical training or corresponding professional experience. The manual contains instructions for both handling and servicing. The Trouble Shooting section contains service instructions intended for service engineers. Other sections contain instructions for the daily operator. MODIFICATIONS: WARNING! Do not modify this machine in any way. Modifications of any kind not only void any warranty, but it can cause serious injury or damage to personnel or equipment. INSTALLATION: The TAL Series Vacuum Hopper Loader must be mounted on a flat horizontal surface. It must be fastened to the cover of the material feed hopper or your barrel feed throat to avoid tipping over. Precautions must be taken to prohibit the fasteners from loosening and falling into the feed throat (i.e.: nylok nuts, lok-tite, etc.). The unit must be mounted so that the discharge counterweight dump valve swings freely without hitting anything. The counterweight has been adjusted at the factory and should not require any readjustments. The feed probe is secured to the feed hose with the supplied hose clamps. The other end of the hose is connected to the inlet tube located on the loader unit. A ground wire must be installed inside the feed hose to make a good connection between the feed probe and the loader unit. We suggest you use 18GA wire and strip 1-1/2" at each end and pinch the stripped ends between the feed hose and the mounting tubes it slides over. Failure to connect the ground wire can cause excessive static buildup and can result in possible static shock to personnel or damage the unit. When the TAL Series Vacuum Hopper Loader is in operation the feed hose should not have any sags or goose-necks, like the trap under a sink. If the hose sags, when the unit shuts off the material in the hose will fall to the bottom of the sag and can plug the feed hose and restrict suction. When inserting the feed probe into your material gaylord, do not jam the probe in! Insert the probe gently until it is about 1/4 to 1/3 submersed. When the unit is turned on, the probe will pull itself toward the bottom of the gaylord. Check this after a few cycles. WARNING STATIC SHOCK HAZARD All Vacuum Hopper Loaders are supplied with a vacuum hose that contains a ground wire to help control static electricity for user safety. We also recommend you install an extra static ground wire on your TAL Series Vacuum Hopper Loader unit. The ground wire should be run INSIDE your feed tube and connect the probe to the hopper loader frame. This will help to dissipate the static charge generated by some plastics as they are conveyed up the tube. You can use a standard 18 gauge electrical wire, strip the ends about 1-1/2" and pinch them between the plastic feed hose and the metal tubes that it mounts over, then clamp it securely with the supplied hose clamps. STATIC SHOCK HAZARD WARNING 4

ELECTRICAL The TAL Series Vacuum Hopper Loader comes wired for 120/60/1 power. Always use a grounded 120 volt outlet. If you must use an extension cord, ensure that the extension cord's rating is of the proper size. Failure to do so could cause a low voltage condition and premature failure of the motor. Be sure the control box power switch is off before you power up! SETTING THE UNIT After the unit has been installed and grounded, plug in the power cord. Next move the power switch to the "ON" position. The lights should flash and the unit should begin to cycle. See programming instructions. The green power light will remain on. For optimum performance the unit should run just long enough to fill itself. A full unit is indicated by a higher pitched motor sound because it cannot accept more material. Run several cycles and decrease the "CONVEY" time slightly each cycle until the motor shuts off at approximately the same time it is full. If the unit is allowed to run after it is full, performance will decrease or you may burn out the motor! The load time can be adjusted from 0 to 99 seconds (Note: these are approximate times and may vary by a few seconds). In general, longer load times will be needed for: longer distances, heavier materials, and increased amounts of regrind. Do not use with powder materials. Your TAL Series Vacuum Hopper Loader was designed to operate on the ON DEMAND principal. In the event there is a shortage of material the red Material Shortage light will begin flashing and an alarm buzzer will sound. When your machine material hopper is full the unit will sense this because the loader dump valve will remain held open by the presence of your material. As long as the dump valve remains open the unit will not cycle. As the machine hopper material level lowers, the dump valve will freely swing closed and the loader will begin to cycle again. 5

PROGRAMMING INSTRUCTIONS Control Box with removable Pendant 6 ft. Cord to Control Box Fuse Holder On-Off Switch 6 ft. Line Cord 13 ft. extention available Green: Power and Run Light Red: Material Shortage Alarm buzzer & flashing red light Control Pendant OPERATING INSTRUCTIONS Be sure power switch is in the off position before you plug it into a 120 volt receptical. When unit is energized it will be in standby mode. To start Hopper loader Press the run/set button. The hopper loader must fill the hopper in 3 cycles Or the alarm will be activated. PROGRAMMING Loading Time: Press & hold the down button (momentarily) until the number flashes, then set the loading time 0-99 seconds. Off Time: Press and hold the run/set button until "TO" appears on the screen, then hit the down/up button to adjust the time the hopper loader is off, then set the off time to 0-99 seconds. Air Blow Off time: Press and hold the run/set button until "TO" appears on the screen, then press the run/ set button again until "HT" appears on the screen. This is for the amount of time the air blast will stay on to clean the filter, set the air blow off time to 0-99 seconds using the down/up arrows. To set the number of cycles in between air blow off, press & hold the run/set Button until "TO" appears on the screen, then press the run/set button twice to get "CO" to appear on the screen. Press the down/ up arrows to set the number of cycles in between air blow offs. No Material Alarm: Press and hold the run/set button until "TO" appears on the screen, then press the run/ set button 3 times to show "Cl" on the screen. Then press the up/down button to show either 0, 1 or 2. "0" shuts this alarm Off, "1" will activate the alarm after the hopper loader does not load material the first time. "2" will activate the alarm after the hopper loader does not load material after 2 cycles. 6

MAINTENANCE The TAL Series Vacuum Hopper Loader is a filtered unit. There is a diaphragm type filter located between the top and bottom halves of the loader housing. This filter should be checked weekly. The automatic air blow-off system should help keep the filter clean, but checking is required to make sure there are no tears or holes. The Air Blow-Off requires a 8mm dia. air hose. Extra filters are available from. WARNING: The brushes should be changed BEFORE the brush stunt touches the commutator. On reassembly and handling, the lead wires must be kept away from rotating parts and motor frame. To achieve best performance, the new brushes should be seated on the commutator before full rated voltage is applied. After brush change, apply 50% to 75% of rated voltage for thirty minutes to accomplish this seating. The motor will return to full performance after thirty to forty-five minutes of running at full rated voltage. CAUTION: The motor must not be run with the material vacuum suction line air inlet blocked or sealed off. Check your material probe for blockage. DIRECT APPLICATION OF FULL RATED VOLTAGE AFTER CHANGING BRUSHES MAY CAUSE ARCING, COMMUTATOR PITTING, AND REDUCED OVERALL LIFE. If reduced voltage is unavailable, connecting two motors of similar rating in series for thirty minutes will accomplish the brush seating. * MACHINE SPECIFICATION TABLE MODEL TAL-15U TAL-3U-E TAL-6U TAL-12U Motor Type Carbon Brush Carbon Brush Carbon Brush Carbon Brush Motor Power 0.412 kw /.55 H.P. 0.412 kw /.55 H.P. 1.15 kw / 1.5 H.P. 1.15 kw / 1.5 H.P. Pipe Diameter 1-1/2" 1-1/2" 1-1/2" 1-1/2" Conveying Capacity 150 lbs / hr 450 lbs / hr 660 lbs / hr 900 lbs / hr Hopper Volume 2 lbs 4-1/2 lbs 8-1/2 lbs 17 lbs Sight Glass n/a 4-1/4 or 16 oz. n/a n/a Power Supply 110V / 50Hz / 1 110V / 50Hz / 1 110V / 50Hz / 1 110V / 50Hz / 1 Filter Automatic Blow-Off Standard Standard Standard Standard Discharge Hole Req'd. 6-1/4" dia. 1-1/2" dia. 8-1/4" dia. 8-1/4" dia. Height 20" 25-1/2" 23" 25-1/2" Width 10" 10" 12" 15" Depth 15" 14" 18" 21" Weight 22 lbs 24 lbs 26 lbs 31 lbs Conveying capacity tested @ 13 ft. vertical & 3 ft. horizontal. * Filter Blow-Off Air Pressure required 56 to 85 P.S.I. 7

TROUBLE SHOOTING POSSIBLE REASON EXCLUSION METHOD Motor does not work for a long period after the material is discharged. Loader for several times in a row tries to suck the material or the material shortage alarm occurs. 1.) Motor fault or electromagnetic switch fault. 1.) Repair or replacement. 2.) Magnetic reed switch or proximity sensor. 2.) Adjust or replace. 3.) Signal line broken 3.) Reconnect signal wire. 1.) Raw materials have been used up. 1.) To add raw materials. 2.) Air pipe leakage. 2.) Lock or replace the air duct. 3.) Filter plugged. 3.) Clean filter. Motor does not operate. The motor is burned out. Check replacement. After starting it blows the fuse. Short circuit somewhere. Check the line. Motor keeps running after hopper is fully loaded. TROUBLE SHOOTING 1.) Circuit board fault. 2.) Solenoid valve switch contact. 3.) Sensor switch bad. Repair or replace. BASE MOUNTING DIMENSIONS MODEL TAL-3U-E 4-3/4 1-31/32 7/16 Use RTV or seal gasket here. 4-3/4 1-31/32 1-9/16 8

BASE MOUNTING DIMENSIONS MODELS TAL-15U 11/32 4 Places Be sure O-Ring seal is in place. 6.31 I.D. 7.10 O-Ring Groove 7.79 8.65 O.D. MODELS TAL-6U & TAL-12U 3/8 4 Places Be sure O-Ring seal is in place. 8.53 I.D. 8.98 O-Ring Groove 10 10.79 O.D. 9