ENERGY COST AND FEATURE REPORT

Similar documents
Building Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form

Total Credits 0.00 *Please refer to Table R406.2 for complete option descriptions

Triple E New Construction. Doug Manthey Conservation Technologies Chad Trebilcock Minnesota Power

UPGRADES. [Energy Efficiency] Base Points

Intermediate framed denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.

Modular Construction. Live/Work Urban Infill Townhome. Modular Construction. Enclosure Design. San Francisco Bay Area Net Zero Urban Infill

RESNET HERS Rater Sample Test Questions 2

2015 RESIDENTIAL ENERGY CODE WORKSHEET BPA LOG# for Prescriptive Energy Code Compliance

Residential New Home Construction Checklist

Commercial load calculator instructions (all measurements are imperial)

2009 Washington State Energy Code Residential Sections

Air System Sizing Summary for AHU/CU-1 Project Name: Wilton Manors Fire Station#16 06/26/2016 Prepared by: L.N.I.

Air System Sizing Summary for Lobby System Project Name: Existing Lobby 04/04/2005 Prepared by: psuae

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

School of Mines Lecture Notes Residential R&D and the Residential Energy Efficiency Value Gap June 14, 2011

MANUAL J/S Summary One summary sheet for each system

BSC Building America High Performance Homes: Today & Tomorrow. Peter Yost Senior Building Scientist

b) Medium dwelling units that are not included in (a) above {small dwelling}, OR (c) below {large dwelling} Requires 3.5 credits

The Ad-Hoc Passive House. Paul W Panish

10 DEEP RETROFIT CASE STUDIES. Iain Walker Lawrence Berkeley National Lab

Company Acme HVAC Inc. Customer James Allen Preparer J White Address 3652 Shady LaneAnywhere, Earth Phone

Passive building in Hot and Humid Climates

SAMPLE. far, and we look forward to providing energy saving. Upgrade Details 8:30AM-5PM PST Mon-Fri

Triple E New Construction. Doug Manthey Conservation Technologies Chad Trebilcock Minnesota Power

TECHNICAL SPECIFICATIONS

NEW HOME CERTIFICATION PROGRAM 2018 PROGRAM GUIDE

Maine Single-Family Residential Baseline Study

Deemed Savings, Installation & Efficiency Standards

A highly efficient Enclosure is Key. The Building is always the sum of ALL it s parts

Residential Heating and Cooling Loads

WHAT S CHANGED WITH ANSI/RESNET/ICC STANDARD 380. Iain Walker, Residential Building Systems Group

2014 Florida Energy Code Software Verification Test Report: EnergyGauge USA version 4.0

Rater Provider Monthly Webinar REM Rate Modeling Tips March 23rd 2013

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

Pro Eco-Energy. Home Assessment

1. HAMILTON WAY, FARMINGTON, CT

RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES FOR RESIDENTIAL BUILDINGS

303 Garibaldi Ave, Roseto, PA Phone: Fax: Web: License: PA007413

Customized Energy Audit Report

MBPA Home Performance FIELD DATA COLLECTION FORM

Riverdale NetZero Project Summary of Costs and Expected Performance

407 Collins Ave, Cincinnati Specifications & Features Overview

RESEARCH HIGHLIGHT. Arviat E/2 Northern Sustainable House Energy Consumption Performance Assessment

Home Performance Analysis

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

SALT LAKE COMMUNITY ACTION PROGRAM

MEASURED PERFORMANCE DATA FOR

ENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

ENERGY SYSTEMS LABORATORY

Low-Impact Remodeling

Whole House Ventilation System Options Phase 1 Simulation Study

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings

In 1986, Pulte Homes in Tucson was

Single-Family Weatherization Baseline Assessment (R5) Final Report

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

Richard Hiles ClimateMaster

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

REQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw

Anderson Sargent Builders. Barley Pfieffer Architects. Building Science Corporation

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

InterNACHI Home Energy Inspection for th Street

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

What Works Lessons in German American Collaboration

COMcheck Software Version Mechanical Compliance Certificate

Prescriptive Path Technical Reference Manual Version

Perspective Looking at the South Facade Entering on the Ramp. Summery of Systems:

Energy Efficient Myth Busters

Energy Upgrade California Home Upgrade Offered by The Energy Network

2016 Title 24 HVAC Topics. June 4, 2013

2018 International Energy Conservation Code (IECC) Updates

Air-Sealing Beyond the Attic

90% Design Submittal Mechnical Equipment Calculations Parking Garage CDRL

New Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011

IT S ABOUT TIME FOR FRESH AIR.

Perspective Looking at the South Facade Entering on the Ramp. Summery of Systems:

SnuggPro DATA COLLECTION FORM

Energy Impacts of Various Residential Mechanical Ventilation Strategies

Closing the Gap: Getting Full Performance from Residential Central Air Conditioners. Task 4 - Develop New Climate-Sensitive Air Conditioner

Better Buildings By Design What are the best HVAC solutions for low-load, high performance homes? February 6-7, 2013

EnergyGauge USA Release Notes

ENERGY & WATER EFFICIENCY: HOME ASSESSMENTS. Jim Riggins Monument, CO

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

Technical Specifi cations

ENERGY AUDIT DATA COLLECTION/ HEALTH & SAFETY ASSESSMENT

Residential Energy Use ME 416/516

COMcheck Software Version Mechanical Compliance Certificate

Net-zero and Near Net-zero Homes in Jefferson County

7. MECHANICAL SYSTEM DESIGN

2008 Residential ACM Manual June 2007 Workshop Draft Page 1

Existing Buildings Standard Path Simulation Guidelines Version 6a

Controlling Indoor Humidity in High Performance Homes. Danny Gough, Energy Solutions, LP

Procedures for Verification of RESNET Accredited HERS Software Tools

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances

Overview. Case Study 2008 Building America Prototype ICI Showcase House. Daytona Beach, Florida. Project Team: ICI Homes, Building Science Corporation

Technical Specifi cations

Transcription:

ENERGY COST AND FEATURE REPORT Building Name: Rating Org.: GREEN DREAM GROUP, LLC ANNUAL ENERGY COSTS Heating $ 565 Cooling $ 0 Water Heating $ 0 Lights & Appliances $ 1402 Photovoltaics $ -189 Service Charges $ 264 Total $ 2042 Average Monthly $ 170 ENERGY FEATURES Ceiling w/attic: Vaulted Ceiling: Above Grade Walls: Foundation Walls (Cond): Found. Walls (Uncond): Doors: Windows: Frame Floors: Slab Floors: Infiltration: Infilt. Measure: Mechanical Ventilation: Interior Mass: Mech Equip List: Programmable Thermostat: None R-52 Foam INT. U=0.020 R-21, R-10 CONT. U=0.043 R-21, R-10 CONT INT R=21.0 None Steel-urth w/brk U=0.187 Dbl/LoE/Argon-Wood+ U=0.250 None R-5 Under Slab U=0.087 Htg: 0.20 Clg: 0.20 ACHnat Blower door test Balanced: ERV, 300 cfm, 250.0 watts. None Heating: Fuel-fired hydronic distribution, 60.0 kbtuh, 90.0 AFUE. Water Heating: Conventional, Gas, 0.63 EF. Heat=Yes; Cool=Yes

ENERGY COST AND FEATURE REPORT Page 2 Ducts: Duct Leakage: Lights/Appliances: Active Solar: Photovoltaics: Sunspace: NA NA Defaults DHW & space heating 2000 DC Watts No Notes: Where feature level varies in home, the dominant value is shown.

EQUIPMENT SIZING SUMMARY Building Name: Rating Org.: GREEN DREAM GROUP, LLC HEATING Calculated Peak Load (kbtu/hr) 48.6 Sizing Factor (%) 100.0 HEATING EQUIPMENT CAPACITY (kbtu/hr) Required 48.6 Specified 60.0 COOLING Calculated Peak Load (kbtu/hr) 0.0 Sensible 0.0 Latent 0.0 Sizing Factor (%) 0.0 COOLING EQUIPMENT CAPACITY (kbtu/hr) Required Total 0.0 Specified Total 0.0 Required Sensible 0.00 Specified Sensible 0.00 Required Latent 0.00 Specified Latent 0.00

PERFORMANCE SUMMARY Building Name: Rating Org.: GREEN DREAM GROUP, LLC Annual Load (MMBtu/yr) Heating 57.3 Cooling 0.0 Water Heating 0.0 Annual Consumption (MMBtu/yr) Heating 64.2 Cooling 0.0 Water Heating 0.0 Lights & Appliances 59.9 Photovoltaics -8.1 Total 116.0 Annual Energy Cost ($/yr) Heating $ 565 Cooling $ 0 Water Heating $ 0 Lights & Appliances $ 1402 Photovoltaics $ -189 Service Charges $ 264 Total $ 2042 Design Loads (kbtu/hr) Space Heating 48.6 Space Cooling 0.0 Utility Rates: Electricity: Gas: CHICAGO ELECTRIC CHICAGO GAS

COMPONENT LOAD SUMMARY Building Name: Rating Org.: GREEN DREAM GROUP, LLC HEATING SEASON (MMBtu/yr) Ceilings/Roofs 6.2 Rim/Band Joists 3.3 Above Grade Walls 18.6 Foundation Walls 9.7 Doors 2.9 Windows/Skylights 10.1 Frame Floors 0.0 Crawl Space/Unht Bsmt 0.0 Slab Floors 5.6 Infiltration 30.5 Mechanical Ventilation 2.5 Ducts 0.0 Active Solar -7.0 Sunspace 0.0 Internal Gains -25.1 Total 57.3

FUEL SUMMARY Building Name: Rating Org.: GREEN DREAM GROUP, LLC Annual Energy Cost ($/yr) Natural gas $ 553 Electric $ 1226 Annual End-Use Cost ($/yr) Heating $ 565 Cooling $ 0 Water Heating $ 0 Lights & Appliances $ 1402 Photovoltaics $ -189 Service Charges $ 264 Total $ 2042 Annual End-Use Consumption Heating (Therms) 637 Heating (kwh) 153 Lights & Appliances (kwh) 17531 Photovoltaics (kwh) -2364 Annual Energy Demands (kw) Heating 0.1 Cooling 0.0 Water Heating (Winter Peak) 0.0 Water Heating (Summer Peak) 0.0 Lights & Appliances (Winter Peak) 1.5 Lights & Appliances (Summer Peak) 3.1 Total Winter Peak 1.5 Total Summer Peak 3.1

FUEL SUMMARY Page 2 Utility Rates: Electricity: Gas: CHICAGO ELECTRIC CHICAGO GAS

AIR LEAKAGE REPORT Building Name: Rating Org.: GREEN DREAM GROUP, LLC Builder's Name: SELF Blower door test Whole House Infiltration Heating Cooling Natural ACH: 0.20 0.20 ACH @ 50 Pascals: 3.03 4.06 CFM @ 25 Pascals: 1767 2371 CFM @ 50 Pascals: 2773 3721 Eff. Leakage Area: 152.3 204.3 Specific Leakage Area: 0.00018 0.00024 ELA/100 sf shell: 1.44 1.94 Total Duct Leakage to Outside CFM @ 25 Pascals: CFM25 / CFMfan: CFM25 / CFA: CFM per Std 152: CFM per Std 152 / CFA: CFM @ 50 Pascals: Eff. Leakage Area: Thermal Efficiency: 0.00 Ventilation Mechanical: Balanced Sensible Recovery Eff. (%): 95.0 Total Recovery Eff. (%): 95.0 Rate (cfm): 300 Hours/Day: 24.0 Fan Watts: 250.0 Cooling Ventilation: Natural Ventilation ASHRAE 62.2-2003 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2-2003 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, a minimum of 98 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 195 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour.