Technical manual WATERFLASH 2003 General presentation WATERFLASH 2003 is only on the range equiped with a watertight motor, available for public installation, hotel and everywhere with a humidity risk. WATERFLASH 2003 is composed by : - a ceramic vitrified pan, - available in 10 colors, - equiped with reverse operation. ACTANA Commercial and manufacture 19, rue de l industrie - ZI «La Petite Motte» 77220 TOURNAN EN BRIE Tél. :00.33.1 64 06 43 60 Fax : 00.33.1 64 06 43 66 1.
Technical characteristics - Vitreous china - ASPIROPULSOR - Choice of 15 colors - Reverse operation - Plug of visit - With seat. cover - Evacuation, rinsing and restoration of the water level is entirely automatically activated by a simple touch of the pneumatic control button : cycle time 20 seconds. TYPE MONOBLOC Dimensions 490x345x435 Motor Asynchrone Power 450 Watts Voltage 230 V. Intensity 2.8 A Electronical class Classe II Weight 34 Kg Evacuation pressure 1 bar Inlet water pressure 3 bars maxi Drainage 50 meters on the same level, 6 meters if pumping vertically in 25mm diameter tubing. Vertical evacuation in Ø internal 25 or 26 mm 6m intérieur Principle of functionning of WATERFLASH 2003 Synoptic Automatic command Rinsing Aspiration and rinsing Add some water Having lasted 8 s. Having lasted 3 s. oru 6 Having lasted 7 s. s The WATERFLASH works by pneumatic command, it is enough to press on the small opening in the middle of the button to start the following cycle: - Inflow of water of rinsing for about 8 seconds. - Start on of the aspiropulsor simultaneously with the drainage of the water for 3 seconds (or 6 seconds in the case of a vertical ascent). The motor is completly water tight. 2.
Fragmented sight WATERFLASH 2003 1. Pressostat 2. Support for time switch 3. Timer 4. Aspiropulser 5. Capacitor 6. Turbine 7. Peg 8. Frame 9. Button rivet 10. Frame screw 11. Aspiropulser casing 12. Cable collar 13. Electric cable 14. Hose clip 15. Aspiration pipe 16. Clip 17. Evacuation pipe 18. PVC bend 19. Sleeve 20. Flexible tube 21. Rinsing bend 22. Rinser 23. Linking pipe 24. Electrovanne casing 25. Electrovanne coil 26. Intervention plug 27. Push button 28. Ring 29. Embase 30. Clear tubing 31. Pal nut 32. Rislan clip 33. Time switch screws 34. Corner plate 35. Nylon nut and bolt 36. Bolt on pump casing 37. Rubber joint 38. Click clip 39. Electrovalve wiring 40. Class II 3.
Troubleshooting: how to diagnose problems and remedy them. Problem Cause Solution Poor evacuation. The aspiropulsor is connected and the water supply is open but the evacuation doesn't work. Nothing happens when the push-button is pressed. 1/ The outpipe is blocked or bent. 2/ An inappropriate object has been thrown in the bowl and is blocking the turbine. 3/ The condenser on the motor is malfunctioning. 4/ The thermal security is activated. 5/ The electronic cycle is defectuous 6/ A fuse has blown. 1/ The transparent tube is detached. 2/ Power cut. 3/ Problem in the electronic cycle. 4/ The pressostat is malfunctioning. 1/ Check the outlet pipe. 3/ Open the inspection hatch and remove the object. 4/ Change the condenser. 5/ Allow the motor to cool for 5 to 10 minutes. 6/ Change the condenser. 1/ Verify and reconnect it, verify the connection of the pneumatic button. 2/ Test the power supply. 3/ Change the timer control. 4/ Change the pressostat.. The aspiropulsor functions but the water doesn't flow. 1/ Problem in the water inlet 2/ Blocked filter on the turbine 3/ Turbine malfunctioning 4/ Problem in the electronic cycle. 1/ Verify the water supply at the tap. 2/ Unscrew the "stop-shock" tube and clean the filter. 3/ Change the turbine 4/ Change the timer control The water cycle fails to stop 1/ Turbine malfunctioning. 2/ Defect in the electronic cycle control. 1/ If after disconnecting the power supply the water continues to flow, change the turbine. 2/ If the water stops flowing, change the timer control. At the end of the cycle the water level is not restored 1/ Siphoning 1/ Put on air gape on the waste pipe. Water leak in the rinsing. 1/ Too much pressure on the water supply. 1/ Interpose a reducer of pressure to bring the pressure to 3 bars maxi. 2/ Verify the good fitting of the pipe of rinsing. The cycle sees out systematically continuously. 1/ Defective electronic cycle. 1/ Change the timer. The aspiropulser works only during 1 or 2 seconds. 1/ Defective electronic cycle. 2/ Defective thermic protection. 1/ Change the timer. 2/ Change the aspiropulser. 4.
Pressure switch Before may 2000 : Be careful : Before every modification disconect the electricity supply. Since may 2000 : 5.