1100X Wireless Receivers

Similar documents
1100D Wireless Receiver

1164/1164NS WIRELESS SMOKE DETECTOR

SZ-PIR04N ZigBee Motion Detector Installation Guide

1126 Series Ceiling Mount PIR Motion Detector

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

1125 PIR Motion Detector

Wi-Fi DOOR/WINDOW SENSOR

Wireless Outdoor Air Reset Adaptor PN:

Rev D 3/20/17

ADT. Pulse 2017ADT LLC

Atomic Digital Office Clock

Automatic Dimming Mirror with HomeLink

Optima ZigBee Thermostat

2 x screws. 2 x wall plugs

ShockLink. Important Product Information.

Wireless Weather Station

Smart Hub THERMOSTAT. Installation Manual

Pet Immune SAW PIR Motion Sensor

INSTALLATION GUIDE XTLN-WIFI PANEL

Wireless External Alarm

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Smart THERMOSTAT. Installation Manual

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

1134 Wireless Wiegand Module INSTALLATION AND PROGRAMMING GUIDE

Draft - develop and review

Impassa CDMA Module INSTALLATION GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

EL-TSTAT Owner s Manual

PET IMMUNE PIR MOTION DETECTOR

XTLC PANEL INSTALLATION GUIDE

S541.RF 4G Product Guide

Features and content. This is where air comes into your detector.

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Touchscreen Comfort Control

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Panel XTO210/610/710 GPRS

Contents. User Manual GA-U-1. VultureNet: Long Range System

Smoke Bridge Owner s Manual

Smart Radon Detector with Indoor Air Quality Sensors

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

SuperCELL Model SC500-H-SM User s Information

Badge Reader BR Installation Guidelines. Product Summary

Door/Window Sensor Installation Instructions

XL200L/600L/700L GPRS Control Panel

Water Sensor. Model CFWS10

InTemp CX Temperature Logger (CX40x) Manual

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

Panel XT210/610/ Description. Supervised Wireless Technology

ADC-T2000. Smart Thermostat v1.5

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

ecobee 3 Quick Start Guide Installation Guide DRAFT

Tech Support Line: (715) Concord 4 RE927X

GARAGE DOOR OPENER KIT

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

RE6100 Series Helix Security and Automation Platform E I D

Technical support is also available by or by phone: (North America) (International)

XTO-IP ALARM PANEL. Description. Supervised Wireless Technology. Features

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

XV 210 GPRS Control Panel

XT-iP 210 Control Panel

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD240)

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions (YRD220)

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 6 Mounting 7 Probe Use 8 Probe Wrap Use 9

Intelli-Time Alarm Clock model 13041RM

EN1221S-60 Waterproof Pendant Installation and Operation Manual

PRODUCT DIAGRAM PACKAGE CONTENTS

Yale Real Living Touchscreen Lever Installation and Programming Instructions (YRL220)

1 Copyright 2015 Alarm.com. All rights reserved. Rev 3.4

1 Copyright 2014 Alarm.com. All rights reserved. Rev 3.3

Caught a critter in the act?

Nest x Yale Lock Programming/Troubleshooting Guide

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

How to install your ecobee4

Monnit Wireless Local Alert. User s Guide

PRODUCT DIAGRAM PACKAGE CONTENTS

W8735ER Wireless Outdoor Reset Module

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

BE1310 Visit Smart hub

Installer Guide smart connect

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

1161/1162 Residential Wireless Detectors

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

SYSTEM ENHANCEMENT MODULE

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Installer Guide smart connect

Transcription:

00X Wireless Receivers INSTALLATION GUIDE Description The 00X Wireless Receiver is compatible with all DMP wireless devices. The receiver provides two-way, supervised communication using 900 MHz frequency hopping-spread-spectrum technology. The receiver can be mounted up to,000 feet from the panel enclosure. The receiver provides up to 500 wireless zones. Refer to the panel installation guide for number of available wireless zones. Compatibility XR50/XR550 Series panels What is Included One Model 00X Wireless Receiver One 4-wire Harness Hardware pack Compliance Instructions For applications that must conform to a National Recognized Testing Laboratory certificated system, please see the Listed Compliance Specifications section at the end of this guide for additional instructions. Installing the Wireless Receiver Selecting a Location Choose an optimum location to mount the receiver. The 00X Wireless Receiver is typically mounted at a distance not to exceed 000 feet away from the panel enclosure. A location should be selected that is centrally located between the 00 Series transmitters used in the installation. Install the receiver away from large metal objects. Mounting the receiver on or near metal surfaces impairs performance. Do not use shielded wire between the panel and receiver. When selecting the proper mounting location of a transmitter, refer to the LED Survey Operation section of the specific installation guide for the transmitter being installed. Tamper Switches The 00X is equipped with a case tamper and a wall tamper. Mounting the Receiver. Remove the cover from the plastic housing by squeezing both sides toward each other. 2. Secure the receiver to the wall ensuring the two antennas are pointing up and the wall tamper switch makes proper contact with the wall. Use the supplied screws in the mounting hole locations as shown in Figure. LEDs Panel Receive Panel Transmit RF Receive RF Transmit Mounting Screw Shoulder Washer Mounting Hole Locations J J4 Squeeze to Remove Cover U7 U4 RF U5 Tamper Switch Squeeze to Remove Cover PANEL J Connects To Panel Figure : Receiver PCB

Wireless Bus Connection On XR50/XR550 Series panels, the 00X interfaces using the on-board X-Bus connection. Note: The 00X Wireless Receiver cannot operate if connected to the Keypad Bus. Harness Connection XR50/XR550 panels. Connect the PANEL header on the 00X to the XR50/XR550 panel X-BUS header. 2. After power-up, briefly reset the panel using the RESET jumper to activate wireless zone operation.. In System Options, program the House Code (-50). In Zone Information, program the wireless zones.. Snap the cover back on the unit. The panel immediately recognizes the 00X Receiver if the panel is programmed with a house code. LED XR50/XR550 Series Panel 00X Receiver Battery Start J J4 XMT - Transmit LED REC - Receive LED U4 RF U5 U7 PANEL RED J Red Yellow Green Black Can be extended up to 00 feet from the panel using 22 AWG or 250 feet using 8 AWG Figure 2: XR50/XR550 DMP Wireless Bus Connection 00X Receiver Operation The 00X receiver automatically sends the panel house code to wireless transmitters when the unique transmitter serial number is programmed into the panel. The house code identifies the panel, receiver, and transmitters to each other. The receiver only listens for transmissions using the specified house code and/or programmed transmitter serial number. Note: When setting up a wireless system, it is recommended to program zones and connect the receiver before installing batteries in the transmitters. Transmitters can be programmed for supervised operation. When programmed as supervised, the transmitter must communicate with the receiver within the programmed number of minutes. If the transmitter fails to communicate, the panel displays a missing condition. Note: When a receiver is installed, powered up, or the panel is reset, the supervision time for transmitters is reset. If the receiver has been powered down for more than one hour, wireless transmitters may take up to an additional hour to send a supervision message unless tripped, tampered, or powered up. This operation extends battery life for transmitters. A missing message may display on the keypad until the transmitter sends a supervision message. When any wireless zone programming is changed in the panel, receiver zone programming is updated. At that point, all wireless zones display as normal for approximately one minute, regardless of the actual state of the contact. 00X LED Operation Six LEDs display receiver operation and activity. Refer to the table below as required. PCB LEDs Label Operation RF POWER STATUS RF Steady green to indicate there is power to the receiver. Flashes yellow to indicate data is being received from the panel. Flashes green to indicate data is being sent to the panel. Steady red to indicate memory upload. Off when upload is complete. Flashes yellow to indicate data is being received from a transmitter. Flashes green to indicate data is being sent to a transmitter. 2 00X Wireless Receiver Installation Guide

Transmitter Survey LED Operation DMP 00 Series transmitters provide Two-way (transmit acknowledge) operation. This advanced data protocol allows each transmitter to confirm that each of its messages (alarm, checkin, tamper, low battery) are received and acknowledged by the 00 Series receiver. The confirmation is indicated visually by use of an LED on each transmitter. This Survey LED should be used during installation to test each transmitter for proper operation. A full definition of the Survey LED follows. The red LED on an 00 Series transmitter turns on when the processor wakes up to send a message. Then after a series of communication steps are completed (successful or not), the LED turns off when the processor goes back to sleep. 99.9% of the time the processor is asleep in normal operation. The following list summarizes various indications that can be observed on the LED and a definition for each. Note this is for a single message. Example, pressing and holding the tamper switch. Single /6 second flash Transmitter receives immediate synchronization from receiver Transmitter transmits Transmitter receives immediate acknowledgement from receiver Processor goes to sleep Single Pulse greater than /6 second but shorter than 8 seconds Transmitter receives synchronization from receiver - possibly not immediate Transmitter transmits Transmitter receives acknowledgement from receiver - possibly not immediate Processor goes to sleep Steady for 8 seconds Transmitter never receives synchronization from receiver, or might receive synchronization Transmitter transmits if synchronization was received Transmitter never receives any further data from receiver Processor times out and goes to sleep Multiple short flashes Transmitter receives synchronization from receiver Transmitter transmits Transmitter receives data from receiver, but not a valid acknowledgement Processor briefly goes to sleep Entire sequence is repeated, each short flash indicates a cycle 00X Wireless Receiver Installation Guide

Troubleshooting Using the Transmitter Survey LED If a transmitter is unable to reliably communicate a message to the receiver, or is reported as missing, the Survey LED can be used to help diagnose the issue. If the missing transmitter cannot be explained by obvious reasons such as a damaged transmitter, failed battery, or changes in building construction; then the Survey LED should be used. To use the Survey LED operation to help diagnose a field issue, complete the following steps on an 00 Series transmitter. Repeat the following sequence 5 times and write down the LED operation for each tamper switch action. Press and hold the tamper switch Observe the LED until it turns off for at least 5 seconds Release the tamper switch Observe the LED until it turns off for at least 5 seconds You now have observed the LED 0 times. Based on the results you have recorded use the list below to assist in troubleshooting. LED turns on a single time for less than second 8 to 0 times. System is working properly LED turns on for more than second to 9 times. The transmitter or receiver needs to be relocated LED turns on for more than second all 0 times. The receiver is not turned on, or is not operating The transmitter is not programmed into the receiver The transmitter or receiver needs to be relocated LED flashes multiple times with a single tamper press or release to 0 times. The transmitter or receiver needs to be relocated LED never turns on. The transmitter battery is dead The tamper switch is being pressed or released too quickly The tamper switch or other part of the transmitter is broken LED stays on constantly and is dim The transmitter battery is almost dead The transmitter is broken General Wireless Troubleshooting If ALL wireless devices do not operate, refer to the following checklist: Verify the receiver is an 00X and the panel is an XR50/XR550 Series panel. or Verify the PANEL header from the receiver is connected to XBUS header on the XR50/XR550 panel. Briefly reset panel using RESET jumper to activate wireless operation and wait one minute to test wireless zone(s). Verify the House Code (-50) is programmed in System Options. Verify appropriate zone numbers are assigned as wireless zones. Verify that the panel XMIT and REC LEDs alternately flash on and off at a rate of /4 second each. If the LEDs are On steady or Off, the panel and receiver are not communicating properly. (See Figure ). Verify the 00X LEDs operate correctly as listed in 00X LED Operation. Verify transmitters have batteries correctly inserted. 4 00X Wireless Receiver Installation Guide

Listed Compliance Specifications Commercial Fire Transmitters must be programmed as supervised. Refer to the Transmitter Supervision Time table for the supervision time. The maximum line impedance of the 4-wire bus is 6.2 Ohms for 000 feet. The recommended wire gauge for panel to receiver connection is 22 AWG. After all transmitters are in position, the WLS option of the panel s Walk Test must be operated and all transmitters programmed for Fire (FI) or Supervisory (SV) must show that their checkin message was received. Refer to the panel programming guide for Trip Counter for DMP Wireless check-in Test (WLS) which describes that both numbers of the counter must match. If not and a failed wireless zone is displayed at END, decrease that transmitters range with the receiver and perform the WLS Walk Test again. Transmitter Supervision Time For UL Listed installations, program the transmitter supervision time in panel zone programming as listed in the following table. Refer to the panel programming guide for complete wireless programming information. UL Listing UL 02 Household Burglary Alarm System Units Accessory Listed Accessories 00R Repeater 0/02/0/06 Universal Transmitters 27W/27C PIR Motion Detector 5 Wireless Sounder 42 Two-Button Hold-Up Transmitter 90/906 Wireless Keypad Supervision Time UL 66 Holdup Alarm Units and Systems Accessory 42 Two-Button Hold-Up Transmitter UL 64 Connections and Switches for use with Burglar Alarm 00R Repeater Systems Accessory 0/02/0/06 Universal Transmitters UL 69 Intrusion Detection Units Accessory 00R Repeater 27W/27C PIR Motion Detector UL 65 Police Station Connected Burglar Accessory 00R Repeater 0 Universal Transmitter UL 9 Local Burglar Alarm Units and System Accessory 00R Repeater 0 Universal Transmitter UL 076 Proprietary Burglar Alarm Units Accessory 00R Repeater 0 Universal Transmitter UL Central Station Burglar Alarm Units Accessory 00R Repeater 0 Universal Transmitter 5 Wireless Sounder 90/906 Wireless Keypad UL 268 Smoke-Automatic Fire Detectors 00R Repeater 64 Wireless Synchronized Smoke Detector UL 52 Heat Detectors for Fire Protective Signaling Systems 00R Repeater 8-5F/8-5R Heat Detector UL 985 Household Fire Warning System Accessory 00R Repeater 5 Wireless Sounder 240 90/906 Wireless Keypad UL 864 Fire Protective Signaling Systems 0 Universal Transmitter 00R Repeater UL 2075 Gas and Vapor Detectors and Sensors 84 Wireless Carbon Monoxide Detector 240 00X Wireless Receiver Installation Guide 5

FCC Information This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions () This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/tv technician for help. Note: The 00 Series wireless system is a two-way supervised wireless design compliant with FCC rules as they pertain to 900 MHz Spread Spectrum devices. In rare instances it has been observed that certain 900 MHz cordless telephones may occasionally experience a clicking sound on the telephone while in use. If this occurs, it may be resolved by selecting a different channel on the cordless telephone, or replacing the cordless phone with a different brand or model of 900 MHz telephone or other cordless telephone. To comply with RF exposure requirements, a minimum distance of 20cm must be maintained between the antenna and all persons. Industry Canada Information This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:. This device may not cause interference, and 2. this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes:. l appareil ne doit pas produire de brouillage, et 2. l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. This system has been evaluated for RF Exposure per RSS-02 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits. L exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-02 et est jugée conforme aux limites établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l antenne d une personne présente en conformité avec les limites permises d exposition du grand public. Specifications Operating Voltage Current Draw RF Rating Frequency Range Dimensions Receiver Housing Antennas Color Housing Material Patents U. S. Patent No. 7,29,26 8.0 to 4VDC 46mA 27mW 905-924 MHz 4.65 L x. W x.4 H 8.6 H White Flame retardant ABS 800-64-4282 INTRUSION FIRE ACCESS NETWORKS www.dmp.com Certifications California State Fire Marshal (CSFM) FCC Part 5: CCK00 Industry Canada: 525A-PC0082 New York City (FDNY COA #667) Underwriters Laboratory (UL) Listed ANSI/UL 65 Police Station Connected Burglar ANSI/UL 9 Local Burglar Alarm Units and Systems ANSI/UL 64 Connections and Switches for use with Burglar Alarm Systems Accessory ANSI/UL 66 Holdup Alarm Units and System ANSI/UL 69 Intrusion Detection Units Accessory ANSI/UL 02 Household Burglar Alarm System Units ANSI/UL 076 Proprietary Burglar Alarm Units ANSI/UL Central Station Burglar Alarm Units ANSI/UL 864 Fire Protective Signaling Systems ANSI/UL 985 Household Fire Warning System 2500 North Partnership Boulevard Designed, Engineered and Assembled in U.S.A. Springfield, Missouri 6580-8877 LT-0708.05 207, Inc. 744