CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

Similar documents
INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 8kW QUIKTHERM RETHERM OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor CONVECTION OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor Undercounter AquaTemp HUMIDITY OVENS and CONVECTION OVENS 2000 WATTS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor QUIKTHERM RETHERM ROLL-IN OVENS WITH RACK 18,000, 12,000 or 8,000 WATTS

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCMQ Series Hot Cabinet and H138NPSCMQ-15A Series Hot Cabinet

OPERATING and MAINTENANCE INSTRUCTIONS Models: H137WSUA...D & H138WS18...D Series Humidity Holding Hot Cabinet

WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN

WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY 12kW QUIKTHERM RETHERM OVEN

P P P P P

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT SMOKER OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP HUMIDITY CONVECTION and RETHERM OVENS

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS Models: 1000-CH-D SERIES

OPERATIONS MAINTENANCE MANUAL

AIR SCREEN REFRIGERATOR MODELS PHB495 & PHB15 OWNER / OPERATOR S MANUAL

WARMING AND MERCHANDISING CABINET

AHPO-6/18 GOLD PROOFER OVEN

OPERATING INSTRUCTIONS

C5 4 SERIES INSULATION ARMOUR PLUS HOT FOOD HOLDING CABINETS

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE

OWNER S MANUAL PREMIER SERIES HIGH PERFORMANCE ELECTRIC CONVECTION OVEN. MODELS: m 3000 m 3092

WARMING AND MERCHANDISING CABINET

HOT FOOD HUMIDITY CABINET MODEL HFD-3

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

MOBILE HUMI-TEMP CABINETS

Carter-Hoffmann Equipment Manual Models RTB201, RTB202 & RTB282 RTB Series Roll-in Holding Cabinets

Models A710 and A710S Grills. TOASTMASTER Models A710 and A710S Grills

FOOD WARMING/MERCHANDISING CABINET MODEL 737/737HH

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

FOOD WARMING/MERCHANDISING CABINET

TOASTER OVEN INSTRUCTION MANUAL. Model: MCSTO6B. 6 Slice

FOOD WARMING/MERCHANDISING CABINET

Instruction Manual. Astro Staging Cabinet

B.I.C.A Built-In Coffee Appliance

OPERATING INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

6 Oz. Twin Pop. Popcorn Machine Instruction Manual Model #2666EX. Cincinnati, OH USA. Part No EX Revised June 1996

HEATED DISPLAY CABINET

Instruction Manual. Portion Cup Cheese Warmer

OPERATING INSTRUCTIONS

Product Code: AP816. User Manual. T: F: Page 1 of 6

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS.

Technical Manual and Replacement Parts List. f Real Freezers

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

INSTALLATION & OPERATION MANUAL

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE

Glass Door Merchandiser Refrigerator and Freezer

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width

Citation Models #2001, 2001ST, 2001BN Instruction Manual

Cincinnati, OH USA

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Cincinnati, OH USA

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

As a safety precaution we recommend all instructions and safety tips appearing in this manual be reviewed prior to operation.

Instruction Manual. Super 88

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

TC90S TC90B. TC90 Series. InterMetro Industries Corporation Wilkes-Barre, PA

INSTALLATION and OPERATION INSTRUCTIONS

Built-in Conventional Oven

PERFORM Operating Document. General maintenance of Stoves, Fridges and Pots and Pans in the Nutrition Suite

MOBILE HUMI-TEMP CABINETS

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

CATALOG OF REPLACEMENT PARTS

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE

FOOD WARMING/MERCHANDISING CABINET MODEL

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

MERCHANT POPCORN MACHINE SERVICE MANUAL

OPERATIONS FOOD HOLDING & TRANSPORT CABINETS. wîttco foodservice. equipment

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

Solid Door Top Mount Reach-In Freezer

INSTALLATION & OPERATION MANUAL

P-60 and 60 Special. Popcorn Machine Instruction Manual Model #1866, #2085, #2086 and #2656. Cincinnati, OH USA

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

concessionstands.com Instruction Manual Pop-A-Lot Model No. 2007, 2007BN, 2007ST, 2007EX, 2007STX

INSTRUCTIONS FOR OPERATION AND CARE OF

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

OWNER S MANUAL MODELS: ELECTRIC COMPACT CONVECTION OVEN. FORM NO.: S-2374 REV: A 02/07 An Employee Owned Company

HOT DOG STEAMER Instruction Manual Models: 8007 & 8012


ICE MAKER Use & Care Guide. Table of Contents... 2

Technical Manual and Replacement Parts List. Cream Dispenser

Transcription:

Rev. 14 (10/08) Page 1 of 16 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor Models: CC-2222C-PR, CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2, and CC-2222C-PRL-2

Rev. 14 (10/08) Page 2 of 16 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION INSTRUCTIONS...3 OPERATING INSTRUCTIONS...4 MAINTENANCE INSTRUCTIONS How to Clean the Unit...5 Maintenance...6, 7 Latch Adjustment...6 Trouble Shooting Guide... 7 Replacement Parts (Cabinet)...8, 9, 10, 11 Replacement Parts (Hot Unit)...12, 13, 14 Wiring Diagrams... 15, 16 ELECTRICAL DATA SHEET...FL-1484-A SERVICE POLICY and AGENCY LIST...FL-1400 WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY

GENERAL SPECIFICATIONS: Net Weight: 355 Lbx. (Includes Hot Cabinet) Dimensions: 24-15/16 W x 33-15/16 D x 77 H Casters: 5 Dia. Swivel-type (All 4 casters equipped with brakes.) Capacity: Fifteen (15) 18 x 26 pans on 3-5/8 spacing. INSTALLATION INSTRUCTIONS Rev. 14 (10/08) Page 3 of 16 ELECTRICAL SPECIFICATIONS: Model No. Hot Unit Volts Watts Amps Phase Cycle Service CC-2222C-PR CC-2222C-PL CC-2222C-PRL HU18-671-44-G 120 2000 18 1 60 Hz. AC CC-2222C-PR-2 CC-2222C-PL-2 CC-2222C-PRL-2 HU18-671-45-G 240 2000 9 1 60 Hz. AC INSTALLATION OF OPTIONAL TWIST-LOCK PLUG: (NEMA L5-20) P/N 0840-036 Replacement of electrical components must be done by a qualified electrician. 1. Cut molded plug off end of power supply cord (Item 42). 2. Remove cover from plug body by loosening three screws on face of plug. 3. Strip jacket from cord approximately 1-1/2. 4. Strip individual wires per strip gage found on rear of plug body. 5. Slide plug cover over cord. 6. Connect individual wires to plug body. Make sure color code is followed (i.e. green to green, white to white; colored to colored). 7. Pull plug cover over plug body and fasten with screws on face of plug. 8. Insure cord clamp on rear of plug is over cord jacket. Tighten cord clamp. FIELD-REVERSING CABINET DOORS: WHEN REVERSING CABINET DOORS, PROPER DOOR STOPS MUST BE INSTALLED ON ALL DOOR HINGES. INSTALLATION OF HOT UNIT: 1. Place *Hot Unit on top of cabinet. Make sure the ducts that extend out of the hot unit bottom go into the side ducts of the cabinet top. 2. Latch hot unit to the cabinet on both sides. 3. Plug power cord into proper wall outlet as follows: HOT UNIT Volts Amps. Ph. Serv. NEMA Ref. HU-18-671-44-G 120 20 1 AC 5-20 R HU-18-671-45-G 240 20 1 AC 6-15 4. Humidity Pan (For wall outlet NEMA confi guration, see FL-1484-A included in this manual.) a. Make sure splash baffles are inside humidity pan (metal pan only). b. Fill pan one-half full with water. c. Slide pan into the angles located at the inside top of the cabinet. *Hot Unit is shipped separately because of the overall height. See Replacement Parts page for Door Stop kits.

Rev. 14 (10/08) Page 4 of 16 OPERATION INSTRUCTIONS Figure 1: Control Panel HOW TO START UNIT: 1. Push the POWER switch to ON. The yellow light will light up. Yellow heating light will light, showing that the heater is on. 2. 3. Pre-heat cabinet for 45 minutes. Put food into cabinet. Be sure pans are completely inside cabinet before closing the door. Do NOT use the door to push pans in; this will damage the door. To Shut Unit Down: Push switch to OFF. TO ADJUST THE TEMPERATURE: Thermostat is pre-set at 180 F in an empty cabinet. 1. Push switch to ON. 2. Pull out plug button in the front of the Hot Unit. 3. Turn the thermostat shaft with screwdriver. a. To increase (raise) the temperature, turn shaft clockwise. b. To decrease (lower) the temperature, turn shaft counterclockwise. 4. Watch the thermometer. The actual temperature reading will be the average between the lowest and the highest as the numbers increase and decrease. 5. Snap in the plug button. NOTE: The Digital Thermometer will fl ash if cabinet temperature is below 140 F/60 C or above 250 F/121 C. Call the factory if you need different settings.

Rev. 14 (10/08) Page 5 of 16 HOW TO CLEAN THE UNIT: 1. ALLOW CABINET TO COOL. 2. REMOVE HOT UNIT BEFORE CLEANING. Wipe up spills as soon as possible. Clean regularly to avoid heavy dirt build-up. Cleaning Hints: 1. Use the mildest cleaning procedure that will do the job. 2. Always rub in the direction of the polish lines to avoid scratching the surface. 3. Use only a soft cloth, sponge, fibrous brushes, plastic or stainless steel pad for cleaning and scouring. 4. 5. Rinse thoroughly with fresh water after every cleaning operation. Always wipe dry to avoid water marks. SOIL CLEANER METHOD CABINET Inside and Outside (Stainless Steel) ROUTINE CLEANING STUBBORN SPOTS AND STAINS BURNT-ON FOODS OR GREASE Soap, Ammonia, or mild detergent* and water. Mild abrasive made for stainless steel. Chemical oven cleaner for stainless steel. 1. Sponge on with cloth. 2. Rinse with water. 3. Wipe dry. 1. Apply with damp sponge or cloth. 2. Rub lightly. Follow oven cleaner manufacturer s directions. HARD WATER SPOTS and SCALE Vinegar 1. Swab or wipe with cloth. 2. Rinse and dry. HOT UNIT, RACK INSERTS DIRT Mild detergent* & hot water, or mild abrasive cleaner. Steam (no strong alkaline additive) 1. Use soft, damp cloth. 2. Rinse with hot water. 3. Wipe dry. 1. Rinse after steam cleaning. 2. Wipe dry. Side wall Air Duct and Humidity Pan (Aluminum) FINGERPRINTS, GREASE, OIL. Chemical oven cleaner; for Aluminum Mild abrasive cleaner. Oily or waxy cleaner. Follow Oven Cleaner manufacturer s directions. Apply with soft, clean cloth. WATER SPOTS. Wipe with damp cloth. Mild abrasive cleaner. *Mild detergents include soaps and non-abrasive cleaners.

Rev. 14 (10/08) Page 6 of 16 MAINTENANCE VENT FAN FILTER MUST BE CLEANED DAILY. The filter is found on the left side of the Hot Unit. It snaps onto the fan. Soak filter in soapy water and rinse with clean water. HOW TO ADJUST THE DOOR LATCH: (Optional) 1. For vertical (up and down movement) adjustment: a. Loosen (2) screws located in magnetic strike attached to bracket on cabinet (see *NOTE). b. Move strike up or down for alignment to magnet on latch. c. Tighten screws to secure. 2. For horizontal adjustment (greater or lesser magnetic draw). a. Loosen (4) screws in door latch. b. Move latch forward or backward to adjust magnetism. c. Tighten screws to secure. NOTE: Bracket not used on 2222B Series Cabinets.

Rev. 14 (10/08) Page 7 of 16 MAINTENANCE INSTRUCTIONS TROUBLE-SHOOTING GUIDE WARNING IF UNIT GETS TOO HOT OR WON T SHUT OFF, DISCONNECT POWER AT BRANCH PANEL. DO NOT UNPLUG CORD! If hot unit is NOT working, first check the following causes: 1. Cord is unplugged from wall outlet. 3. Switch is turned off. 2. Circuit breaker/fuse to wall outlet is blown. 4. Thermostat is turned off, or is set too low. (See Thermostat Calibration ). If the four items above check out all right and the Hot Unit STILL doesn t work, one or more of the components listed under the problems below will have to be checked and replaced. PROBLEM 1. Cabinet does not heat, or doesn t heat properly POSSIBLE CAUSE 1a. Fuse 1b. Thermostat 1c. Heater 1d. Blower 1e. Hi-limit Swtich 1f. On/Off Switch 2a. On/Off Switch 2b. Fuse 2. Blowers do not operate 2c. Blower Motor 2d. Thermostat 3. Heaters will not shut off 3a. Thermostat 4. Vent fan does not shut off 5. Vent fans do not operate (See Note) 4a. Vent Fan Switch 4b. Control compartment is still hot. 5a. Fuse 5b. Vent fan switch defective 5c. Vent fan defective NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement of electrical components must be done by a qualified electrician. Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service centers. Instructions for replacing parts are included in replacement parts list.

Rev. 14 (10/08) Page 8 of 16 REPLACEMENT PARTS for CC-2222C Cabinets (Manufactured from 4/00 to present) Include all information on nameplate when ordering parts 1 17 12 9 2 8 7 6 11 10 8 14 15 16 Item DESCRIPTION REQ D PART NUMBER 1 Hot Unit, Complete 110-120 Volt 1 HU-18-671-44-G 220-240 Volt 1 HU-18-374-45-G 2 Door Kit 4 1221-455-K Door Kit w/full 1221-459-K window (optional 6 Latch & Strike Kit 4 1006-104-K1 8 Gasket Kit 4 0861-168 9 Rack Insert, Upper 1 1103-096 13 REPLACEMENT PARTS for CC-2222 CABINETS (Manufactured from 4/00 to present) Item DESCRIPTION REQ D PART NUMBER 10 Rack Insert, Lower 1 1103-097 11 Shoulder Screw 16 0567-236 12 Hinge Kit 4 0519-087-K 13 Casters w/brake 4 0569-306-B 14 *Caster Screw 16 0567-103 15 *Caster Lockwasher 16 0567-080 16 *Caster Hex Nut 16 0567-062 17 Door Stop Kit, RH Door Stop Kit, LG 0553-706-K 0553-707-K *Indicated but not shown.

Rev. 14 (10/08) Page 9 of 16 REPLACEMENT PARTS for CC-2222B Cabinets (Manufactured from 10/97 thru 3/00) Include all information on nameplate when ordering parts 1 17 12 9 2 8 7 6 11 10 8 14 15 16 REPLACEMENT PARTS for CC-2222B CABINETS (Manufactured from 10/97 to 3/00) Item DESCRIPTION REQ D PART NUMBER Item DESCRIPTION REQ D PART NUMBER **1 Hot Unit, Complete 11 Shoulder Screw 16 0567-236 110-120 Volt 1 HU-18-671-44-G 12 Hinge Kit 4 0519-087-K 220-240 Volt 1 HU-18-374-45-G 13 Casters w/brake 4 0569-306-B 2 Door Kit 4 1221-455-K 14 *Caster Screw 16 0567-103 6 Latch & Strike Kit 4 1006-104-K1 15 *Caster Lockwasher 16 0567-080 (optional) 8 Gasket Kit 4 0861-168 9 Rack Insert, Upper 1 1103-069 10 Rack Insert, Lower 1 1103-070 ** Note: When ordering replacement Hot Units, low-profi le water pan 1017-076 is required. 13 16 *Caster Hex Nut 16 0567-062 17 Door Stop Kit, RH 0553-706-K Door Stop Kit, LG 0553-707-K *Indicated but not shown.

Rev. 14 (10/08) Page 10 of 16 REPLACEMENT PARTS for CC-2222A Cabinets (Manufactured from 6/96 to 10/97) Include all information on nameplate when ordering parts REPLACEMENT PARTS for CC-2222A CABINETS (Manufactured from 6/96 to 10/97) Item DESCRIPTION REQ D PART NUMBER 1 Hot Unit, Complete 110-120 Volt 1 HU-18-671-44-F 220-240 Volt 1 HU-18-374-45-F 2 Door Kit 4 1221-445-K 6 Latch & Strike Kit 4 1006-108-K2 (optional) 8 Gasket Kit 4 0861-168 9 Rack Insert, Upper 1 1103-069 Item DESCRIPTION REQ D PART NUMBER 10 Rack Insert, Lower 1 1103-070 11 Shoulder Screw 16 0567-236 12 Hinge Kit 4 0519-087-K 13 Casters w/brake 4 0569-306-B 14 *Caster Screw 16 0567-103 15 *Caster Lockwasher 16 0567-080 16 *Caster Hex Nut 16 0567-062 *Indicated but not shown.

Rev. 14 (10/08) Page 11 of 16 REPLACEMENT PARTS for CC-2222 Cabinets (Manufactured thru 5/96) Include all information on nameplate when ordering parts REPLACEMENT PARTS for CC-2222 CABINETS (Manufactured thru 5/96) Item DESCRIPTION REQ D PART NUMBER 1 Hot Unit, Complete 110-120 Volt 1 HU-18-671-44-F 220-240 Volt 1 HU-18-374-45-F 2 Lower Door Kit, RH 2 5508-047 3 Lower Door Kit, LH 2 5508-046 4 Upper Door Kit, RH 2 5508-046 5 Upper Door Kit, LH 2 5508-047 6 & 7 Latch & Strike Kit 4 1006-104-K1 Item DESCRIPTION REQ D PART NUMBER 8 Gasket Kit 4 0861-168 9 Rack Insert, Upper 1 1103-069 10 Rack Insert, Lower 1 1103-070 11 Shoulder Screw 16 0567-236 12 Hinge Kit 4 0519-079-K 13 Casters w/brake 4 0569-306-B 14 *Caster Screw 16 0567-103 15 *Caster Lockwasher 16 0567-080 16 *Caster Hex Nut 16 0567-062 *Indicated but not shown.

Rev. 14 (10/08) Page 12 of 16 HOT UNIT REPLACEMENT PARTS Manufactured from 3/00 to present) Include all information on nameplate when ordering parts 46 42 43 17 18 41 40 21 31 30 28 22 37 28 27 20 39 38 25 23 24 26 44 36 35 19 45 34 32 33 HOT UNIT REPLACEMENT PARTS (Manufactured from 3/00 to present) Item DESCRIPTION REQ D Part No s. per Hot Unit HU-18-671-44-G HU-18-671-45-G 17 Cover, Top 1 6169-161 6169-161 18 Cover, RH Side 1 6169-162 6169-162 19 Bottom Plate 1 0672-310 0672-310 20 Cover, LH Side 1 6169-163 6169-163 21 Term. Block, Rear 1 0852-090 0852-090 22 Terminal Block 1 0852-091 0852-091 23 Pilot Light, Yellow 1 0766-094 0766-095 24 Pilot Light, Yellow 1 0766-094 0766-095 25 Switch Kit 1 0808-118-K 0808-116 26 Plug Button 1 0847-004 0847-004 27 Thermostat 1 0848-062-K 0848-062-K 28 Thermometer 1 5238-034 5238-034 29 Transformer 1 0769-159 0769-159 110V/220V 30 Vent Fan Switch 1 0848-034 0848-034 31 Hi-Limit Switch 1 0848-033 0848-033 Item DESCRIPTION REQ D Part No s. per Hot Unit HU-18-671-44-G HU-18-671-45-G 32 Clamp, T-Stat Bulb 1 0567-496 0567-496 33, Thermometer 1 0806-055 0806-055 34 Spacer 1 0818-017 0818-017 35 Blower Motor Kit 2 0769-005-K 0769-006-K1 36 Heater Kit 1 0811-022-K 0811-023-K 37 Vent Fan 1 0769-045-K 0769-029-K 38 Vent Fan Filter 1 0769-140 0769-140 39 Catch-Latch Ass y. 2 1246-021 1246-021 40 Fuse Holder 1 0807-048 0807-048 41 Fuse 1 0807-058 0807-058 42 Power Supply Cord 1 0810-065 0810-039 43 Strain Relief Cord 1 0818-050 0818-050 44 Baffl es 1 1052-063 1052-063 45 Humidity Pan 1 1017-076 1017-076 46 Plug, Twist Lock, Alt. 1 0840-036 Not Available

Rev. 14 (10/08) Page 13 of 16 HOT UNIT REPLACEMENT PARTS Manufactured from 10/97 thru 3/00) Include all information on nameplate when ordering parts HOT UNIT REPLACEMENT PARTS (Manufactured from 10/97 to 3/00) Item DESCRIPTION REQ D Part No s. per Hot Unit HU-18-671-44-G HU-18-671-45-G 17 Cover, Top 1 6169-161 6169-161 18 Cover, RH Side 1 6169-162 6169-162 19 Bottom Plate 1 0672-310 0672-247 20 Cover, LH Side 1 6169-163 6169-163 21 Term. Block, Rear 1 0852-090 0852-090 22 Terminal Block 1 0852-091 0852-091 23 Pilot Light, Yellow 1 0766-094 0766-095 24 Pilot Light, Yellow 1 0766-094 0766-095 25 Switch Kit 1 0808-118-K 0808-116 26 Plug Button 1 0847-004 0847-004 27 Thermostat 1 0848-062-K 0848-062-K 28 Thermometer 1 5238-034 5238-034 29 Transformer 1 0769-159 0769-159 110V/220V 30 Vent Fan Switch 1 0848-034 0848-034 31 Hi-Limit Switch 1 0848-033 0848-033 Item DESCRIPTION REQ D Part No s. per Hot Unit HU-18-671-44-G HU-18-671-45-G 32 Clamp, T-Stat Bulb 1 0567-496 0567-496 33, Thermometer 1 0806-055 0806-055 34 Spacer 1 0818-017 0818-017 35 Blower Motor Kit 2 0769-005-K 0769-006-K1 36 Heater Kit 1 0811-022-K 0811-023-K 37 Vent Fan 1 0769-045-K 0769-029-K 38 Vent Fan Filter 1 0769-140 0769-140 39 Catch-Latch Ass y. 2 1246-021 1246-021 40 Fuse Holder 1 0807-048 0807-048 41 Fuse 1 0807-058 0807-058 42 Power Supply Cord 1 0810-065 0810-039 43 Strain Relief Cord 1 0818-050 0818-050 44 Baffl es 1 1052-063 1052-063 45 Humidity Pan 1 1017-076 1017-076 46 Plug, Twist Lock, Alt. 1 0840-036 Not Available ** Note: When ordering replacement Hot Units, low-profi le water pan 1017-076 is required.

Rev. 14 (10/08) Page 14 of 16 HOT UNIT REPLACEMENT PARTS Manufactured thru 10/97) Include all information on nameplate when ordering parts HOT UNIT REPLACEMENT PARTS (Manufactured thru 10/97) Item DESCRIPTION REQ D Part No s. per Hot Unit HU-18-671-44-F HU-18-671-45-F 17 Cover, Top 1 6169-067 6169-067 18 Cover, RH Side 1 6169-083 6169-083 19 Bottom Plate 1 0672-162 0672-162 20 Cover, LH Side 1 6169-085 6169-084 21 Term. Block, Rear 1 0852-090 0852-090 22 Terminal Block 1 0852-091 0852-091 23 Pilot Light, Yellow 1 0766-048 0766-045 24 Pilot Light, Yellow 1 0766-047 0766-046 25 Switch Kit 1 0808-081 0808-080 26 Plug Button 1 0847-004 0847-004 27 Thermostat 1 0848-062-K 0848-062-K 28 Thermometer 1 5238-024 5238-024 29 Transformer 1 0769-159 0769-159 110V/220V 30 Vent Fan Switch 1 0848-034 0848-034 31 Hi-Limit Switch 1 0848-033 0848-033 Item DESCRIPTION REQ D Part No s. per Hot Unit HU-18-671-44-G HU-18-671-45-G 32 Clamp, T-Stat Bulb 1 0567-496 0567-496 33, Thermometer 1 0806-055 0806-055 34 Spacer 1 0818-017 0818-017 35 Blower Motor Kit 2 0769-005-K 0769-006-K1 36 Heater Kit 1 0811-022-K 0811-023-K 37 Vent Fan 1 0769-045-K 0769-029-K 38 Vent Fan Filter 1 0769-140 0769-140 39 Catch-Latch Ass y. 2 1246-021 1246-021 40 Fuse Holder 1 0807-048 0807-048 41 Fuse 1 0807-058 0807-058 42 Power Supply Cord 1 0810-065 0810-039 43 Strain Relief Cord 1 0818-050 0818-050 44 Baffl es 1 1052-063 1052-063 45 Humidity Pan 1 1017-0051 1017-051 46 Plug, Twist Lock, Alt. 1 0840-036 Not Available

Rev. 14 (10/08) Page 15 of 16 WIRING DIAGRAMS for 0671-044-G and 0671-045G

Rev. 14 (10/08) Page 16 of 16 WIRING DIAGRAMS for 0671-044-F and 0671-045F 2148 WATTS, 120 VOLTS 1 PHASE, 60 HZ., 16.6 AMPS CORD G W TB2 13 2 H1 7 SW2 BM 10 4 9 TH1 F1 8 P1 HEATER ON R 5-20P 14 1 3 TB1 BM 6 11 15 A t S1 THIS LEAD MAY BE OMITTED 12 11 10 1 2 3 4 T TM 5 7 8 (12V) TEMP. 16 DISPLAY 18 (12V) 17 10 VF SW3 5 6 8 1 SW1 P2 POWER ON F1 BM H1 P1 P2 S1 SW1 SW2 SW3 T TH1 TB1 TB2 TM VF LEGEND FUSE MOTOR- BLOWER HEATER PILOT LIGHT, RED, HEATER ON PILOT LIGHT, AMBER, POWER ON SENSOR SWITCH,SPST SWITCH, HIGH LIMIT SWITCH, VENT FAN TRANSFORMER THERMOSTAT TERMINAL BLOCK TERMINAL BLOCK THERMOMETER VENT FAN SLEEVING 0815-022-06 SLEEVING 2148 WATTS, 240 VOLTS 1 PHASE, 60 HZ., 8.3 AMPS CORD 6-15P G 14 TB2 13 2 1 18 15 12 3 H1 TB1 7 SW2 BM BM 10 4 F1 TH1 6 P1 HEATER ON 9 R 8 11 A t S1 THIS LEAD MAY BE OMITTED TM 12 (12V) TEMP. 11 DISPLAY 10 (12V) 1 2 T 5 16 7 19 17 3 8 4 12 10 VF SW3 5 12 6 8 2 1 P2 POWER ON SW1