CLINI SAFE. The safest choice for Health Care Establishments NEW PRODUCT FEATURES. 5 Cleaning methods. Fire reaction: A1

Similar documents
CI/SfB. September MediCare range. MediCare Standard. MediCare Plus. MediCare Air

Part of the ROCKWOOL Group. Healthcare Spaces. Ceiling solutions for a better way to heal

Patient Compartment Light

H M H M H M H M H M H M H M B A R R I E R W A S H E R E X T R A C T O R S

SBS Design Considerations for Autoclave Sterilization

CLEANING AND DISINFECTANT WIPES

A comparative study of different hand drying methods: paper towel, warm air dryer, jet air dryer.

Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects?

CEILING SYSTEMS. [ Between us, ideas become reality.] Bioguard. The Anti-Bacterial Coating

Current Sterilisation Process Content of the Presentation. Content of the Presentation. Prof (Col) Dr RN Basu. Content

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

10 Second Machine. 10 Seconds to Better Health Ozone Faucet Systems by Cashido Corporation

Specialist Cleaning System & Long Lasting Residual Disinfection Solution

Elers Medical Antimicrobial

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

SAFETY TECH. RRL Pendulum Test >36 (wet test) EN Class DS Bacterial resistance

SUMMARY OF ANTIMICROBIAL ACTIVITY

Filmop A-B PLUS. Anti-Bacterial System

Integrated Ozone technology based solution For Hospital

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

The Latest Innovations in Hand Washing Technology

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Ecophon Solo Baffle Wave

The ultimate microbiological safety cabinet

ONE-STEP DETERGENT DISINFECTANT

CLEANING OF INSTRUMENTS

H 2 Orange 2. Hyper-Concentrate 112 Sanitizer/Virucide Cleaner DANGER

DISINFECTING 99.9% KILLS. 1.7 OZ (47 g) Wet Floor Cloth WET MOPPING CLOTHS. Tuscan Lavender & Jasmine KEEP OUT OF REACH OF CHILDREN CAUTION:

CHAP. 01 PAGE 6 CHAP. 02 PAGE 32 CHAP. 03 PAGE 71 MECHANICAL VENTILATION

Hospital ventilation & infection prevention

CAUTION: EYE IRRITANT. Economy Size 32 FL OZ NET 1 QT (32 FL OZ) 946 ml KEEP OUT OF REACH OF CHILDREN SEE BACK PANEL FOR PRECAUTIONARY STATEMENTS

THE THREATS YOU CAN T SEE. THE DIFFERENCE YOU CAN.

industrial sanitizing with ecological dry steam hospitality, community & health care

Cleaning and Sterilization for Instruments & Posts

Housekeeping and Laundry Ulrika Ransjö

Integrated Ozone Technology based solution For Eco-Friendly Hospital

Create Clean Air. The specialists in Indoor Air Quality

HPL and solid grade (Compact) through-colour laminate

AirGuard Coating. Ceiling. For Ultima Ceiling Panels. A revolutionary breakthrough to actively remove formaldehyde in buildings

english industrial sanitizing with ecological dry steam

Investigation of the Performance of the Air Purifier in High-Risk Hospital Rooms by Counting Particles

UVC in the Operating Room.

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Intelligence and Beauty

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

Theatre Classification and Air Particle Count Is that Surveillance?

Professional Air Decontamination

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

Dietary Department, Infection Control

The revolutionary single-use system

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

HPL and solid grade (Compact) through-colour laminate

Mediclean Complanate Ultra Clean Ventilation

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Cleaning & Sanitising Food processing industry. Replacing synthetic cleaners & sanitisers by natural alternatives

Floor cleaning: effect on bacteria and organic materials in hospital rooms

256 Century Q is a no-rinse neutral ph disinfectant cleaner that disinfects and cleans in one labor saving step.

GOODLIGHT LED. Dynamic Lighting. Normal care / Wall lighting unit

I.F.U Re/Processing Reusable Medical Devices

Cleaning and disinfecting

Bacteria in Household Sponges: A study testing which physical methods are most effective in decontaminating kitchen sponges

HVAC Efficiency In Healthcare. Presenter Mr. Nate Lincoln

OWNER S MANUAL. Global Ozone Innovations, LLC. 425 Pine Creek Court, Elkhart, IN 46516; Phone ; Fax

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Additional reaction to fire classification report No H

SANITIZER Applicable for SFS16, SFS17, SFS18, CP1617, CP1603, CP1605

Y o u r H e a l i n g P a r t n e r f o r e c o l i f e. Instruction manual. MODEL Power supply Input AC 100~240V / 50/60Hz. 236mmx257.2mmx311.

Safe Operating Procedure (Revised 2/10)

HOMES AND SENIORS SERVICES. APPROVAL DATE: April 2004 REVISION DATE: March 2016 REVISION DATE: March 2017 REVIEW DATE: November 2018

To: Mr. Michael Jennison-President Mr. Michael F. Busa-V.P. New Product Development, Sales and Marketing 54 Arch Street Carnegie, PA

Always ensure that surfaces that are being disinfected are compatible with the product being used.

Intensive UV light means not a chance for germs!

Technical Bulletin Disinfectant/Sanitizer/Virucide* Fungicide^/Algaecide/Slimicide/Bactericide/Deodorizer

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية


Basic Cleaning Concepts

COMPONENTS SOLUTIONS MAINTENANCE PRODUCTS. for refrigeration and air conditioning systems

Central Sterile Services Department will receive, decontaminate, process, store and/or dispense sterile and non-sterile to departments requesting.

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

When you sterilize an instrument set, you know what the standards are.

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Solution: Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects? OR PACKAGE

PACKETS - Open and pour contents into.25 gallons of water (or equivalent dilution). Keep packets in box until ready to use.

Healthcare Solutions. Water, faucets, and the fight against healthcare-associated infections (HAIs)

SilvaClean Antimicrobial Laundry Additive

RVTM3 SUCTION VACUUM REGULATORS

Support for staff involved in the use of steam cleaning machines. C21/HCQAI Criterion 2 Outcome 8 & 10

RVTM3 SUCTION VACUUM REGULATORS

Tru-D Rapid Room Disinfection

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Inactivation of quaternary disinfectants by cleaning cloths containing laundry detergent residues is cause for concern.

CPX RIGID PENDANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

What is the Problem? Enemy Number 1 Biofilms/Bioslim. Two Common Enemies We Fight

Mini Guide to hygienic laundry practices. based on the RABC system/en 14065

Inside your life! LG Innotek's innovative technologies will take you to a safe, convenient and enjoyable future. 7 th, May 2018

Humidity Control Combats Healthcare Associated Infection

Transcription:

NEW CLINI SAFE PRODUCT FEATURES The safest choice for Health Care Establishments Tested on the 3 criteria in French Health Standard NF S90-351: 2013 ISO 4 - CP5 - M1 5 Cleaning methods Fire reaction: A1

CLINI SAFE The safest choice for Health Care Establishments The French Standard NF S90-351: 2013, control of airborne contamination, is applicable to Health Care Establishments and similar centres. This new standard replaces Standard NF S90-351 2003 and revises some of its characteristics. THE MAIN THREE CRITERIA IN FRENCH STANDARD NF S90-351: 2013 Control of Air Particle: ISO class Determines the concentration of particles emitted by the ceiling into the room. Lower the ISO rating, less polluting is the ceiling Kinetics of particle decontamination - Expressed in CP (minutes) Represent the time necessary to achieve 90% decontamination from an initial pollution peak. The shorter the time, the less the ceiling retains pollution Microbiological cleanliness - The classification is expressed by an index between 1 and 100 - Certifies that the ceiling is not conducive to the development of bacteria. - The bacteriological class (B) becomes the microbiological cleanliness-class (M) in August 2013. BEFORE AFTER The lower the index, the more resistant is the ceiling to the proliferation of bacteria APPLICATION ZONES: Health Care Establishments are classified in four zones depending on the usage made of the room, the vulnerability of the patient, the risk of biocontamination, the nature and duration of care administered to the patient, etc. Zone 1: Low risk zone : Corridors, waiting rooms, reception. No specific requirements. Zone 2: Medium risk zone : Multi-function room, imagery room. Requirements in standard: ISO 8 - CP20 - M100 Zone 3: High risk zone : Cardiovascular surgery room, obstetrics room, operational imagery room. Requirements in standard: ISO 7 - CP10 - M10 Zone 4: Very high risk zone : Prosthetic orthopaedics room, operating theatre. Requirements in standard: ISO 5 - CP5 - M1

NEW CLINI SAFE Performances adapted to Health Care Establishments The Clini Safe ceiling range satisfies safety requirements for all zones. It provides patients and healthcare personnel with the necessary acoustic comfort due to a high alphasabin coefficient. It also has a very good light reflection coefficient that contributes to the well-being of users (patients and healthcare personnel). + SAFETY Tested on the 3 criteria of French Health Standard NF S90-351: 2013 Fire reaction: A1 Fire resistance: SF 30 (1) Clini Safe A 15 mm ceilings (600 x 600 and 1200 x 600 mm) installed on a QUICK-LOCK, T24 frame are SF 30 (1) according to Belgium Standard NBN 713-020. No sagging regardless of the moisture content + CLEANLINESS Cleaning methods tested by an independent laboratory - Compressed air - Wet sponge with or without detergent/disinfectant CLINI SAFE CEILINGS ACCORDING TO THE STANDARD FOR HEALTH CARE ESTABLISHMENT CONTROL OF AIRBORNE PARTICLES ISO4 KINETIC OF PARTICLE DECONTAMINATION CP5 MICRO BIOLOGICAL CLEANLINES M1 (according to strain) M10 (according to strain) RISK ZONE Zone 4 Zone 3 - Wet steam with dry cloth + COMFORT Acoustic absorption: α w = 0.90 Light reflection index: 85% (1) See reference classification report Decorative glassfibre veil coated with white paint High density stone wool panel, 15 mm thick Decorative glassfibre veil coated with white paint High density stone wool panel, 15 mm thick Clini Safe Natural glassfibre veil on the reverse side A Edges, painted Natural glassfibre veil on the reverse side E Edges, painted A EDGE E EDGE

CLINI SAFE + SAFETY The 3 criteria in French standard NF S90-351 2013. - Clini Safe ceilings do not create pollution: Based on the Control of Airborne Particles in Standard ISO 14644-1: ISO 4. - Clini Safe ceilings do not retain pollution: According to the rate of Kinetic of particle decontamination : CP5. - Clini Safe ceilings prevent bacteria from developing: According to the microbiological cleanliness class: M1 (1) or M10 (1) depending on the strains tested. Fire safety. - Clini Safe ceilings have the best possible classification in terms of fire reaction: A1, incombustible. - Clini Safe A 15 mm ceilings used on a QUICK-LOCK frame give a fire reaction equal to: SF 30 (2) according to standard NBN 713-020. Resistance to humidity. - Clini Safe ceilings remain perfectly flat regardless of the humidity due to the intrinsic qualities of Eurocoustic stone wool. ZOOM ON TESTED BACTERIA STREPTOCOCCUS PNEUMONIAE: Most common cause of bacterial meningitis and pneumonia. ASPERGILLUS BRASILIENSIS (NIGER): Can cause permanent hearing loss, or even death of the patient, when immunodeficient. BACILLUS CEREUS: Responsible for opportunist food poisoning. ESCHERICHIA COLI: Can be pathogenic leading to gastroenteritis, urine infections, meningitis or septicemia. CANDIDA ALBICANS: Causes fungal infections essentially in digestive and gynaecological mucous membranes. ACINETOBACTER BAUMANII: At the origin of a variety of occasionally severe infections (lung infections, infections of wounds or burns, etc.). STAPHYLOCOCCUS AUREUS RESISTANT TO METICILLIN: Causes suppurative skin infections, otitis and sinusitis, acute myositis, infections of the respiratory tract, phlebitis, meningitis, bone infections, etc. KLEBSIELLA PNEUMONIAE: Active in the case of nosocomial pneumonia. (1) See certificates (2) See reference classification report + CLEANLINESS Clean and easily maintained ceilings. 5 cleaning methods tested by an independent laboratory - For each type of soiling medium, the laboratory recommends a tested cleaning method. Dust Dirty water + dust Grease Compressed air Wet sponge Wet steam + dry cloth Wet sponge with detergent Wet sponge with disinfectant Wet steam + dry cloth - Increased resistance to manipulation due to its high density stone wool panel and its easy-to-clean painted finish.

+ COMFORT Comfort in rooms. - Acoustic absorption: Clini Safe ceilings have an α w = 0.90. - High coefficient of light reflection: Clini Safe ceilings have a coefficient of light reflection higher than 85%, so that users can benefit from more luminosity and a more comfortable environment. THE CHOICE AND PERFORMANCES Dimensions: Thickness (mm) Modules dimensions (mm) CLINI SAFE A CLINI SAFE E 15 15 600 x 600 1200 x 600 600 x 600 1200 x 600 A Edge E Edge Colours, decors and finishes: Colour: White Finish: Painted face and edges Stay connected with CLINI SAFE VIEW THE CLINI SAFE VIDEO OR

A Edge T15 T24 15 mm Clini Safe A > > Rigid stone wool self-supporting panel > > Painted with a white finish on the visible side > > Painted edges > > Reinforced by a natural glassfibre veil on the reverse side A Acoustic absorption α 1.0 0.8 0.6 0.4 0.2 0 125 250 500 1,000 2,000 4,000 α = 0,90 : Class A Hz w C Light reflection The light reflection coefficient is greater than 85% for white. B Fire reaction According to standard EN 13501-1: Euroclass A1 for white. J Fire resistance: Clini Safe A 15 mm (600 x 600 and 1200 x 600 mm) ceilings installed with a T24 QUICK-LOCK FRAME (see reference test report) satisfy the requirements of clause C013 in the fire regulations for ERP (buildings open to the public). D Resistance to humidity No sagging regardless of the moisture content. E CE marking DoP No: 0007-04 M Indoor air quality Clini Safe A 15 mm ceilings are class A. N Behaviour in Health Care Establishment French Standard NF S90-351: 2013, control of airborne contamination: Zones Control of Airborne Particles Kinetics of Particle Decontamination Microbiological cleanliness 4 ISO 5 CP5 M1 3 ISO 7 CP10 M10 2 ISO 8 CP20 M100 Zones Clini Safe A 15 mm ceilings satisfy microbiological requirements for type 4 and 3 zones: Control of Airborne Particles Kinetics of Particle Decontamination Microbiological cleanliness 4 ISO 4 CP5 M1 3 ISO 4 CP5 M10 Tested bacteria Escherichia coli, Klebsiella pneumoniae, Aspergillus niger, Candida albicans Acinobacter baumannii, Bacillus cereus, Streptococcus pneumoniae, Staphylococcus aureus resistant to methicillin (SARM) G Installation It should comply with the requirements of standards in force depending on the nature of the rooms. It is recommended that air circulation should be provided between the rooms and the plenum to balance the temperature and pressures on each side of the ceiling. Clini Safe A 15 mm ceilings are placed on a T15 - T24 frame. Tiles are cut without noise or dust using a cutter. P Cleaning The painted surface of Clini Safe A 15 mm ceilings does not retain dust, which makes it easier to clean. Clini Safe A 15 mm ceilings can be cleaned with a lightweight brush, vacuum cleaner, compressed air, wet sponge (with or without detergent / disinfectant), wet steam + dry cloth. Clini Safe A 15 mm ceilings are resistant to the most widely used disinfectants in hospitals, with a base of hydrogen peroxide, chlorine dioxide and glutaraldehyde. Appropriate cleaning will help lengthenclini Safe A 15 mm ceilings life duration. SUMMARY TABLE Colours Edges Frames Module dimensions (mm) White A T15 - T24 Width 600 600 Length 600 1200 Thickness 15 15 Packaging Panels / Pack 24 12 m² / Pack 8.64 8.64 Packs / Pallet 22 22 Service class A C Clini Safe A 15 mm ceilings are packaged in 6-sided boxes. All Eurocoustic packs are shrink-wrapped.

E Edge T15 T15 Hollow joint T24 15 mm Clini Safe E > > Rigid rock wool self-supporting panel > > Painted white finish on the visible face > > Painted edges > > Reinforced by a natural glass facing on the reverse side A Acoustic absorption α 1.0 0.8 0.6 0.4 0.2 0 125 250 500 1,000 2,000 4,000 α = 0,90 : Class A Hz w C Light reflection The light reflection coefficient is greater than 85% for white. B Fire reaction According to standard EN 13501-1: Euroclass A1 for white. D Resistance to humidity No sagging regardless of the moisture content. E CE marking DoP No: 0007-04 M Indoor air quality Clini Safe E 15 mm ceilings are class A. G Application Shall comply with the requirements of standard in force depending on the nature of the rooms. It is recommended that air circulation should be provided between the rooms and the plenum to balance the temperature and pressures on each side of the ceiling. Clini Safe E 15 mm ceilings are placed on a T15 - T15 hollow joint - T24 frame. Tiles are cut without noise or dust using a cutter. P Cleaning The painted surface of Clini Safe E 15 mm ceilings does not retain dust, which makes it easier to clean. Clini Safe E 15 mm ceilings can be cleaned with a lightweight brush, vacuum cleaner, compressed air, wet sponge (with or without detergent / disinfectant), wet steam + dry cloth. Clini Safe E 15 mm ceilings resist to the most widely used disinfectants in hospitals, based on hydrogen peroxide, chlorine dioxide and glutaraldehyde. Appropriate cleaning will help lengthen Clini Safe E 15 mm ceilings life duration. SUMMARY TABLE Colours Edges Frames Module dimensions (mm) White E T15 - T15 hollow joint - T24 Width 600 600 Length 600 1200 Thickness 15 15 Packaging Panels / Pack 24 12 m² / Pack 8.64 8.64 Packs / Pallet 22 22 Service class A C Clini Safe E 15 mm ceilings are packaged in 6-sided boxes. All Eurocoustic packs are shrink-wrapped. N Behaviour in hospitals and clinics Standard NF S90-351: 2013, control of airborne contamination: Zones Control of Airborne Particles Kinetics of Particle Decontamination Microbiological cleanliness 4 ISO 5 CP5 M1 3 ISO 7 CP10 M10 2 ISO 8 CP20 M100 Clini Safe E 15 mm ceilings satisfy microbiological requirements for type 4 and 3 zones: Zones Control of Airborne Particles Kinetics of Particle Decontamination Microbiological cleanliness 4 ISO 4 CP5 M1 3 ISO 4 CP5 M10 Tested bacteria Bacillus cereus,streptococcus pneumoniae, Aspergillus niger, Candida albicans Klebsiella pneumoniae, Staphylococcus aureus resistant to methicillin (SARM)

Sales Back office Loubna NEFARI Tél. : (+33) 1 56 37 03 88 Fax : (+33) 1 56 37 02 69 loubna.nefari@saint-gobain.com Technical Assistance Delphine DRAY Tél. : (+33) 1 56 37 03 87 Fax : (+33) 1 56 37 02 69 delphine.dray@saint-gobain.com www.eurocoustic.com Saint-Gobain Eurocoustic 1, place Victor Hugo 92411 Courbevoie Cedex France Phone: (+33) 1 56 37 02 40 Fax: (+33) 1 56 37 02 69 Non-contractual document, given for information. - Eurocoustic reserves the right to modify the characteristics. - Photo credits: Thinckstock. 08/2015 - Saint-Gobain Eurocoustic - Limited company with a capital of 4 000 000-307 390 104 RCS Gueret - Head Office: ZI Bellevue, 23350 Genouillac, France.