Proulx, G.; Richardson, J.K. NRCC-45663

Similar documents
Why Building Occupants Ignore Fire Alarms

ire safety in high-rise apartment buildings

FALSE ALARM ACTIVITY IN THE U.S. 2012

FIRE DEPARTMENT CALLS AND FALSE ALARMS

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

How design fires can be used in fire hazard analysis

Unwanted Fire Alarms. Marty Ahrens National Fire Protection Association 1 Batterymarch Park Quincy, MA (617)

Some information I have read tells me to evacuate immediately in case of fire. Fire In Your Residential Building. To Go?? To Stay??

High Rise Floor Wardens

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

EMERGENCY PROCEDURES FLIP CHART

Floor Warden Training. Thursday, May 27, 2015

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

Fire evacuation drill

Circulation Report for SIG-TMS Comments Document # 72

A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

Grossmont Cuyamaca Community College District Fire Report 2014

Grossmont Cuyamaca Community College District Fire Report 2012

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

FIRE SAFETY POLICY Page 1 of 15 Reviewed: October 2017

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

NY Fire Safety Institute Coordinator of Fire Safety & Alarm Systems F-80

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

Floor Warden Training

University Design Standard Fire Alarm Systems

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

FIRE SAFETY PLAN FIRST & JASPER JASPER AVENUE

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM

FIRE PREVENTION AND PROTECTION*

5 Key Stages to Risk Assessment

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

FACILITY OF EMERGENCY PLAN. (Template)

The Residences at Christina Landing Wilmington, DE

Date Issued: December 14, 2017 Revision: 2.1

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

3.1 Introduction. 3.1 Introduction

Emergency Evacuation Plan

Changes in NFPA

A DESCRIPTION OF THE PROBABILISTIC AND DETERMINISTIC MODELLING USED IN FIRECAM

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES

University of Maryland FIRE EVACUATION PLAN

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

Maintaining Building and Fire Safety During Active Assailant Events and Other Terrorist Events

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

INSPECTOR I SKILLS ADMINISTRATION

Granite Park EMERGENCY PLAN Granite Parkway Plano, Texas P a g e

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

FIRE SAFETY POLICY Revised March 2013

Human Factors - Egress Analysis for High Hazard Occupancies. Presented by: Michael J. Klemenz, PE, SFPE

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Fire Safety Management

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Agency for Health Care Administration

Occupant behaviour and evacuation

2010 Fire Log Fire Log. Annual Fire Safety Report

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

Hospital Codes, Safety, Exposure Control, Emergency Plans Handout

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

NFPA 72 Code Changes vs 2013

Fire Safety Protocol

Property Name & Address [ Property Name ] - [ Property Address ]

RAMBLER PARK FIRE SAFETY INFORMATION

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

Bold items are particular to the City of Euless

Fire Command Keypad. XR5 User s Guide

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Bob Rombach Quality Compliance Group University Fire Marshal, State Fire Inspector and Staff Architect

RESIDENT FIRE AND EMERGENCY PREPAREDNESS HANDBOOK

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

2017 Annual Fire Safety Report

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

World Trade Center Evacuations

Fire Safety Guide. Emergency Numbers:

ICC CODE CORNER 2015 International Fire Code

FIRE EMERGENCY POLICY

IRVING FIRE DEPARTMENT EMERGENCY PLANS

FIRE PREVENTION The Gory Story

WORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS

Table of Contents. EMERGENCY PROCEDURES Policy 190

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

Susquehanna University Annual Fire Safety Report 2015

Consultant Specification AGILE Wireless Fire Detection System

Fire Evacuation Plan Davidge Hall. UMB POLICE or

EMERGENCY RESPONSE PLAN

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Statistics. Fire Departments respond to a fire every 24 seconds

2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment

Emergency Evacuation Plans and Exercises. Risk Management Services

Transcription:

The Human factor : building designers often forget how important the reactions of the human occupants are when they specify fire and life safety systems Proulx, G.; Richardson, J.K. NRCC-45663 A version of this document is published in / Une version de ce document se trouve dans : Canadian Consulting Engineer, v. 43, no. 3, May 2002, p. 35-36 www.nrc.ca/irc/ircpubs

The Human Factor : Building designers often forget how important the reactions of the human occupants are when they specify fire and life safety systems By Guylène Proulx, Ph.D., and Ken Richardson, P.Eng. Building designers often view fire safety as providing a series of construction and hardware solutions, such as fire resistance ratings, exit stairs, automatic sprinklers and smoke control. Over the past decades, however, in many cases at considerable cost, it has been found that these built-in features do not necessarily establish occupant safety at the desired level. What is often missing is an adequate recognition of the importance of the behaviour and reactions of the human occupants. By applying an occupantbased approach, whether this means selecting the right equipment or implementing education programs, it is more likely that the fire safety solutions will support the safe evacuation of occupants in the event of a fire. This article addresses just some occupant-based solutions that have been shown by research to have a significant impact on improving fire safety. Alarms and audibility It is easy to believe that occupants should be quickly and easily alerted by fire alarms and that these alarms will ensure people will undertake appropriate actions -- but that is not always the case. In today's world where bedrooms and apartments are acoustically isolated, designers must compensate and ensure that the alarm signal is able to be heard.

2 Researchers have discovered significant problems with fire alarm audibility. To waken occupants, the Canadian Codes specify a minimum sound pressure level of 75 dba in bedrooms. However, the specified maximum sound pressure level is 100 dba to prevent hearing damage, so designers must give careful consideration to the location of fire alarm sounding devices. In many cases, devices will be required in every apartment (or in every bedroom in a house) to ensure audibility and to avoid exceeding the 100 dba limit with corridor-installed devices. Research is now available on the attenuation of alarm signals in residential buildings to allow designers to better locate sounding devices.1 The factors which determine the attenuation of sound include the hardness of the room and its furnishings (soft surfaces absorb more sound); size of the room, the number of rooms between the sounding device and the occupant and whether or not there is a closed door. Special devices may also be needed to alert occupants with hearing limitations.2 Special vibrating devices or strobe lights (or both) may be used to alert these occupants to the fire alarm. Need to take action To warn occupants of the need to take action, the fire alarm signal must be distinctive so that there is no ambiguity in the occupants' minds that this warning signal is a fire alarm. To achieve this, the National Building Code now requires a temporal pattern fire alarm signal, the international signal for evacuation. This "temporal 3 pattern" (see Figure 1) Figure 1 describes the sound from the alarmis intended to cause occupants to take evacuation action.3 According to research, 94% of building occupants are not familiar with the temporal 3 pattern alarm signal and don't know it means they should commence evacuation. Since it will still be many years before all buildings are equipped with the temporal 3 pattern signal, building operators must educate occupants about its meaning.

3 Research also has shown that occupants of large buildings tend to ignore fire alarm signals, regardless of the type of signal.4 The problem stems primarily from the frequent nuisance or "false" alarms. Estimated Sources of Nuisance Alarms as Reported by U.S. Fire Departments System Malfunctions 45.0% Unintentional Calls 27.0% Malicious, Mischievous Calls 15.8% Other False Alarms (bomb scares, etc.) 12.2% Designers can halve the number of nuisance alarms by simply ensuring that the fire alarm system equipment is reliable and malfunctions as little as possible. In addition to specifying quality equipment and its installation to current standards, the designer must provide for a long-term maintenance and testing program. There are also means by which a designer can protect fire alarm pull stations to make them less accessible to vandals or pranksters. Effective training can help reduce the unintentional alarms as well. If occupants are given feedback explaining the reason for an alarm activation, they will become more confident in the system and therefore will begin to respond more appropriately to alarms. Begin moving Now that occupants know that the signal being heard is a fire alarm and not likely a nuisance alarm, it is essential for them to begin moving out of the building. During

4 experiments in mid-rise residential buildings,the time to start the evacuation varied from 2.5 to 5.3 minutes. Reasons given for the delay included getting dressed, gathering valuables, finding children and pets and looking in the corridor or out the window to see what is happening; i.e. investigating and finding information. The need to reduce this delay time to start an evacuation cannot be overemphasized. One method is to have regular evacuation drills. Another is to have messages transmitted on voice communication speakers after the initial alarm signal. Research has shown that a voice message, through a voice communication system or directly from staff, is taken most seriously by occupants. It is important, therefore, for designers to specify speaker systems that will ensure voice messages are heard throughout the building, including the corridors and exit stairs. As well, the messages must be intelligible to be effective. CAD-compatible software is now available for first designing for voice intelligibility. Testing equipment is also available for assessing voice intelligibility in a building.4 Recorded messages have proven to be ineffective and even dangerous in some situations. It is important, therefore, that staff who will be sending voice messages have a clear understanding of what needs to be transmitted and that regular practice drills are conducted in conjunction with the local fire department. Occupants evacuate buildings by moving from their locations, through the common egress system -- usually corridors and stairs -- to reach a place of safety. The National Building Code requires that the egress routes be sufficiently wide to contain the occupants, be continuous to the outside and provide protection for the occupants along their path. That s not the whole story, however. Designers should also provide means to assist occupants during evacuation. Studies have shown that communication among occupants during an emergency is essential to ensure a successful evacuation.3 Designers should avoid (especially in

5 corridors and stairwells) very loud fire alarm devices that will impede this communication. Building egress systems can often be complex and non-intuitive to users. Research has shown the benefit of appropriate signage for wayfinding.5 Designers should not overlook this important aspect of ensuring occupant safety, especially in complex commercial buildings. Recent progress using photoluminescent way-guidance systems has show their value as a tool in aiding timely evacuation (Figure 3). Education and training Fire safety in buildings cannot be fully assured unless appropriate precautions are also taken during the ongoing occupancy of the building. These actions should be consolidated in the form of a Fire Safety Plan for the building, the original of which should be prepared, prior to occupancy, by the design team and the building managers in conjunction with the fire department. Copies of this plan should also be given to each tenant at the time of occupancy and to each subsequent tenant. As well, portions of the plan should be posted prominently throughout the building. Provision should be made for translation into other languages where necessary. Guylene Proulx, Ph.D. is a Research Officer with the National Research Council of Canada's Institute for Research in Construction. This article draws on previously published research by this author. Ken Richardson, P.Eng. is President of Ken Richardson Fire Technologies Inc. of Ottawa. Notes

6 1 Halliwell, R.E. and Sultan, M.A., "Attenuation of Smoke Detector Alarm Signals in Residential Buildings," Proceedings of the 1 st International Symposium on Fire Safety Science, Hemisphere Publishing Corporation, New York, NY, 1985. 2 United States Fire Administration, Emergency Procedures for Employees with Disabilities in Office Occupancies, Pub. No FA154, Emmitsburg MA. 1995. 3 National Fire Alarm Code Handbook, Supplement 4, National Fire Protection Association, Quincy, MA, 1999. 4 Bunker, M. and Edwards, R., "Huh? What Did They Say," NFPA Journal, Vol. 96, No. 1, National Fire Protection Association, Quincy, MA, 2002. 5 Arthur, P. and Passini, R., Wayfinding People, Signs and Architecture, McGraw-Hill Inc., New York, NY, 1992. Figure 1. Temporal-3 pattern for fire alarm signal Figure 2. Evacuation drill in a highrise apartment building with the participation of the local Fire Department Figure 3. Installation of photoluminescent wayguidance system; full lighting on the left and no lighting on the right