HPLC Column Ovens and Temperature Controllers

Similar documents
Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

OPERATING MANUAL. EchothermJ HPLC COLUMN CHILLER/HEATER MODEL CO30. DOCUMENT NUMBER CO30-03 Revised February 10, 2010

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

300 series HPLC autosamplers

Precision Temperature Control. Pulse Free Pump. Column Oven. Superb Performance Ion Chromatography. Leak Detector. Modular Flexibility

TC-PLUS Thermal Cyclers

Advantages / Characteristics

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

A Chiller is equipment to control temperature of customers heating sources. Application Examples

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

Ingenieurbüro M.ZippererGmbH

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

Superior Temperature Control Equipment

ENVAIR lab CO2 Tri-Gas Incubator

vacuum FLOW support excellence experience

I/A Series 716C 1/16 DIN Temperature Controller

108A OTP1800. Grid Support. General Description

Customised HPLC Systems for Highest Performance

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Linkam Scientific Instruments

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Thermo Scientific Dionex Integrion HPIC System

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

Oakton TEMP 9500 Advanced Multiparameter Controller

Operator: Save these instructions for future use!

Huminator II. Precision Humidity Generator. ww.testo.in

MCR. Temperature Devices. ::: Intelligence in Rheometry

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Hotplates, Magnetic Stirrers and Stirring Hotplates

CALIDUS tm the Modular micro Gas Chromatograph

Model 1062 Environment Monitor

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

laundry Laundry dosing systems

Focus 4010\ Focus 4010 HT porcelain firing furnace

OptiCal Humidity and Temperature Calibrator User s Manual

VWR symphony CO 2 INCUBATORS

Temperature Controllers

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

FITOCLIMA 600 & 1200 PHARMA

PolyScience. Circulators. Constant Temperature Equipment. Remarkably Responsive TM

RS Pro Infrared Temperature Sensor

RIGID DC LIQUID CHILLER

KEM Scientific, Inc. Instruments for Science from Scientists

TORREY PINES SCIENTIFIC, INC.

BlueSpin Magnetic Hotplate Stirrer

Platelet bags constant shaking for long periods of time.

BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

Benchtop CO 2 Incubator. the Oasis 6400 series

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Flow Level Pressure Temperature. Rugged tactile response keys. Try the all new Fluidwell Configurator at:

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

15900 HVAC INSTRUMENTATION AND CONTROLS

Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

LAUDA Additional devices Immersion coolers, through-flow coolers, circulation heat exchangers

BD Viper Lysing Heater Manual (for BD Viper System)

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

931D Style B Process Gas Chromatograph

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

TL-105 COLUMN HEATER

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Analyze IT. Process Gas Chromatograph. PGC2000 Series

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

FITOCLIMA 600 & 1200 STABILITY

Laboratory thermostatic chambers

DGC-1000 DIGITAL GENSET CONTROLLER

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Operating Manual UV Monitor UVT 18

Waterbaths & Oilbaths

GMH 285 / GMH 285-BNC

Protect your research

TCC-34. Features: TISSUE CULTURE

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX

Product Manual SZ1145

portable gas analyser

Transcription:

HPLC Column Ovens and Controllers Improve your separation performance today! Accurate temperature control of your HPLC columns will improve the reproducibility of your results. Operating at increased temperatures provides better separation performance and reduced analysis time in most cases. Alternatively, you may need to chill your columns when using thermally sensitive compounds. Whatever your requirements, we can supply an HPLC column oven to improve your results! Stability HPLC Column Ovens exceptional value! A choice of quality column ovens offering The Stability HPLC column ovens are designed for applications requiring increased temperatures. In most cases, with higher temperature you will get: Better reproducibility Higher separation performance Reduced analysis time Easy to Use: The heated part of the oven is separate from the control unit, which allows you to easily install it into your chromatography configuration. It it also light enough to hang it directly on to a column! A Range of Sizes Available: The Stability ovens are available in three configurations: Stability Short for one 15cm column; Stability Single for one 25cm column; Stability Double for two 25cm columns Simple Control: To set the required temperature, simply adjust with the arrow buttons on the control unit and store. The Stability column ovens remember the set temperature even when switched off there is no need to keep setting the same temperature time after time. Safe: An independent safety circuit turns the heater off and sounds an alarm signal if the set temperature is exceeded by 10 C. Specifications Capacity: One 15cm column (Stability Short) One 25cm column (Stability Single) Two 25cm columns (Stability Double) Operating Range: Ambient to 99 C

Stability: Setting: Steps of 0.1 C Accuracy of Setting: ±0.5 C Heating Rate: 5 C/min Internal Oven Dimensions (W x H x D): 21 x 23 x 205mm (Stability Short) 21 x 23 x 310mm (Stability Single) 34 x 27 x 310mm (Stability Double) Control Unit Dimensions (W x H x D): 100 x 155 x 190mm Mass: 2.5kg (control unit) 100/115/230V AC (±10%), 50/60Hz. 50VA Stability Short HPLC Column Oven LH64000001 Stability Single HPLC Column Oven LH64000000 Stability Double HPLC Column Oven LH64000002 Stability Plus HPLC Column Oven Increase the temperature and increase separation performance! The Stability Plus HPLC column oven is designed for applications requiring increased temperatures. In most cases, with higher temperature you will get: Better reproducibility Higher separation performance Reduced analysis time Accurate Control: The oven is heated by an internal electrical heating element whilst a platinum (Pt) temperature sensor ensures a high precision temperature control. The integrated LCD continuously displays the current block temperature. Protects your Columns: A reversible thermal cut-out system is included to protect your columns from potentially damaging

temperatures. Should the temperature exceed that set by more than 10 C, the heater will automatically switch off and an audible alarm will sound. Specifications Capacity: One 25cm column, plus guard column Operating Range: Ambient to 99 C Stability: Setting: Steps of 1 C Accuracy of Setting: ±1 C Heating Rate: 2.5 C/min Dimensions (W x H x D): 490 x 100 x 180mm (external) 455 x 30 x 33mm (internal) Mass: 7.1kg 230V AC (±10%), 50Hz. 110VA Stability Plus HPLC Column Oven LH57000000 Ambient Plus HPLC Column Oven Precise...Reliable...Affordable Increase the accuracy and consistency of your chromatography with the Ambient Plus HPLC Column Oven. changes through the day and even draughts in your laboratory can affect your results. Get precise, repeatable results with uniform, controlled temperature. Uniform : All major elements columns, injector, precolumns are enclosed in the oven chamber. Constant temperature is maintained along entire length of fluid path. Mobile phase is used as the transfer medium so temperature is unaffected by flow rate.

Precise: is maintained within ; repeatable to ±0.1 C. Large Capacity: Holds up to six analytical or GPC columns. No need for special blocks or inserts. Specifications Operating Range: 10 C above ambient to 100 C Stability: Reproducibility: ±1 C Accuracy: ±2 C over entire range. The setpoint changes slightly depending on composition and mobile phase flow rate. Cutout: 118 C, self-resetting Stabilisation: 30mins to 100 C for "ready" at 2ml/min. For analyses requiring high precision, wait 30 minutes after the READY light illuminates before beginning an analysis. Recommended Flow Range: Up to 8ml/min Average Cooling Time: 30mins to 10 C above ambient at 2ml/min from 100 C (with cover off). Column Capacity: Up to three 3/8" x 30cm columns or four ¼" x 30cm columns Column Chamber Material: Anodised, solvent resistant aluminum Communications Remote Inputs: RS-232. 0-10V DC setpoint temperature voltage control. Remote Outputs: RS-232. Relay contact closure when oven is ready. The contact is rated at 0.25A maximum, 100V DC maximum, and 0.2Ω External Dimensions (W x H x D): 127 x 223 x 495mm Mass: 9.5kg 100-120V (single fused) or 220-240V (double fused) AC, 50/60Hz. 120W

Ambient Plus HPLC Column Oven, 120V LH200584 Ambient Plus HPLC Column Oven, 230V LH200585 Advance Compact HPLC Column Oven LH3080 Advance Professional HPLC Column Oven High Capacity Peltier Column Heater/Chiller Key Features: Large temperature range (5-85 C) Extremely high stability (±0.02 C) High reproducibility (±0.1 C) Accommodates 4 columns, with lengths up to 40cm Ample space for valves and injectors Automatic calibration RS232 interface Small footprint column compartment. Advanced Heating/Cooling System: The Advance Professional oven uses Peltier thermo-electric elements that provide both heating and cooling. Two-way forced air circulation guarantees perfectly even temperature distribution throughout the The temperature is controlled by Double-Sensor-Reference technology. This consists of two independent temperature sensors (one a Pt, the other laser trimmed) that are continually compared to a precision reference value. Simple to Use: Quickly set the temperature in Celsius or Fahrenheit using the handheld alphanumeric keypad. The LCD display shows both the set and actual temperatures. For more advanced control you can program the temperature over a period of time, either as a linear ramp function or in a series of steps. This can be done from either the keypad or from a computer via the RS232 interface. Auto-calibration: The oven performs a quick self-check and calibration procedure each time it is powered up. s can be manually corrected via the keypad but in addition to this, a full auto-calibration feature is included. Following the input of a special keypad combination, the oven will perform an 8-hour self-calibration and control routine. This will greatly assist you with your quality control procedures! Safety and Security: Integrated leak detection with adjustable sensitivity, audible warning signal and auto-switch-off are included as standard. To prevent damage to temperature sensitive columns you can also specify a maximum allowable temperature, monitored by two independent sensors.

Specifications Capacity: 4 columns, with lengths up to 40cm Ample space for valves and injectors Operating Range: 5-85 C Stability: ±0.02 C Reproducibility: ±0.1 C External Dimensions (W x H x D): 135 x 450 x 310mm Mass: 11kg 100-245V AC, 50/60Hz. 100W Advance Professional HPLC Column Oven LH5480 Model 7990 HPLC Column Heater Ultra Compact HPLC Column Heater now with serial RS-232 control Accurately controls temperature from 30-75 C Column oven compartment suspends from stainless steel HPLC tubing Compact controller can control one or two ovens Large easy to read display Requires virtually no bench space Choice of oven units available Accurate and Economical: Developed with the cost conscious laboratory in mind, the Model 7990 compact HPLC column heater provides a cost effective way to control your column temperatures. Accurate control of HPLC column temperatures is becoming increasingly important in today's regulatory climate. Unique Suspended Design to Save Bench Space: The column heater unit is designed to hang from your existing stainless steel HPLC tubing. The separate control unit can be placed on top of existing instrumentation. Coupled with the fact it can control up to two independent heater units, this lets you save valuable bench space.

Specifications Operating Range: 30-75 C Stability: Reproducibility: Accuracy: 0.5 C ±0.5 C Cutout: 90 C Controller Dimensions (W x H x D): Column Oven (W x H x D): Mass (controller): Mass (oven): 118 x 195 x 185mm 365 x 37 x 40mm (short) 415 x 37 x 40mm (long) 2.3kg (single channel) 2.8kg (dual channel) 0.51kg (short) 0.61kg (long) 110/220V AC, 50/60Hz. 100W Model 7990 HPLC column heater, single output controller with short column unit 7990R-1-S Model 7990 HPLC column heater, single output controller with long column unit 7990R-1-L Model 7990 HPLC column heater, dual output controller with 2 short column units 7990R-2-SS Model 7990 HPLC column heater, dual output controller with long and short column units 7990R-2-SL Model 7990 HPLC column heater, dual output controller with 2 long columns 7990R-2-LL Model 7995 HPLC Column Heater/Chiller

Mini HPLC column heater/chiller Accurately controls temperature from 10-50 C Column oven compartment suspends from stainless steel HPLC tubing Serial control option via data system or PC Requires virtually no bench space Very cost-effective Choice of oven units available Unique Suspended Design to Save Bench Space: The Model 7995 heater/chiller is based on the popular Model 7990 column heater, but adds sub-ambient temperature control. As with the 7990, the column heater unit is suspended from your existing stainless steel HPLC tubing. The separate control unit can be placed on top of existing instrumentation, saving valuable bench space. Full RS-232 Control: The unit includes serial computer control that gives you the option of full system integration. The command set includes remote temperature setting, monitoring, step transition and ramping. These can often be handled by your existing data system. Additionally, Windows-based software is available to provide remote control and data logging functions. Specifications Operating Range: 10-50 C Stability: Reproducibility: 0.5 C Accuracy: ±0.5 C Cutout: 75 C Controller Dimensions (W x H x D): 118 x 195 x 185mm Column Oven (W x H x D): 265 x 90 x 40mm (short) 415 x 90 x 40mm (long) Mass (controller): 3.0kg Mass (oven): 0.8kg (short) 1.2kg (long) 110/220V AC, 50/60Hz. 100W

International Co. for Lab. Instruments 45 Shalhoub st. Ain Shams, Cairo, Egypt Post Code 11311 +202 24916139 or +202 24916139 +202 24953441