MODELS SP & CSP. Ceiling & Inline Cabinet Exhaust Fans. Making a Sound Difference with Silent Solutions. Ceiling. Inline.

Similar documents
5 year fan housing and motor warranty

Utility and Centrifugal

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Modular Supply Make-Up Air Unit

Indirect Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air

August 2004 AB0804. Accessories Book. Fantech I Your Ventilation Solutions Company

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

ZEPHYR Ceiling Exhaust Fans

ZEPHYR Ceiling Exhaust Fans

Energy Efficiency (CFM/Watts)* Watts PC /31 0.1/ / / / /63 <0.3

Insulated Ventilators. Operating Instructions & Parts Manual

March 2003 AB0303. Accessories Book. Fantech I Your Ventilation Solutions Company

Featuring Vent Lights and Premium Grilles

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION (15833) - HVAC POWER VENTILATORS

for MODEL KSU MAKE-UP AIR UNITS

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Plenum Fans. Model HPA. Direct Drive

KIC Air Curtains. Technical Guide

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Outside Air Requirements... SOLVED!

Make-Up Air Systems. Performance. Model DGK, DG, DGX

Air in Motion. Fan Guide Book. January 2001 FB-0101

Residential Balanced Ventilation Systems

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Bathroom Ventilation

Description. Construction

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

KUH. Horizontal Unit Heater. Applications. Description

Gas-Fired Unit Heaters Commercial & Industrial

EHH SERIES DRAW THROUGH FAN COILS CFM

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

RP, GP, XP Pro Series Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Energy Recovery with Cooling and Heating

Installation, Operation, and Maintenance Manual

Energy Recovery with Cooling and Heating Model ERCH

A. Codes and Standards that are Standard at the University:

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

VERTICAL FAN COIL UNITS

PA 500/1100V Ultra Quiet Ventilation Fan

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Heating Products M arch 2012

Cabinet Unit Heaters Steam / Hot Water

Caution: The fans must not be used in bath or shower enclosures.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Product Specifications. Vertical Floor Consoles By First Co.

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

SAFETY AND INSTALLATION MANUAL MODEL 8100

M Series Fan Filter Units

Residential Fans & Air Purifiers

IMPORTANT SAFETY INSTRUCTIONS

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Understanding Fan System Effects

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

For performance and dimensional data, see back page.

Air in Motion. Fan Guide Book February 2004 FB-0204

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Advance Release September 2009

Installation, Operation and Maintenance Manual

Modular Heating & Ventilating Unit Model IGX-HV

RP / RPc Series Installation Instructions

QUICKSHIP PROGRAM. Twin City Fan QuickShip

SeasonMaker ThinLine Fan-coil Units

SF180 Installation Instructions

Ultra SERIES. BroanUltra.ca. Broan-NuTone Canada Inc Tristar Drive Mississauga, Ontario L5T 1H /12

SECTION AIR DUCT ACCESSORIES

Submittal Data Performance Data Electrical Data

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

DOMEKT. Heat Recovery Air Handling Units

GreenJet Transfer Fans

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Deluxe Oil-Filled Heater. Heating Capability: 1,000 sq. ft

SECTION AIR HANDLING UNIT

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

1.1 This section applies to air handling units for HVAC Systems.

Ultra SERIES. A revolution in ventilation fan technology

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Heat Recovery Air Handling Units

Installation, Operation and Maintenance Manual

Bathroom Exhaust Fan/Fluorescent Light Combination

Technical and Dimensional Data. Saf-T Vent SC Plus

Transcription:

MOLS SP & SP eiling & Inline abinet xhaust Fans Making a Sound ifference with Silent Solutions eiling Inline R November 00

eiling and abinet xhaust Fans Great things come in small packages, as do our ceiling fans (Model SP) and cabinet fans (Model SP). e assured when you buy any Greenheck product, you are getting a quality product at a competitive price. In fact, we guarantee our ceiling and cabinet exhaust fans with a year warranty. We offer the most comprehensive ceiling and cabinet exhaust fan line in the commercial market. We are your market leader! enefits Low sound ompact size ompetitive price roadest performance selections in the industry Go Inside the Numbers Greenheck has been providing solutions for over 0 years. Preferred to over the competition Number in product quality and reliability. Number in customer satisfaction and after-sale customer service support. More than 00 times a day a new ceiling fan is put into service. year warranty. SP fans are designed for ceiling mounted applications. Greenheck certifies that the SP and SP models shown herein are licensed to bear the M seal. The ratings shown are based on tests and procedures performed in accordance with M Publication and M Publication and comply with the requirements of the M ertified Ratings Program. Models SP and SP are listed electric fans (UL/cUL 0). eiling xhaust Fans are also UL Listed for above bathtub/shower with GFI branch protected circuit. File no. 99. SP fans are designed for inline remote mounted applications. Leading dge Technical Support When you need extensive product information look no further. Greenheck products are supported by the industry s best product literature, ranging from atalogs, Installation and Operation Manuals (IOM s), lectronic Media, omputer ided Selection Program (PS) and more. ll of these can be found at www.greenheck.com ount on personal service and expertise from our national and international representative organization. To locate your nearest Greenheck representative, call () 9- or visit us at

Model Number ode SP - 0 FL Table of ontents Light Options: L - Fan/Light (Incandescent) ombination FL - Fan/Light (Fluorescent) ombination Nominal cfm at 0.0 inches static pressure Level of onstruction: - Premium unit; lowest sound, insulated housing - eluxe unit; low sound, low profile - Standard unit; lowest profile, inexpensive Model: SP - Silent Partner SP - abinet Silent Partner R SP-................ SP- Light........... SP- Performance.... SP-..............0 SP- Performance... SP-................ SP- Light........... SP- Performance.... SP-............. SP- Performance...9 SP-................ SP- Performance.... Sound ata..........9 ccessories...... - Specifications........9 Quick elivery and Quick uild Programs Order from hundreds of SP and SP configurations, accessories, and thousands of other products that can ship to your job site in less than hours. We have strategically located warehouses across the United States and Internationally to fill your request at a moments notice. Speed up your process even more by ordering your units at Q Online at www.greenheck.com/qd. For other sizes and configurations where rapid response time is required, our Quick uild (Q) Program manufactures and ships your custom products in one, three, five, or ten days..

PRMIUM ILING FN SP The SP- is a Premium eiling Fan. It is in the top of its class when it comes to meeting sound requirements. Profile as low as 0 / inches. Sound levels as low as 0. sones. ir volume as high as,0 cfm. UL Listed for above bathtub/shower with GFI branch protected circuit. SP- FTURS 9 0 Spring Loaded luminum ackdraft amper - liminates rattling or unwanted backdrafts. Outlet - oth square and round 0 outlets are field rotatable from horizontal to vertical discharge. Power ssembly - Removes quickly for maintenance or conversion from horizontal to vertical discharge. xternal lectrical ccess - liminates removing motor pack, saving installation time. lectrical Knockouts (horizontal or vertical) - liminates drilling holes. coustic Insulation - bsorbs sound. isconnect - Servicing is quick and safe. lectrical Junction ox - Large for easy wiring. ttractive esigner Grille - oncealed attachment screws securely fasten grille to housing for quiet, rattle free operation. Mounting rackets - Fully adjustable for multiple installation conditions. Housing - mbossed galvanized steel for rigidity. Motors - ll motors are compatible for use with speed controls and have thermal overload protection. oth domestic and international applications available. 0 cycle, 0v, and 0v options. (See page for availability) 0 cycle, v, 0v, 0v, 0v, and v options. (See PS for availability) Grille Options esigner - Standard Grille ecorative - Lighted and non-lighted luminum - White enamel finish Stainless steel - Polished stainless steel finish Round uct onnection Standard -Sizes 0, 0, and 90. Round uct dapter Optional - Sizes 0 through 0 xclusive lectrical Wiring Feature Greenheck SP- models are the only fans of this type with an electrical access cover located on the housing exterior. This feature permits external wiring without removing the power assembly, saving installation time and cost. Vertical ischarge Photo shows exhaust outlet duct installed in the optional vertical position. The power assembly must be rotated to match the duct adapter position. (See SP- IOM) ouble Wide Fans vailable for applications requiring 00 cfm or greater. ouble wide fans have two double width forward curved wheels, which are housed in separate scrolls, and driven by a single motor. 9

PRMIUM ILING FN SP Light Options Greenheck s fan/light combination includes a prismatic or frosted lens, and compact fluorescent or incandescent lamps. Our unique patent pending light box is manufactured with a reflective material to increase the light given off by either type of lamp. UL Listed for above bathtub/showers with GFI branch protected circuit. vailable on Sizes 0 - Prismatic Lens The prismatic lens design provides approximately % more light than a traditional frosted lens. The lens may be easily removed to replace light bulbs. (Patent Pending) ompact Fluorescent Lamps (FL) Quick start bulbs Reflective light box (Patent Pending) Produce 90% less heat Lower energy costs Two watt FL bulbs equals 00 watts of incandescent light (included) Frosted Lens The frosted lens option is a traditional design which lets approximately 0% of light through the lens. The lens may be easily removed to replace light bulbs. Incandescent Lamps immable Reflective light box (Patent Pending) Low first-cost light One bulb provides up to 00 watts of light (by others) major advantage of using FL's is to save money, as shown in the table to the right. This table assumes the light is on for hours per day and that the electric rate is 0 cents per kilowatt-hour. This study was based over a. year period. eiling Radiation amper Watt 00 Watt ompact Fluorescent Incandescent ost of Lamps $.00 $0.0 Lamp Life. days (. years ) days nnual nergy ost $.9 $.90 Lamps Replaced in. years 0 0 Total ost $0.0 $0. Savings Over Lamp Life $.9 $0.00 Source: U.S. epartment of nergy, ugust 00 Office of nergy fficiency and Renewable nergy National Fire Protection ssociation (NFP) Standard 90 requires openings in fire rated ceiling/floor assemblies be protected by appropriately rated ceiling radiation dampers. s a result, many local codes require fans installed in fire rated ceilings must also be protected by dampers which are insulated against both heat and flame. The Greenheck SP- ceiling radiation damper is UL lassified, rated at three to four hours fire resistance, and is available on all SP- fans and fan/light combinations. This design saves space by allowing the damper to mount directly beneath the fan. " x SP- Fan Hanging Vibration Isolation eiling Radiation amper Grille Fire Rated eiling *R is approximately / inch larger than housing dimension. (See SP- IOM)

LUX ILING FN SP The SP- is a eluxe eiling Fan compact enough for almost any application. If quiet is what you are after, this fan will accommodate your needs. Profile as low as / inches. Sound levels as low as. sones. ir volume as high as 9 cfm. UL Listed for above bathtub/shower with GFI branch protected circuit. SP- FTURS 9 0 luminum ackdraft amper - Prevents unwanted backdrafts. Round Standard Outlet ( or in.) - Versatile for quick, easy connections. Power ssembly - Removes quickly for maintenance. lectrical ccess (vertical) - liminates drilling holes. isconnect - Servicing is quick and safe. lectrical Junction ox - Large for easy wiring. ttractive esigner Grille - oncealed attachment screws securely fasten grille to housing for quiet, rattle free operation. Mounting rackets - Fully adjustable for multiple installation types. Housing - mbossed galvanized steel for rigidity and low profile for height restricted areas. Motors - ll motors are compatible for use with speed controls and have thermal overload protection. oth domestic and international applications available. 0 cycle, 0v, and 0v options. (See page for availability) 0 cycle, v, 0v, 0v, 0v, and v options. (See PS for availability) 9 Grille Options esigner - Standard Grille ecorative - Lighted and non-lighted luminum - White enamel finish Stainless steel - Polished stainless steel finish Round uct onnection in. - 0, 0, and 0 in. - 90, 0, 0, and 00 0 ontractor Paks Save installation time and labor by installing the housing first, then installing the internal components after the sheetrocking, plastering, and finishing is done. Housings are packaged in one box, power assembly and grille are packaged in another box. omponents are shipped to coincide with the phase of your project.

LUX ILING FN SP Light Options Greenheck s new fan/light combination includes a prismatic or frosted lens, and compact fluorescent or incandescent lamps. Our unique patent pending light box is manufactured with a reflective material to increase the light given off by either lamp. UL Listed for above bathtub/showers with GFI branch protected circuit. vailable on Sizes 0-0 Prismatic Lens The prismatic lens design provides approximately % more light than a traditional frosted lens. The lens may be easily removed to replace light bulbs. (Patent Pending) ompact Fluorescent Lamps (FL) Quick start bulbs Reflective light box (Patent Pending) Produce 90% less heat Lower energy costs Two watt FL bulbs equals 00 watts of incandescent light (included) Frosted Lens Incandescent Lamps The frosted lens option is a traditional design which lets approximately 0% of light through the lens. The lens may be easily removed to replace light bulbs. immable Reflective light box (Patent Pending) Low first-cost light One bulb provides up to 00 watts of light (by others) major advantage of using FL's is to save money, as shown in the table to the right. This table assumes the light is on for hours per day and that the electric rate is 0 cents per kilowatt-hour. This study was based over a. year period. eiling Radiation amper Watt 00 Watt ompact Fluorescent Incandescent ost of Lamps $.00 $0.0 Lamp Life. days (. years ) days nnual nergy ost $.9 $.90 Lamps Replaced in. years 0 0 Total ost $0.0 $0. Savings Over Lamp Life $.9 $0.00 Source: U.S. epartment of nergy, ugust 00 Office of nergy fficiency and Renewable nergy National Fire Protection ssociation (NFP) Standard 90 requires openings in fire rated ceiling/floor assemblies be protected by appropriately rated ceiling radiation dampers. s a result, many local codes require fans installed in fire rated ceilings must also be protected by dampers which are insulated against both heat and flame. The Greenheck SP- ceiling radiation damper is UL lassified, rated at three to four hours fire resistance, and is available on all SP- fans and fan/light combinations. This design saves space by allowing the damper to mount directly beneath the fan. " x SP- Fan Hanging Vibration Isolation eiling Radiation amper Grille Fire Rated eiling *R is approximately / inch larger than housing dimension. (See SP- IOM)

STNR ILING FN SP The SP- is our economy ceiling fan designed for light commercial applications. Profile as low as / inches. Sound levels as low as.9 sones. ir volume as high as cfm. UL Listed for above bathtub/shower with GFI branch protected circuit. SP- FTURS Plastic ackdraft amper - Prevents unwanted backdrafts. Round Outlet - inch diameter allows quick easy connections. Power ssembly - Removes quickly for maintenance. isconnect - Servicing is quick and safe. Polymeric Grille - Quickly snaps into place. Mounting rackets - djustable for several installation types. Housing - Galvanized steel for rigidity and low profile for height restricted areas. Motors - ompatible for use with speed controls and has thermal overload protection. 0 cycle, v

Things to know, when sound is critical SOUN T The sound data shown in this catalog has been presented to aid the system designer in selecting a fan which will meet the desired sound criteria. Sone levels have been included on the performance pages to provide a means of quickly evaluating the relative loudness of a fan selection. What is a sone? Sones are an internationally recognized unit of loudness. In practical terms, the loudness of one sone is equivalent to the sound of a quiet refrigerator measured from five feet away in an acoustically average room. sone is a single number rating, which indicates the inlet noise derived from the eight audible octave bands. Sones are a linear measurement of sound level. For example, a sound level of 0 sones is twice as loud as sones. What is the difference in a M Sone vs. HVI Sones? In general, the M (ir Movement and ontrol ssociation) sone value is focused on commercial markets, whereas the HVI (Home Ventilating Institute) sone value is focused on residential markets. oth calculate their sone data from the same raw test data (eight octave bands), however an M sone applies a hemispherical correction factor to the sound power and rounds to the nearest 0., whereas HVI applies a spherical correction factor to the sound power and rounds to the nearest 0. under. sones and to the nearest 0.,. sones and greater. There are no conversions from one sone to the other, each must be calculated. In every instance the same fan will have a lower HVI calculated sone rating than an M calculated sone rating. an radiated noise increase the sound levels? Radiated noise from fan housings can cause unacceptable sound levels, on any brand of fan. The size of these fans allows them to be placed in areas where this noise will be transmitted to the conditioned space through walls or ceilings. Where possible, cabinet fans should be located in remote parts of the ventilation system. When should a SP or SP fan be used? Model SP and SP fans are designed for the lowest possible sound levels. Forward curved wheels, insulated housings, and vibration isolators between the motor and housing contribute to quiet, efficient operation. pplied and installed as recommended, SP and SP sound levels will fall well within the ranges shown in the chart above. For applications where sound levels are critical, a remote mounted SP with ductboard is recommended. Placement of SP/SP fans should take into account the desired sound level at the location of the listener. Their compact size allows the system designer greater flexibility in locating these fans for lowest sound levels. In critical sound areas, insulated ductwork, flexible duct connections, or placing the fan in a remote section of the ductwork (away from the critical area) offers the best means of meeting desired sound levels. When room sound levels are critical, such as in executive offices, conference rooms, hospital operating rooms, and school study areas, a SP fan is the best choice. Shown here is a comparison of SP and SP fans of the same size, with equal performance in typical installations. The SP shows lower sone values. Fiberglass ductboard SUGGST LIMITS FOR ROOM LOUNSS Sones.- - Private homes (rural and suburban).- - onference rooms - - Hotel rooms, libraries, movie theatres, executive offices.- - Schools and classrooms, hospital wards and operating rooms -9-0 ourt rooms, museums, apartment houses, private homes (urban) - - Restaurants, lobbies, general open offices, banks - - orridors and halls, cocktail lounges, washrooms and toilets - - Hotel kitchens and laundries, supermarkets Reprinted from M Publication 0 (pplication of Sone Ratings for Non ucted ir Moving evices with Room-Sone-d correlations). with the written permission from the M International Inc. 0 West University rive, rlington Heights, IL 000-9. NOT: Values above are for room loudness and are not sound ratings. Room loudness is the resulting level in a conditioned space after the acoustical qualities of the room have been accounted for. Remote mounted Model SP with vibration isolators and insulated ductwork provides quietest installation. Model FM WG FRPM Sones SP-0 0 / 000. SP-0 / 000.* *Sone value with insulated inlet duct. Model SP mounted directly overhead may be too loud for sound critical applications. 9

PRMIUM INLIN FN SP The SP- is a Premium Inline Fan. It outperforms the competition and is preferred by specifying engineers. Profile as low as 0 / inches. Sound levels as low as 0. sones. ir volume as high as, cfm. UL/cUL Listed. SP- FTURS 9 0 0 Spring Loaded luminum ackdraft amper - liminates rattling or unwanted backdrafts. Outlet - oth square and round outlets are field rotatable from horizontal to vertical discharge. Power ssembly - Removes quickly for maintenance or conversion from horizontal to vertical discharge. xternal lectrical ccess - liminates removing motor pack, saving installation time. lectrical Knockouts (horizontal or vertical) - liminates drilling holes. coustic Insulation - bsorbs sound. isconnect - Servicing is quick and safe. lectrical Junction ox - Large for easy wiring. ccess Panel - Gain easy access to internal components once installed. Mounting rackets - Fully adjustable for multiple installation conditions. Housing - mbossed galvanized steel for rigidity. Motors - ll motors are compatible for use with speed controls and have thermal overload protection. oth domestic and international applications available (not shown). 0 cycle, 0v, and 0v options. (See page for availability) 0 cycle, v, 0v, 0v, 0v, and v options. (See PS for availability) 0 xclusive lectrical Wiring W Feature Greenheck SP- models are the only fans of this type with an electrical access cover located on the housing exterior. This feature permits external wiring without removing the power assembly, saving installation time and cost. Vertical ischarge Photo shows exhaust outlet duct installed in the optional vertical position. The power assembly must be rotated to match the duct adapter position. (See SP- IOM) ouble Wide W Fans vailable for applications requiring 00 cfm or greater. ouble wide fans have two double width forward curved wheels, which are housed in separate scrolls, and driven by a single motor. 9

LUX INLIN FN SP The SP- is a compact eluxe Inline Fan. It is designed to fit in small remote quarters. Profiles as low as / inches. Sound levels as low as.0 sones. ir volume as high as cfm. UL/cUL Listed. SP- FTURS luminum ackdraft amper - Prevents unwanted backdrafts. Round Standard Outlet ( or in.) - Versatile for quick, easy connections. Power ssembly - Removes quickly for maintenance. 0 9 lectrical ccess (vertical) - liminates drilling holes. isconnect - Servicing is quick and safe. lectrical Junction ox - Large for easy wiring. ccess Panel - Gain easy access to internal components once installed. Mounting rackets - Fully adjustable for multiple installation types. 9 Housing - mbossed galvanized steel for rigidity and low profile for height restricted areas. 0 Motors - ll motors are compatible for use with speed controls and have thermal overload protection. oth domestic and international applications available. 0 cycle, 0v and 0v options. (See page 9 availability) 0 cycle, v, 0v, 0v, 0v, and v options. (See PS for availability)

ccessories Speed ontrols Speed controls may be used on Model SP and SP fans for manual adjustment of the fan s performance (for final system balancing) or to control the fan s output in confined spaces, such as conference or meeting rooms. The fan can be adjusted to 0% of design airflow with a speed control. This reduction in airflow and fan speed is also accompanied by a reduction in noise level. Solid state speed controls are available for a range of applications up to amps. Speed controls can be used to operate more than one fan if the combined total amperage of the fans does not exceed the control rating. Model WSS - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for - V, mp UL Listed Require a x handy box Model W0 - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for 0-0V, mp UL Listed Requires x handy box Model W - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for V, mp UL Listed Requires x handy box Model WSS - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for 0-0V, mp UL Listed Requires x handy box Model 0WSS - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for - V, 0 mp UL Listed Requires x handy box Model WSS - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for - V, mp UL Listed Requires x handy box Switches H N LO 0 V FULL VOLTG LK XTRNL JUMPR SP ONTROL Switches may be used on Models SP and SP fans to enable manual control of your fan or fan/light combination. There are several options to fit your application. NM - Single pole rocker switch assembly. Rated for, V, mp, / Hp UL Listed Model MS-- Single pole rocker switch assembly with cover and pilot light. Rated for, V, mp, / Hp UL Listed NM - Two pole rocker switch assembly. Rated for, 0/0/0/V, 0 mp, Hp UL Listed Requires a x handy box. Time elay Switch R WHIT VRIL VOLTG SWITH FULL VOLTG otted line indicates for use with 0W switch only. Time delay switches save energy by automatically turning off equipment. They may be used with Models SP and SP fans and fan/light combinations, for extended operating time of fan. Time delay switches act in the same manner as a standard switch, however, there is a delay of to 0 minutes after the it has been turned off. FN UX VI LO Model GT - Single switch controls both fan and light. vailable shipped loose. VOLT 0 YL (HOT) LK LU (00 Watt Max) LIGHT Silent Operation UL Listed Rated for V Requires x handy box (NUTRL) WHIT R (. mps Max) FN MOTOR

ccessories Motion etectors Motion detectors may be used with Models SP and SP fans, or fan and light combinations. Motion detectors use a passive infrared motion detector that will automatically turn on the fan when a change in temperature is sensed. They have a viewing area of 0 degrees, however they must be placed in the line-of-sight. They also have an adjustable time delay shutoff setting of to 0 minutes. Grille Motion etectors are available on models up thrugh size SP-90 and SP-00. Rated for V UL Listed Model MW For use on fan or lights. vailable shipped loose. Rated for V UL Listed Requires x handy box Transformers Model T-.0 - UL Listed Rated for 0/ to, mps Model T-. - UL Listed Rated for 0/ to,. mps Model T-. - UL Listed Rated for 0/ to,. mps Model T-. - UL Listed Rated for 0/ to,. mps lack Green Gnd. Red Load (. mps Max.) Wall Mount Transformers are available for applications requiring voltage reduction. Selection is based on motor amperage. ll transformers are shipped loose. LK H H H V TO V TRNS. 0 V X R LK Hot Neutral X R LK Motion Sensor Fan Motor and/or Light Grille Mount SWITH OX SWITH lack White Red lack Green White Hot Neutral Ground V SUPPLY V MOTOR eiling Radiation amper Filters The Greenheck SP- and SP- ceiling radiation dampers are UL lassified, rated at three to four hours fire resistance, and is available on all SP- and SP- fans and fan/light combinations. This design saves space by allowing the damper to mount directly beneath the fan. Fans used in most applications, even where air is not excessively dirty, will collect airborne dirt on wheels and motors over time. ccumulations of dirt on the fan wheel will sharply reduce performance and cause imbalance. irt buildup on the motor can cause it to overheat. ll of these conditions will shorten the life of the fan. To help reduce this accumulation, washable aluminum mesh filters are available to trap FILTR LOSS HRT dirt before it enters the fan. These filters should be regularly cleaned to maintain. performance. Fig. (Filter Loss hart) shows the effect the filter will have on. performance. To determine the added resistance, divide the desired cfm by the filter area (ft.0 ). This will give FPM. Use this with the filter loss chart to get the added resistance. In addition to reducing dirt accumulations on the motor and. wheel, filters also reduce sound levels.. IMNSIONL T. SP Model Filter Model Filter esigner lum. rea Grille Grille (ft) SP-0-90 F-00 F-0.0 SP-0-00, 00-90 F-00 F-0. SP-0-0 SP-0-0 N F-0.9 SP-900-0 N F-0.9 Mesh Filter SP Grille SP Model R Length Width Height 0-90 0.. 0-00 00-90 0.. 0-0 0-0 0.9. - 00 00.9. 900-0 0.9. *dd an L to all R models if fan & light combo is used. Resistance in w.c...0.0.0.0.0.00 0 9 Velocity FPM x 00 Fig.

Wall ischarge ccessories G F MOL W (Round onnection) Hooded Wall ap luminum construction - aluminum finish For outside wall applications uilt in birdscreen (not available on W-) and damper For use Model with sizes W- 0, 0-0 / / W- 90-00 0-90 / W- 00-0 /. MOL W (Square/Rectangular onnections) Hooded Wall ap Steel construction with black enamel finish For outside wall applications uilt in birdscreen and damper For use Model with sizes F G W-0x 0-90 / / / 0 / / / W-x 00-0 0 / 0 / / / / / W-x 00-0 0 / 0 / / / / / MOL WL Wall Louvered ischarge nodized aluminum grille uilt in damper Not recommended for exterior applications exposed to severe weather conditions. n external wall louver is recommended for such applications. For use Model with sizes WL-0x 0-90 / 0 / / WL-x 90-0 9 / 9 MOL R Round uct onnector Replaces the standard square discharge ductconnector and damper. Uses existing mounting holes Galvanized steel construction R does not include a damper MOL TR X Transition uct Reducer Reduces duct from to inches. Galvanized steel construction For use with sizes Model 0-00 TR x 0-90 0-90* * Used in conjunction with R-. ia. For use with sizes Model ia. R- 0-90 R- 00-0 in. dia.. in. in. dia FM x 00 0 0 MOL V rick Vent esigned for installation in masonry walls nodized aluminum construction uilt in aluminum mesh insect screen 0 9 For use Model with sizes V0 0-90 / / V 90-0 / V 00-00 / / SSORY PRSSUR ROPS The chart below can be used with all of the discharge accessories shown on these two pages. Specific pressure drop values for these accessories must be included in total system calculations for proper fan selection..0.0.0.0.0.0.0.0.09.0..... Pressure rop in Inches of Water Gauge bove accessories tested with feet of inlet duct WL-x RJ-0x0 V- W-x V- W-x W- W-0x W- RJ-x9 L-0x WL-0x V-0 RF- R-

oof ischarge ccessories / / 9 / 0 MOL RJ Pitched Roof ap Steel construction with black enamel finish Integral flashing flange uilt in birdscreen and damper Model For use with sizes Throat RJ- 0, 0-0 9 / / / / in. ia. RJ-x9 90-00 0-90 / / / 0 / / x9 RJ-0x0 0-00 / / / / 9 / 0x0 UR P Flat Roof aps / MOL L - 0x lbow ischarge with Grille esigned for installation under roof eaves Painted steel grille uilt in damper For SP/SP sizes 0-90 / FLSHING FLNG ia. ia. / ia. / in. ia. MOL R- Weathertight aluminum construction Integral birdscreen uilt in curb cap Requires roof curb MOL GRS ll aluminum exterior construction Galvanized steel internal supports Integral birdscreen uilt in curb cap Requires roof curb MOL RF- Weathertight aluminum construction Integral birdscreen uilt in flashing flange MOL GRSF ll aluminum exterior construction Galvanized steel internal supports Integral birdscreen uilt in flashing flange Model For use with sizes Throat ia. R- 0-90 0 / GRS-0 0-0 9 0 / / 0 / GRS- 0-00 / / / / GRS- 0-0 / / / / GRS-0 00 0 9 / / 0 / Model For use with sizes Throat ia. RF- 0-90 0 / GRSF-0 0-0 0 / / 0 / GRSF- 0-00 / / / / GRSF- 0-0 0 / / / / GRSF-0 00 9 / / 0 / HNGING VIRTION ISOLTORS Vibration isolator kits are available for suspended installations. Kits include all hardware necessary to mount one unit, with the exception of 0- threaded rod to be supplied by others. Fan mounting brackets include prepunched mounting holes for ease of installation. 0- hanging support rod by others Unit Size 0-00 / / 0-90 / / 00-90 / / 0, 0 0, 0 9 / 9 / 00 / / 900-00 0-0 9 / / 0, 0 9 / / 00 9 / /

PRMIUM ILING FN SP IMNSIONL T Model Outlet connection width is inch - Mounting bracket width is / inch For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. Std. ecorative Unit Grille Grille WT. 0, 0, 90 / 0 / / I. / x / / sq. 0,, 90 / 0 / 0 / / x / / sq. 00, 0, 90, 90 / / / x / / sq. 0, 0 / / 9 / x / - 00 / / / 9 / / x / - 0, 0 / / 0 9 / x / - 900, 00, 0, 0 / / / / x / - PRFORMN T HVI FM/Static Pressure in inches of WG Model RPM mps Watts Sones 0.000 0.00 0. 0.0 0. 0.00 0. 0.0.000,, FM 0 SP-0 00 0. 0. Sones 0..0..,, FM 0 SP-0 0 0. 0 0. Sones....,, FM 99 SP-90 900 0. 9.0 Sones.....9,,,, FM 9 0 0 SP-0 90 0. 9 0. Sones....,,, FM 0 SP- 00 0.. Sones....9,,, FM 9 9 SP-90 00.0.0 Sones...9.., FM 0 9 0 SP-00 900 0..0 Sones.0...0...., FM 0 9 SP-0 000 0..0 Sones.9.0.0....9.,, FM 9 0 SP-90 00 0.. Sones.....9...,, FM 0 9 9 0 9 SP-90 0.. Sones.....0... FM 0 0 SP-0 000..0 Sones....., FM 0 9 9 SP-0 00.0. Sones.0..... FM 9 00 9 9 0 9 SP-00 00.0 0. Sones......... FM 0 0 SP-0 00.0.0 Sones....0..., FM 0 SP-0 00.0. Sones 0. 0. 0. 9.9 9. 9. 9. 9. FM 9 90 9 0 SP-900 90.00. Sones......, FM 09 0 9 9 SP-00 09.0 0.0 Sones..0.9.... FM 0 0 SP-0 0.0 9. Sones........, FM 0 0 9 0 9 SP-0 0.0 0.0 Sones....0.9...9 HVI sones at 0. wg vailable with light Performance shown is for Model SP exhaust for installation type : Free inlet, ucted outlet. Performance ratings include the effects of an inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per M Standard 0. Values are for installation type : free inlet fan sone levels. vailable with R - eiling Radiation amper vailable with 0 Hz motors (See PS for performance) UL Listed for use above tubs. vailable with volt motor.

LUX ILING FN IMNSIONL T SP Model * esigner ecorative Unit Grille Grille WT. 0, 0, & 0 / / / / / x / / sq. 9 90, 0, 0, 00 / / / / / x / / sq. 0 * dd. inches to dimension for incandescent light Mounting bracket width is / inch For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. PRFORMN T Model RPM MPS HVI FM/Static Pressure in inches of WG Watts Sones 0.000 0.00 0. 0.0 0. 0.00 0. 0.0.000 SP-0 0.0. FM 0 9 Sones..9.9.. SP-0 0.. FM 0 9 9 Sones..9.9... SP-0 900 0.0. FM 0 0 Sones.9.9.0..... SP-90 00 0. 0.0 FM 0 9 9 0 Sones.9...0...9 SP-0 90. 0. FM 0 9 9 9 9 0 Sones.0........ SP-0 00.0 9. FM 0 9 9 Sones.0......0.. SP-00 00.0.0 FM 9 9 9 9 Sones.......0..,,,,,,,,,,,,,,,,,,,, HVI sones at 0. wg vailable with light vailable with R - eiling Radiation amper vailable with 0 Hz motors (See PS for performance) UL Listed for use above tubs. vailable with volt motor. Performance shown is for Model SP exhaust for installation type : Free inlet, ucted outlet. Performance ratings include the effects of an inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per M Standard 0. Values are for installation type : free inlet fan sone levels. R STNR ILING FN SP IMNSIONL T Model F Grille Weight 0 / / / / / 9 / x 9 For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. F PRFORMN T FM/static Pressure in inches of WG Model RPM MPS Watts 0.00 0.00 0. 0.0 0. 0.00 0. FM 9 9 SP-0 0 0.0 Sones.9...9... Performance shown is for Model SP exhaust for installation type : Free inlet, ucted outlet. Performance ratings include the effects of an inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per M Standard 0. Values are for installation type : free inlet fan sone levels.

PRMIUM INLIN FN SP IMNSIONL T Model F G WT. 0,, 90 / 0 / 0 / 9 / 00,0, 90, 90 / / / 0 0, 0 / / / / 00 / / / 9 / / 0 / 0, 0 / / 0 / / 900, 00, 0, 0 / / / / / / 9 0, 0 / / / 00 / / / 0 / / F F Inlet G Inlet and outlet connections widths are inch - Mounting bracket width is / inch For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. G PRFORMN T Model RPM MPS Watts, SP-0 90 0. SP- 00 0., SP-90 00.0 00 SP-00 900 0. SP-0 000 0.9 SP-90 00 0. 0 SP-90 0. SP-0 000. 9 SP-0 00. SP-00 00.0 0 SP-0 00.0 SP-0 00. 0 SP-900 90. SP-00 09. SP-0 0.0 SP-0 0. 0 SP-0 0.0 0 SP-0 00.0 SP-00 00.0 0 Units available with 0 Hz motors (See PS for performance) FM/Static Pressure in inches of WG 0.000 0.00 0. 0.0 0. 0.00 0. 0.0.000 FM 0 0 Sones..... FM 9 Sones..... FM 0 9 0 9 Sones..0...9.0 FM 0 0 09 0 Sones 0. 0. 0....9.. FM 0 Sones........0 FM 99 9 9 0 Sones......0.. FM 00 9 9 09 Sones........ FM 0 Sones...... FM 0 0 Sones..9.... FM 9 0 Sones........0.9 FM 9 Sones....... FM 0 0 Sones......... FM 90 0 Sones....0.0. FM 0 09 0 9 Sones...9..0.0. FM 9 9 9 Sones......... FM 0 0 Sones......... FM 9 9 0 Sones.9....... FM 9 0 900 0 Sones.......0. FM 0 0 09 0 Sones....0..... vailable with volt motor. Performance shown is for Model SP inline for installation type : Insulated ucted inlet, ucted outlet. Performance ratings include the effects of a backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) from the test inlet duct in a hemispherical free field calculated per M Standard 0. Values are for installation type : ucted inlet fan sone levels. Ratings do not include the effects of duct end correction.

LUX INLIN FN SP IMNSIONL T Model F G WT. 0, 0, 00 / / / / 0 / / 0 / Outlet connection width is inch - Mounting bracket width is / inch For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. PRFORMN T Inlet FxG dia., Model RPM MPS Watts SP-0 90. 0, SP-0 00.0 9, SP-00 00.0 Units available with 0 Hz motors (See PS for performance) Performance shown is for Model SP inline for installation type : Insulated ucted inlet, ucted outlet. Performance ratings include the effects of a backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) from the test inlet duct in a hemispherical free field calculated per M Standard 0. Values are for installation type : ucted inlet fan sone levels. Ratings do not include the effects of duct end correction. MOL SP-0 eiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of steel. The plastic duct collar shall be a tapered sleeve for ease of connection to and in. round ductwork and shall include a backdraft damper. The grille shall be constructed of non-yellowing high impact polystyrene and attached to the housing with torsion springs. The wheels shall be constructed of high strength polymer. The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. ll fans shall bear the M ertified Ratings Seal for sound and air performance. Model SP-0 shall be UL listed. Fans shall be Model SP-0 as supplied by Greenheck, Schofield, Wisconsin. MOLS SP-0, 0, 0, 90, 0, 0, and 00 eiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of steel. The steel duct collar shall be in. in diameter on the 0, 0, and 0 and in. in diameter on the 90, 0, and 00 to accept in. and in. round ductwork and shall include a backdraft damper. The designer grille shall be constructed of non-yellowing high impact polystyrene and attached to the housing with hidden attachment screws. The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. The motor shall mounted on vibration isolators. The fan wheel shall be of the forward curved centrifugal type, constructed of calcium carbonate filled polypropylene and dynamically balanced. ll fans shall bear the M ertified Ratings Seal for sound and air performance and shall be UL/cUL Listed. eiling or wall mount fans shall be Model SP-0, 0, 0, 90, 0, 0 or 00 as manufactured by Greenheck, Schofield, Wisconsin. MOLS SP-0 thru 0 eiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of heavy gauge galvanized steel. The housing interior shall be lined with / in. acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper on all SP- sizes and shall be spring loaded on size SP-0 and larger. Outlet shall be adaptable for horizontal or vertical discharge. The designer grille for sizes SP-0 through SP-90 shall be constructed of high impact polystyrene and for sizes SP-0 through SP-0, the grille shall be constructed of aluminum. Grilles shall be non-yellowing. FM/Static Pressure in inches of WG 0.000 0.00 0. 0.0 0. 0.00 0. 0.0 FM 0 00 99 9 9 9 9 Sones.0.0...... FM 9 9 Sones....9....9 FM 0 9 Sones....0.... vailable with volt motor. TYPIL SPIFITIONS The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. The motor shall be mounted on vibration isolators. The fan wheel(s) shall be of the forward curved centrifugal type and dynamically balanced. ll fans shall bear the M ertified Ratings Seal for sound and air performance and shall be UL/cUL Listed. eiling or wall mount fans shall be Model SP as manufactured by Greenheck, Schofield, Wisconsin. MOLS SP-0, 0, and 00 uct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of steel. The steel duct collar shall be in. in diameter to accept in. round ductwork and shall include a backdraft damper. The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. The motor shall mounted on vibration isolators. The fan Wheel shall be of the forward curved centrifugal type, constructed of calcium carbonate filled polypropylene and dynamically balanced. ll fans shall bear the M ertified Ratings Seal for sound and air performance and shall be UL/cUL Listed. eiling or wall mount fans shall be Model SP-0, 0 or 00 as manufactured by Greenheck, Schofield, Wisconsin. MOLS SP-0 thru 00 uct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of heavy gauge galvanized steel. The housing interior shall be lined with / in. acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper and shall be adaptable for horizontal or vertical discharge. The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. The motor shall be mounted on vibration isolators. The fan wheel(s) shall be of the forward curved centrifugal type and dynamically balanced. ll fans shall bear the M ertified Ratings Seal for sound and air performance and shall be UL/cUL Listed. eiling or wall mount fans shall be Model SP as manufactured by Greenheck, Schofield, Wisconsin. 9

eiling Fan Solutions... eiling Fans eiling Fans w/ Light eiling Fans w/ R eiling Fans w/ Light & R SP-0 SP-0 SP-90 SP- SP-0 SP-0 SP-90 SP-90 SP-0 SP-90 SP-00 SP-0 SP/SP LIMIT WRRNTY Greenheck Fan orporation warrants its SP/SP products to be free of any defect in material or workmanship for a period of three () years from the date of purchase. In the event of such a defect during the warranty period, Greenheck Fan orporation agrees, at its option, to either repair or replace the defective product free of charge. This warranty runs to the original purchaser of such SP/SP products for a period of three () years from the date of purchase. ny product repaired or replaced under this warranty will, itself, be warranted only for the remainder of the warranty period of the original product being repaired or replaced. ll light bulbs are excluded under this limited warranty. Greenheck Fan orporation is not responsible for any removal, installation, or transportation cost. For full SP/SP warranty information visit www.greenheck.com. ue to continuing research, Greenheck reserves the right to change specifications without notice. R Number one in air movement and control. entrifugal and Vane xial Fans Fans and Ventilators nergy Recovery Ventilators & Make-Up ir Units Kitchen Ventilation Systems ampers and Louvers Visit the Greenheck website for the most current information available www.greenheck.com Greenheck P.O. ox 0 Schofield, WI -00 Phone ()9- Fax ()-99 www.greenheck.com opyright 00 Greenheck Fan orp. SP SP SP Rev November 00