Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

Similar documents
Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

Zep Dyna Clean Installation and Operator's Manual

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

INDUSTRIAL - AQUEOUS PARTS CLEANER EM5 5 GALLON BENCH TOP

Industrial Parts Cleaner Operator's Manual

Industrial Parts Cleaner with Manual or Auto Lid and Electric or Air Pump Operator's Manual

INDUSTRIAL - AQUEOUS PARTS CLEANER EM5000

INDUSTRIAL - AQUEOUS PARTS CLEANER

INDUSTRIAL - AQUEOUS PARTS CLEANER EM5000

INDUSTRIAL - AQUEOUS PARTS CLEANER EM1435A AIR OPERATED

INDUSTRIAL - AQUEOUS PARTS CLEANER EM6000

INDUSTRIAL - AQUEOUS PARTS CLEANER EM4000

Material Safety Data Sheet

FRONT BUMPER COVER - VIN RANGE: H18680->H99999 (G )

MATERIAL SAFETY DATA SHEET FOR MOISTUREGUARD FOR CCA. 1.0 Introduction NZS 5433:1999.

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

B.) Accident -- Any suddenly occurring unintentional event which causes injury or property damage.

! WARNING. Style # Laguna Ventless Rectangle Fire Table Owner s Manual. Restoration Hardware Customer Service:

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Material Safety Data Sheet

USER'S INFORMATION MANUAL

Style # Large River Rock Fire Bowl

Material Safety Data Sheet

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

HWX GAS BOILERS USER S INFORMATION MANUAL

Humidifier De-scaling Solution. and Neutralizer. Usage Instructions. IMPORTANT: Read and save these instructions. Before

ICE BANK DESCALER & ICE MACHINE CLEANER

SpectraPrime Color Primer Surfacer

Radiator Additive. ZetaLube. Description

3M MATERIAL SAFETY DATA SHEET 3M(TM) Micropore(TM) Surgical Tape 1530, 1530S, 1530B, 153NS, /03/2006

MATERIAL SAFETY DATA SHEETS

Automatic Water System Pump SERIES

Revision date: 22/4/2016 Date of print: 11/5/2016 Version: 1 Language: en-ca,us Page: 1 of 8

EMERGENCY PHONE: or (651) (24 hours)

3M MATERIAL SAFETY DATA SHEET 3M(TM) Transpore(TM) Surgical Tape Cat. # 1527 series, 1527S-1, 1527S-2 04/07/2006

SpectraSeal 2.1 VOC Color Primer Sealer

B-Nine WSG. Water Soluble Granule Plant Growth Regulator. Controls Height, Promotes Flowering of Plants

MATERIAL SAFETY DATA SHEET 3M Micropore Surgical Tape 1530, 1530S, 1530B, 153NS, /24/12

WORKPLACE SAFETY INSPECTION CHECKLIST

Model BIO436R-A and BIO536R-A BIOMATIC Heated Bioremediation Parts Cleaner Operations and Maintenance Instructions

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: Product Number:

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

1. Table of Contents VisiJet Materials Overview Disclaimer Ispropyl Alcohol (IPA) and Polypropylene Glycol

EMERGENCY PHONE: or (651) (24 hours)

Material Safety Data Sheet

3M MATERIAL SAFETY DATA SHEET 3M(TM) Durapore(TM) Surgical Tapes Cat. #1538 and 1538S series 02/27/2006

This MSDS has been compiled in accordance with - EC Directive 91/155/EC - OSHA's Hazcom Standard (29 CFR )

MATERIAL SAFETY DATA SHEET 3M Single Coated Medical Plastic Tape 1527L, 1527LX, 1527SP and 1527ENP 02/21/11

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET. FILE NO.001 NAME OF PRODUCT MSDS DATE: 02/12/2016 CATCHMASTER Brand Adhesive Devices

IMTRADE PICKER HERBICIDE ACTIVE CONSTITUENT: 300 g/l TRICLOPYR present as butoxyethyl ester 100 g/l PICLORAM present as hexyloxypropylamine salt

3.2. Household Chemical Emergencies

Certificate of Compliance. 1.2 ITEM NUMBER AND SIZES: ml, ml, ml, ml

V-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17)

MATERIAL SAFETY DATA SHEET 3M Durapore Surgical Tapes Cat. # L (with liner) and 1538S series 02/03/12

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

Safety In Chemistry. Identified Risks and Hazards

Material Safety Data Sheet Masonite TM Hardboard

Chemistry 11 Laboratory Safety Guidelines

Certificate of Compliance

CLEANING AND SANITIZING

COMMERCIAL. GUARANTEE: daminozide... 85% NET Contents: 500 grams, 25 kg 24 Hour Emergency Phone: (519)

Student Lab Procedures. Lab Safety Orientation

Pot Belly Black. Overview. Suitable Surfaces

R100 Oil-Less Refrigerant Recovery Unit

Industrial Descale Solutions & Descale Services

GBX GAS BOILERS USER S INFORMATION MANUAL

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

Emergency Response Procedures

PRODUCT SAFETY DATA SHEET

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

ATER SS. Ventless Ethanol Fireplace. User s Manual Installation Instructions

Risk Compendium for the Chemical Industry Chemical Handling and Blending Process

Inclyno 2 Sieve Shaker SV020. Impact Test Equipment Ltd & User Guide. User Guide

BONZI PLANT GROWTH REGULATOR COMMERCIAL. For Use on Container Grown Ornamental Bedding Plants and Plugs. GUARANTEE: Paclobutrazol...

MIT Emergency Response Guide

Kent Reef Carbon Material Safety Data Sheet

3.1. Substances Not applicable 3.2. Mixtures Name Product identifier % GHS-CAN Classification GHS-US classification

TAB. Ventless Ethanol Fireplace. User s Manual

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions

DEPARTMENTAL SAFETY ISSUES - SAFETY TECHNOLOGIST / INFECTION CONTROL PRACTITIONER

Lot: PO: Model # 2950 Sonoma Outdoor Fireplace Instruction Manual Sonoma-SD

LATA. Ventless Ethanol Fireplace. User s Manual Installation Instructions

Terraclor Flowable Terraclor FF

4-GALLON MOBILE PARTS WASHER

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

MATERIAL SAFETY DATA SHEET

Safety Data Sheet. according to Regulation (EC) No 1907/2006 WICKES SMOOTH MASONRY

Safety Data Sheet. according to Regulation (EC) No 1907/2006. SECTION 1: Identification of the substance/mixture and of the company/undertaking

SLS Etch Primer. 300g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin

Safety Data Sheet CONKLIN COMPANY, INC.

LIMA. Ventless Ethanol Fireplace. User s Manual Installation Instructions

Workplace FIRE SAFETY

Mats Only. Butane Cartridges Not Included. 12 Mosquito Repellent Mats Lasting 4-Hours Each TOTAL MOSQUITO 48PROTECTION

CLEANING AND SANITATION Policy Owner: Erica Tennessen Policy Originated by (program or department): Program Applicable Programs: All Programs

43 May cause sensitisation by skin contact. 67 Vapours may cause drowsiness and dizziness.

Transcription:

I. Introduction A. General Information Read and understand all labels, MSDS, and this instruction manual before use. The Industrial - Remote Reservoir Parts Cleaner is an economical, safe, and innovative system designed to clean parts, using a mineral spirits based solvent. This parts cleaner incorporates a " Remote Reservoir " design, which limits the loss of solvent through evaporation and also provides an additional fire safety feature. Many fire jurisdictions promote use of equipment incorporating this design feature. Check with your local fire jurisdiction for additional information. Install your parts cleaner on a flat level surface in an area provided with adequate ventilation. Avoid repeated or prolonged breathing of vapors. Use of compressed air to dry parts may cause a high concentration of vapors in the immediate area. Local exhaust ventilation should be used in areas of high vapor concentration. Provisions for determining and maintaining adequate ventilation are the responsibility of the operator. Do not allow the parts cleaner to operate unattended. Make sure the parts cleaner is connected to a properly grounded 110 volt, 60 HZ. electrical power source. This equipment is designed for use with mineral spirits based solvents with a flash point greater than 60 C. (140 F.). Use only mineral spirits based solvents. Do not use Flammable solvents. Do not add any other chemicals to the cleaning solvent including, but not limited to, kerosene, fuel oil, gasoline, chlorinated solvents, or detergents. The use of any other solvents could potentially cause a hazardous condition. Under certain conditions the solvent could burn. For your protection, a fusible link automatically closes the cover of the parts cleaner in the event that a fire occurs in the sink work area. The closed cover contains and smothers the fire inside the metal sink. Do not leave large objects in the parts cleaner or hang anything on the cover that could prevent it from closing in the event of a fire. Do not replace fusible link with any other device to hold cover up. Do not place heavy objects on edges or front of sink. Although this parts cleaner is designed to be stable, uneven weight distribution could cause a hazardous condition, over which the manufacturer has no control. Do not block drain or modify the equipment in any way. 1

B. Safety Industrial - Remote Reservoir Parts Cleaner Complete safety in use is dependent upon proper use and handling of the parts cleaner in your workplace. It is important that you follow the instructions provided in this manual. If you fail to read, understand, and follow all of the procedures in this manual, you may cause or suffer personal injury. II. Safety Instructions and information A. Fire In case of a fire: Use a Type ABC or Type BC fire extinguisher. Do not use water. Contact your local fire department. Do not use flammable solvents. This equipment is designed to be used with mineral spirits based solvents with a flash point greater than 60 C. (140 F.). Never mix other chemicals with the cleaning solvent, including but not limited to kerosene, fuel oil, gasoline, chlorinated solvents, or detergents. The use of any other solvents could potentially cause a hazardous condition. When cleaning carburetors or other fuel supplying components, remove all gasoline into a proper disposal container before placing the component into the parts cleaner. Gasoline has a lower flash point than mineral spirits solvent. If gasoline is added, the flash point of the solvent may be lowered. Do not spray aerosols into or around this machine. Install the equipment in an area away from heat, sparks, and open flame. Never put hot parts into the solvent. Do not obstruct the cover. It is designed to close automatically in the event of a fire. The safety link and cover closing mechanism must be intact. Do not substitute with any other type of cover positioning device. Do not leave large objects in the parts cleaner or hang anything on the cover that could prevent the cover from closing in the event of a fire. Do not block drain or modify the equipment in any way. 2

Do not leave solvent-soaked rags in parts cleaner, wadded up on workbenches, or in uncovered containers. Soak up all solvent spills with absorbent material. Remove all solvent-soaked material in accordance with regulatory requirements. B. First Aid (Medical instructions) 1. EYES: Contact may cause slight to moderate irritation. High vapor concentrations (<500ppm) are irritating to the eyes. For direct contact, flush eyes with water for 15 minutes. If irritation from vapors or mists develops, move victim into fresh air. 2. SKIN: Prolonged or repeated contact tends to remove skin oils, possibly leading to dermatitis. Remove contaminated clothing, wash skin with soap and water. If irritation or pain develops or persists, consult a physician. 3. INHALATION (Breathing): High concentrations of vapor or mist may be irritating to the respiratory tract and may have other central nervous system effects. Remove to fresh air immediately. Do not leave victim unattended. Consult a physician if necessary. 4. INGESTION (Swallowing): Low order of acute oral toxicity. Drink 4 to 8 ounces of water and seek medical attention. DO NOT induce vomiting. C. Environmental 1. Avoid spilling solvent. If solvent is spilled, clean it up immediately. Consult Material Safety Data Sheet for instructions on clean up and disposal. 2. Contain leaks promptly. Notify local environmental authorities if necessary. 3. Proper housekeeping in the area of the parts cleaner is the responsibility of the user. 4. Check with your local jurisdiction for any other applicable hazardous materials compliance requirements. 5. Do not remove devices designed to reduce solvent evaporation except to process work or to perform maintenance. This parts cleaner incorporates a " Remote Reservoir " design, which limits the loss of solvent through evaporation and also provides an additional fire safety feature. 6. For further information consult the Material Safety Data Sheet provided by the solvent supplier. 3

III. Installation A. Position the drum on a hard level surface in a well-ventilated area. B. Unpack the parts. C. Place the sink on its side. D. Hook the pump assembly to the bracket on the bottom side of the tank. E. Feed the pump cord through the large hole in the pump plate on the back of the machine, and snap the cord cover in the hole. F. Feed the hose from the pump through hole in the pump plate on the back of the machine, and attach to the hose-barb on the back of the sink. Secure with a hose clamp. G. Place the sink onto the drum. H. Place the strainer and grate in the drain hole in the bottom of the sink. I. Place the control box in the bracket on the right side of the machine. J. Using the screw and star-washer, fasten the control box to the control box bracket. K. Plug the pump cord and light cord (if equipped) into the receptacle on control box. L. Plug the power cord into a 115VAC/60HZ/15amp grounded receptacle. M. Fill solvent reservoir to the correct level as indicated by the table below. Use only mineral spirits based solvents with a flash point greater than 60 C. (140 F.). 1. Capacity Model E-216 = 37.9 L. (10 gal.). 2. Capacity Model E-230 = 75.7 L. (20 gal.). 4

IV. Operation Industrial - Remote Reservoir Parts Cleaner A. Avoid prolonged contact with hands. Use gloves or barrier cream. B. Wear protective safety glasses suitable to prevent solvent splashing into eyes. C. Wear a protective apron or garment to avoid absorption of solvent into clothing. D. Open cover of parts cleaner. E. Adjust solvent nozzle to direct flow into center of work area. F. Energizing the toggle switch located on the right side of the machine will start the flow of solvent. G. Adjust solvent flow over parts to be cleaned. H. Use of a stiff bristled brush to scrub parts while the solvent is flowing will maximize cleaning efficiency. I. Turn off unit when operation is complete. Do not allow unit to operate unattended. J. Close cover to reduce solvent loss due to evaporation. 5

6