Kair Single Room Heat Recovery Ventilator

Similar documents
Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Centrif Duo & Centrif Duo Plus

Lo-Carbon SELV Tempra

Lo-Carbon Quadra SELV

HR200WK Through the wall Heat Recovery Ventilator

Lo-Carbon T-series Window & Roof Models

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon Quadra Centrifugal Fan

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Compact Cyclonic Bagless Upright Vacuum Cleaner

Watch the heatsava video

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

BLOW DRY & GO HAIR KIT

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Double Door - Dual Zone Wine Cooler

CoCo LoCo BLOW & GO NUTS DRYER. LSHD24 Instruction Manual

MeacoDry ABC Range Dehumidifiers

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

Power 4. User Guide. HC85-P4-ZA hoover.za.com

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

Sentinel Kinetic MVHR RANGE

Wiring the fan correctly...

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

Installation and Maintenance

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

HOTLINE:

Earn BISSELL Rewards! Register your

100 FLUEBOOST

Installation and Operating Instructions MODEL: MSE46W

Installation instructions. and User guide. Freestanding canopy NZ AU. HF60CSW2 & HF60CSX2 models

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Simply Silent Contour 4 (100mm) Axial Extraction Fan

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

U88-T2-B. User Guide. Bagless Upright. Get Cleaning... vax.co.uk. U88-T2 series. What s your Vax model number? (Located on the flap of the packaging)

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Imperial Electric Fires

Thank you for choosing EnviroVent

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

November This product has been reconfigured Please read these instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Installation and Maintenance

Operating Instructions. for your Ford & Doonan Ducted System

Installation instructions. and User guide. Slideout rangehood NZ AU. HS60CSRX2, HS60CSRW2, HS90CSX2, HS60CSW2, HS60CSX2, HS60CIW2, HS60CIX2 models

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

User Manual. 60 cm Knob control 4 zone ceramic cooktop

Cordless Bagless Upright Vacuum Cleaner

CORDLESS. SlimVac CORDLESS SLIM VAC WITH DETACHABLE HANDHELD LET S GET STARTED. TBTTV1B1 TBTTV1P1 TBTTV1P2 TBTTV1P3 TBTTV1T1 TBTTV1R1 VRS703

Designed in the UK. Rapide Ultimate. User Guide Vax Rapide Ultimate

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Air Cleaning System USE & CARE INSTRUCTIONS. Refurbished

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

ECOLEC PANEL HEATERS GENERAL NOTES.

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

EVG Extractors. Manual for Installation, Use and Maintenance

OIL FILLED RADIATOR Instruction manual

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

Wiring the fan correctly...

GUH52SD 52 cm GUH75 75 cm Canopy Hood

V. (Versus ) Bare Floor Vacuum

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

Lucci Designer Hi Flow Exhaust Fan

Installation and Operation Manual For Hunter Ceiling Fans

Bagless upright vacuum

HYDROMIST LITE CARPET CLEANER OPERATOR MANUAL

360º Surface Mount Ceiling PIR Light Controller

Maintenance Tips for Tenants

Meaco Platinum Range Instruction Manual

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Inverter Split-type Room Air Conditioner

Autofill counter top water boiler

Imperial Electric Fires

General Care and Safety Guide

Powerdri. UK Manual Accessories Warranty Registration. Professional Dehumidifier

DynamoPower MORE REACH MORE CAPACITY LET S GET STARTED. U84-DY-Pe U84-DY-Re U84-DY-Te

INSTALLER AND OWNER GUIDE

CDC266 Reverse Action

Get Cleaning... What s your Vax s model number? User Guide. Multifunction SpinScrub. vax.com.au. Vax Careline: AU: NZ:

18W Round LED Wall/Ceiling Light with Microwave Sensor

WHHR Midi & Midi Lite

CORDLESS. SlimVac. Fur&Fluff CORDLESS SLIM VAC WITH DETACHABLE HANDHELD LET S GET STARTED. TBTTV1F1

Multifunctional Food Processor User guide

Transcription:

Kair Single Room Heat Recovery Ventilator Model: KHRV150/12RH - Pullcord & Humidistat Fault Diagnosis and F.A.Q This is a step-by-step guide to resolving any issues your unit may have before getting in contact with your installation company. Follow the guide from start to finish unless otherwise instructed. Contents Content 2-4 Fault Diagnosis 2 Does the unit have power? 3 Does the unit manually boost? 4 Does the unit boost based on relative humidity? Is my light sensor set up correctly? 5-11 Frequently asked questions 5 How do I clean the filters in my unit? 5 & 6 Cleaning the rear filters 7 Tell me more about the inside of my transformer 8 & 9 I ve snapped my thumb wheel off my unit 10 & 11 Other frequently asked questions 12 Kair registration and warranty What am I? www.kair.co.uk

Does the unit have power? 1) ON = Main power. 2) ON = Manual boost override. OFF = Automatic humidity control. 3) Pullcord for manual boost control. 4) Turn anticlockwise towards 20 to increase sensitivity (Fan on boost for longer). Turn clockwise towards 90 to decrease sensitivity (Fan on boost for shorter time). 1 Assuming the unit has been correctly installed, your transformer should have a red power on light, depending on the model. If the light is on please go to page 3; Does the unit manually boost? If the light is off, please continue reading. The following checks should only be carried out by a suitably competent electrician and require the removal of the transformer housing cover by use of a tamperproof driver / bit. 2 If no light is on we firstly need to check that the fused spur is on and that its fuse is still in working order. Isolate the mains supply before opening the fuse spur. The fuse can be accessed by lifting the blanking plate with a flat headed screw driver. If the fuse spur is on and the fuse is OK your problem may well be with the quick-blow fuse in the transformer. 3 To the top left of the circuit board you will see two fuse positions, one labelled fast and one labelled slow. The reason for this is to allow adjustment for long cable runs. Make a note of which position your fuse is in before replacing and make sure your new fuse goes back in the same place. These units use a 5A quick-blow fuse. If both these checks are OK, the problem lies within either the wiring or connection from the fused spur to the transformer. 2

Does the unit manually boost? 1 Assuming the unit has been correctly installed, your transformer should have a red or green power on light, depending on the model. To indicate the unit is in trickle mode, the transformer should have its manual boost on light off. If both lights are on, pull the pull cord so that the manual boost on light turns off. 2 Place your hand towards the front fascia of the ventilator grille. A trickle air flow should be felt similar to a small breeze. This is demonstrated in the image to the right with ribbons. To check if the unit goes into manual boost pull the pull cord on the transformer. An extra light called manual boost on should light up. This informs you that the transformer and unit is in boost mode. If the manual boost light does not come on contact the installation company. 3 After pulling the pull cord both lights should come on and you should be able to hear an increased volume output from the unit. 4 Place your hand on the front fascia of the ventilator grille. You should be able to feel an increased airflow through the front fascia grille of the ventilator. This is demonstrated in the image to the right with ribbons. NOTE: The light sensor will not affect the manual boosting If no increased airflow is felt, contact the installation company. 3

Does the unit boost based on relative humidity? 1 Assuming the unit has been correctly installed, your transformer should have a red or green power on light, depending on the model. To indicate the unit is in trickle mode the transformer should have its manual boost on light off. 2 Adjust the humidistat wheel on the underside of the transformer so that it reads at its most sensitive and lowest setting i.e. 1 or 20 (dependant on dial). The unit should at some point on the way down to 20 (or 1) go into the boost mode. 3 You should be able to hear and feel an increased airflow through the front fascia grille of the ventilator. This is demonstrated in the image to the right with ribbons. The unit should be in this boost mode with the manual boost on light off. NOTE: The light sensor will have an effect. If the unit does not go into boost but did with the pull cord then the light sensor is in operation. To adjust the light sensor please see below. The unit should be set at 50% as standard for ideal humidity levels Is my light sensor set up correctly? To adjust the light sensor the unit must be disconnected from its power supply as we will be opening the transformer. We will need a tamperproof driver or bit. Unscrew the three retaining screws and remove the transformer housing. The light sensor is located at the bottom right of the transformer s circuit board. This can be adjusted to meet your requirements. NOTE: The sensor is factory set in the OFF position as this is preferred for most installations. This means the automatic boost feature will operate if the humidity rises during the hours of darkness. - Clockwise allows boost to operate during darkness - Anti-clockwise prevents boost operating during darkness A simple test for the correct setting is to trigger the boost feature via the humidity sensor in a darkened room. When switching the light on or off, the boost speed should cut in and out accordingly. Fine-tuning may be required for precise operation. You may find that if light levels change in the room, you may need to readjust the setting e.g. energy saving bulb, new curtains, new blinds. 4

Frequently asked questions Cleaning the front filters The pictures below are shown with a demonstration unit. 1 Once you are able to reach the main fan unit, open the front filter cover by gently pulling each cover in the direction marked by the arrow. The filters can then be simply pulled out from the unit so that they may be cleaned. 2 The filters are easily washed in lukewarm water by holding the filters under running water (clean side of the filter facing up into the flow and the dirty side facing the sink/bucket), thus pushing the dirt away from the filter. An abrasive rubbing action between the fingers and filter often helps, and in some cases a detergent will accelerate the cleaning process. If the filters cannot be cleaned, then it may be time for replacements to be purchased. Cleaning the rear filters 3 Isolate the fan from the mains supply before commencing this procedure and wait for the fan blades to stop rotating. 4 Open the front filter covers to expose the four screws and unscrew them with the tamperproof or crosshead screwdriver. 5 Gently lever the main fan unit away from the wall (a small distance only at this stage i.e. 5-10mm). This will allow the front filter covers to be removed without losing, dropping or damaging them if required, although it should be possible to completely remove the main fan unit from the wall with the covers in place. 5

6 The main casing can then be gently removed completely from the wall ensuring that the external cowl and smaller 125mm separator tube are not damaged or disturbed. 7 Remove the larger filters from the sides of the unit situated between the rear fan and aluminium heat exchange unit. Care should be taken to ensure that they are not damaged or torn. 8 The filters are easily washed in lukewarm water by holding the filters under running water (clean side of the filter facing up into the flow and the dirty side facing the sink/bucket) thus pushing the dirt away from the filter, an abrasive rubbing action between the fingers and filter often helps and in some cases a detergent will accelerate the cleaning process. 9 If the filters do not clean very well, then it may be time for replacements to be purchased. At this stage it may be wise to check the aluminium heat exchange unit to see if it requires to be cleaned/washed with a suitable cloth or fine brush - ensure the heat exchange unit is dry and that the electrical connections are not damaged or disturbed. Cleaning of the heat exchanger can be effectively done with a vacuum cleaner to ensure no dust is clogging it up thus reducing its efficiency. 10 You may also want to clean any dust or dirt that may have collected around the fan blades. It would also be recommended to give the inside of the wall pipe a wipe down prior to inserting the unit back inside it. Now the main fan unit is ready to be inserted back into the wall, ensure that the vital outer cowl assembly and 125mm separator tube (required for installation in walls which exceed 225mm depth) are still secured. Ensure that the fan unit is inserted the correct way up so that the electrical connection/terminal block will be sited properly, and that the front filter covers (if not already fixed) are located prior to the unit being pushed home to the wall plate (i.e. it will be impossible to insert the filter covers unless if the fan unit and wall plate are secured). 6

Proper maintenance will allow the fans to perform at their maximum efficiency to control the humidity levels within the room in which they are fitted. Proper maintenance will also prevent the fans switching to boost mode more frequently than is absolutely necessary. Washing the filters will also ensure a constant clean air supply. Reduction of humidity levels within a dwelling can substantially help to reduce dust mite activity - particularly of benefit to anyone in the household suffering from asthma or certain respiratory problems. Tell me more about the inside of my transformer LOW VOLTAGE OUTPUT MAINS INPUT SELECT EITHER SLOW OR FAST SPEED WITH 5AMP QUICK BLOW FUSE. FACTORY SEALED DO NOT ADJUST LIGHT LEVEL SENSOR ADJUSTMENT (See 4) TRANSFORMER HUMIDISTAT MODEL ONLY THUMB WHEEL HUMIDITY LEVEL ADJUSTER MAINS LED PULL CORD LED PULL CORD SWITCH (Manual trickle boost control) ALWAYS MAKE SURE YOU HAVE ISOLATED THE POWER SUPPLY PRIOR TO OPENING UP THE TRANSFORMER! Why are there two fuse positions on the circuit board? Over longer runs of cable between the transformer and the unit, resistance is increased. To compensate for this, the faster setting is the default position. Move the fuse to the slow position to reduce the voltage and hence the speed of the fan. This is useful for very short cable runs or to lower noise levels. Why is there a quick blow fuse in the transformer? The reason for using a quick blow fuse is to protect the circuit and components in the event of a power surge. These can be caused by problems with the building's wiring. If the fuse repeatedly blows, this indicates there is possibly a problem with your mains supply and you should have it checked by a qualified electrician. What is the factory sealed do not adjust rheostat? This is the humidity controller and should not be touched. If this is moved, the humidity being read by the sensor will not be matched with what is being displayed on the thumb wheel. 7

What is the light level sensor adjuster? This is the rheostat we used to adjust the amount of light the light sensor requires to go into boost mode. The sensor is factory set in the OFF position as this is preferred for most installations. This means the automatic boost feature will operate if the humidity rises during the hours of darkness. - Clockwise allows boost to operate during darkness - Anti-clockwise prevents boost operating during darkness I ve snapped my thumb wheel off my unit The following checks should only be carried out by a suitably competent electrician and require the removal of the transformer housing cover by use of a tamperproof driver / bit. 1 If the thumb wheel of your unit has been snapped off upon removing the transformer casing the spindle end of the thumb wheel may be left in the rheostat making it currently impossible to put a new thumb wheel in. Below we will show how to get this piece of plastic out and allow you to take control of the humidistat on your unit again. 2 To the right you will see two thumb wheels. The above wheel displays a broken thumb wheel and the below shows an intact one with the spindle. 3 To get the plastic piece out use one of the tamperproof screws taken from the transformer housing and have your tamperproof screw driver or power drill bit to hand. 8

4 Screw the tamperproof screw into the plastic with the tamperproof screw driver. Thread the screw into the broken spindle until attached. Do not remove the screw until you are certain it is secure to the plastic spindle. 5 Pull out the screw bit and the broken spindle should follow with some gentle force. The broken spindle can then be disposed of. Do NOT dispose of the screw as this will be required to hold the transformer housing in place. 6 Insert your new thumb wheel into the rheostat. Keep twisting the rheostat anti-clockwise. Do NOT force it when it has stopped as this means it is at its lowest setting. 7 Remove the thumbwheel once again and re-insert it with the number 20 (1 depending on model) displaying at the bottom of the transformer circuit board. Replace the transformer housing over the circuit board and fix in place with tamperproof screws and screwdriver. 9

Other Frequently Asked Questions The night sensor used to work but doesn't now - what's gone wrong? Light levels change with the seasons. Changing light bulbs or curtains can also have an effect. Ideally your night sensor should be adjusted twice a year for lighter or darker months. See our video guide for adjusting the night sensor. You, your landlord, agent or council can do this, or we can attend for our standard call out fee. How does a humidity sensor work? A humidity sensor measures the moisture content of the air. If the level rises beyond the set threshold, the humidity sensor switches to boost. The threshold is adjusted using the dial on the bottom edge of the transformer. The unit should be set at 50% as standard for ideal humidity levels. What are the filters for? Filters clean the air coming into the building to keep it free of dirt, smoke particles etc. Our units also filter the extracted air to protect and prolong the life of the heat exchanger, keeping it clean to keep it functioning efficiently. Pollen filters are also available, with a denser, finer mesh, to prevent allergens entering through the fan. The unit is blowing in cold air! This could mean the filters are clogged or blocked, which means less warmth is passed through the heat exchanger. What colour are the filters? If grey or black, they need cleaning or replacing. - Check the outside cowl is still attached to prevent cross-contamination. - Is your heating on? If the room is cool, the fan cannot recover much, if any, heat. The unit only recovers heat, it does not generate it. - The heat exchange efficiency is less when the unit is on boost. Moving air can feel cooler. Blow on your hand slowly, then quickly. The quicker air will feel cooler. The unit won't come off boost! Are two lights on? If yes, can you pull the pullcord? If nothing happens, the pullcord may be snagged. Isolate the mains, remove the transformer housing and make sure the pullcord is not tangled or snagged. The unit won't come on to boost! The humidity sensor may be damaged, or the white rheostat may have been adjusted by mistake. This needs to be re-calibrated using another humidity meter. Can I switch off the unit? This unit is designed to run constantly providing background ventilation and should be left on at all times. The unit comes onto boost at night time. The night sensor is improperly set. See page 4 10

Can I slow down the unit? Put the fuse in the slow position. See page 7 What thickness of wall/length of ducting l can I install the unit into? Up to 2 metres for mildly affected rooms, using the 1m extension kits we supply. How do you drill through a metre thick wall? With a long drill bit. Available from specialist suppliers. You could also drill from both sides and meet in the middle, or use extension drill bits. There is water in the unit or I get water on walls around the unit The core drilled hole should always be drilled at a 3 degree downward angle towards the outside. Interiors of holes drilled below ground level should be sealed, for example with mastic. At what height in my room should I mount the unit? Warm air rises, so the higher you mount the unit, the more heat you will recover. Where should I mount the transformer? Ideally 150mm below ceiling level, to allow a good amount of light to get to the sensor. Can you mount the unit through a roof? No, because rainwater, or condensation will drip out of the fan. I've installed the machine but I still have mould. What setting is the dial at? Usually it should be set at 45-55. Did you clean the mould off? How long ago? What with? Bleach won't work, as it is a germicide not a fungicide (mould is a fungus). These machines won't actually clean mould off your walls. They will only stop it re-growing. Are there obstacles to air circulation like bulky furniture, or over-packed wardrobes? Do you habitually dry your laundry in that room? Do you close your bathroom and kitchen doors? Leaving them open will increase demand on a unit in a different room. Can I use a different humidistat? Yes you can, but you would need a separate transformer from 240v to 12vAC, as well as a separate humidistat. I have mould in odd straight or regular patterns, despite having an HRV unit installed. Cold bridging - the disruption of cavity walls or insulation by a solid material allows the outside temperature to penetrate. This results in stripes of mould over beams or spots over nail heads. Our units are not designed to deal with this, rather it is a physical characteristic of your building and needs a separate treatment such as thermal wallpaper or anti condensation coating. 11

Registration Register your unit online now. If you register within 14 days of purchase you will receive an extra filter set free. Step 1 You will need the following information to hand to register your first set of replacement filters FREE. The serial number of your HRV unit. (Found on the packaging box or inside left filter cover) Date of purchase. Your full name and address - including post code Your email address Step 2 Fill in the online form, visit www.kair.co.uk/register or scan this QR code. Step 3 Once we have received your fully completed registration we will despatch your FREE filters. The warranty Applicable only to products installed and used in the United Kingdom. For details of warranty outside of United Kingdom, contact your local supplier. Kair guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s option replaced, without charge, provided that the product: Has been maintained / serviced in accordance with instructions given. Has been installed and used in accordance with the instructions given with each unit. Has not been connected to an unsuitable electrical supply. Has not been subject to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product, carriage paid to your original supplier or nearest Kair centre, by post. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing evidence of date and source of purchase. The guarantee is offered to you as an extra benefit, and does not affect your statutory rights. Version: 20130731 Phone: 08451 66 22 40 Fax: 08451 66 22 50 Web: www.kair.co.uk Email: info@kair.co.uk Address: 6 Chiltonian Industrial Estate, Manor Lane, Lee, London SE12 0TX As part of our policy of continuous product development, Kair reserves the right to alter specifications without notice. 12