The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

Similar documents
WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

isense This could be the smartest room thermostat you ve ever used

Installation Instructions

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

Compact HRE Boiler Range. The smart choice for heating and hot water

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Flue & Flue Kits for NVx, VPC & NVS

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Suggested Schematics with Control and Power Wiring details

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Twin Wall Installation Instructions And Maintenance Guide

FCX FUEL OIL CONDENSING BOILER RANGE

Remeha Quinta 30. Technical information. High-efficiency. condensing boiler for. wall mounted. installation. Output: kw

Remeha Quinta 115. Technical information. Remeha Quinta 115. High-efficiency. condensing boiler for wall. mounted installation.

Sirius WH. Working towards a cleaner future

Remeha Quinta 45 and 65

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw

Remeha Quinta 85. Technical information. Remeha Quinta 85. High-efficiency. condensing boiler for wall. mounted installation.

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Direct Sales Tel: Fax: Technical Information Tel: Fax:

Flues and chimney systems

Sirius FS. Working towards a cleaner future

Chimney Renovation Kit

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Product Guide Gas-fired and solar thermal. heating and hot water solutions NEW. Greenstar Comfort controls

range W, Plus Condensing boilers kW Commercial & Industrial Boilers

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 310/610 ECO PRO RANGE FEATURES AND BENEFITS

TopGas Wall Hung Condensing Gas Boiler

P P Gas Fireplace. P See Thru

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

INSTALLATION INSTRUCTIONS FOR FLUE KIT

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

FireFlexmaster. A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee. 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT

ecomax pro High efficiency condensing boiler range for traditional systems

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

24V dc Terminals X4. 230Vac Terminals X V dc Electrical connections Volt free Room thermostat on/off

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

CNTENTS. 1Introduction

CLUB HE 18 INSTALLATION AND SERVICING INSTRUCTIONS TO BE GIVEN TO THE USER SEALED SYSTEM CONDENSING BOILER. G.C. Appliance No Club HE 18

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Hamworthy Fleet Horizontal Floor Standing. Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY

LBF RANGE BALANCED FLUED WATER HEATERS

Residential Heating Boilers

Flue Installation Manual

Installation and Servicing Instructions. Alpha GasSaver GS-2

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT

Remeha Gas 610 ECO. Technical information. Remeha Gas 610 ECO. High efficiency condensing. boiler with low NO X emission. Heat outputs: kw

EVOMAX CONDENSING. PRODUCT & FLUE GUIDE IDEALCOMMERCIALBOILERS.COM

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Trianco EuroStar Band A 15/20, 20/26 & 29/36kW For Balanced or Conventional Flue

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

EVOMAX CONDENSING BOILER

Worcester GB162 wall mounted gas-fired condensing boiler series

Installation and Servicing Instructions. Alpha GasSaver GS-1

EVOMAX CONDENSING BOILER

Hamworthy. Fleet Wall Hung. Condensing Boilers Natural Gas Outputs 40kW to 150kW 5 YEAR HEAT EXCHANGER WARRANTY

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

Flues and chimney systems

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Evolve 951 & Product specification pages

VPC Gas Cabinet Heater Range

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

Hamworthy Fleet Vertical Floor Standing. Condensing Boilers Natural Gas Outputs 80kW to 1050kW 5 YEAR HEAT EXCHANGER WARRANTY

CP+ Gas & Oil Cabinet Heater Range

VBX 18 & 30. Eden X Type INSTALLATION AND SERVICING INSTRUCTIONS OPEN VENT CONDENSING BOILER. SINGLE PAGES 20/9/10 09:58 Page 1

Copper-Fin GAS-FIRED BOILERS

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

Vent Supplement Ultra-80, -105, -155, -230 & -310

Instructions Manual CTB CTB 9407

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Linea ONE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Compact 24 SE. Standard efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. GC No

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

Ridge End. DA Cooks. Progressing Meeting No:2. Neptune Responses Mechanical. 2 nd November 2015

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

Instructions for Use Installation and Servicing To be left with the user HIGH EFFICIENCY CONDENSING

Transcription:

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT RECYCLABLE MATERIALS High efficiency wall hung condensing boiler with ultra low NOx emission QUINTA PRO RANGE OUTPUTS QP30: 8.0-31.4 kw QP45: 8.0-43.0 kw QP65: 12.0-65.0 kw QP90: 14.1-89.5 kw QP115: 16.6-114.0 kw SEDBUK RATED (QP30, QP45, QP65) REMEHA QUINTA PRO SELECTION, DESIGN AND INSTALLATION OF FLUE SYSTEMS

Quinta Pro Series flue options The Quinta Pro series of boilers have fan assisted flues and are supplied as standard with a concentric flue outlet/air inlet which is used for room sealed operation or for open flue (room ventilated) applications. An optional twin pipe fitting is available for the room sealed CLV system. The concentric system can be supplied for individual boilers for horizontal or vertical installation and because of the excess fan capacity of the boiler most flue lengths can be accommodated (depending on boiler model and actual route taken) which enables the installer to position the boiler almost anywhere in the building. Open flue or room ventilated systems can be installed as individual or combined flues and should discharge vertically with the flue terminating in a optional tapered cone but c/w bird guard. Care should be taken when siting the actual discharge point as a vapour plume will be visible when the boiler is operating (max flue gas exit temperature will be less than 75 C) and it is possible for water to drip to the ground from the terminal on horizontal installations which could turn to ice in freezing conditions. Recommendations Refer to latest relevant British Standards (Ref BS 5440-2 : Specification for installation and maintenance of ventilation for gas appliances not exceeding 70kW) (1st, 2nd and 3rd family gases) (Ref BS 5440-1 : Specification for installation of gas appliances to chimneys and for maintenance of chimneys not exceeding 70kW) (1st, 2nd and 3rd family gases) (Ref BS 6644 : Specification for installation of gas-fired hot water boilers of rated inputs between 70kW to 1.8 kw)(net)( 2nd and 3rd family gases) (Ref IGE/UP/10) Installation of flued gas appliances in industrial and commercial premises. It is the responsibility of the installer to install the flue to comply with the current regulations and standards. The data published in this leaflet is based on the latest information (at date of publication) and may be subject to revisions. It should be read in conjunction with the Quinta Pro Installation and Service Manual supplied with each boiler or available on request. We reserve the right to continuous development in both design and manufacture, therefore any changes to the technology or equipment employed may not be retrospective, nor may we be obliged to adjust earlier supplies accordingly. Flue components are constructed from unpainted aluminium/steel. Flue Terminals are painted as detailed in terminal diagrams. Plume kit external components are aluminium or plastic and are painted black. All flue components are CE approved. 2

Quinta Pro Series Flue outlet / Air inlet details The Quinta Pro Series boilers are supplied as standard with a Concentric Flue outlet / Air inlet connection which can be used for: 1. Room sealed operation using the concentric flue system (Flue within air duct) 2. Conventional/Open flue operation using single skin flue system connected to the inner concentric connection with the air supply taken from the boiler house via the outer concentric connection. FLUE GAS AIR IN This shows the optional Twin pipe Flue outlet / Air inlet connection and is used for Room sealed operation using the CLV flue system (air inlet and flue gas discharge from two pressure zones). Using single skin, water and gas tight flue system with single skin air tight air inlet system. FLUE GAS AIR IN 3

Quinta Pro 30 and 45 - Room Sealed, 80/125mm Horizontal Concentric Flue Kit Option QP01 (For use when the boiler/s are mounted on and flued through a rear outside wall) Typical single boiler installation - can also be used for multiple boilers but each must have its own flue system at a min 530mm centres and never immediately above another. For two boilers only it is also possible to install the external terminal wall plates touching each other. Centre line of Terminal 175mm Wall closure plate should be fitted to terminal before passing through hole in wall to ensure correct positioning 240mm Sq. 4 x 5mm Holes 204 Sq Clearance hole for Terminal through wall 130mm Note:140mm diameter recess 15mm deep required from the face of the inside wall face to allow clearance for the bend Cut Terminal on site to suit wall thickness Max 500mm Min 150mm Kit Parts KT026 1 x Bend MG87836 1 x Terminal MG87980 2 x Wall plates MG28926 Detail of the Horizontal 80/125mm Concentric Flue Kit Option QP01 (Part No KT026) 50mm insertion length into mating socket 110 BS RAL Colour 9016 / 7021 125 o/d 240 Sq. 145 95 4 80 o/d 90 Boiler short bend (80/125) 150-500 610 745 4 x 5mm holes 204 Sq HRS Room sealed terminal (80/125mm) PLEASE NOTE: All dimensions are in mm.

Quinta Pro 30 and 45 - Room Sealed, 80/125mm Horizontal Concentric Flue Kit Option QP02 (For use when the flue is discharged through a side wall left or right) Typical single boiler installation - can also be used for multiple boilers but each must have its own flue system and installed a Min of 530mm. centres horizontally and never immediately above another. For two boilers only it is also possible to install the external terminal wall plates touching each other. Clearance hole for Terminal through wall 130mm 188mm 240mm Sq. 250mm Additional components will be required to suit site (within boiler constraints) 4 x 5mm Holes 204 Sq Wall closure plate should be fitted to terminal before passing through hole in wall to ensure correct positioning Max 500mm Kit Parts KT027 1 x Bend MG87843 1 x Terminal MG87980 2 x Wall plates MG28926 Detail of the 80/125mm Horizontal Concentric Flue Kit Option QP02 (Part No KT027) 158 188 125 o/d 240 Sq. 208 80 o/d 50 150-500 610 745 4 x 5mm holes 204 Sq 90 o Bend (80/125) HRS Room sealed terminal (80/125mm) PLEASE NOTE: All dimensions are in mm. 5

Quinta Pro 30 and 45 - Room Sealed, 80/125mm Vertical Concentric Flue Kit Option QP03 (For use when the flue is discharged vertically through the roof) Typical single boiler installation - can also be used for multiple boilers, but each must have its own flue system and terminals separated a Min of 300mm if at the same height. Refer to the relevant British Standard if this is not the case. Weathering Slate Suitable for flat or pitched roof (60 o ) QP30/45-495mm Additional components required to suit site details (within boiler constraints) QP30/45/65/90/115 =100mm Kit Parts KT031 1 x Vertical Terminal MG87973 1 x Universal Roof seal Pack VE001 Detail of the Vertical 80/125mm Concentric Flue Kit Option QP03 (Part No KT031) Can be cut down on site to a minimum of 150mm Retain the difference between inner and outer 1 (57mm) (300mm) 10 RAL - 9016 RAL - 7021 (1364mm) Detail of Standard weathering plate for 100mm to 150mm flue (Part No VE001) flat or pitch roofs up to 60 Dn80 Dn125 80mm approx Cut down to suit dia. of Terminal in use 600mm X 500mm 6

Quinta Pro 30 and 45-80/125mm Room Sealed Calculation data to determine max flue runs (Calculation data based on flue products supplied by Remeha) Quinta Pro 30 80/125mm Quinta Pro 45 80/125mm Maximum overall flue run Metres 20 16 Reduction Length for each 45 bend Reduction Length for each 90 bend Metres 1 1 Metres 2 2 80/125mm Concentric flue system Components for Room Sealed Operation 125 o/d 'L' 125 o/d 100 min 500 max Retain 20mm diff. 50 80 o/d 80 o/d Cuttable length Part No MG87818 Standard length (cannot be cut) 'L' = 1000mm Part No MG87812 'L' = 500mm Part No MG87811 'L' = 250mm Part No MG87810 208 158 188 131 136 offset 111 145 95 110 125 i/d 80 o/d 50 80 o/d 50 80 o/d 126 i/d 90 o Bend Part No MG87843 45 o Bend Part No MG87842 90 o Boiler short bend Part No MG87836 210 115 60 ctrs Wall bracket Part No MG87863 Clamp band Part No MG8765 (one supplied with each component except MG87836) Internal Seal (80mm) Part No MG87181 PLEASE NOTE: All dimensions are in mm. 7

Quinta Pro 30 and 45 - Room Sealed, 100mm Two zone CLV Flue Kit Option QP04 (For use when the air inlet is drawn from low level and flue outlet discharged vertically in a different pressure zone). Typical single boiler installation - can also be used for multiple boilers, but each must have its own flue system. Please ensure that the overall route does not exceed the Max values. 100mm Aluminium single wall flue and air inlet system Flue outlet Fall to boiler T<36m Air inlet Fall from boiler Quinta Pro 30/45 two pipe adaptor plate is required to replace standard concentric fitting 100 / 80mm Reducers to adapt boiler to suit 100mm system if required. Kit Parts KT032 1 x Flue connection S100250 2 x Flue adaptor 80/100 MG87127 1 x Flue terminal PU001 1 x Air inlet PU002 Detail of the 100mm Two Zone CLV Flue Kit Option QP04 (Part No KT032) Only parts named are in the kit additional 100mm single wall pipe and bends, shown dotted will be needed to suit site requirements (overall length to be within boiler constraints) Flue terminal c/w bird guard Air inlet Guard 100-80mm Reducer x2 80mm 80mm Two pipe adaptor plate 8

Quinta Pro 30 and 45 - Two zone 100mm Room Sealed Calculation data to determine max flue runs For calculation data in regards to CLV (different pressure zones) installations please contact our technical department. 100mm single wall aluminium flue system components T 200 30 95 10 50 10 60 20 Air Inlet guard Part No. PU002 Flue terminal c/w bird guard Part No. PU001 'L' 100 o/d Standard length 'L'= 1000mm Part No. MG87062 'L'= 500mm Part No. MG87061 'L'= 250mm Part No. MG86060 105 76 125 80 o/d Reducer 80mm spigot to 100mm socket Part No. MG87127 Must be used on the Q30/45 flue connection to adapt to 100mm system 76 Note: 2 x 45 bends will off set to 71mm centres 105 90 o Bend Part No. MG87113 45 o Bend Part No. MG87103 25-55 mm Silicon seal ring Part No. MG87186 Mountng Bracket Part No. MG87193 8mm x 45mm Screw thread PLEASE NOTE: All dimensions are in mm. 9

Quinta Pro 30 and 45-100mm Conventional or Open Flue Systems Typical single boiler installation - can also be used for multiple boilers with each boiler having its own flue system. Please ensure that the overall route does not exceed the max values in table on page 11. Flue outlet 100mm Aluminium single wall flue system. Fall to boiler T<Max 36m Air from plant room 100 / 80mm Reducer to adapt boiler to suit 100mm system Detail of Standard weathering plate for 100mm to 150mm flue (Part No VE001) flat or pitch roofs up to 60 80mmappox Cut down to suit dia. of flue. 600mm X 500mm 10

Quinta Pro 30 and 45-100mm Conventional or Open Flue Systems (As the Boiler is fan assisted it makes no difference if the run is horizontal or vertical but should terminate vertically as shown on page 10). (Calculation data based on flue products supplied by Remeha). Quinta Pro 30 100mm Quinta Pro 45 100mm Maximum overall flue run Metres 40 40 Reduction Length for each 45 bend Reduction Length for each 90 bend Metres 1.4 1.4 Metres 4.9 4.9 NOTE: Table shows max length of flue (using 100mm) Greater distances can be achieved by using larger diameter flue - please refer to Remeha for further details. Top 200 30 95 10 50 Air Inlet guard Part No. PU002 125 'L' 10 60 20 Flue terminal c/w bird guard Part No. PU001 100 o/d Standard length 'L'= 1000mm Part No. MG87062 'L'= 500mm Part No. MG87061 'L'= 250mm Part No. MG86060 80 o/d Reducer 80mm spigot to 100mm socket Part No. MG87127 Must be used on the QP30/45 flue connection to adapt to 100mm system 105 76 76 Note: 2 x 45 bends will off set to 71mm centres 105 90 o Bend Part No. MG87113 45 o Bend Part No. MG87103 25-55 mm Silicon seal ring Part No. MG87186 8mm x 45mm Screw thread Mountng Bracket Part No. MG87193 PLEASE NOTE: All dimensions are in mm. 11

Remeha Quinta Pro 30 & 45 Plume Kits 80/125mm Flue Kit Option QP05 (Calculations based on products supplied by Remeha) Wall Depth - Max 500mm - Min 150mm Terminal inner and outer can be cut to suit. Note1: 140mm diameter recess 15mm deep required from the face of the inside wall face to allow if clearance for the bend. Note2: Both the air intake and flue outlet termination postions must comply with current regulations and British Standards. Flue can be taken directly through rear outside wall or discharged through a side wall left or right, both must be within the constrains in the table below. Core Drill Wall - 130mm Dia. Min 150mm Note: Can be extended with extra parts see table. 80/125mm Plume Management Kits 5 6 8 QP05 Part No. KT00302 PMK-Horizontal Terminal Kit 7 1. PMK Wall terminal 2. Boiler bend - not illustrated 3. Wall plates 4. 1000mm flue extension (80mm) 5. Support bracket (80mm) 6. 90 bend (80mm) 7. Flue outlet (80mm) 8. Bird guard Note: The horizontal terminal unit must be installed with the outlet pointing vertically upwards. External components are constructed of black PP (plastic). 80/125mm Plume Management details 1 3 Horzontial terminal kit installed 3 5 4 Quinta Pro 30 80/125mm Quinta Pro 45 80/125mm Maximum overall flue run Metres 37 23 Reduction Length for each Metres 1.96 1.96 45 bend Reduction Length for each Metres 2.25 2.25 90 bend The table shows the maximum lengths allowed which includes both the internal concentric 80/125mm and the external 80mm. The bend from the top of the boiler and the external 80mm bend have already been taken into account. Any bends used must be taken from the total using the table above, this applies to the internal 80/125mm and the external 80mm. The maximum horizontal run is 6metres. 12

80/125mm Plume Management Components Part details PMK-Horizontal Terminal - not supplied as a separate component MG82343 PMK-90 Bend (80mm) MG82344 PMK-Horizontal outlet (80mm) MG82341 PMK 1000mm Flue Extension piece c/w wall bracket (80mm) MG82342 PMK-45 Bend (80mm) MG82345 Bird Mesh (80mm) MG87191 PMK-Wall bracket (80mm) - not illustrated MG84460 Boiler Bend - not illustrated 13

Quinta Pro 30 and 45 - Multi boiler Installation on a combined header (For Conventional or Open Flue Systems). Typical multi boiler installation with the flue combined into a single header and riser. 80 mm Boiler connections Tapered cone c/w bird guard D H Quinta Pro 30/45 Multi boiler Installation connected to a common header and riser in H Height of riser in Metres Total 2 to 4 5 to 8 9 to 12 13 to 16 17 to 20 kw D Header and Riser diameter in mm 56 2 x QP30 115 110 110 115 115 84 3 x QP30 160 150 145 145 145 112 4 x QP30 185 175 170 170 170 80 2 x QP45 130 125 125 130 130 120 3 x QP45 180 170 165 165 165 160 4 x QP45 220 205 195 195 195 NOTE: Using 90 boiler connections into the header may result in larger headers and risers being required. Other multi boiler flue combinations for the Quinta Pro 30/45 may be available to suit different site conditions for further information please consult our technical department contact details can be found on our web site www.remeha.co.uk 14

Quinta Pro 30 and 45 - Multi or Single boiler Installation on a Flue Dilution system NOTE: Remeha Commercial are unable to offer a flue dilution system and recommends that the installer contacts a flue specialist to design and manufacture the system in accordance with the requirements of the British Standards and to comply with the guidelines illustrated below. Typical multi boiler installation for a flue dilution flue system showing the flue break necessary for all pre-mix boilers to prevent the dilution fan affecting the gas/air ratio control system in the boiler. 80mm Boiler connections Bellmouth 2 x D + 50mm D Opening in duct 2 x D 30mm Drain Typical Duct entry Detail 15

Quinta Pro 65, 90 and 115 - Room Sealed, 100/150mm Horizontal Concentric Flue Kit Option QP06 (For use when the boiler/s are mounted on and flued through the outside wall). Typical single boiler installation - can also be used for multiple boilers but each must have its own flue system. At a min 530mm centres and never immediately above another. For two boilers only it is also possible to install the external terminal wall plates touching each other. Centre line of Terminal 175mm Wall closure plate should be fitted to terminal before passing through hole in wall to ensure correct positioning 240mm Sq. 4 x 5mm Holes 204 Sq Clearance hole for Terminal through wall 155mm Note:170mm diameter recess 20mm deep required from the face of the inside wall face to allow clearance for the bend Cut Terminal on site to suit wall thickness Max 500mm Min 150mm Kit Parts KT206 1 x Bend MG87631 1 x Terminal MG87990 2 x Wall plates MG28927 Detail of the 100/150mm Horizontal Concentric Flue Kit Option QP06 (Part No KT206) 50mm insertion length into mating socket 150 100 115 BS RAL Colour 9016 / 7021 150 o/d 240 Sq. 100 o/d 90 o Boiler Short bend 100/150 150-500 600 800 HRS Room sealed terminal 100/150 4 x 5mm holes 204 Sq 16 PLEASE NOTE: All dimensions are in mm.

Quinta Pro 65, 90 and 115 - Room Sealed, 100/150 Horizontal Concentric Flue Kit Option QP07 (For use when the flue is discharged through a side wall left or right). Typical single boiler installation - can also be used for multiple boilers but each must have its own flue system and installed a minimum of 530mm. centres horizontally and never immediately above another. For two boilers only it is also possible to install the external terminal wall plates touching each other. Clearance hole for Terminal through wall 155mm 208 mm 240mm Sq. 260 mm Additional components will be required to suit site (within boiler constraints see table on page 19) 4 x 5mm Holes 204 Sq Wall closure plate must be fitted to terminal before passing through hole in wall to ensure correct positioning Max 500mm Kit Parts KT034 1 x Bend MG87890 1 x Terminal MG87990 2 x Wall plates MG28927 Detail of the 100/150mm Horizontal Concentric Flue Kit Option QP07 (Part No KT034) 50mm insertion length into mating socket 208 BS RAL Colour 9016 150 o/d 240 Sq. 228 150-500 100 o/d 90 o Bend 100/150 50 600 800 HRS Room sealed terminal 100/150 4 x 5mm holes 204 Sq PLEASE NOTE: All dimensions are in mm. 17

Quinta Pro 65, 90 and 115 - Room Sealed, 100/150mm Vertical Concentric Flue Kit Option QP08 (For use when the flue is discharged vertically through the roof). Typical single boiler installation - can also be used for multiple boilers but each must have its own flue system and separated a Min of 300mm if at the same height. Refer to the relevant British Standard if this is not the case. Weathering Slate Suitable for flat or pitched roof QP65/90/115-615mm Additional components required to suit site details (within boiler constraints) QP65/90/115 = 100mm Kit Parts KT038 1 x Vertical Terminal MG87969 1 x Universal Roof Seal Pack VE001 Detail of the Vertical 100/150mm Concentric Flue Kit Option QP08 (Part No KT038) Can be cut down on site to a minimum of 150mm Retain the difference between inner and outer 1 (65) (580) 10 RAL - 9016 RAL - 7021 (1735) Dn100 Dn150 VRS Room sealed terminal 100/150mm 80 approx Cut down to suit dia. of Terminal in use 600 X 500 18 All dimensions in mm

Quinta Pro 65, 90 and 115-100/150mm Room Sealed Calculation data to determine max flue runs. (Calculation data based on flue products supplied by Remeha). Quinta Pro 65 100/150mm Quinta Pro 90 100/150mm Quinta Pro 115 100/150mm Maximum overall flue run Metres 13 13 Reduction Length for each 45 bend Reduction Length for each 90 bend Metres 1 1 Metres 2 2 7 1 2 100/150mm Concentric flue system Components for Room Sealed Operation All dimensions are in mm 148.5 o/d 'L' 500 150 o/d 100 o/d 50 Cuttable length Part No MG87886 228 100 o/d 151 i/d 100 o/d Standard length 'L' = 1000mm Part No MG87883 'L' = 500mm Part No MG87882 'L' = 250mm Part No MG87881 208 50 90 Bend Part No MG87890 147 100 o/d 128 150 Offset 50 45 Bend Part No MG87891 150 100 100 o/d 115 150 i/d 90 Boiler short bend Part No MG87631 (clamp band not required) 210 115 60 cts Wall bracket Part No MG87915 Clamp band Part No MG8765 (one supplied with each component except MG87631) Silicon seal ring (flue side) Part No MG87186 19

Quinta Pro 65, 90 and 115 - Room Sealed, 100mm Two zone CLV Flue Kit Option QP09 (For use when the air inlet is drawn from low level and flue outlet discharged vertically in a different pressure zone). Typical single boiler installation - can also be used for multiple boilers, but each must have its own flue system. Contact our technical department for details. 100mm Aluminium single wall flue and air inlet system Max length see boiler technical booklet Flue outlet T< 36m Fall to boiler Air inlet Fall from boiler Kit Parts KT030 1 x Flue connection S101626 1 x Flue terminal PU001 1 x Air inlet PU002 Detail of the 100mm Two Zone CLV Flue Kit Option QP09 (Part No KT030) Only parts named are in the kit additional 100mm single wall pipe and bends, shown dotted will be needed to suit site requirements (overall length to be within boiler constraints) Flue terminal c/w bird guard Air inlet Guard 100mm 100mm Two pipe adaptor plate 20

Quinta Pro 65, 90 and 115 - Two Zone Room Sealed Calculation data to determine max flue runs For calculation data in regards to CLV (different pressure zones) installations please contact our technical department or refer to the installation and service manual. 100mm single wall aluminium flue system Components All dimensions are in mm Top 200 30 95 10 50 10 60 20 Air Inlet guard Part No. PU002 125 'L' Flue terminal c/w bird guard Part No. PU001 100 o/d Standard length 'L'= 1000mm Part No. MG87062 'L'= 500mm Part No. MG87061 'L'= 250mm Part No. MG86060 80 o/d Reducer 80 spigot to 100 socket Part No. MG87127 Must be used on the QP30/45 flue connection to adapt to 100mm system 105 76 76 Note: 2 x 45 bends wi ll off set to 71mm centres 105 90 Bend Part No. MG87113 45 Bend Part No. MG87103 25-55 mm Silicon seal ring Part No. MG87186 Mountng Bracket Part No. MG87193 8mm x 45mm Screw thread 21

Quinta Pro 65, 90 and 115-100mm Conventional or Open Flue Systems QP10 Typical single boiler installation - can also be used for multiple boilers with each boiler having its own flue system. Flue outlet 100mm Aluminium single wall flue system. Fall to boiler Air from plant room Detail of Standard weathering plate for 100mm to 150mm flue (Part No VE001) 80 approx Cut down to suit dia. of Flue in use and seal with silicone supplied 600mm X 500mm 22

Quinta Pro 65, 90 and 115-100mm Conventional or Open Flue Systems (As the Boiler is fan assisted it makes no difference if the run is horizontal or vertical but should terminate vertically as shown on page 22) (Calculation data based on flue products supplied by Remeha). Quinta Pro 65 100mm Quinta Pro 90 100mm Quinta Pro 115 100mm Maximum overall flue run Metres 27 24 19 Reduction Length for each 45 bend Reduction Length for each 90 bend Metres 1.4 1.4 Metres 4.9 4.9 1.4 4.9 NOTE: Table shows max length of flue (using 100mm) Greater distances can be achieved by using larger diameter flue please refer to Remeha Commercial technical department for further details. 100mm single wall aluminium flue system Components All dimensions are in mm Top 200 30 95 10 50 10 60 20 Air Inlet guard Part No. PU002 Flue terminal c/w bird guard Part No. PU001 125 'L' 100 o/d Standard length 'L'= 1000mm Part No. MG87062 'L'= 500mm Part No. MG87061 'L'= 250mm Part No. MG87060 80 o/d Reducer 80mm spigot to 100mm socket Part No. MG87127 Must be used on the QP30/45 flue connection to adapt to 100mm system 105 76 76 Note: 2 x 45 bends will off set to 71mm centres 105 90 Bend Part No. MG87113 45 Bend Part No. MG87103 25-55 mm Silicon seal ring Part No. MG87186 8mm x 45mm Screw thread Mountng Bracket Part No. MG87193 23

Remeha Quinta Pro 65, 90 & 115 Plume Kits 100/150mm Flue Kit Option QP11 (Calculation based on products supplied by Remeha) Wall Depth - Max 500mm - Min 150mm Terminal inner and outer can be cut to suit. Note1: 170mm diameter recess 15mm deep required from the face of the inside wall face to allow clearance for the bend. Note2: Both the air intake and flue outlet termination postions must comply with current regulations and British Standards. Flue can be taken directly through rear outside wall or discharged through a side wall left or right both must be within the constrains in the table below. Core Drill Wall - 155mm Dia. Min 150mm Note: Can be extended with extra parts see table. 100/150mm Plume Management Kits QP11 Part No. KT00303 (Rear and left or right exit) PMK-Horizontal Terminal Kit 1. PMK Wall terminal 2. Boiler bend - not illustrated 3. Wall plates 4. 1000mm flue extension (100mm) 5. Support bracket (100mm) 6. 90 bend (100mm) 7. Flue outlet (100mm) 8. Bird guard Note1: The horizontal terminal unit must be installed with the outlet pointing vertically upwards. Note2: The external components are constructed of black aluminium 100/150mm Plume Management details 1 3 PMK - Horizontal Terminal Kit Installed 3 5 5 6 4 8 7 Quinta Pro 65 100/150mm Quinta Pro 90 100/150mm Quinta Pro 115 100/150mm Maximum overall flue run Metres 20 17 Reduction Length for each 45 bend Reduction Length for each 90 bend Metres 1.2 1.2 Metres 2.8 2.8 11 1.2 2.8 The table shows the maximum lengths allowed which includes both the internal concentric 100/150mm and the external 100mm. The bend from the top of the boiler and the external 100mm bend have already been taken into account. Any bends used must be taken from the total above, this also applies to both the 100/150mm internal and 100mm external flue. The maximum horizontal run is 6metres. 24

100/150mm Plume Management Components Part details PMK-Horizontal Terminal - not supplied as a separate component MG81753 PMK-90 Bend (100mm) MG81754 PMK-Horizontal outlet (100mm) MG81751 PMK 1000mm Flue Extension piece c/w wall bracket (100mm) MG81752 PMK-45 Bend (100mm) Dn 100 MG82345 Bird Mesh 100mm MG87193 PMK-Wall bracket (100mm) - not illustrated MG84310 Boiler Bend - not illustrated 25

Quinta Pro 65, 90 and 115 - Multi boiler Installation on a combined header (For Conventional or Open Flue Systems). Typical multi boiler installation with the flue combined into a single header and riser. 100 mm Boiler connections Tapered cone c/w bird guard D H Quinta Pro 65, 90 and 115 Multi boiler Installation connected to a common header and riser in Series Open Flue H Height of riser in Metres Total 2 to 4 5 to 8 9 to 12 13 to 16 17 to 20 kw Combination D Header and Riser diameter in mm 122 2 x QP65 155 145 145 145 150 183 3 x QP65 220 200 195 190 190 244 4 x QP65 265 240 230 225 225 168 2 x QP85 175 165 160 160 170 252 3 x QP85 250 225 215 215 210 336 4 x QP85 305 270 255 250 245 214 2 x QP115 200 185 180 180 180 321 3 x QP115 285 255 240 235 235 428 4 x QP115 345 305 285 275 275 26 NOTE: Using 90 boiler connections into the header may result in larger headers and risers being required. Other multi boiler flue combinations for the Quinta Pro 65, 90 and 115 may be available to suit different site conditions for further information please consult our technical department contact details can be found on our web site www.remeha.co.uk

Quinta Pro 65, 90 and 115 Multi or Single boiler Installation on a Flue Dilution system NOTE: Remeha Commercial are unable to offer a flue dilution system and recommends that the installer contacts a flue specialist to design and manufacture the system in accordance with the requirements of the British Standards and to comply with the guidelines illustrated below. Typical multi boiler installation for a flue dilution flue system showing the flue break necessary for all pre-mix boilers to prevent the dilution fan affecting the gas/air ratio control system in the boiler. 100 mm Boiler connections Bellmouth 2 x D + 50mm D Opening in duct 2 x D 30mm Drain Typical Duct entry Detail 27

The data published in this technical sales leaflet is based on the latest information (at date of publication) and may be subject to revisions. It should be read in conjunction with our full technical brochure (available on request). We reserve the right to continuous development in both design and manufacture, therefore any changes to the technology or equipment employed may not be retrospective, nor may we be obliged to adjust earlier supplies accordingly. Issue 1 date: 01/03/11sj Remeha Commercial Head Office Remeha House Molly Millars Lane Wokingham Berkshire RG41 2QP T: 0118 978 3434 F: 0118 978 6977 E: boilers@remeha.co.uk www.remeha.co.uk Remeha is committed to carbon offsetting Designed and produced by Sans Frontiere Marketing Communications 01273 487 800 www.sansfrontiere.co.uk