FAAST. Fire Alarm Aspirating Sensing Technology

Similar documents
FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspiration Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Aspir A ation spir P R O D U C T S

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

FAAST PRODUCT RANGE Aspirating Smoke Detection

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Aspiration Detection.

and Aspirating Smoke Detection

FAAST Beyond Standard Methods of Detection

Flexible Air-sampling Smoke Detection

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

Aspirating Smoke Detection for Duct Monitoring

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

1.1 SCOPE 1.2 APPROVALS. A. The Aspirating Smoke Detector shall be tested, approved and/or listed by: 1.3 CODE, STANDARDS, AND REGULATION

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

LaserFOCUS VLF-250 Engineering Specification

Open-area Smoke Imaging Detection (OSID)

FDA241, FDA221 Siemens ASD

ASPIRATING SMOKE DETECTION SYSTEMS

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Why Hart XL Aspirating Smoke Detection?

Open-area Smoke Imaging Detection (OSID)

FDA241, FDA221 Siemens ASD

465 ma, All relays active, all alarm levels displayed

Intelligent addressable fire alarm control panel

Aspiration Systems for Smoke Detection

Aspirated Smoke Detectors

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Intelligent Earliest Warning Aspirating Fire Detector

FAAST 7100X INSTALLATION AND MAINTENANCE INSTRUCTIONS. Document Colour Code Key: (refer to Page 28) SPECIFICATIONS: TABLE OF CONTENTS

FAAST XT 9400XA Fire Alarm Aspiration Sensing Technology

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)

Engineering Specification Guide VESDA-E VEP

SPEED, STABILITY, & RELIABILITY N EW! IntelliQuad TM PLUS Combination Smoke and Carbon Monoxide (CO) Detector

Installation and Operation Manual

TrueAlarm Analog Sensing

The Next Generation of VESDA Aspirating Smoke Detection Technology

TrueAlarm Smoke Detectors

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

The World s No. 1 Brand of Aspirating Smoke Detection

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Aspirating Smoke Detection for Large Area Coverage Applications

Aspirating Systems. Ducts. System Sensor Design Guide

Evolution Analogue Addressable Fire System

FAAST XS 7100X Fire Alarm Aspiration Sensing Technology

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Buys Time. Aspirating Smoke Detection

AUTROSAFE. An interactive fire detection system for larger vessels

Motorised Infrared Optical Beam Smoke Detector. User Guide

Buys Time. Aspirating Smoke Detection

Security Alarm Systems

ACP10 & ACP50 Security Systems

The World's No. 1 Brand of Aspirating Smoke Detector

Solution F2. Fire Alarm Control Panels one step ahead.

FAAST LT SET-UP AND TROUBLESHOOTING GUIDE. CONTENTS Introduction...1 Wiring up a FAAST LT unit...1. Setting the Fan speed...7

Motorised Infrared Optical Beam Smoke Detector. User Guide

FIRERAY 5000 range USER GUIDE

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

Desigo Fire Safety intelligent detectors for complete safety

LASER ASPIRATED SMOKE DETECTOR

AUTROSAFE 4 A new level in interactive fire detection systems

The World's No. 1 Brand of Aspirating Smoke Detector

Consultant Specification AGILE Wireless Fire Detection System

>WIRELESS> ALARM SYSTEM CR200

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

Metal Detection. High Performance Metal Detection Delivering Efficiency and Reliability SAFELINE

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Product Description...3 Communication Interface...4 Client Interface...4. Accessible Registers...4 Data Format...4

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

LEARNING SPECIAL HAZARD DETECTION TYPES

Multi-Point Peripherals

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

The World's No. 1 Brand of Air-sampling Smoke Detector

Quick Selection Guide Analog Addressable Fire Systems

ACTIVE INFRARED BARRIER

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fixed High Volume Water Spray System fireward.co.uk

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

SmartAlarm Annunciator

Reliably Advanced Extinguishing Control

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Reliably Advanced Extinguishing Control

security timeless design innovative products inspired technology

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Sensors (All Fully Customisable)

Early Warning Fire Detection Engineering

Transcription:

FAAST Fire Alarm Aspirating Sensing Technology

The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Configuration and Monitoring FAAST Fire Alarm Aspiration Sensing Technology is a new Very Early Warning Fire Detection solution with ground breaking immunity to false alarms. FAAST LT extends detection coverage into areas where standard detection methods are prone to failure or false alarm, or where maintenance is difficult. PipeIQ the all-in-one pipe design, configuration and monitoring software guides users through system design and provides full device configuration and ongoing system monitoring. PipeIQ is included free of charge with FAAST devices. False alarm immunity with very early warning, achieving sensitivity of 0.0015% obs/m. Multiple sensitivity levels available Dual source sensing technology (blue LED & red IR laser) to identify and eliminate nuisance particulates from the detection equation Unique three-stage filtration includes an aerospacedesigned and patented wing filter to prevent particles larger than 20 microns from entering the detection chamber, a replaceable filter to remove particles which have escaped and multi-angle and multi-wavelength optics to filter nuisance particles Internet / IP connectivity enables remote monitoring and management of the full system from anywhere in the world through internet browser, smart phone or mobile device. The detector can also e-mail status notifications to multiple addresses All-in-one Pipe IQ software provides an integrated solution for pipe network layout, system configuration and monitoring Field-proven laser smoke detection providing sensitivity up to 0.06% obs/m Achieve full management and control from the panel Ultrasonic airflow monitoring to reliably detect blocked sampling pipes in changing environmental conditions Fast and easy configuration and maintenance in areas where maintenance is costly or challenging All-in-one Pipe IQ LT software provides an integrated solution for pipe network layout, system configuration and monitoring Create simple pipe designs in only a couple of minutes using Pipe Wizard Use the Pipe by Pipe Design tool for more complex pipe networks requiring full customization Real-time event monitoring and configuration via device s onboard Ethernet connection Access to full current, live device status and historic logs Provides flexible trend graphs, reports and data storage options Translates device status into graphical format for analysis (model dependent) Incorporates a full built-in help guide for quick and easy troubleshooting Using PipeIQ, a designer can complete the pipe network layout, verify hole sizes and sensitivity and obtain a Bill of Material and Layout Report. 02 03

FAAST Delivers FAAST puts you in control When very early warning fire detection is essential The Information You Need To Protect Your Most Critical Business Assets FAAST has one focus. To protect people, mission critical facilities and high value assets by sensing the faintest traces of smoke, in a wide range of challenging environments. FAAST is a ground breaking aspirating solution designed to deliver highly accurate and discreet early warning fire detection. Using unique dual vision technology and intuitive features that allow access to data from anywhere in the world, the product outperforms other aspirating systems on the market. Intuitive Data Dual Vision. One Focus. FAAST provides you with the data you need to manage your environment. It includes 5 alarm levels, 10 pre-alarm particulate levels and a 10-level airflow pendulum which verifies that air is flowing effectively through the pipe network. It also includes a full range of fault indications. All of this information can be read quickly and easily on the device s intuitive integral display* or through a variety of remote devices. FAAST s dual vision sensing technology uses a blue LED to detect a wide variety of fires with extremely low concentrations of smoke and an infrared laser to identify nuisances (like dust) which can cause false alarms and downtime. Advanced algorithms interpret signals from both sources to meet one single focus to protect your facility, people and assets with the earliest and most accurate smoke detection available. *Multiple language cards available. See Ordering Information. Dual Vision. One Focus Stay Connected Quick Set-Up If there is a situation at your facility, you need to know about it instantly. FAAST s unique onboard Ethernet interface enables you to monitor the detector from any Internet browser, smart phone or mobile device with VPN capability. You can also configure the detector to deliver e-mail status updates to appropriate personnel. This means you will be advised of whatever you need to know to protect your facility no matter where you are. FAAST s all-in-one system configuration and monitoring software, PipeIQ, guides you through initial pipe layout and system configuration. Once the system is installed, it enables ongoing configuration and system monitoring from anywhere in the world, via the Internet, using FAAST s onboard Ethernet connection. The PipeIQ software is included with FAAST. 04 05

Key Features Detection as precise as 0.0015 %/m obs. Five alarm levels and two sensitivity modes provide application flexibility PipeIQ software provides intuitive system layout, configuration and monitoring all in one package Integral Ethernet interface enables remote monitoring and e-mail status updates Fault indictors provide a broad spectrum of events Unique air flow pendulum graph verifies pipe network functionality Particulate graph displays subtle environmental changes for early problem indications Dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement A single device protects up to 2,000 square metres Advanced detection algorithms reject common nuisance conditions Patented particle separator and fieldreplaceable filter remove contaminants from the system FAAST LT Fire detection for the toughest applications FAAST LT delivers a flexible solution for applications where standard detection methods are prone to failure or false alarm. Designed with the installer and end user in mind, the device serves a wide variety of applications where maintenance is difficult, other smoke detection methods are inappropriate due to harsh environments, or areas where aesthetics matters. Stay Connected If there is a situation at your facility, you need to know about it instantly. FAAST s unique onboard Ethernet interface enables you to monitor the detector from anywhere. 06 07

FAAST LT Delivers Features Beyond standard methods of detection FAAST Applications Quick Set-Up FAAST LT s main focus is applications where standard detection is not appropriate due to harsh environments, difficult access, tamper proofing or complex spaces. PipeIQ LT the all-in-one system design and configuration software, guides you through initial pipe layout and system configuration. Once the system is installed, it enables ongoing configuration and system monitoring via a USB connection. Great Indoors FAAST LT is a reliable and flexible solution for large public areas like shopping centres, airports, or stadia where evacuations are complex. It is also ideal for warehouses where access and maintenance is difficult and standard detection is not appropriate. The device allows access to these areas, reducing the cost of maintenance. FAAST LT also provides an alternative to beam detection where smoke stratification may occur. Restricted Access For areas such as prisons and public spaces where devices can be tampered with, FAAST LT can be installed outside of the protected area while air sampling points are located discreetly within. Extreme Environments FAAST LT is suitable for areas such as cold storage facilities or spaces with high-airflow, and environmental conditions outside the tolerance of typical fire detection technologies. The device can be installed in a temperate, easy-to-access location while sampling points are in the extreme environment. For different detection strategies choose from single, dual channel or co-operative detectors A single device protects up to 2,000 m2 High sensitivity laser optics Microprocessor controlled laser based optics delivering highest stability Ultrasonic flow detection for pipe flow measurement PipeIQ LT software provides intuitive system layout and configuration, all in one package Unique air flow pendulum graph verifies pipe network functionality USB interface Fault indictors provide a broad spectrum of events IP65 rating Dual channel units have two completely independent chambers with individual fans, filters, sensors and monitors Efficient maintenance filters and optics Technology for the Toughest Applications FAAST LT combines proven aspirating detection technologies and technical design excellence to deliver reliable smoke detection for the toughest environments.the device includes high sensitivity laser detectors, ultrasonic flow sensors, protected electronics and fully independent chambers to enable the device to reach the highest sensitivity required for Class C applications, up to 2000m2 and Class A applications up to 150m2. Ease of Installation and Maintenance FAAST LT is designed for efficient installation and maintenance. You do not have to worry about additional items such as brackets or relays since all of this is provided with the unit as standard. Sensors and filters are easily accessible for routine maintenance and an intuitive fault pendulum display allows rapid problem identification and solving. Discreet Detection When aesthetics matter, such as in museums, churches or mansions, FAAST LT provides a flexible, discreet smoke detection solution that is nearly invisible to the public. At the same time, it provides early smoke detection giving more time to protect high-value items from fire. Mission Critical * For environments such as small server rooms, where only a couple of detection points are required and the loss of downtime is extremely important, FAAST is the ideal solution. It provides early smoke detection to help facilities stay up and running 24/7 and prevents unnecessary activation of suppression systems. Single Channel Dual Channel *For larger mission critical applications consider using our FAAST product. 08 09

Tec Specifi cation Tec Specifi cation The FAAST Solution for Aspirating Detection The FAAST LT Solution for Aspirating Detection Physical Specification Physical Specification Electrical Specification s Height Width Depth Cable Access Wire Gauge Maximum Single Pipe Length Maximum Total Branched Pipe Length Maximum Air Inlet Holes Network Outside Pipe Diameter Internal Pipe Diameter Sensitivity Range Relays Event Log Communication Network Shipping Weight Electrical Specification s External Supply Voltage 33.7 cm 33 cm 12.7 cm 2.54 cm cable entry holes on top and bottom of unit 0.5-2.0mm 2 (12-24 AWG) 120m 320m 36 holes 25 mm 15-21 mm 0.0015 %/m. obs 20.5 %/m. obscuration 8 Changeover contacts, 3 AMP, programmable latching or non-latching 18,000 events stored Ethernet monitoring, 6 E-mail address alerts 5.26kg includes packing material 18-30 VDC Height Depth Width Maximum Single Pipe Length 403mm (including inlets and outlets) 135mm 356mm 100m Maximum Total Branched Pipe Length 160m per channel Maximum Air Inlet Holes 18 per channel Coverage Area up to 2000m 2 Sensitivity Range 0.07% obs/m Sounder outputs 1 per channel Interfaces USB Filtration Fan control Terminal blocks: power supply, relays, sounder outputs, external input; USB port; buttons (test, reset, disable) Standard USB cable for Type B USB connection Replaceable filter 10 programmable speeds Smoke Sensor (s) Optical laser point type External Supply Voltage 18.5-31.5 V Remote Reset Time 2s Power Reset 0.5s Avg. Operating Current Max. Average Operating Current 1 Channel Device: 170mA @ 24 VDC (excluding sounders) 2 Channel Device: 270mA @ 24 VDC (excluding sounders) 1 Channel Device: 360mA @ 24 VDC (excluding sounders) 2 Channel Device: 570mA @ 24 VDC (excluding sounders) Relay Contact Ratings 2.0 A @ 30 VDC, 0.5 A @ 30 VAC Operating Temperature Optical laser point type Humidity Range 10% to 93% (non condensing) IP Rating 65 Product Variants FL0111E Stand Alone 1 Channel 1 Detector Remote Reset Time Power Reset External monitor must be pulled low for a minimum of 100 ms 1 sec. FL0112E Stand Alone 1 Channel 2 Detector Avg. Operating Current Alarm 500 ma @ 24 VDC 650 ma All relays active, all alarm levels displayed. Voltage @ 24 VDC FL0122E Stand Alone 2 Channel 2 Detector Maximum Current Draw 650 ma Voltage at 18 VDC Environmental Specification s Operating Temperature 0 C to 38 C Sampled Air Temperature -20 C to 60 C Humidity Range 10 to 95% (non-condensing) IP Rating IP30 Coverage Area Up to 2000sq. m Air Movement 0-1,219 m/min. (20m s-1) 010 FAAST Fire Alarm Aspiration Sensing Technology 011

Honeywell Tel: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 Email: hlsuksalessupport@honeywell.com 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN