ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

Similar documents
ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

GDM/FLM/STA/STG/STM/STR/T/TAC/THAC/TS/TSD/TVM Series Cabinets

WARRANTY LABOR CLAIM

R-290 SERVICE MANUAL SWF MODELS. Principals and Best Practices for servicing HC refrigeration equipment

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

Vacuum Gauge. Measures lower-than-atmospheric pressure Digital scales. microns psi in. Hg millibars pascals torr millitorr

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

R C O O L E R S ( C D H C S E R I E S )

R-407A R-448A R-449A

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

MASS. MARITIME ACADEMY

SERVICE MANUAL FOR MODEL RM-49

Harold Ag & Mobile Products

Aspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement.

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION

SERVICE MANUAL FOR MODEL RM-10

5. MVAC-like appliance include appliances using R22 refrigerant a. True b. False

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

icool Training: Service Technician Hydrocarbon (HC) Refrigerant Training QBD Cooling Systems Inc. TORONTO / BRAMPTON ONTARIO, CANADA

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

The Essentials Of Working With R-410A

Page 2 Draft Revision to the Australian Automotive Air Conditioning Code of Practice 2014

SERVICE MANUAL FOR MODEL RM-26

HVACR Refrigeration

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

10/4/2013. The Changing State of Refrigerants

Air Conditioning & Duracool Emery Stora

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Residential Piping and Long Line Guideline

410AREFRIGERANTTRANSITIONGUIDE

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Control of refrigerant gases during manufacture, installation, servicing

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

A/C COMPRESSOR OIL CHECKING

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

Guidance. Service of Hydrocarbon Refrigerant Equipment in a Retail Environment

The Industry s Most Complete Refrigeration Source

Chapter 2. Alternatives to HCFCs and their Characteristics

B. A. T. Basic Appliance Training

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

DESIGN STANDARDS SECTION 15600

The complete approach to the care and management of A/C & refrigeration systems

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

1998 Expedition/Navigator Workshop Manual

Low GWP alternative refrigerants to R404A

Gary Parker Refrigerants Product Manager

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Leak testing in the HVACR Industry

Heavy Duty Heater / Air Conditioner Model R-8545

TRUE TECHNICAL SERVICE MANUAL - ALL MODELS. WARRANTY

AUTOMOTIVE HEATING AND

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

OPERATION & MAINTENANCE MANUAL AC860

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Welcome and thank you for participating. The Mobile Air Conditioning Society (MACS) was founded in 1981 and its members consist of technicians,

Caresaver Universal Refrigerant Recovery Unit

Climate Control System

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

OPERATING INSTRUCTIONS AND OWNER S MANUAL

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

Service. 18, 21, & 22 Cu. Ft. Bottom Mount Refrigerators

Air Conditioning Repairs: Maintenance Required

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

SERVICE BULLETIN A

Refrigerant changeover guidelines

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

Ductless Split Air Conditioner

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Air Conditioning Operation and Troubleshooting Matt Dunham

Safe Conversion and Servicing Practices for Refrigeration Appliances using Hydrocarbon Refrigerants

SERVICE NUMBER: SERV-351

Desiccants & Driers. By Norm Christopherson

Energy Saving & Eco-Friendly Refrigerant

Refrigerant Recovery Unit, Model RRU134

APPLICATION & SERVICE GUIDE

General Service Bulletin

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Progressive Safety Services LLC 2

OPER LV Wheeler Way

The natural solution for domestic refrigeration

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

USING R-134A REFRIGERANT

Refrigeration Supplies

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Transcription:

hydrocarbon ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290 974280

INDEX Why R-290... 1 Best Alternative... 2-3 FAQ... 4-7 Labeling... 8-10 The Difference in R-290 vs. R-134a/R-404A... 11-17 What s the Difference in Servicing... 18-26 What s the Difference in Tools... 27-29 R-290 Tools... 30-31 Contact Info... 32 Why HYDROCARBON Refrigerant Reason #1: The EPA has mandated a ban on HFC Refrigerants R-134a and R-404A by 2020 -Stand-Alone Medium Temperature Commercial Refrigerators Beginning in 2019 -Stand-Alone Low Temperature Commercial Freezers Beginning in 2020 Reason #2: Significant New Alternative Policy SNAP approval from EPA -December 2011 1

WHY R-290 WHY R-290 WHAT IS THE BEST ALTERNATIVE? R-290 WHY IS R-290 THE BEST ALTERNATIVE? NATURAL, NON-TOXIC, NON-OZONE DEPLETING AND LOW GLOBAL WARMING POTENTIAL BETTER THERMODYNAMIC EFFECIENCIES More energy efficient / lower carbon footprint / less electrical operating cost MATERIAL PROPERTIES AND SYSTEM SIMILARITIES MAKE HC s BEST ALTERNATIVE TO HFC s. RECOVERY OF REFRIGERANT NOT NECESSARY Easier to service and dispose of at end-of-life WHY IS R-290 THE BEST ALTERNATIVE GLOBAL-WARMING POTENTIAL (GWP) is a relative measure of how much heat a greenhouse gas traps in the atmosphere. It compares the amount of heat trapped by a certain mass of the gas in question to the amount of heat trapped by a similar mass of carbon dioxide. Refrigerant GWP ODP R-404A 3922 0 R-134a 1340 0 R-290 Propane 3 0 *For Reference: Carbon Dioxide has a GWP of 1 HC OFFERS 45-60% DECREASE IN CHARGE SIZE COMPARED TO R-134a/R-404A SAFE / PROVEN TECHNOLOGY USED AROUND THE WORLD 2 3

R-290 FAQ What do I need to know to service HC equipment? R-290 Frequently asked Questions 1. Do you need any specialized training to service R-290? No. The EPA has ruled specialized training is not required but is recommended. 2. Where do I go for training? True Manufacturing recommends contacting Refrigeration Service Engineers Society to inquire about their training program. The e-mail address for this is www.rses.org. 3. What tools are needed to service HC cabinets? There are only two specialized tools that are required for servicing HC equipment. A combustible gas meter /R-290 leak detector and a safety placard. True has developed a HC service kit that includes the two specialized tools and other tools that we suggest be used. Kit# 992987 LMc 6/2015 4 5

R-290 FAQ R-290 Frequently asked questions 1. Is there a maximum charge amount for commercial applications with R-290? Yes. You can only have a maximum charge amount of 150 grams (5.3 ounces) in each refrigeration system. For example, GDM-10 has a charge amount of 1.9oz 2. Are there special markings on a cabinet built using R-290? How will I be able to tell if the system I m working on is built with R-290? Yes. The indicators are: The serial number tag will indicate the type of refrigerant. The unit will have multiple labels stating that it is built with an HC/R-290 refrigerant. The unit will also have the process sleeves colored red. ONLY REFRIGERANT GRADE R290 SHOULD BE USED WHEN SERVICING HC EQUIPMENT. Standard propane does not meet the purity/moisture content needed for a Refrigeration System! R-290 does not have the odor additive in it that standard propane does. 3. Will I need different gauges to use with an R-290 system? No. The 134a manifold set can be used. Due to the small system charge amounts we suggest the use of the shortest hoses possible. Twelve inch hoses are included in our service kit. 4. Are there any specialized tools needed to service an R-290 refrigeration system?yes. The two specialized tools are listed below. a. A combustible gas meter/r-290 electronic leak detector. This is available through most HVAC supply houses. It is also available through True Parts. True Manufacturing Part Number 965087. b. A safety placard advising of no smoking or open flames. Standard refrigeration tools are still needed: Pinch Off Tool, Nitrogen, Vacuum Pump, Micron Gauge, Torches, Soap Bubbles, Manifold Set, and Tube Cutter. 5. Does the R-290 refrigerant have to be recovered? No. The EPA has ruled that an R-290 system can be vented into the atmosphere. 6. How do you leak check an R-290 system? For the most part you would leak check an R-290 system the same way you would a R-134a or R-404A system with a couple of exceptions. You can still use a bubble solution or an ultrasonic leak detector as well. We would also recommend using oxygen free dry nitrogen with a trace gas not exceeding 200PSI. -Exception #1 is you cannot use a halide leak detector on a R-290 system. -Exception #2 your electronic leak detector must be designed specifically for combustible gas. 7. Where can I get R-290 refrigerant? For use on True warranty repairs you can get this refrigerant directly from the True parts department. You can also source this refrigerant from an HVAC supply house or a company that sells gases and welding supplies. Note: If you are getting refrigerant somewhere besides True make sure you are purchasing refrigerant grade propane R-290. 8. What is the difference between R-290 and standard propane that you can purchase from a hardware store? R-290 has a much higher purity level. This level is greater than 97.5%. R-290 has a low moisture content. Moisture will damage the refrigeration system and components. Also, there is no scent added to R-290 which is added to standard propane. 9. Can I retrofit any cabinet to HC/R-290 refrigeran No the EPA has ruled that the retrofitting of any existing equipment is prohibited. 10. Can the same parts be used to service a hydrocarbon cabinet that are used on a R-134a/R-404A cabinet? Not necessarily. We suggest using OEM parts by specific model number. Parts used on hydrocarbon cabinets must have specific UL certification for non-sparking parts True Technical Service World Headquarters: O Fallon, Missouri, USA phone: 1-855-372-1368 Service Department Hours of Operation email: service@truemfg.com 7:00-7:00 CST Monday-Thursday, 7:00-6:00 Friday, 8:00-12:00 Saturday 6 LMc 6/2015 7

SPECIAL LABELING HYDROCARBON LABELING WHERE WILL THESE BE FOUND? EXAMPLES EXTERIOR BACK LEFT INTERIOR SERIAL TAG Is Special Labeling on Equipment Required? CONDENSER COIL SHROUD CONDENSING UNIT AREA SIDEWALL YES EXTERIOR BACK RIGHT INTERIOR EVAPORATOR TOP/COVER 8 9

SPECIAL LABELING ALL PROCESS TUBES MUST HAVE PMS #185 RED SLEEVES What s the Difference in R-290 vs. R-134a/R-404A CABINET / COMPONENTS NOTE: PARTS USED ON HC CABINETS MUST HAVE SPECIFIC UL CERTIFICATION FOR NON SPARKING COMPONENTS Red sleeves must always be reinstalled if removed during service 10 11

COMPONENTS COMPONENTS ELECTRICAL CONNECTORS Per UL Regulation Standard #471: All electrical connectors must meet a minimum pull force requirement. ELECTRICAL SYSTEM - SPARK FREE COMPONENTS COMPRESSOR RELAY Wire Nut Crimp Connector R-134a/R-404A R-290 Not approved for usage on Hydrocarbon / R-290 systems. R-290 * All covers should be in place Replacement Connectors supplied by True meet UL Standard #471. NOTE: PARTS USED ON HC CABINETS MUST HAVE SPECIFIC UL CERTIFICATION FOR NON SPARKING COMPONENTS 12 13

COMPONENTS COMPONENTS ELECTRICAL SYSTEM - SPARK FREE COMPONENTS ELECTRICAL SYSTEM - SPARK FREE COMPONENTS TEMPERATURE CONTROL - R-290 FAN MOTOR(S) - R-290 UL CERTIFICATION All motors used by True pass the HC standards for non sparking components. Mechanical LAE Electronic Control R-290 * Contacts are enclosed Sollatek Electronic Control Danfoss Electronic Control NOTE: PARTS USED ON HC CABINETS MUST HAVE SPECIFIC UL CERTIFICATION FOR NON SPARKING COMPONENTS 14 NOTE: PARTS USED ON HC CABINETS MUST HAVE SPECIFIC UL CERTIFICATION FOR NON SPARKING COMPONENTS 15

COMPONENTS SNAP How Do I Know If the Parts I m Using are HC/R-290 Compliant? IS SPECIALIZED TRAINING REQUIRED? NO Order OEM parts through True s Parts Department: Specialized training is recommended but not required for service providers. For online training contact: www.rses.org 1-800-424-8783 16 17

SERVICING NITROGEN PURGE HYDROCARBON / R-290 SPECIFIC What s the Difference in Servicing HC Systems BRAZING PROCEDURES Using oxygen free dry nitrogen set pressure to 3-5 PSI & purge for 2 minutes prior to brazing. Continue purging nitrogen through system until all brazing is complete. The processes used to service HC systems are very similar to current HFC systems (R-134a & R-404a) Procedure required for servicing R-290 equipment. WHY IS PURGING W/ NITROGEN REQUIRED? To displace any trapped refrigerant in the system. 18 19

TOOLS TOOLS HYRDROCARBON / R-290 SPECIFIC TOOLS NO LONGER NEEDED FOR HC/R-290 SYSTEM TOOLS USED SPECIFICALLY FOR HC/R-290 SYSTEM 1. 2. 1. Safety Plackard 2. Combustible Gas Meter Inficon Gas Mate Model 718-202-GI (True Part# 965087) HFC recovery system NOTE: HC VENTING APPROVED BY EPA 20 21

SAME PROCEDURES USED WITH ALL REFRIGERANTS INCLUDING HC/R-290 Good refrigeration practices will always start with good detective work to find out what caused the failure so we can eliminate the possibility of a repeat failure. Below is a step by step set of procedures we would recommend is followed when repairing a refrigeration system. Before opening the refrigeration system remember that POE oil is very hydroscopic and absorbs moisture very quickly. You should not leave the system open to the atmosphere for more that 15 minutes. Any vacuum that exists before any repair should be broken with nitrogen to avoid moisture being pulled into the system. ALWAYS CHANGE THE DRIER WHENEVER THE REFRIGERATION SYSTEM HAS BEEN OPENED. Recover the refrigerant from the system. The introduction to the refrigeration system of anything other than a flushing agent, nitrogen, refrigerant, or oil is prohibited. Remove the faulty refrigeration component and filter drier by cutting them out with a tubing cutter. (We would recommend this method over removing with a torch since it may destroy the evidence of what may have caused the failure or signs of oil contamination.) If you are changing a component keep the system closed up with plugs or caps to reduce moisture contamination. Manufacturing BUILDING THE FINEST COMMERCIAL REFRIGERATION-TRUE, The Best of the Cold Ones Good Refrigeration Practices If the oil shows signs of contamination or there was a restriction in the system, all of the oil must be removed and replaced. This can be done by flushing the entire system with nitrogen, removing all the oil in the compressor, and in the accumulator, measure all of the old oil in a measuring cup and replace the exact amount you removed with the new oil. Now that the system has been cleaned up, install the new compressor. Please also remember that the system should not be opened more than 15 minutes. Now place a nitrogen charge in the system to check for any leaks. Use maximum 200 PSI. Release the nitrogen charge down to about 2 pounds of positive pressure. Start pulling a vacuum as soon as possible to help remove any moisture from the system. Remember that any moisture that is absorbed by the POE oil cannot be removed and we must start the process over. SERVICING SAMPLE OF GOOD REFRIGERATION PRACTICES Use the shortest hoses on your gauges as possible (because of smaller refrigerant charge). Bleed refrigerant back into system when removing line taps. Take a look at the filter drier and the components that have been removed for signs of oil breakdown, foreign objects like desiccant from drier, metal pieces from valves, etc. When replacing a compressor make sure to also remove all old oil from the system. Be sure to pierce a hole (approx 1/8 ) in the bottom of the accumulator so we do not leave contaminated oil in the system. After blowing this out with nitrogen, be sure to braze the hole closed. Be sure and test the oil from the refrigeration system for contamination using the proper test kit for the type of oil. Change vacuum pump oil regularly to ensure the deepest vacuum your pump is capable of. Using a micron gauge, pull the system down to hold a minimum of 500 microns. See if the system will hold this micron with the gauges closed and the pump switched off to test for leaks or moisture. Once the system is evacuated, weigh in the proper charge as a liquid only on the high side of the refrigeration system. Test run the unit and check for proper operation. ANY NITROGEN ADDED TO THE SYSTEM SHOULD NOT EXCEED 200 PSI. PLEASE CALL TRUE TECHNICAL SERVICE WITH ANY 22 QUESTIONS REGARDING THE ABOVE PRACTICES. SAME PROCEDURES USED WITH ALL REFRIGERANTS INCLUDING HC/R-290 23

SERVICING SERVICING GOOD REFRIGERATION PRACTICES CHARGING THE SYSTEM Micron Gauge - Make sure to pull a 500 micron vacuum before doing service on a system. Ensure that the system has been leak checked. Evacuate system to a minimum 500 micron. Weigh in the correct charge. Leak check the system again. Bleed the refrigerant from the high side hose to the low side hose. Carefully disconnect the hoses, to limit the refrigerant loss. Remove line taps. SAME PROCEDURES USED WITH ALL REFRIGERANTS INCLUDING HC/R-290 SAME PROCEDURES USED WITH ALL REFRIGERANTS INCLUDING HC/R-290 24 25

SERVICING SEALING THE SYSTEM We recommend removing line taps from the system. Use a pinch off tool prior to sealing the ends of the process tubes. Thoroughly leak check process tube ends before brazing. What s the Difference in the tools used? SAME PROCEDURES USED WITH ALL REFRIGERANTS INCLUDING HC/R-290 26 27

TOOLS TOOLS TOOLS USED FOR ALL SYSTEMS INCLUDING HC/R-290 TOOLS USED FOR ALL SYSTEMS INCLUDING HC/R-290 GENERAL PRECAUTIONS All appropriate and necessary tools and equipment are available to include a CO 2 or dry-power type fire extinguisher. This procedure needs to be followed when working on any system. 1. Torches 2. Manifold set 3. Vaccuum pump 4. Oxygen free dry nitrogen 5. Scale 6. Micron guage 7. Pinch off tool 8. Temporary line taps 9. Tubing Cutter 28 29

R-290 TOOLS R-290 SERVICE KIT Kit# 992987 R-290 TOOLS 1. 2. 3. 4. KIT INCLUDED 1. COMBUSTIBLE GAS METER Inficon Gas Mate Model 718-202-GI (True Part# 965087) 2. Safety Plackard 3. Charging Valve 4. Pinch off tool 5. 12 Refrigeration hose FOR KIT CONTACT TRUE S PARTS DEPARTMENT: 1-800-424-8783 5. 30 31

NOTES For any other questions related to R-290, please contact True Technical Service CONTACT: Email: service@truemfg.com Direct Line 855-372-1368 Hours of Operation: Mon - Thurs 7:00 AM - 7:00 PM (CST) Fri 7:00 AM - 6:00 PM (CST) Sat 8:00 AM 12:00 PM (CST) 32 33

hydrocarbon ENERGY EFFICIENCY PERFORMANCE SAVINGS True Technical Service World Headquarters: O Fallon, Missouri, USA Service Department Hours of Operation: 7:00-7:00 CST Monday-Thursday, 7:00-6:00 Friday, 8:00-12:00 Saturday Phone: 1-855-372-1368 Email: service@truemfg.com 974280 AN 11/15