INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL TANKBUDDY IMPORTANT SAFETY INFORMATION

Similar documents
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

SMARTBOOST IMPORTANT SAFETY INFORMATION

PRO SERIES IMPORTANT SAFETY INFORMATION

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Eemax, Inc. Electric Tankless Water Heaters

Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free compliance.

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Installation and Operation Guide

Installation and Operation Guide

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL TANKLESS WATER HEATER

Smart Water Heater Controller

Installation and Operation Guide

OPERATING AND INSTALLATION MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER

OPERATING AND INSTALLATION MANUAL

OPERATION & INSTALLATION MANUAL

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL JTX / JHX TANKLESS BOOSTER HEATER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL JTX TANKLESS BOOSTER HEATER ELECTRIC HEATER COMPANY

INSTALLATION GUIDE AND OWNER S MANUAL

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

Dishwasher Installation Manual

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

EEMAX ProAdvantage Series 1

QUICK START GUIDE 04 WARNING 05 PACK CONTENTS 05 TECHNICAL SPECIFICATIONS 05 ELECTRICAL REQUIREMENTS 05 WIRING DIAGRAM 07 INSTALLATION OPTIONS

Installation & Operating Guide

SAVE THESE INSTRUCTIONS

Flow Factor ~

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Instant Hot Water Dispenser Owner s Manual

Installation Instructions

Top Control Dishwasher

Installation Instructions

EEMAX SERIES-TWO WATER HEATERS

OPERATION AND INSTALLATION

TABLE 1 Electrical Specifications

SAVE THESE INSTRUCTIONS

EcoSmart Troubleshooting Guide

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

TABLE 1 Electrical Specifications. Phase

INSTALLATION GUIDE AND OWNER S MANUAL. AccuMix II ELECTRIC INSTANTANEOUS WATER HEATER WITH ASSE 1070 APPROVED MIXING VALVE

WAIWELA SERIES-TWO WATER HEATERS

USE & CARE MANUAL. Non-Metallic Electric Water Heater. Residential Electric Models Gallon Point-of-Use

EEMAX THREE MODULE, SINGLE PHASE WATER HEATERS

I<enmore Elite. instructions dlnstallation. Installation Guide Instrucciones de Instalaci6n. English / Espafiol/Frangais

EEMAX HOME ADVANTAGE

Point-of-Use Water Heater Owner s Manual. Installation, Care & Use

Installation & Operation Manual Models:

GEOTHERMAL STORAGE TANKS

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Installation Instructions

INSTANT-FLOW C-MICRO WATER HEATER

TRONIC 6000C. Tankless electric whole house water heaters. Models: WH17 / WH27. [en] Installation Manual and Operating Instructions

Installation Instructions

EEMAX PROADVANTAGE ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL

INSTANT-FLOW C-MICRO WATER HEATER

Installation & Operating Guide

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

Installation Instructions

Installation Instructions Built-In Dishwasher

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Model TWBS.EW.H Tempered Water Blending System

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

INSTANT HOT WATER DISPENSER

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

ERGOMAX 7 INSTALLATION

IMPORTANT SAFETY INFORMATION READ ALL...

Installation S

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Dishwasher Installation Instructions DW 24XT/DW 24XV

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Crown Boiler Company

Installation Instructions PRO SERIES

INSTALLATION INSTRUCTIONS FOR MULTI-UNIT RESIDENTIAL APPLICATIONS INSTALLATION INSTRUCTIONS ARE PER UNIT MODELS: RS-502C, RS-503C, RS-702C, RS-703C

Parts & Material Included

Installation Instructions

Installation Instructions

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Installation S

Installation S

ECO SPA & POOL OWNERS MANUAL & INSTALLATION GUIDE

Installation Instructions

OPERATIONS MANUAL 5 LITER LPG GAS TANKLESS WATER HEATER C AMPER SERIES

Installation Instructions

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

GOLD Plus 30/40/60/80

INSTALLATION AND SERVICE MANUAL

Installation Instructions

Commercial Electric Water Heater USE & CARE MANUAL

SHC 2.5 MINI-TANK ELECTRIC WATER HEATERS CALENTADORES DE AGUA ELÉCTRICOS DE MINI-TANQUE CHAUFFE-EAU ÉLECTRIQUES À MINI-RÉSERVOIR

Transcription:

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL TANKBUDDY IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions should always be followed. Under no circumstance should you attempt to clean, install, inspect, repair, disassemble or otherwise service this water heater, without first shutting off all power to the unit directly at the breaker box. SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING. WE RECOMMEND THAT THIS PRODUCT BE INSTALLED BY A QUALIFIED HOMEOWNER. IF FURTHER ASSITANCE IS NEEDED, A LICENSED AND QUALIFIED PLUMBER AND ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE, PROVINCIAL, AND LOCAL PLUMBING AND ELECTRICAL CODES SHOULD BE HIRED. PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION & USE. FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE, SERIOUS INJURY, OR DEATH. This manual should be shown to all members of the household who plan to use this unit, and be retained for future reference. Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free compliance. Rev E 3/4/2016

ABOUT YOUR TANKBUDDY Congratulations on the purchase of your Eemax TankBuddy! The TankBuddy is a device that extends the usable hot water from your existing hot water storage device, while maintaining the existing electrical power infrastructure. TECHNICAL SPECIFICATIONS Voltage Max Amperage Max Power Rating 240 VAC 30 Amps 7.2 kw Pre-Set Outlet Temperature 120 F Activation Temp Range Outlet Temperature Range Activation Flow Rate 80-130 F 80-140 F 0.3 GPM To get the best performance and energy savings from your TankBuddy, it is important that it be installed in accordance with our instructions and the electrical and plumbing codes applicable to your area, and that you read this manual thoroughly for important operating instructions and tips. If you have questions at any time, please contact Eemax directly at: Eemax Inc. 400 Captain Neville Drive, Waterbury, CT 06705 Toll Free: 1-800-543-6163, or 203-267-7890 Fax: 203-267-7975 info@eemaxinc.com CONTENTS 1. BEFORE INSTALLATION 2. SELECTING A LOCATION TO INSTALL 3. SETTING UP TO INSTALL 4. PLUMBING INSTALLATION 5. ELECTRICAL INSTALLATION 6. GENERAL OPERATING INSTRUCTIONS 7. MAINTENANCE 8. TROUBLE SHOOTING GUIDE 9. USER INTERFACE 1

1- BEFORE INSTALLATION PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION & USE. FAILURE TO FOLLOW INSTRUCTIONS COULD CAUSE PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR DEATH. By installing this product, you acknowledge the terms of the manufacturer s warranty. Once the heater is installed, do not return product to the place of purchase. If you have any questions regarding the warranty or product return policies, please contact us at 1-800-543-6163. Inspect all components. The contents of your box should include the following components: TankBuddy Unit ½ Ferrule (2x) ½ Nut (2x) ⅝ Tube to ¾ NPT Female Adapter (1x) Push-to Connect Fitting (With ½ Copper Pipe Sample) (2x) Cable Clamp (2x) Wire Nuts (1x) Pigtail Cord (1x) What you will need to install: Phillips Head Screwdriver Flat Head Screwdriver Pipe Cutter Adjustable Wrench Teflon Tape Tape Measure/Ruler Pencil (recommended for marking measurements when cutting pipe) Needle-Nose Pliers (not required but may be beneficial) 2- SELECTING A LOCATION TO INSTALL This product is designed to be installed indoors only, in series with your pre-existing tank water heater. DO NOT install this product in a location where it may be subject to freezing temperatures. If the water inside your unit freezes, it can cause severe and permanent damage that is not covered under your warranty. DO NOT locate the water heater in a location that is difficult to access. SCALD RISK: Make sure that the water heater and hot water outlet pipe are out of the reach of children so they cannot tamper with the temperature controls or injure themselves by touching the hot water outlet pipe. The outlet water pipe can get very hot. This product does NOT require venting. Avoid installing your unit in a location prone to excessive humidity, moisture, or dust, or in an area where it may be splashed with water or other liquids. DO NOT install under water pipes or air conditioning lines that might leak or condense moisture that could then drip onto the heater. DO NOT install above electrical boxes or junctions. If you plan to install your water heater on a second floor or in a heated attic space, make sure that you follow all code requirements for such installations as required for your area. You can install an active water leak detector and shutoff valve designed to turn off your water supply in the event that a leak is ever detected. 2

3- SETTING UP TO INSTALL Recommended Clearances: At least 14 inches from above the existing tank heater to the next obstruction 6 inches in front of and to the sides of the TankBuddy, for service maintenance Pre-Mounting Steps 1. SHUT OFF ELECTRICITY ON YOUR CIRCUIT BREAKER BEFORE PROCEEDING TO ANY FURTHER INSTALLATION STEPS. 2. Make sure there is at least 14 inches of straight pipe clearance above the tank heater. This is the required room in order for the unit to effectively connect in series with the tank and outlet pipe. IF SPACIAL ISSUES ARISE, OR IF THE COPPER PIPE IS NOT STRAIGHT (ABNORMAL PIPING THAT IS NOT STRAIGHT), AN ADDITIONAL PLUMING HOSE MAY NEED TO BE USED. 3. Close the supply water valve to the tank heater, located in most cases above the tank heater on the cold water inlet side. You must do this to drain your system. 4. Open the drain valve of the water tank to let the tank completely deplete of water. The drain valve is usually located near the bottom of the tank. 5. Drain the water from all existing hot water pipes by first opening all hot water faucets of any kind in the house. Leave the faucets open until plumbing installation is complete. If water does not stop flowing, check to make sure the inlet water to the tank heater has been completely shut off. 6. Assess your plumbing system before you cut the pipe possible plumbing layouts on the following page CUTTING THE PIPE IS A CRITICAL STEP. IT IS IMPERATIVE YOU REFER TO THE GUIDE ON THE FOLLOWING PAGES FOR CLEAR INSTRUCTIONS ON HOW TO CUT THE HOT COPPER PIPE. Note: If you do not have any of the following plumbing layouts, we recommend you then hire a licensed and qualified plumber to perform this portion of the installation. 3

Possible Pre-Existing Plumbing Layouts At least 1 ½ of vertical pipe movement At least 1 ½ of vertical pipe movement Hot Water Copper Pipe Hot Water Copper Pipe Irremovable or essential union (Can be variety of fittings) Hot Water Outlet Connection Fitting (Can be variety of fittings) Hot Water Outlet Connection Fitting (Can be variety of fittings) Layout A At least 14 inches of straight pipe above tank At least 1 ½ of vertical pipe movement (ability to raise pipe) Turn to page 5 Layout B At least 20 inches of straight pipe above tank At least 1 ½ of vertical pipe movement (ability to raise pipe) Irremovable or essential union used in plumbing Turn to page 6 No vertical movement (Pipe is completely restricted or braced) Hot Water Copper Pipe Layout C At least 14 inches of straight pipe above tank No vertical movement of pipe (Pipe is completely restricted or braced) Turn to page 7 Hot Water Outlet Connection Fitting (Can be variety of fittings) 4

Cutting the Copper Hot Water Pipe Layout A Please follow all pre-installation instructions carefully. We recommend that this product be installed by a qualified homeowner. If further assistance is needed, a licensed and qualified plumber in accordance with all applicable national, state, provincial, and local plumbing codes should be hired. 1. Locate the hot water outlet connection on your pre-existing water tank. On the copper pipe, mark with a pencil 2 inches above the topmost point of the hot water outlet connection fitting. 2. Using a pipe cutter, cut the hot water copper pipe at this 2-inch mark (Cut A), being as accurate as possible. Refer to Figure A. Once accomplished, unscrew the original connection fitting from the outlet thread of the tank. 3. On the now exposed tank outlet thread, screw on the Female NPT Adapter (reference pg. 9), tightly securing this connection. Wrap the thread 2-3 times with Teflon Tape to seal the connection and prevent leaks. 4. Now from the in-place Female NPT adapter, measure upwards EXACTLY 11 ⅛ inches. Refer to Figure B. Mark this on the copper pipe with a pencil. IT IS IMPERATIVE THAT ACCURACY BE USED DURING THIS STEP. CUTTING THE PIPE TOO MUCH WILL PREVENT A SECURE CONNECTION FROM TAKING PLACE. 5. Cut the pipe at the 11 ⅛ inch mark (Cut B), taking extreme care for accuracy. If the installer is less experienced or unsure, it is advised to cut the pipe slightly below the 11 ⅛ inch mark. It is safer to cut too little and correct a mistake than to cut too much. 6. Secure a Push-to-Connect fitting onto the hanging copper pipe, making sure there are no stray or jagged pieces of copper stemming from the pipe. Make sure the Push-to-Connect fitting is pushed as far up as possible onto the copper pipe, fully sealing the connection. 7. Proceed to Plumbing Installation on page 8 with reference guide on page 9. Hot Water Copper Pipe Cut B. Cut A. 11 ⅛ 2 Hot Water Outlet Connection Fitting (Can be variety of fittings) ¾ Female NPT to ⅝ Tube Adapter Figure A. Figure B. 5

Cutting the Copper Hot Water Pipe Layout B Please follow all pre-installation instructions carefully. If further assistance is needed, a licensed and qualified plumber in accordance with all applicable national, state, provincial, and local plumbing codes should be hired. 1. Locate the irremovable or essential union on the hot water pipe. On the copper pipe, mark with a pencil 2 inches above the topmost point of the irremovable/essential union. Refer to Figure C. 2. Using a pipe cutter, cut the hot water copper pipe at this 2-inch mark (Cut C), being as accurate as possible. Refer to Figure C. Do not remove any pipe yet, simply perform cut C. 3. Now measure upwards EXACTLY 12 ½ inches from cut C. Refer to Figure D. Mark this on the copper pipe with a pencil. IT IS IMPERATIVE THAT ACCURACY BE USED DURING THIS STEP. CUTTING THE PIPE TOO MUCH WILL PREVENT A SECURE CONNECTION FROM TAKING PLACE. 4. Cut the pipe at the 12 ½ inch mark (Cut D), taking extreme care for accuracy. If the installer is less experienced or unsure, it is advised to cut the pipe slightly below the 12 ½ inch mark. It is safer to cut too little and correct a mistake than to cut too much. 5. Secure the Push-to-Connect fittings onto BOTH exposed ends of the copper pipe, making sure there are no stray or jagged pieces of copper stemming from the pipes. Make sure the Push-to-Connect fittings are pushed as far as possible onto the copper pipe, fully sealing the connection. 6. Proceed to Plumbing Installation on page 8, with reference guide on page 10. Hot Water Copper Pipe Cut D. 2 Cut C. 12 ½ Irremovable or essential union (Can be variety of fittings) 2 Cut C. Hot Water Outlet Connection Fitting (Can be variety of fittings) Irremovable or essential union Figure C. Figure D. 6

Cutting the Copper Hot Water Pipe Layout C Please follow all pre-installation instructions carefully. We recommend that this product be installed by a qualified homeowner. If further assistance is needed, a licensed and qualified plumber in accordance with all applicable national, state, provincial, and local plumbing codes should be hired. This set-up addresses the issue of not having free space to vertically move the hot water pipe up in order to make a secure connection. This typically occurs if there is very low ceiling height or the copper pipe is braced or restricted. In order to install your unit, you will need to purchase an intermediate hose. We recommend using a ¾ Repair Hose Push Fitting. This type of hose has Push-to-Connect fittings on either side, and can be used efficiently for this application. Hoses such as the one shown can be purchased at a low cost at most home center stores. An alternative recommendation is to purchase a water heater installation kit. This could also help with the installation process such as Layout C. A kit such as the one shown can be purchased at a low cost at most home center stores. This method of installation requires more experience and judgment from the homeowner, because each household may have a moderately different layout in this situation. For further installation assistance, please call or email our customer service and technical support team for any help you may need. Toll Free: 1-877-474-6473, or 305-623-7900 support@ecosmartus.com 7

4- PLUMBING INSTALLATION Please follow all plumbing instructions carefully. We recommend that this product be installed by a qualified homeowner. If further assistance is needed, a licensed and qualified plumber in accordance with all applicable national, state, provincial, and local plumbing codes should be hired. Plumbing Installation Instructions Please see installation diagrams on the following pages for visual guidance. STEP 1: Using the corresponding fittings for which layout was used, connect the HOT WATER outlet from your water tank to the INLET thread located on the bottom side of the TankBuddy when facing the unit. Use the nut (B) and ferrule (C) to secure the connection. Do not over tighten the compression nuts, which may cause the ferrules to crack and lead to a leak. STEP 2: Using the PUSH-TO-CONNECT fitting (F), connect the HOT WATER copper pipe line to OUTLET thread located on the top side of the unit. Use the nut (E) and ferrule (D) to secure the connection. STEP 3: Close the tank drain valve. Make sure at least one warm water faucet is open in the house. Re-open the water supply valve on the cold water copper pipe. You know the tank is full when water is running out of any open faucet in the house. FAILURE TO FOLLOW THESE STEPS WILL CAUSE WATER TANK DAMAGE. STEP 4: After tightening all fittings, open several hot water faucets and allow un-heated water to run though the water heater for at least 2 to 3 minutes. This process purges all the air from the water lines and MUST be performed prior to turning on the power at the unit. FAILURE TO FOLLOW THIS STEP CAN CAUSE PERMANENT DAMAGE TO THE HEATING ELEMENTS. If any maintenance is performed on the water heater or the home s plumbing system that may introduce air into the plumbing pipes, it is important to turn the power off to the water heater and purge the air out of the lines before allowing the unit to power up. STEP 5: Carefully inspect all connections, unions, and the pressure relief valve (if installed) for leaks. STEP 6: TURN OFF ALL FAUCETS BEFORE PROCEEDING TO ELECTRICAL INSTALLATION. 8

Plumbing Installation Visual Guidance Layout A Existing Household Plumbing.875 / ¾ Copper Tube F. Push-to-Connect Fitting Step 2 E. D. ½ Nut ½ Ferrule Step 1 C. B. ½ Ferrule ½ Nut A. ¾ Female NPT to ⅝ Tube Adapter Existing ¾ Male NPT From Tank (OUTLET SIDE OF TANK) 9

Plumbing Installation Visual Guidance Layout B Existing Household Plumbing.875 / ¾ Copper Tube F. Push-to-Connect Fitting Step 2 E. D. ½ Nut ½ Ferrule C. B. ½ Ferrule ½ Nut Step 1 F. Push-to-Connect Fitting Existing Household Plumbing.875 / ¾ Copper Tube 10

IMPORTANT NOTES: 1. This unit should not require soldering any pipes for installation. Heat from soldering may damage the flow sensor in the unit. 2. This unit is equipped with both computer-controlled and electro-mechanical auto resetting thermostat switches for high-limited temperature protection. Since this product does not use a storage tank, the use of a temperature pressure relief valve (T&P) is not required for most installations. UL Standard 499 does NOT require that a pressure relief valve be used. However, a T&P valve may be required to meet installation codes in your area. If one is required, install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater. When connecting to Flex or High Temperature CPVC pipe, we recommend that a T&P valve be used for added safety. Please note: Installations in the Commonwealth of Massachusetts and State of Kentucky require a pressure relief valve. Please check your local installation codes for any special requirements. 3. The maximum operating water pressure is 150 PSI. If the water pressure is higher, a pressure reducing valve must be installed on the main incoming water supply line prior to installing the unit. 4. When connecting the inlet water pipe to the unit, make sure to use a wrench to hold the unit s connection, and another wrench to tighten, so the flow sensor on the unit is not loosened or damaged. Serious internal damage to the water heater can occur if the inlet or outlet connections are over tightened or if solder connections were made. 5. We recommend that a manual shut-off valve (ball valve) be installed on the inlet and outlet of the water heater so there is a convenient shut-off point available in the event that future maintenance or servicing is required. Before connecting pipes to the water heater, it is extremely important to flush the lines to eliminate all plumbing paste or residue in the lines caused by any brazing or soldering. We recommend that all the water pipes or hoses within 3 feet of the inlet and outlet connections be rated for high temperature applications with a 150 F minimum. 11

5- ELECTRICAL INSTALLATION We recommend that this product be installed by a qualified homeowner. If further assistance is needed, a licensed and qualified electrician in accordance with all applicable national, state, provincial, and local electrical codes should be hired. As with all electrical appliances, under no circumstances should you attempt to install, repair or disassemble this water heater without first shutting off all power to the unit directly at the fuse or breaker box. Make sure to shut off all breakers. SERIOUS BODILY INJURY OR DEATH CAN OCCUR IF YOU IGNORE THIS WARNING. All wiring (wire gauge) and circuit protection (breakers) must comply with the U.S. National Electrical Code (NEC) in the USA, or the Canadian Electrical Code (CEC) in Canada. Failure to do so could result in property damage and/or personal injury, and void your warranty. Note: the Canadian Electrical Code generally requires that all supply wires and corresponding circuit protection used for domestic hot water heating and hydronic heating applications be sized to a minimum of 125% of the maximum current rating of the heater (see model specifications below for details). Before installing this product, ensure that the home has sufficient electrical power available to handle the maximum amperage load of the applicable model. TURN OFF THE ELECTRICAL POWER BEFORE PROCEEDING. Electrical Installation Instructions STEP 1: Making sure all electrical power is shut off, remove the black, red, and ground wires from the existing tank heater coming from the circuit breaker. These wires will now go into the TankBuddy through the hole in the unit s back plate (see wiring diagram and Connection Reference 1 on the subsequent pages). STEP 2: Using a suitable wire gauge that meets all applicable electrical codes for the size of the breakers used, run Line 1 (black wire), Line 2 (red wire), and ground (green wire) from the home s main breaker panel to the TankBuddy water heater, through the back plate hole. This is connection reference 1, specified on page 14. Note: A separate ground conductor for each incoming circuit is required. STEP 3: Connect the supplied pigtail cord to the TankBuddy. See Connection Reference 2 on page 15. STEP 4: Now connect the wires included with the TankBuddy (pigtail cord stemming from the unit) to the existing tank heater. The black, red, and green (ground) wires should all have secure connections. MAKE SURE THESE CONNECTIONS ARE IN AN ENCLOSED AREA. EXPOSED CONNECTIONS CAN LEAD TO SERIOUS INJURY OR DEATH. STEP 5: DOUBLE CHECK the electrical connections to make sure they are correct and that all wire connections are tight and secure. Also confirm that the correct breaker size and wire gauge has been used and confirm that the unit has been connected to a ground in accordance with applicable codes. STEP 6: Confirm that all the air has been purged from the water lines prior to turning on power to the unit. Refer to STEP 4 in the plumbing installation section. CAUTION: Ensure that you have made the correct connections. You must follow the wiring connection as shown to ensure the proper operation of the unit. If you mix up one set of wires with another, the unit will not operate correctly even though it turns on and otherwise appears to function properly. 12

Electrical Wiring Diagram Normal Tank Configuration: TankBuddy and Electric Tank Configuration: Connection Reference 1, shown on page 14. Connection Reference 2, shown on page 15. 13

Connection Reference 1 Connecting Lines 1 & 2 from the circuit board (existing service) to the TankBuddy : 1. Remove the control knob from the unit, then remove the cover of the unit. Two screws (located on the side of the unit) must be removed in order to do this. 2. For this step, if the leads from the breaker are wrapped in a common household cable jacket, make sure the ends of the leads are exposed from the external jacket for at least 10 inches. Strip back 3/8 to bare copper on L1 & L2. Cable Clamp Lines 1 & 2 and ground (from the circuit breaker) will be connected to the TankBuddy s inner terminal block. Make sure to thread these lines into the heater from the backside via the back plate hole, using the supplied cord grommet. Connect Line 1 (black) to the L1 labelled wire terminal, and Line 2 (red) to the L2 labelled wire terminal, using a flathead screwdriver to secure the Wire Nut terminal. Using a supplied wire nut, connect the circuit breaker ground wire to the green ground wire stem already inside the unit, which will be exposed. Twist wires together, then twist the wire nut with both wires inside to secure the connection. L1/L2 Terminals Back Plate Hole (Installer must secure cable clamp here) 3. Tighten the connections on the terminal block with a flathead screwdriver. MAKE SURE WIRES ARE INSERTED ALL THE WAY IN THE TERMINAL, AND THAT THE SCREWS SECURING THE CONNECTION ARE TIGHT AND SECURE. FAILURE TO DO THIS WILL CAUSE HEATER MALFUNCTION. Also, make sure that the wire insulation is not inserted into the terminal block as this will inhibit good electrical connection. 4. Proceed to Connection Reference 2 on following page. 14

Connection Reference 2 Connecting the pigtail cord to the TankBuddy : 1. The pigtail cord should be partially attached to the unit through the ground connection. With the cover off, you should see an exposed red wire and black wire coming from the pigtail, on the end that s inside the unit. Connect the red wire to the left-most terminal, and the black wire to the right-adjacent terminal. 2. Tighten the connections on the terminal block with a flathead screwdriver. MAKE SURE WIRES ARE INSERTED ALL THE WAY IN THE TERMINAL, AND THAT THE SCREWS SECURING THE CONNECTION ARE TIGHT AND SECURE. FAILURE TO DO THIS WILL CAUSE HEATER MALFUNCTION. Also, make sure that the wire insulation is not inserted into the terminal block as this will inhibit good electrical connection. 3. Replace the unit cover, screws, and control knob. 15

6- GENERAL OPERATING INSTRUCTIONS Operating your new unit is very similar to using any traditional water heating system. However, it is very important that you carefully read all of the set-up procedures and operating instructions and tips to ensure the maximum performance and energy savings from your new water heater. We recommend that all members of the household read these General Operating Instructions. How your new unit works: The TankBuddy combines with the traditional hot water tank to provide an extremely effective and efficient way of heating your home. The unit reads the temperature coming out of the tank, and will turn on if the water drops below a set temperature, which you can set. The booster will keep the water at the desired temperature, another limit which you can set. 7- MAINTENANCE To ensure maximum performance of your unit and to reduce the risk of a water leak, we recommend the following maintenance: You should inspect the connections on the inlet and outlet of the unit at least on an annual basis for any signs of damage or failure. Any signs of damage, cracks, leakage or weakness should be addressed. Take care not to over-tighten the connections. Serious internal damage to your water heater can occur if you over-tighten the water heater connections at the unit. IMPORTANT NOTES: As with all electrical appliances, under no circumstances should you attempt to install, repair or disassemble this water heater without first shutting off all power to the unit directly at the fuse or breaker box. SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING. When any maintenance is performed on the unit or the home s plumbing system that may introduce air into the plumbing pipes, it is important to turn the power off to the water heater and purge the air out of the lines before allowing the unit to power up. FAILURE TO DO SO COULD CAUSE PERMANENT DAMAGE TO THE HEATING ELEMENT AND VOID YOUR WARRANTY. If you have a water supply with a high level of mineralization (hard water), you should increase the frequency of your maintenance. Remove element and inspect for scale build up soak in vinegar or deliming solution until scale is removed, typically within a few hours. 8- TROUBLE SHOOTING GUIDE Are you having problems with your water heater? Please call or email our customer service and technical support team for any help you may need. TOLL FREE 1-800-543-6163 info@eemaxinc.com 16

The following table represents some of the most common technical support questions we receive. Before calling us, please read thoroughly to see if your question or problem is addressed. PROBLEM POSSIBLE CAUSE SOLUTION Unit is not heating at all (water is flowing but the unit is not heating at all the outgoing water temperature is the same as my cold water supply) and/or the digital display does NOT light up. Unit is not heating at all (water is flowing but the unit is not heating at all - the outgoing water temperature is the same as my cold water supply) The digital display DOES light up. Unit is heating but the water temperature is not hot enough. No power or incorrect wiring. Internal part failure. Internal part failure. Flow rate is too low / water pressure is too low* Activation temperature too low User temperature setting too low. Voltage less than 240 volts. Make sure the breakers at main electrical panel are ON. You may have a faulty breaker or unit may be wired incorrect. Refer to page 13 for proper wiring layout. Please call us for technical assistance. Please call us for technical assistance. Your water heater has an activation flow rate of approximately 0.3 GPM. If your water flow rate is less than this level, your unit will not activate. Increase the flow rate. The water heater will turn on when the temperature of the water at the inlet of the TankBuddy falls below the activation temperature (when the tank is not providing hot water). Increase activation temperature. Turn up the temperature setting on the unit. The heating elements on your unit are designed for 240 volts. When use with a lower voltage, they produce less heating power. The water temperature at my faucet is less than the temperature setting of my water heater. Mixing too much cold water Voltage less than 240 volts. You may have an anti-scald feature on your faucet that is mixing cold water. These types of faucets can usually be adjusted to reduce the amount of cold water mixed. Also, your tank may be completely out of hot water and is mixing cold water. Give the tank time to recover or reduce the amount of water you are using. The computer chips in your unit are programmed with the expectation that your incoming line voltage is 240 volts. If you have less than 240 volts, it may affect the reading on your unit s digital display and cause it to read slightly higher than the actual output temperature. To compensate for this, increase the setting on your unit if you need / want hotter water. Anti-Scald pressure/balancing valve or tempering valve. Your faucet may have an anti-scald feature or a tempering valve that automatically mixes cold water even when you turn your control lever or handle to full hot. These devices are usually adjustable so you can turn off the cold mix completely. You can compensate for this by increasing the setting on your unit if you need/want hotter water. Pre-existing water tank is not heating. Thermal loss due to long pipe run Incorrect wiring. As the hot water from the unit runs through the hot water delivery system to your faucet, some heat will be lost especially if it has long distance to travel or the pipes are cold. This is normal. You can compensate for this by increasing the setting on your unit if you need/want hotter water. The unit may be wired incorrectly. Refer to page 13 for proper wiring layout. Relay switch is defective. Please call us for technical assistance. Unit displays 999 as inlet and/or outlet temperature Thermistor on corresponding channel is defective The unit may be wired incorrectly. Refer to page 13 for proper wiring layout. 17

9- USER INTERFACE TankBuddy Features List of Menu Options Provided by the Software (Clarified Below and on Following Page): Inlet/Outlet Temperature Reading Active Unit in Operation Activation Temperature Max Temperature Software Version Primary Menu Cycle Screens Turn the control knob in either direction to cycle through menu options. Inlet/Outlet Temperature Reading The temperature of the water going in and out of the TankBuddy can be observed from this display. IN 71 F OUT 69 F Active Unit in Operation This screen will tell the user which heating unit is operating at that given point in time. It will either be the pre-existing water tank ( TANK ) or the TankBuddy ( UNIT ). TANK OFF UNIT ON Flow The flow screen will tell the user the amount of water that is flowing through the unit in gallons per minute. FLOW 0.00 GPM Load Factor Here you can see how hard your TankBuddy is working. PWM 88% Clock Set the time here (HOURS:MINUTES:SECONDS). Press the knob to cycle through hours, minutes, seconds and turn the knob to adjust the number. CLOCK 01:23:57 18

Active Time The active time screen will display how long the unit has been actively heating water. The time is displayed in HOURS:MINUTES ACTIVE 1:12 Total Time This screen tells the user the total amount of time the unit has been on in it s lifespan TOTAL 12345:12 Setup If the knob is pressed once on this screen, the user will be taken to all the booster heating set up interface. ALL OF THE FOLLOWING SET UP CYCLE SCREENS WILL ORIGINATE FROM PRESSING THE KNOB ONCE ON THIS DISPLAY. SETUP ENTER TankBuddy Built-In Freeze Protect Feature (Select Models Only) While the TankBuddy is in Vacation Mode, if the temperature read at the inlet of the TankBuddy unit drops below 60 F, the tank will automatically power on to prevent the nearby pipes from freezing and potentially bursting. Once the temperature at the inlet of the TankBuddy exceeds 60 F again, the tank will power back off. TankBuddy Set Up Menu Cycle Screens Turn the control knob in either direction to cycle through menu options. Activation Temperature The first heater setting is the activation temperature. If the unit reads an inlet temperature that below the activation temperature, the unit will turn on. For instance, if the activation temperature is 115, and water coming into the unit is below 115, the unit will turn on. To change this setting, press the knob once, and a * will appear on screen. Turn the knob to adjust temp, and then press the knob again to save the setting. ACTIVATE * 115 F ACTIVATE 115 F Max Temperature Here you can set the maximum temperature you want the TankBuddy to heat the water up to. To change the set temperature, press the knob once, and a * will appear on screen. Turn the knob to adjust temperature, and then press the knob again to lock in the setting. MAX TEMP * 120 F MAX TEMP 120 F 19

Software Version Here you can view the heater software version (useful for troubleshooting). VERSION 210 Exit If knob is pressed once on this screen, the user will be taken back to the primary menu screen cycle. SETUP EXIT 20

Eemax Inc. 400 Captain Neville Drive, Waterbury, CT 06705 Toll Free: 1-800-543-6163, or 203-267-7890 Fax: 203-267-7975 info@eemaxinc.com 22