GPS or DCF 77. DTS Masterclock

Similar documents
DTS MOBATime's Distributed Time System

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

INSTRUCTION MANUAL. Change Over Unit ECO for ETC 24R MOBATIME BE

Panel Mounted Fault Annunciator Series

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

IntesisBox BACnet/IP Server - Notifier ID3000 series

Panel Mounted Fault Annunciator Series

Dew point set DS 400

Alarm module for leak detection with webserver

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Solution F2. Fire Alarm Control Panels one step ahead.

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Security designed for your lifestyle

N-8000 SERIES IP INTERCOM SYSTEM

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

Call stations and extensions

ACTIVE INFRARED BARRIER

Window facia fault annunciators

IndigoVision Alarm Panel. User Guide

Intelligent Security & Fire Ltd

ME 3011C / Alarm Indication / Quick Reference Guide

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

CMC-TC Processing Unit II Assembly, Installation and Operation Manual

Universal fault annunciator for panel mounting

Parameterisable compact fault annunciator with permanent display

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

RACK MONITORING SYSTEM - RAMOS Ultra

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Fire alarm system EBL512 G3

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Analog Annunciator Unit SACO 16 A3. Product Guide

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

CMC-TC Basic CMC DK

Fire Alarm Network Reference

MASTER CLOCK SYSTEM TECHNICAL & USER MANUAL TECHNICAL MANUAL. A100K10807 v.1.5

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

DSE ELECTRONIC SIRENS Advantages & Functions

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

RACK MONITORING SYSTEM RAMOS Ultra

Galaxy Pulsar Plus Digital Battery Plant Controller

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

LORAIN CIP 4890/48120 DC Power System

APC BC300 Series 40kW 208/450/480V User Guide

Fire and Gas Monitoring Panel ST7-HV

Added password for IP setup page : Password must be in IP format!

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

GasGard 100 Control System

CMC-TC Processing Unit II DK

Intelligent 2 & 4 Loop Fire Alarm Control Panels

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

ECO N DATE DESCRIPTION OF CHANGE CHG

Segment design & and Bus Diagnostics

Labkotec Ice Detector

Process Alarm Solutions

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

CMC- Top Concept A redefinition of rack security

Engineering Guideline. pac- Carriers Type Universal

ModBus DE-1 INSTALLATION AND USER MANUAL

Intelligent addressable fire alarm control panel

On the job around the clock 24/7: Fire detection systems

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Intelligent Single Loop Fire Alarm Control Panel

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

APPLICATION DATA SHEET

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Danfoss gas detection units

The supplier and installer of the system should be approved by the local civil defence authority.

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

HI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics

P2267 NETWORK INTERFACE

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Elemec3. Networked Public Address and General Alarm System (PA/GA)

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Installation Manual COPYRIGHT NOTICE

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Annunciator Unit SACO 16 D1. Product Guide

DS-2TD Thermal & Optical Network Bullet Camera

SCR100 User Manual. Version:1.1 Date:Dec 2009

Cold chain monitoring technologies. Facility monitoring

600 Range Dialer Installation Manual. Version 1.0

Complex alarming made simple

User manual for CPR32-NET network controller

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Transcription:

GPS or DCF 77 DTS Masterclock DTS Manager and DTS Master Software DTS MOBATime's Distributed Time System LAN The multi purpose time server in the new LAN and -based Distributed Time System by MOBATime DTS 4135.timeserver The DTS 4135.timeserver sets new standards as a time reference for all clients in medium and large networks (LAN Ethernet/IP/UDP). It is highly precise and with its intelligent concept for redundant operation, it offers a high degree of reliability and availability. The DTS 4135.timeserver can either be synchronized from a time signal receiver (DCF 4500, GPS 4500 or IRIG/AFNOR time source), or from another or S time server in the LAN or Internet. The DTS 4135 can synchronize all slave clocks with movements, either with Multicast or Unicast (both with timezone server function). As a multi purpose device the timeserver is equipped with two independent IRIG/AFNOR outputs, two serial RS 232/RS 485 interfaces with script file programmable telegrams, two DCF or high accurate pulse /frequency outputs (RS 422 and current loop) and one additional DCF current loop output. The highest degree of system security and reliability can be achieved by the master-slave operation of two DTS 4135.timeservers connected via fiber-optic (redundant operation). Alarms are signaled by alarm relay, SNMP messages or e-mails.

DTS 4135.timeserver - the innovative, precise time reference for networked, multifunctional systems Time precision Best accuracy can be achieved by synchronizing the DTS 4135 via a connected GPS receiver. The internal time is adjusted to the time reference (e.g. GPS) in one step or in small adjustable micro-steps to avoid any time leaps (e.g. after a longer loss of the time source), thanks to the intelligent time management. To achieve utmost accuracy, the quartz drift and aging is continuously compensated. Top performance - even for large networks The high performance DTS 4135 timeserver can answer more than 250 and S requests per second. It can also work as an time reference for a subnetwork, being synchronized from a superior - Server (client and server at the same time). Secure Supports authentication for increased security, which allows clients, to verify the received packets. Safe, convenient operation After configuring an IP address via serial interface (terminal program), operation over LAN via Telnet, SSH or SNMP protocols is possible. SSH and SNMP (MD5 authentication and DES for encryption) enable a secured connection. Special software is required for operation by SNMP protocol. Effective fault indication Alarms are reported by alarm relay, by e-mail, or via SNMP messages. Additionally, the display can be used to check the alarm state by pressing the red push button. Front view Connectors: LAN connector RJ 45, 10/100 Mbit PC terminal connector, RS232 Sub-D 9p male USB connector for software update, maintenance or file download to the timeserver (e.g. telegram files, timezone table...) LEDs: Mains power, alarm, synchronization and network transmission control. Display: Time, date, status, alarm, IP... Rear view Connectors: Power: Mains power connector, 2 DC power supply inputs, DC output (e.g. for GPS) Alarm: alarm relay contact, alarm input Synch. inputs: IRIG-B/AFNOR input (BNC), DCF current loop Synch. outputs: DCF current loop, DTS link (GBIC-module) Serial: 2 RS 232/485, both for script file progr. serial message IRIG: 2 IRIG-B/AFNOR outputs (BNC) IRIG DC: 2 DC level IRIG-B/AF- NOR outputs (both RS 422 & current loop) Pulses: 2 DCF or pulse/frequency outputs (both RS 422 & current loop) DTS device mounted in a 19 IT-Rack

DTS 4135.timeserver - the time source for LAN-based clock and time distribution systems The DTS 4135.timeserver is a versatile time reference in several respects. On the one hand, it relays the external time signals with maximum precision and reliability directly to all unicast (IP based) or multicast devices, such as slave clocks with movement (e.g. NBU 190,...), digital clocks, and digital information displays with synchronisation. On the other hand, it can also synchronize the NCI (Network Clock Interface), which for its part can control master clocks and slave clocks with MOBALine and DCF 77 input. Even PCs/workstations, photocopiers, printers, fax equipment, time recording terminals, and access control systems, central fire alarm systems, image and sound recording equipment, and many other clients in the network can be directly synchronized by means of the protocol. DTS 4135.timeserver DTS Manager DTS Masterclock LAN WAN

DTS 4135.timeserver - greatest priority for security and reliability Redundant operation To avoid time deviation between two DTS 4135.timeservers, they can be linked via a fiber-optic connection by using two GBIC modules. The two timeservers automatically negotiate their state as master or slave. The slave is always synchronized by the master. In case of GPS failure, an automatic swap between master and slave state will occur. The parameters for the swap can be configured. The master DTS timeserver always has the better stratum level than the slave. Redundant power The DTS 4135.timeserver has several monitored power inputs for completely redundant power supply. The non-active power supply input is also monitored. Possible power variants: 24 VCD, non-redundant 230 VAC, non-redundant 24 VDC + 24 VDC, redundant 230 VAC + 24 VDC, redundant Redundant outputs Redundant IRIG-B/AFNOR, serial telegram, DCF and/or pulse/frequency outputs can be achieved by the External Change Over unit (ECO). Master GBIC modules Slave LAN WAN Monitored inputs 85...265 VAC 24 VDC 24 VDC

DTS 4135.timeserver, versatile high precision Master Clock and Time Server DTS 4135.timeserver e.g. as server and master clock for high precision IRIG-B/AFNOR outputs, for RS 232/485 serial messages and technical pulses or frequencies. Time signal receiver GPS 4500 DCF 4500 Redundant Server DTS 413x.timeserver Central monitoring SNMP, E-mail LAN / WAN Services Clients Process controller Analogue and digital clocks IRIG-B/AFNOR/DCF-FSK Voice recording Audio and image recording Computers Process controller Building automation RS 232/485 serial outputs High precision DCF, Pulse or Frequency ouputs Process controller Building automation Sub-Master Clock DTS 4135, AFNOR synchronized DTS 4135.timeserver with two IRIG-B/AFNOR outputs to control analogue and digital slave clocks, process controllers, voice recording systems and many other technical equipment. Typical application e.g. for power distribution stations or energy production plants, where high reliability, high precision, no time leaps and permanent availability are required. DTS 4135.timeserver with two RS 232/485 serial outputs, programmable message with script file, for synchronization of any kind of technical equipment like e.g. computer server, process controller, fire supervision system,... To increase the precision of the synchronization, two high accurate pulse outputs are provided. They can either be used as DCF outputs (RS 422 and current loop) or periodical pulses. Typical application e.g. for power distribution stations or energy production plants, industries...

DTS 4135.timeserver - Technical and performance details Technical Data Time signal outputs DTS Link (Redundancy -slave clock line Network services V4 (fully V3 compatible) / S, multicast DCF-time signal output (current Loop passive) 2 x IRIG-B/AFNOR output, each with analogue (BNC) and DC level (RS 422 and current loop) output 2 x DCF 77, programmable pulses/frequencies (RS 422 and current loop) 2 x RS 232/485 serial message programmable by script file Max. length of the fiberglass cable, e.g. multimode fiber Ø 50 µm: multimode fiber Ø 62.5 µm: For slave clocks synchronized by multicast or unicast (IP based). Timezone server function with up to 15 different time zone entries. client server, max. no. of and S client requests: SNMP V1, V2c, V3 (get, put, modif.) with MD5 authentic. and DES for encryption E-mail for alarm messages (2 addresses possible) Time, date, FTP (for update) Network Interface 10BaseT / 100BaseTX (IEEE 802.3) Data transmission rate: auto-negotiation / manual Connection: RJ45 (only shielded cable permitted) IP configuration DHCP, static IPv4, IPv6 Operation Serial terminal via RS 232 (front side, sub-d 9p male) Via LAN: Telnet, SSH, SNMP (special software necessary) USB connector for software update, maintenance (config. and log files upload) or file download (e.g. telegram files...) LED indication Power supply, synchronization status, LAN status, alarm, DCF input Display for status information: Time, date, IP, alarm... Local time calculation Automatic, preprogrammed daylight saving time change. Up to 80 pre-defined time zone entries and 20 user-definable entries. All outputs can be individually allocated to a time zone (UTC or local time) Accuracy GPS (DCF input) to server: GPS (DCF input) to DCF 77 / pulse output: to internal time: Redundant operation: master to slave GPS (DCF input) to IRIG (analogue) GPS (DCF input) to IRIG (digital) Internal time to serial outputs (jitter: +/- 10ms) Time-keeping (internal) DTS 4135 -> TCXO DTS 4136 -> OCXO External time source Synchronized with GPS: Hold over (after >24h synch. from GPS) at 20 C +/- 5 C: Hold over (after >24h synch. from GPS) at const. temp.: After restart without synchronization (for 24 hours) at 20 C +/- 5 C: Hold over (after >24h synch. from GPS) at 20 C +/- 5 C: External / S server (4 sources possible), and / or DCF 77- time signal receiver (current Loop, e.g. DCF 4500), or GPS time signal receiver (current Loop, e.g. GPS 4500), or IRIG-B/AFNOR (analogue), or manual time setting (only for test purposes) IRIG-B122, IRIG-B123, AFNOR A, AFNOR C, DCF-FSK,... max. 550 m max. 275 m typical > 250 requests/sec typical < +/- 100 µs typical < +/- 10 µs typical < +/- 100 µs typical < +/- 1 µs typical < +/- 100 us typical < +/- 10 us typical < +/- 10 ms +/- 10 µs to UTC < +/- 10 ms/d or < 0.1 ppm < +/- 1 ms/d or < 0.01 ppm < +/- 250 ms/d or < 2.5 ppm < +/- 1 ms/d or < 0.01 ppm Alarm relay Potential free, opening contact for signalizing disturbances open -> alarm Alarm input 1 alarm input for monitoring of an external device, 18-36 VDC, max. 6 ma input open -> alarm Power supply AC input: 85.. 265 VAC / 50-60 Hz / max. 15 VA 2 x DC input: 24 VDC + 20 % / - 10 % / max. 10 W DC output: nominal 28 VDC, max. 400 ma Dimensions 19 rack, 1 rack unit, W x H x D mm 483 x 44 x 125 Weight approx. 1.8 kg Power reserve none Ambient temperature -5 to 50 C, 10-90 % relative humidity, without condensation MOSER-BAER AG CH-3454 Sumiswald/Geneva, Switzerland www.mobatime.com LE-800720.00