TL-105 COLUMN HEATER

Similar documents
OPERATIONS MAINTENANCE MANUAL

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Service Manual Models CPH2 & CPH3

Installation and Operations Manual

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Model PT-05 Model PT-06

Inline Heater for Solvent or Gas. Installation and Operation Manual

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Duct Temperature Sensors

ion Genesis Pump Controller

Corrosion Resistant Fluid and Air Handling Systems.

Air Pump Up to 800 gallons

Blade Series Heat Exchanger Operation and Installation

OPERATING INSTRUCTIONS

Reacti-Therm I and III Heating Modules

92831 TEL: (714) FAX:

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.


DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Duct Mount. Installation Instructions

RATIO:GUARD Model E-1S EC Monitor

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

Isotemp Explosion-Proof Refrigerators and Freezers

Portable Roller Oven (115 Volt) (230 Volt) Instruction Manual. Updated 8/11/2015 Ver. 3.0

Series: MBC1-TC Mini Benchtop Temperature Controller

PM-200 Power Module Operating Instructions

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

Duct Humidity/Temp Sensor

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Liquid Level Controllers

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

MODEL 620 ELECTRICAL DATA: FEATURES: DIMENSIONS: SHIPPING INFORMATION: AVAILABLE ACCESSORIES: CONVECTION OVEN 1/4 SIZE PAN

INSTRUCTION MANUAL. T-SERIES Air Conditioner. T29 Model Pentair Equipment Protection P/N McLean Parts 5736 N. Michigan Rd.

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

SKORPION Process Air Heater

FOR EASY, FAST INSTALLATION AND FOR RESULTS

InstructIon Manual KrEs EQuIPMEnt stands

RTE-5/5B & RTE-9/9B Refrigerated Bath Circulators. NESLAB Manual P/N Installation, Operation and Service Manual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

108A OTP1800. Grid Support. General Description

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

Incutrol/2 Regulator

OPERATING MANUAL/ INSTALLATION

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

OPERATIONS FOOD HOLDING & TRANSPORT CABINETS. wîttco foodservice. equipment

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

MODEL HBX-1 P/N 3G59332

USER S OPERATING AND INSTRUCTION MANUAL

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

MACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS

MODEL REO-1620SE ELECTRIC RETHERMALIZER OPERATING INSTRUCTIONS

GENESIS Air Conditioner. M52 3-Phase Model INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

Multiple use Digital Thermometer With 7 Day Memory

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Cat 5 Pro Vacuum OPERATOR S MANUAL

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

MN908 No. 282C Replaces 282B LB7013

Isotemp Plus General Purpose Laboratory Freezers

TORRID MARINE YACHT QUALITY Since Owner s Manual

Outside Air Humidity & Temperature Sensor

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Ney BOX FURNACE. Owner's & Operator's Manual

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

TECHNICAL INSTRUCTIONS

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

TrueClean ToteCleaner

Wax Base Heater & Dispenser

T-SERIES Air Conditioner. T53 Model INSTRUCTION MANUAL nvent Rev. G P/N

Operation Manual and Parts Directory

Service Parts, Kits and Accessories

Eldex Column Heater. Operator s Manual

USER GUIDE CONTENTS. Please take the time to read this manual before operating the ventilator. Save this guide for future reference.

MaxLite LED Vapor Tight Linear Fixture

Room Humidity/Temp Sensor

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Operation Manual & Parts List

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

Transcription:

TL-105 COLUMN HEATER INSTRUCTION MANUAL Timberline Instruments Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com

Timberline Model TL-105 Column Heater Instruction Manual TABLE OF CONTENTS TABLE OF CONTENTS... 2 TL-105 FEATURES... 3 PRINCIPLE OF OPERATION... 3 ADVANTAGES OF HPLC COLUMN TEMPERATURE CONTROL... 3 ELECTRICAL DESCRIPTION... 3 Heater and Control Circuit Descriptions... 3 Thermal Fuse Protection... 3 Electrical Fuse Protection... 3 MOBILE PHASE HEAT EXCHANGER... 4 INJECTION OR SELECTION VALVE... 4 INSTALLATION... 5 INSTALLING AN INJECTION OR SWITCHING VALVE... 5 CONNECTING THE COLUMN... 5 CONNECTING THE DRAIN... 5 OPERATING INSTRUCTIONS... 6 SETTING THE TEMPERATURE... 6 APPENDIX... 7 SPECIFICATIONS... 7 ORDERING INFORMATION... 7 ACCESSORIES... 7 WARRANTY... 8 SHIPMENTS... 8 DAMAGED SHIPMENTS... 8 FILING OF CLAIMS... 8 RETURNS... 8 INDEX... 10-2 -

TL-105 FEATURES PRINCIPLE OF OPERATION The Timberline TL-105 Column Heater provides temperature control with a stability of 0.1 C. Typical accuracy of the RTD sensor and controller is within 1 C. The sophisticated microprocessor based controller contains PID calibration capability and a high temperature shut off. The system is calibrated before shipment and the PID constants are locked in memory. The temperature limit is set at 100 C. The limitation of the system for temperature is the gray polyuretane thermal insulation (107 C) surrounding the oven bed. ADVANTAGES OF HPLC COLUMN TEMPERATURE CONTROL Controlling the temperature of HPLC columns has many advantages including Retention time stability Reduced detector noise and baseline drift Simplified method transfer Elevating the column temperature can improve separations. Faster separation as retention decreases as temperature increases Improved peak shape by reducing on-column silanol effects Improved ion exchange efficiency Lower backpressures by to reduction in mobile phase viscosity Selectivity changes for better separations ELECTRICAL DESCRIPTION HEATER AND CONTROL CIRCUIT DESCRIPTIONS The microprocessor base controller provides a 5-volt signal, actuating a solid-state relay which, controls power to a 150-watt silicone heater. The controller sensor is a 100-ohm RTD probe inserted into a 0.16" hole in the aluminum block. The RTD probe is placed very adjacent to the silicone heater to provide close temperature control. THERMAL FUSE PROTECTION The heater is equipped with a secondary form of over temperature protection in a 128 C thermal fuse. If a failure occurs in the electronic circuitry, the thermal fuse will protect the apparatus against an over temperature condition. The thermal fuse must be manually reset when an over temperature condition opens the heater circuit. Contact Timberline for instructions. ELECTRICAL FUSE PROTECTION The standard configuration for 120V operation is two 2A, 250V fuse. The configuration for 240V operation is two 1A, 250V fuses. Timberline Instruments, Inc. - 3 - TL-105

MOBILE PHASE HEAT EXCHANGER The TL-105 Column Heater comes equipped with a pre-column heat exchanger. This passive device transfers heat from the floor of the heated zone to the inlet tubing. This action heats the incoming mobile phase prior to entry into the HPLC column. Without preheating, there is a significant difference in temperature between the incoming mobile phase and the column which greatly degrades column efficiency and causes severe band broadening and peak splitting. This is due to radial temperature and viscosity gradients in the column. When the mobile phase temperature is lower then the column temperature, the fluid temperature in the heated column will be higher near the wall then it is in the center. This will result in lower retention and viscosity near the tube wall causing peak broadening and splitting. Figure 1: HX-101 Heat Exchanger The HX-101 heat exchanger contains a spool, plus an inlet and outlet length, of stainless steel tubing, cast in a tin alloy. Surrounding the inlet tubing with metal greatly enhances the heat transfer characteristics. INJECTION OR SELECTION VALVE The TL-105 column heater has been designed to accommodate an injection or switching valve in the heated compartment. This placement allows the entire flow path to be held at the same temperature. The placement of the valve in the oven also allows for upstream preheating. In upstream preheating the heat exchanger is placed between the pump and the injection valve eliminating extra column band broadening from the volume of the heat exchanger. Timberline Instruments, Inc. - 4 - TL-105

INSTALLATION 1. The TL-105 will operate at 110, 220, or 240V (must be specified when ordering). Either 50 or 60- hertz power is acceptable. The set instrument voltage is shown on the input receptacle. 2. The TL-105 is furnished with a US style 110V AC line cord. If 220 or 240V is to be used, acquire the proper power cord to conform to local protocol. INSTALLING AN INJECTION OR SWITCHING VALVE The TL-105 is designed to accommodate the mounting of an injection or switching valve. Since the valve will reside in the same thermal environment as the heat exchanger and columns it is advised that the heat exchanger be plumbed into the system before the valve. Placing the heat exchanger before the injection valve will eliminate any extra column band broadening due to its volume. 1. Release the set screws on top of the oven and open the column compartment 2. Disconnect the heat exchanger from the bulkhead. 3. Remove the plate from the front panel of the TL-105 by releasing the 4 hex head screws. 4. Remove the handle from the valve and insert the shaft through the larger hole on the front panel plate. Secure it to the plate with the mounting screws. Replace the handle. 5. Position the plate on the front panel so that the valve goes through the hole in the column compartment. 6. Before securing the plate, reconnect the heat exchanger fitting and connect the column outlet tubing to the outlet bulkhead fitting on the inside of the plate. 7. Secure the plate to the front panel. 8. The injection valve vent/waste line should be routed out of the compartment through the hole in the left side of the case. CONNECTING THE COLUMN 1. Connect the outlet of the manual or automated injection valve to the bulkhead labeled INLET. The other side of this bulkhead is attached to the heat exchanger. 2. Release the set screws on top of the oven and open the column compartment. 3. Attach the outlet of the heat exchanger to the inlet of the HPLC column or guard column. 4. Attach the outlet of the HPLC column to the bulkhead side of the labeled OUTLET that is in the oven faceplate. 5. Connect the bulkhead labeled OUTLET on the outside of the TL-105 to the HPLC detector or post column reagent module. CONNECTING THE DRAIN Any accidental leaks in the column compartment will drain from the back of the compartment to the bulkhead on the right side of the oven near the lower back corner. Some corrosive or harsh organic liquids are incompatible with the drain materials. Use caution to avoid leaks in the oven when using such liquids. 1. Connect a piece of tubing to the bulkhead using a nut and ferrule. 2. Direct the open end of the tubing to a waste reservoir. *The drain is disabled on column heaters filled with aluminum shot. Timberline Instruments, Inc. - 5 - TL-105

OPERATING INSTRUCTIONS SETTING THE TEMPERATURE The lower red display on the digital controller is the set point. The set point can be adjusted with the two up/down arrow keys below the dual digital display. The upper green display is the actual temperature of the aluminum block at the center. The maximum set temperature for a standard TL-105 is 100 C. RED GREEN Actual Temperature of Aluminum Block Set Point The nominal warm up time for the TL-105 is 15-20 minutes. Generally the unit should be left on since the silicone heater is typically on a 10-30% duty cycle due to excellent insulation. Since the heater current is controlled by an oversized solid-state relay there is no wear on the parts in the TL-105. Timberline Instruments, Inc. - 6 - TL-105

APPENDIX SPECIFICATIONS Case Dimensions TL-105 & TL-105-HT 8 W x 20 L x 5 H Case Dimensions TL-105L & TL-105L-HT 8"W x 25½"L x 5"H Heated Cavity Dimensions TL-105 & TL-105-HT 3½ W x 17½ L x 2¾ H Heated Cavity Dimensions TL-105L & TL-105L-HT 3½"W x 23"L x 2¾"H Inlet Pre heater 0.0625 OD x 0.010 ID x 30 SS coil cast in tin alloy Heating Elements Etched Foil/Silicon, 150W Temperature Range TL-105 and TL-105L Ambient to 100 C Temperature Range TL-105-HT and TL-105L-HT 5 above ambient to 15 0 C Temperature Stability +/- 0.1 C Operating Voltage 120 VAC or 240 VAC (Must be specified by customer) ORDERING INFORMATION Description Catalog Number TL-105 Column Heater, 120VAC 2105-1 TL-105 Column Heater, 240VAC 2105-2 TL-105 Long Column Heater, 120VAC 2115-1 TL-105 Long Column Heater, 240VAC 2115-2 TL-105-HT (High Temp) Column Heater, 120VAC 2125-1 TL-105-HT (High Temp) Column Heater, 240VAC 2125-2 TL-105-HT (High Temp) Long Column Heater, 120VAC 2135-1 TL-105-HT (High Temp) Long Column Heater, 240VAC 2135-2 ACCESSORIES Description Catalog Number HX-101 Heat Exchanger, SS, 1/16" OD x 0.01"ID x 30"L 2201 HX-102 Heat Exchanger, SS, 1/16" OD x 0.02"ID x 30"L 2202 Timberline Instruments, Inc. - 7 - TL-105

WARRANTY Timberline Instruments, Inc. (Timberline) warrants its products and services to meet the written performance and quality and to be free of defects in material and workmanship. They are not warranted, nor does Timberline assume liability, if the buyer has misused the product in any manner, has failed to use the product in accordance with industry standards and practices, or has failed to use the product in accordance with instructions, if any, furnished by Timberline. Timberline s sole responsibility and the buyer s exclusive remedy with respect to the purchase of any product proved to Timberline satisfaction to be defective or nonconforming, is repair, replacement, or credit, in Timberline s sole discretion. No other warranty or representation is implied or expressed by Timberline for its products with respect to merchantability, fitness for a particular purpose or any other matter. Timberline shall not under any circumstances be liable for any incidental, consequential or compensatory damage arising from the use of, or in conjunction with its products, even if Timberline has been advised of the possibility of such damages. The maximum liability that can be assumed by Timberline for breach of warranty shall be the invoice price of the product. All claims must be brought within one (1) year of shipment, regardless of their nature. Components that are subject to normal wear and/or are scheduled for routine replacement within the warranty period, and/or parts that are subjected to effects of corrosion or deterioration by chemical or other action are excluded from the above warranty. Repair or replacement will not be made under warranty for malfunction because of inadequate facilities, operating conditions or utilities. Guarantees/Warranties on accessories and equipment included by Timberline from other manufacturers are limited to the guarantees given on such equipment by the respective manufacturers. SHIPMENTS All shipments are made F.O.B. Boulder, CO. Instruments and major components will be packed and shipped via surface, unless otherwise requested. Supplies and/or replacement parts are packed and shipped via UPS, UPS Blue, air parcel post, or parcel post, unless otherwise requested. DAMAGED SHIPMENTS The Interstate Commerce Commission has held that carriers are as responsible for concealed damage as for visible damage in transit. Unpack shipment promptly after receipt, as there may be concealed damage even though no evidence of it is apparent. When concealed damage is discovered, cease further unpacking of the unit involved and request immediate inspection by the local agent or carrier and secure a written report of the findings to support a claim. This request must be made within 15 days of receipt. Otherwise, the carrier will not honor the claim. Do not return damaged goods to the factory without first securing an inspection report and contacting Timberline for a return authorization number. FILING OF CLAIMS After a damage inspection report has been secured, Timberline will cooperate in supplying replacements and handling a claim that may be initiated by either party. RETURNS Timberline Instruments, Inc. tries to accommodate all requests for returns. Inspect shipment upon receipt and report shortages, incorrect or damaged materials to us immediately. Report shipping damage to the carrier. Damaged shipments must remain with the original packaging for freight company inspection. Products not supplied in accordance with your orders or products that are defective at the time you receive them are accepted for full credit. Products ordered in error are subject to a 15% restocking charge. Special or custom orders cannot be returned unless defective. All returned merchandise must be in unused, resalable condition, and must not consist of hazardous materials. No returns will be accepted more then 90 days after shipment for any reason. Before 90 days, no returns will be accepted without prior authorization. If it is necessary to return a product to us, please contact our customer service department to obtain a return material authorization (RMA) and shipping instructions. Timberline Instruments, Inc. - 8 - TL-105

When you call, be prepared to supply the information necessary for us to identify your order, including your company name, address, purchase order number/invoice number, shipping date, product description and catalog number. Write the RMA number on all shipping labels and correspondence about the shipment. Returns without this number will be returned to you collect. Be careful to address the shipment to the street address. Shipper will not deliver to our post office box numbers. We require that you prepay shipping costs; COD's will not be accepted. Returns must be made through a traceable carrier. Shipment of authorized returns should be made within 30 days of the issuance of RMA. If products are not returned within the time limit, the RMA may expire. Timberline Instruments, Inc. reserves the right to refuse any return or credit after a RMA has expired. Timberline Instruments, Inc. - 9 - TL-105

INDEX A accuracy... 3 actual temperature... 6 B band broadening... 4 C column compartment will drain... 5 corrosive or harsh organic liquids... 5 D drain... 5 H heat exchanger... 4 P peak broadening... 4 pre-column heat exchanger... 4 S set temperature... 6 stability... 3 switching valve... 4, 5 T temperature limit... 3 temperature, actual... 6 temperature,set... 6 thermal fuse... 3 W warm up time... 6 I injection valve... 4, 5 Timberline Instruments, Inc. - 10 - TL-105