Aspirating Smoke Detection (ASD) Systems Fire Detection

Similar documents
High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

High-precision aspirating smoke detectors for every requirement.

Honeywell Air Sampling Devices Data Sheet

Saving lives, protecting valuables, securing process cycles Fire detection

Honeywell Air Sampling Devices Data Sheet

Aspirating smoke detection

Air Sampling Smoke Detection

Aspirated Smoke Detectors

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

Aspirating Smoke Detection for Large Area Coverage Applications

Flexible Air-sampling Smoke Detection

LEARNING SPECIAL HAZARD DETECTION TYPES

CO 2 EXTINGUISHING SYSTEMS

Aspirating Detection System. Protec Aspirating Detection System Atria Design Guide. MED2199 Atria Design Guide Issue 0 Page 1 of 22

GE Security. air sampling pipe networks installation and design manual

Aspirating Detection System. Protec Aspirating Detection System Lift Shaft Design Guide. MED2198 Lift Shaft Design Guide Issue 0 Page 1 of 23

Guidance Note. Guidance Document on Best Practice for Fire Detector Testing/Test Equipment

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

EXTINGUISHES FIRES QUICKLY AND EFFECTIVELY. FirExting Gas extinguishing systems with non-liquefied and natural inert gases. Nitrogen Argon IG-541

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Guidance on Video Smoke Detection Technology (VSD)

technical specification smoke venting systems

Intelligent Earliest Warning Aspirating Fire Detector

Data Centers. ASD 535 Application Report

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

Saving lives, protecting valuables, securing process cycles Fire detection

Fire protection for a hazardous materials. warehouse. OxyReduct FirExting TITANUS. Reference solution

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Automated Fire Detection and Suppression in a Retrofitted Tunnel Using Fiber-Optic Linear Heat Detection

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

THE FIXED AEROSOL EXTINGUISHING SYSTEM - FIRE JACK

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

LaserFOCUS VLF-250 Engineering Specification

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

designed for rail 5000 Series

Fire protection for emergency power supply

HYDROCARBONENGINEERING June June 2015

VESDA. White paper. Using air sampling smoke detection to protect mission-critical facilities from fire. Overview

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Cooker Hood LA-72-CAN.

FAAST. Fire Alarm Aspiration Sensing Technology

AUTOMATIC FIRE SUPPRESSION SYSTEMS

FAAST. Fire Alarm Aspirating Sensing Technology

Protezione antincendio di dati e business critical assets nei Data Centers

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles

Laser Technology Smoke Detector

FIRE PROTECTION IN SUB-ZERO TEMPERATURES. DELIVERY CAPACITY ON ICE. DELIVERY CAPACITY WITH GUARANTEED PROTECTION.

Important Safety Notice

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Industrial Fire Detection

Aspirating Smoke Detection for Duct Monitoring

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

FIRE SUPPRESSION SYSTEM

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

Power Generation. ASD 535 Application Report

INTERNATIONAL STANDARD

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

Fire Suppression Systems

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen

(Material correct at 1/11/2011)

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Effective, efficient response for emergency situations Risk Management

CRU-S Series Stainless Steel Condensate Recovery Unit

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Thermal Oil Heating System. Heat Recovery System. Member of the

OH110, OP110, HI110 Automatic fire detectors

SMOKE CONTROL - NEW DIRECTIONS

Installation and Operation Manual

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

Buys Time. Aspirating Smoke Detection

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

The new detector from Rafiki

EARLIEST SMOKE DETECTION WITH MAXIMUM FLEXIBILITY

Press Presse Press Presse

Aspirating Systems Design and Application Guide

Dräger Flame 2100 Flame Detection

Vacuum in the laboratory. products and solutions

Industrial fire alarm systems

Aspir A ation spir P R O D U C T S

Fixed High Volume Water Spray System fireward.co.uk

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Fact File 66. Guide to Beam Smoke Detectors

scorpion SMOKE TESTING FOR ASD SYSTEMS AND HARD-TO-ACCESS POINT DETECTORS IN ACADEMIA APPLICATIONS RESTRICTED AREA AUTHORISED ENTRY ONLY

FAAST Beyond Standard Methods of Detection

Infra-Red Transit Heat and Flame Sensors. Early warning fire detection to protect conveyors, product and plant

Desigo Fire Safety intelligent detectors for complete safety

How can you minimize consequential damages in case of a fire?

Crime Central Station Burglary Alarm Systems

VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

FAAST PRODUCT RANGE Aspirating Smoke Detection

FAAST. Fire Alarm Aspirating Sensing Technology

Aspirating Smoke Detection

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Transcription:

Aspirating Smoke Detection (ASD) Systems Fire Detection A complete guide for the fire system specifier, designer and installer

Aspirating Smoke Detection WAGNER UK Limited Better Solutions in Fire Protection This guide has been produced by WAGNER UK. WAGNER has developed a number of innovative fire protection solutions to meet the demands of today's complex buildings and business operations. These include the TITANUS family of air sampling smoke detection systems and OxyReduct - a fire prevention system that stops fires from starting in the first place.

Contents Introduction to ASD Standards ASD System Design Applications WAGNER Product Range The WAGNER Advantage OxyReduct Support Services 1 3 5 7 11 13 15 Back cover

Introduction to ASD Early Warning Fire Detection 1 ASD systems can detect fires at a very early stage, often before visible smouldering takes place, before an open fire occurs and before intense smoke develops. This early detection is vital to mission critical and high-risk applications. The earliest possible fire detection brings significant time benefits, enabling a fast response to the first signs of smoke. ASD can detect fires with a thousand times more sensitivity than point smoke detectors.

Operation ASD systems draw air samples continuously from the monitored area through a pipe system fitted with sampling holes at regular intervals. The airflow is then analysed for smoke particles and an alarm is raised if smoke is present. The system is active, continually pulling air samples from the risk. Monitored area The sampling holes in the monitored area are arranged so that the same amount of air is drawn through each hole. Each sampling hole is therefore allocated the same monitored coverage as a point-type smoke detector. Cumulative effect A cumulative effect is achieved by having multiple sampling holes in a room that extract any smoke that arises simultaneously. In these conditions the sensitivity of an ASD system offers a huge advantage. In spaces with high-ceilings, the cumulative effect can often contribute up to 50 %, an amount that can increase still further depending on the space and height of the room. High false alarm immunity The physical separation of the detection unit from the monitoring area reduces the risk of transient faults such as those caused by condensation and electromagnetic radiation. The use of filters and the appropriate signal processing also guarantee reliable detection in dusty conditions. Simple accessibility minimal disruption Maintenance and service tasks are carried out in central, easily accessible places. This means that the monitored area does not have to be accessed. There is no longer any need to inspect individual detection points under the ceiling, as is the case with conventional fire detectors. Aesthetically pleasing The smoke sampling holes in the ceiling can be installed so inconspicuously that they do not interfere with the aesthetics of the building interior. This reduces the limitations on architects and planners and gives them greater freedom of design. Deterrent against vandalism The virtually invisible integration of the smoke sampling holes in the ceiling offers almost no target for vandals. Simplified operating principle 2

Standards The new EN54-20 European Standard 3 EN54 Part 20 is the new European product standard for Aspirating Smoke Detectors (ASD). From July 2009 the vast majority of ASD systems installed in Europe will have to fully comply with this standard. The standard encompasses both the project design and the ASD systems installed. Since ASD systems, like other detectors for fire detection systems, fall under the Construction Products Directive, compliance with EN 54 Part 20 is a prerequisite for CE marking.

Sensitivity Classes EN54-20 introduces three classes for detector sensitivity: Class A - Very High Sensitivity Used where very early warning fire detection is required. Designed primarily for high-risk areas and where high levels of air conditioning and air dilution exist. Class B - Enhanced Sensitivity - Very early fire detection for most areas in which valuable goods and/or processes need to be protected. Class C - Normal Sensitivity For general fire protection applications. This sensitivity is equivalent to standard point detection. It is vitally important that sensitivity thresholds do not change due to long-term drift and changing environmental conditions, as installations could become non-compliant over time. These Classes now define a transparency for designers allowing system performance to be properly compared. ASD Accessories The standard also dictates that all accessories such as blow back equipment for maintenance, external filters and water traps have to be tested and approved with the system. It is no longer acceptable to design ASD systems with non-approved components. British Standards In addition to EN54-20, ASD systems should be designed and installed in accordance with the FIA Code of Practice, BS5839 and BS6266 where relevant. BS5839 - Used when the design mimics that of standard detection. ASD systems are used to directly replace point or other conventional detection methods for practical and/or financial reasons. BS6266 - Used when installing ASD systems with Electrical Equipment such as IT/Communication suites. Again design mimics that of conventional detection, however the use of High Sensitivity Smoke Detection (HSSD) systems are encouraged and in some cases demanded. Maximum coverage The maximum coverage of an ASD system is determined by the number of point-type detectors than can be replaced by an ASD device. This is a crucial factor in determining what savings can be made by installing an air sampling system. The coverage can be worked out simply by calculating how many sampling holes can be installed at a reasonable distance from each other (usually about 8 m). 4

ASD System Design Designing EN54-20 Compliant Systems If an ASD device has been correctly classified as Class A or B, this does not necessarily mean that it will satisfy the class specified in the project design. Labelling a device with a detection class simply indicates that a minimum project design with a single sampling hole corresponding to the specified class can be implemented. It is therefore important to check that the entire project design satisfies the desired detection class. 5

Fast, reliable project design The various manufacturers of air sampling smoke detectors have found different ways of ensuring that their systems conform to the detection classes specified in EN 54-20. The majority of the project design software available needs to produce detailed system plans to be able to make a reliable statement about the conformity. It is often the case, however, that not all project design parameters are known in advance. Particularly in the case of future extension of a feed pipe or an increase in the distance between two openings can lead to loss of conformity. WAGNER s TITANUS project design software, on the other hand, is designed to ensure that a reliable project design can be achieved in minutes - including the use of accessories. The software is based on worst-case project design and takes into account the configuration options within the scope of the defined project design limits. The intuitive software does not require any specialist training and quickly gives exact, easy to follow results. The software produces a conformity declaration for the detection categories specified by the selected project design in accordance with EN 54-20. Conformity declaration Specialist accessories There are a number of important EN54-20 approved accessories that can be incorporated into the final project design to aid operation and maintenance. Steam trap Blow through valves: A blow through system is used to clean the pipe system and/or the air sampling points in restricted areas. The deposits which form in the pipe system in very dusty applications are blown through by means of overpressure applied via check valves installed at the ends of sampling branches. Either a manual or automatic system can be deployed, depending how often the pipe system has to be blown through. Filters: These can be installed in the pipework to remove dust particles from the aspirated air in order to extend inspection time and reduce blow through intervals. Flame arresters: These in-line devices can be used to create an explosion-proof ASD system for use in hazardous areas. Steam traps: These can be installed for the draining of condensate from the pipe system. They contain a sintered metal filter. 6

Applications High Rack Storage Areas Industrial Production 7 pipe system can be easily integrated into the high rack storage construction better detection due to active air sampling throughout the entire height no interruption of operation for service and maintenance required easy access, therefore reduced costs for maintenance and service easy layout of the pipe system within the supporting structure of the production area suitable for extreme applications with high dust and dirt contamination installation of the detection unit at eye level maintenance and service can be carried out without any problems even in high halls with multiple ceiling conveyors

Clean Rooms Deep Freeze Storage safe smoke detection, even with forced air flow and high air speeds no air contamination within the production area due to active air sampling of the ambient air maintenance and service personnel do not need to enter the clean room better detection of slow smoke at low temperatures due to active air sampling possible icing of air sampling points is detected safely iced sampling points can be blown free no heating elements required Electrical Cabinets Lift Shafts optimum detection even with heat cushion due to active air sampling out of the cabinet possible monitoring of several cabinets with one air sampling smoke detection system no switch-off for servicing required, since the detection unit is located outside the monitored area installation of the detection unit outside of the danger area no interruption during maintenance required easy access for services and maintenance 8

Historic Architecture EDP Facilities no damage of elaborate ceilings hidden installation of the pipe system control unit hidden at accessible location individually adjustable sensitivity for each room ideal solution for air-conditioned EDP devices reliable detection by air sampling conduction to the detection unit adaptable to every cabinet and computer room design Libraries & Archives Saunas highly sensitive fire detection technology for very early smoke detection graded safety concept for protecting unique valuables almost invisible technology of the ASD systems as the air sampling is installed at the book shelves detection possible even up to temperatures up to 110 C reliable detection even with heat cushion under the ceiling no false alarms caused by condensate of water or ethereal oils almost invisible fire detection system 9

Conveyor Belts Paper Mills & Recycling layout of the pipe system at the frame construction of the conveying belt safe detection due to active air sampling throughout the entire length reliable detection even with changing ambient conditions insensitive against dust, dirt and humidity no false alarms caused by dust or condensate no soiling of the detection unit no operation interruption during maintenance Floor Voids Steel/Glass Architecture no risk of detector damage during cable distribution in the floor void applicable even for small heights of the floor void easy access for service and maintenance almost invisible pipes installed within the frame elements of the ceiling construction reliable detection even with heat cushion under the glass dome wide planning freedom for architects 10

WAGNER Product Range TITANUS - Smoke detection for any situation The performance, flexibility and functionality of the TITANUS product range mean they are used in a wide range of applications, from areas where traditional point detection is considered through to specialist installations where only air sampling solves the fire detection requirement. 11

TITANUS PRO SENS TITANUS TOP SENS Cost effective, universal air sampling solution for a broad range of applications. The modular device has 3 alarm levels, double knock detection and a range of accessories. TITANUS MICRO SENS High specification, fully featured air sampling system for a broad range of applications. The unit has graded alarms and a smoke level bar graph display. TITANUS SUPER SENS Compact and cost effective ASD for monitoring small to medium-sized spaces and equipment. With optional ROOM IDENT, the unit can monitor up to 5 rooms and identify the source of the alarm. High-end ASD for the most demanding smoke detection applications. The unit is highly-sensitive and provides very early smoke detection for areas with high levels of air dilution. TITANUS RACK SENS VisuLAN ASD system for server racks and control cabinets with automatic shutdown and extinguishing options. Central control and display for all TITANUS ASD systems 12

The WAGNER Advantage TITANUS - field proven ASD technology Thanks to their outstanding reliability, sensitivity and false alarm immunity, TITANUS air sampling smoke detection systems have been tried and tested in a wide variety of applications and are the first choice for many fire system designers and consultants. Advanced and unique features across the family ensure a TITANUS ASD solution is available for every smoke detection requirement. 13

Innovative detection technology Traditional ASD systems use an expensive laser light source to detect smoke in the detection chamber. When smoke particles are present the laser light scatters and is detected by light receivers in the chamber. TITANUS ASD products use a similar concept except that the expensive laser is replaced by a lower cost High-Power LED Light Source (HPLS). This approach is equally as sensitive and provides high quality detection to EN 54-20. However, the cost benefits mean that ASD can be used in a much wider range of applications. False alarm immunity LOGIC SENS is an advanced signal processing technology that analyses the smoke sample and provides the earliest possible smoke detection whilst safely eliminating false alarms such as theatrical special effects smoke and diesel fumes. Reliable operation PIPE GUARD is a unique monitoring system that detects if a sampling hole is blocked, a pipe is ruptured or if the air sampling unit has failed. This feature is vital in inaccessible areas where access is restricted and identification of individually blocked sampling points is essential. Wide operating temperature TITANUS air sampling smoke detection systems are approved for use in cold storage units at temperatures as low as -40 C. The upper temperature limit for site installations can be as high as +60 C. Silent running TITANUS Silent can be fitted to TOP SENS and PRO SENS products to produce a totally silent running system for applications such as domestic premises and offices where ambient background noise is low. Addressable smoke detection The TITANUS MICRO SENS can be fitted with ROOM IDENT to provide individual detection of up to 5 rooms or areas. The source of the fire can be identified providing a cost effective replacement for addressable point detection for demanding environments and smoke detection applications. Discrete air sampling WAGNER s capillary sampling hole can be mounted in a false ceiling, remotely from the sampling pipe. This ensures that smoke detection is discrete and does not distract from the décor. Areas such as detection cells also benefit from this discrete approach where conventional detection equipment has to be additionally protected against vandalism. 14

OxyReduct Removing the Threat of Fire All traditional forms of fire protection and extinguishing systems rely on a fire starting for them to work, so some damage is inevitable. In applications where any business disruption is unacceptable or archive/stock is invaluable a different approach is required. OxyReduct is the ultimate form of fire protection as it stops a fire from occurring in the first place. 15

How it works In order for a fire to occur there are essentially three fundamental elements that are required - fuel, heat and oxygen. Decreasing the concentration of oxygen in the air reduces the combustibility of all substances. An open fire cannot occur nor can it sustain itself if there is a lack of oxygen. Inert gas extinguishing systems have used this principle successfully for many years, but crucially there must have already been a fire for the extinguishant to be released. The ultimate form of fire protection is to prevent fires from happening in the first place. This is how OxyReduct differs from all other traditional fire detection and extinguishing systems. Fuel Heat Oxygen OxyReduct employs innovative technology that continuously reduces the oxygen level in a room by adding nitrogen to the air. The oxygen is reduced to a level in which most combustibles do not inflame and an open fire is impossible. Safe access OxyReduct does not prevent the area being used by people. The effects of lowered oxygen levels on the human body are well known and safety guidelines have been established that allow staff to enter or work in the protected area. Fuel Heat OxyReduct Atmospheric environment Nitrogen is used to inert the area as it is completely non-toxic in any quantity and is easily produced on site. Other benefits of Nitrogen are that it is electrically nonconductive and will not harm any product stored in the area. The Nitrogen being fed into the risk area is in fact fresh air with a 95% Nitrogen content. This prevents the air within the risk area from becoming stale and also prevents a build-up of carbon dioxide. The Nitrogen is not stored in pressurised bottles, but produced as required by the OxyReduct system to replace natural leakage in the risk area. This allows accurate control of the atmosphere within the risk and saves space. Applications OxyReduct is used where reliable fire protection is essential for the organisation's success. The application spectrum stretches from small IT rooms to 3 warehouses of 100,000m and more. OxyReduct installations have a critical advantage in areas with both a high concentration of goods and value. In highrack storage, deep freeze, paper or hazardous goods areas any fire would have catastrophic effects on the ability to deliver. OxyReduct is now a mature technology that has been adopted by over 200 organisations throughout Europe. When business continuity is of prime importance, OxyReduct can provide the ideal solution for fire protection. 16

Support Services Complete Design Service Installation Commissioning Service & Maintenance Training Demonstration Facilities WAGNER UK Limited Unit F South Cambridge Business Park Babraham Road Sawston Cambridgeshire CB22 3JH T: 0870 333 6116 F: 0870 333 4544 E: sales@wagner-uk.com www.wagner-uk.com