38VYX025-R, 38VYX035-R

Similar documents
AIR CONDITIONER (MULTI-SPLIT TYPE)

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

INSTALLATION MANUAL ENGLISH FRANÇAIS AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-30, 32SK Series. Outdoor unit RAS-30, 32S Series

38VYX110/38VYX130 I S O INSTALLATION MANUAL

Installation Manual AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit RAS-5M34UAV-E1 RAS-4M27UAV-E RAS-3M26UAV-E. For OUTDOOR USE only.

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-05, 07, 10, 13, 16BKV-E. Outdoor unit RAS-05, 07, 10, 13, 16BAV-E

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

RAV-SM2246AT8-E RAV-SM2246AT8J-E RAV-SM2806AT8-E RAV-SM2806AT8J-E

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

AIR CONDITIONER (SPLIT TYPE) Installation manual. Outdoor Unit. English. Model name: For commercial use

AIR CONDITIONER (SPLIT TYPE) Installation manual. Outdoor Unit

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

[FLARE CONNECTION TYPE] ATTENTION

RAV-SM1104AT8P-E RAV-SM1104AT8JP-E RAV-SM1404AT8P-E RAV-SM1404AT8JP-E

AIR CONDITIONER (SPLIT TYPE) Installation manual. Outdoor Unit RAV-SM1603AT-E1 RAV-SM1603ATJ-E1. Model name: English. For commercial use

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

AIR TO WATER HEAT PUMP. Installation Manual. Outdoor Unit. Model name: HWS-P804HR-E HWS-P1104HR-E. English

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Split-type Air-Conditioner

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

Split-type Air-Conditioner

Choosing the installation site. Installation. 07 Choosing the installation site

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

AIR CONDITIONER INSTALLATION MANUAL INSTALLATIONSANLEITUNG MANUEL D INSTALLATION MANUAL DE INSTALACIÓN MANUALE DI INSTALLAZIONE

ROOM AIR CONDITIONER INSTALLATION MANUAL

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E. Model name: Slim Duct Type.

DAIKIN AIR CONDITIONER

INVERTER SPLIT - TYPE

Split-type Air-Conditioner

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

Split Air Conditioner

Installation manual for room air conditioner

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

INSTALLATION MANUAL. R410A Split Series. Models ARX20GV1B ARX25GV1B ARX35GV1B ARX20JV1B ARX25JV1B ARX35JV1B. Installation manual R410A Split series

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

AIR CONDITIONER (MULTI TYPE) Installation Manual. Outdoor Unit. English. Model name:

AIR CONDITIONER CONSOLE

SUPER MODULAR MULTI SYSTEM AIR CONDITIONER

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM1403DT-A RAV-SM1603DT-A. Model name: Concealed Duct High Static Pressure Type

INSTALLATION MANUAL. R410A Split Series. Models RXS20K2V1B RXS25K2V1B. Installation manual R410A Split series

SPLIT-TYPE ROOM AIR CONDITIONER

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION

GMZ3-24H-S GMZ4-28H-S GMZ4-36H-S

MMY-MAP0804T8P-E MMY-MAP1004T8P-E MMY-MAP1204T8P-E MMY-MAP1404T8P-E MMY-MAP1604T8P-E

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

Saunier Duval Clima, S.A.

MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL FTXN50KV1B FTXN60KV1B. R410A Split Series

AIR CONDITIONER INSTALLATION MANUAL INSTALLATIONSANLEITUNG MANUEL D INSTALLATION MANUAL DE INSTALACIÓN MANUALE D INSTALLAZIONE ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ

AIR CONDITIONER CASSETTE

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SP180CT-UL RAV-SP240CT-UL RAV-SP300CT-UL RAV-SP360CT-UL RAV-SP420CT-UL.

AIR CONDITIONER (MULTI TYPE) Installation Manual. Outdoor Unit. Model name: <Heat Pump Model> For commercial use

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION R410A INSTALLATION MANUAL

Installation Manual. Indoor Unit

E S F I P D G DB A(1) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

AIR CONDITIONER INSTALLATION MANUAL INSTALLATIONSANLEITUNG MANUEL D INSTALLATION MANUAL DE INSTALACIÓN MANUALE DI INSTALLAZIONE

CLIMATISEUR CACHÉ SYSTÈME SPLIT AVEC COMMANDE

INSTALLATION MANUAL AIR CONDITIONER OUTDOOR UNIT INSTALLATION MANUAL. INSTALLATIONSANLEITUNG Nur für autorisiertes Personal.

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type.

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

RAV-GM1101ATP-E RAV-GM1101ATJP-E RAV-GM1401ATP-E RAV-GM1401ATJP-E

R410A SPLIT SERIES DC INVERTER

Ductless Split Air Conditioner

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO )

AIR CONDITIONER OUTDOOR UNIT

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION

CENTRAL AIR CONDITIONER SPLIT SYSTEM

MCY-MAP0401TP Series MCY-MAP0501TP Series MCY-MAP0601TP Series

UltraV Series Outdoor Units

INSTALLATION MANUAL Duct Type Series MH FECA

AIR CONDITIONER SPLIT WALL MOUNTED

1. BEFORE INSTALLATION

AIR CONDITIONER OUTDOOR UNIT

E XEIPI IO E KATA TA H

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

1. BEFORE INSTALLATION

AIR CONDITIONER OUTDOOR UNIT

INSTALLATION MANUAL. R410A Split Series. Models RN60E3V1B. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM1607CTP-E

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

AIR CONDITIONER FLOOR CEILING

1. BEFORE INSTALLATION

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

RAV-SM566KRT-E RAV-SM806KRT-E

RAV-SP181BT-UL RAV-SP241BT-UL RAV-SP301BT-UL RAV-SP361BT-UL RAV-SP421BT-UL

1. BEFORE INSTALLATION

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUALE D INSTALLAZIONE MANUAL DE INSTALAÇÃO MANUEL D INSTALLATION INSTALLATIONS-HANDBUCH

Split Air Conditioner

Transcription:

38VYX025-R, 38VYX035-R GB OUTDOOR INSTALLATION MANUAL NL BUITENMODULE MONTAGE-INSTRUCTIES I ESTERNA MANUALE D INSTALLAZIONE GR ÏÄÇÃÉÅÓ ÅÃÊÁÔÁÓÔÁÓÇÓ X F EXTERIEURE MANUAL D INSTALLATION P EXTERIOR MANUAL DE INSTALAÇÃO D AUSSENGERÄT INSTALLATIONSANWEISUNG S UTOMHUSENHETEN INSTALLATIONSMANU E EXTERIOR MANUAL DE INSTALACIÓN FIN ULKOYKSIKKÖ ASENNUSOHJE

38VYX025-R, 42ADF025, 38VYX035-R 42ADF035 GB IT F D E NL ENGLISH Split system Hi-Wall indoor unit ITALIANO Climatizzatori split unità interna Hi-Wall FRANÇAIS Climatiseur split unité intérieure Hi-Wall DEUTSCH Split System - Wandgerät ESPAÑOL Acondicionador de aire split unidad interior Hi-Wall NEDERLANDS Split-system binnen-units voor wandmontage GR P S FIN PORTUGUÊS Climatizador de ar - sistema split unidade interior - mural SVENSKA Splitsystem Hi-Wall inomhusenhet SUOMI Split-järjestelmän Hi-Wall sisäyksiköt

CONTENTS PRES FOR SAFETY... 1 Installation Place... 2 Refrigerant Piping Connection... 3 Evacuating...3 Wiring Connection... 4 OTHERS Gas Leak Test...4 INDICE PRECAUZIONI PER LA SICUREZZA... 1 Luogo per l Installazione... 2 Collegamento dei Tubi del Refrigerante... 3 Evacuazione... 3 Collegamento dei Cavi... 4 ALTRI Test per Perdite di Gas... 4 SOMMAIRE MESURES DE SECURITE... 1 Endroit d Installation... 2 Connexion du Tuyau Réfrigérant... 3 Evacuation...3 Connexion des Câbles... 4 AUTRES Test de Fuite Gaz..... 4 INHALT SICHERHEITSVORKEHRUNGEN... 1 Aufstellungsort... 2 Anschluß der Kühlmittelleitungen... 3 Entleeren...3 Kabelanschlüsse... 4 SONSTIGES Überprüfung auf Gas-Undichtigkeit... 4 DEUTSCH FRANÇAIS ITALIANO ENGLISH

GB ENGLISH PRES FOR SAFETY For general public use Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheathed flexible cord (design H07RN-F) or cord designation 245 IEC66 (1.5 mm 2 or ). (Shall be installed in accordance with national wiring regulations.) New refrigerant air conditioner installation THIS AIR CONDITIONER USES THE NEW HFC REFRIGERANT (R410A), WHICH DOES NOT DESTROY THE OZONE LAYER. R410A refrigerant is apt to be affected by impurities such as water, oxidizing membranes, and oils because the pressure of R410A refrigerant is approx. 1.6 times of refrigerant R22. As well as the adoption of this new refrigerant, refrigerating machine oil has also been changed. Therefore, during installation work, be sure that water, dust, former refrigerant, or refrigerating machine oil does not enter the refrigeration cycle of a new-refrigerant air conditioner. To avoid mixing refrigerant and refrigerating machine oil, the sizes of charging port connecting sections on the main unit are different from those for the conventional refrigerant, and different size tools are also required. For connecting pipes, use new and clean piping materials with highpressure withstand capabilities, designed for R410A only, and ensure that water or dust does not enter. Moreover, do not use any existing piping as its pressure withstand may be insufficient and may contain impurities. To disconnect the appliance from the main power supply This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm in all poles. The installation fuse (25A) must be used for the power supply line of this air conditioner. DANGER FOR USE BY QUALIFIED PERSONS ONLY. TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF. FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK. CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE DAMAGED. CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION. DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS. FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION. TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC. WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED REFRIGERANT (R410A) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS. IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISONOUS GAS. WARNING Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches. Do not install in a place which cannot bear the weight of the unit. Personal injury and property damage can result if the unit falls. Before doing the electrical work, attach an approved plug to the power supply cord. Also, make sure the equipment is properly earthed. Appliance shall be installed in accordance with national wiring regulations. If you detect any damage, do not install the unit. Contact your Carrier dealer immediately. Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water. After unpacking the unit, examine it carefully for possible damage. Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and discharged air might disturb neighbors. To avoid personal injury, be careful when handling parts with sharp edges. Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation. REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures. Remark per EMC Directive 89/336/EEC To prevent flicker impressions during the start of the compressor (technical process), following installation conditions does apply. 1. The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of an impedance. Normally, the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max.! 2. No other equipment should be connected to this power line. 3. For detailed installation acceptance, please contact your power supplier whether its restriction does apply for products like washing machines, air conditioners or electric ovens. 4. For power details of the air conditioner, refer to the rating plate of the product. GB - 1

Optional Installation Parts Parts name Refrigerant piping Liquid side : 6.35 mm Gas side : 9.52 mm (38VYX025-R, 38VYX035-R) Pipe insulating material (polyethylene foam, 6 mm thick) Putty, PVC tapes Remark : Detail of accessory and installation parts can see in the accessory sheet. Q ty One each 1 One each Fixing bolt arrangement of outdoor unit Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind. Use 8 mm or 10 mm anchor bolts and nuts. If it is necessary to drain the defrost water, attach drain nipple 9 and cap water proof to the bottom plate of the outdoor unit before installing it. mm 275 mm 60 Air outlet 500 mm 97 mm Air inlet 38VYX025-R Drain outlet mm 31 0 m m 7 115 mm 32,5 mm m m 7 3 30 Air outlet 600 mm 38VYX035-R 125 mm Air inlet m m 1 0 2 90 mm Drain outlet 38VYX025-R 38VYX035-R A 400 mm 600 mm B 45 mm 100 mm Vinyl tape Apply after carrying out a drainage test. mm or 600 Bmmormoe r Extension drain hose (Not available, provided by installer) mm or 600 B mmor Saddle 1 00 m m o r m ore A mm or 600 mm o r moe r 1 00 m m or m or e A mm or Extension drain hose (Not available, provided by installer) 600 mm o r m o re 38VYX025-R 38VYX035-R Installation Place A place which provides the spaces around the outdoor unit as shown in the diagram A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration A place where the operation noise and discharged air do not disturb your neighbors A place which is not exposed to a strong wind A place free of a leakage of combustible gases A place which does not block a passage When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. An allowable length of the connecting pipe is up to 10 m for 38VYX025-R and 15 m for 38VYX035-R. An allowable height level is up to 8 m for 38VYX025-R and 10 m for 38VYX035-R A place where the drain water does not raise any problems 1. Install the outdoor unit without anything blocking the air discharging. 2. When the outdoor unit is installed in a place always exposed to strong wind like a coast or on a high storey of a building, secure the normal fan operation using a duct or a windshield. 3. In particularly windy areas, install the unit such as to avoid admission of wind. 4. Installation in the following places may result in trouble. Do not install the unit in such places. A place full of machine oil A saline-place such as the coast A place full of sulfide gas A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment Strong wind GB - 2

Flaring Refrigerant Piping Connection Evacuating GB ENGLISH After the piping has been connected to the indoor unit, you can perform the air purge together at once. 1. Cut the pipe with a pipe cutter. 90 Obliquity Roughness Warp AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump. Do not use the refrigerant in the outdoor unit. For details, see the manual of the vacuum pump. 2. Insert a flare nut into the pipe and flare the pipe. Projection margin in flaring : A (Unit : mm) Rigid (clutch type) Die Outer dia. of copper pipe R410A tool used Conventional tool used 6.35 0 to 0.5 1.0 to 1.5 9.52 0 to 0.5 1.0 to 1.5 Pipe Tightening connection A Imperial (wing nut type) Outer dia. of copper pipe R410A 6.35 1.5 to 2.0 9.52 1.5 to 2.0 Align the centers of the connecting pipes and tighten the flare nut as far as possible with your fingers. Then tighten the nut with a spanner and torque wrench as shown in the figure. Externally threaded side Half union Use a wrench to secure. Outer dia. of copper pipe Flare nut Tightening torque of flare pipe connections The operating pressure of R410A is higher than that of R22 (approx. 1.6 times). It is therefore necessary to firmly tighten the flare pipe connecting sections (which connect the indoor and outdoor units) up to the specified tightening torque. Incorrect connections may cause not only a gas leakage, but also damage to the refrigeration cycle. Internally threaded side Use a torque wrench to tighten. Do not apply excess torque. Otherwise, the nut may crack depending on the conditions. Tightening torque (Unit : N m) 6.35 mm 16 to 18 (1.6 to 1.8 kgf m) 9.52 mm 30 to 42 (3.0 to 4.2 kgf m) Shaping pipes 1. How to shape the pipes Shape the pipes along the incused line on the outdoor unit. 2. How to fit position of the pipes Put the edges of the pipes to the place with a distance of 85 mm from the incused line. Flare at indoor unit side Flare at outdoor unit side Incused line Using a vacuum pump Be sure to use a vacuum pump with counter-flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops. (If oil inside of the vacuum pump enters the air conditioner, which use R410A, refrigeration cycle trouble may result.) 1.Connect the charge hose from the manifold valve to the service port of the packed valve at gas side. 2.Connect the charge hose to the port of the vacuum pump. 3.Open fully the low pressure side handle of the gauge manifold valve. 4.Operate the vacuum pump to start evacuating. Perform evacuating for about 15 minutes if the piping length is 20 meters. (15 minutes for 20 meters) (assuming a pump capacity of 27 liters per minute) Then confirm that the compound pressure gauge reading is 101 kpa ( 76 cmhg). 5.Close the low pressure side valve handle of the gauge manifold valve. 6.Open fully the valve stem of the packed valves (both gas and liquid sides). 7.Remove the charging hose from the service port. 8.Securely tighten the caps on the packed valves. Compound pressure gauge 101 kpa ( 76 cmhg) Handle Lo Charge hose (For R410A only) Connecting pipe Pressure gauge Manifold valve Handle Hi (Keep full closed) Charge hose (For R410A only) Vacuum pump Vacuum pump adapter for counter-flow prevention (For R410A only) Packed valve at liquid side Packed valve at gas side Service port (Valve core (Setting pin)) KEEP IMPORTANT 4 POINTS FOR PIPING WORK. (1) Take away dust and moisture (inside of the connecting pipes). (2) Tighten the connections (between pipes and unit). (3) Evacuate the air in the connecting pipes using a VACUUM PUMP. (4) Check gas leak (connected points). GB 3 GB - 3

Packed valve handling precautions Open the valve stem all the way out, but do not try to open it beyond the stopper. Securely tighten the valve stem cap with torque in the following table: 3 L N 30 10 10 40 Gas side ( 9.52 mm) Liquid side ( 6.35 mm) Service port 30 to 42 N m (3.0 to 4.2 kgf m) 16 to 18 N m (1.6 to 1.8 kgf m) 9 to 10 N m (0.9 to 1.0 kgf m) Wiring Connection The hexagon wrench is required. 4 mm 1. Remove the valve cover from the outdoor unit. 2. Connect the connecting cable to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor unit. 3. When connecting the connecting cable to the outdoor unit terminals, make a loop as shown in the installation diagram of indoor and outdoor unit to prevent water coming in the outdoor unit. 4. Insulate the unused cords (conductors) from any water coming in the outdoor unit. Proceed them so that they do not touch any electrical or metal parts. Stripping length of the connecting cable Terminal block 1 2 3 L N Model 38VYX025-R 38VYX035-R Power source 50/60 Hz, 220 240 V Single phase Maximum running current 8A 11A Plug socket & fuse rating 25A Power cord H07RN-F or 245 IEC66 (1.5 mm 2 or ) Connecting cable Earth line Wrong wiring connection may cause some electrical parts burn out. Be sure to comply with local cords on running the wire from indoor unit to outdoor unit (size of wire and wiring method, etc.). Every wire must be connected firmly. This installation fuse (25A) must be used for the power supply line of this air conditioner. If incorrect or incomplete wiring is carried out, it will cause an ignition or smoke. Prepare the power supply for exclusive use with the air conditioner. This product can be connected to the mains. Connection to fixed wiring: A switch which disconnects all poles and has a contact separation of at least 3 mm must be incorporated in the fixed wiring. Earth line NOTE : Connecting cable Wire type : More than H07RN-F or 245 IEC66 Connecting cable OTHERS Gas Leak Test Check places for the indoor unit. Setting of Remote Control Selector Switch When two indoor units are installed in the separated rooms, it is not necessary to change the selector switches. Electric parts cover Valve cover Remote control selector switch When two indoor units are installed in the same room or adjacent two rooms, if operating a unit, two units may receive the remote control signal simultaneously and operate. In this case, the operation can be preserved by setting either one indoor unit or remote control to B setting. (Both are set to A setting in factory shipment.) The remote control signal is not received when the settings of indoor unit and remote control are different. There is no relation between A setting/b setting and A room/b room when connecting the piping and cables. Check places for the outdoor unit. Check the flare nut connections for the gas leak with a gas leak detector or soap water. GB - 4