Sentry 4 Zone Alarm Panel User Manual

Similar documents
CHEAT SHEET: SPECTRA V2.1

IDS816 User Manual H Issued January 2009

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

User s Information Guide R2A

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

SPECTRA 1728, 1738 CHEAT SHEET:

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

EVO192 v3.0 Fire and Burglary What s New

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Installation & Programming Guide

Watchguard WGAP864 User Manual

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Contents. Glossary

LS800S Intruder Alarm System. Engineering Manual

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Condominium Security Management System

SMS8 Alarm Control Panel

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

ITI Caretaker Basic Commands

AXI LED USER MANUAL (REV. 1.0)

Control/Communicator Installation Manual

Solution 862 Installation Manual ISSUE 1.30

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

TABLE OF CONTENTS TABLE OF CONTENTS 1


**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

HILLS Series LED Code Pad User Manual

Property of Monitronics Inc

3 User s settings. 3.3 Internal clock setting

DSC PowerSeries NEO Quick Start Guide

CC488. Quick Reference Guide Solution Ultima 880

Security System. User Guide for the LED Command Center

PROGRAMMING PROCEDURES (Table 3)

VISTA-50P VISTA-50PUL

JA-63 Profi User manual

L900 series USER MANUAL

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

CC408. Quick Reference Guide Solution 880

Wireless Keypads LKP(E)S8M Series

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

Tomorrow s technology for today s security needs.

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Solution 844 Operators Manual ISSUE 1.10

Power Wave Zone Alarm Panel V8.5. Installation Manual

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Security System. User s Guide for the Text Command Center

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Solution Ultima 862 Operators Manual ISSUE 1.10

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

For silent arm / disarm use BUTTON 2.

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

Wireless Keypad GKP-S8M

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

Installation Manual Premier 412/816/832. Issue 10

HARDWIRED CONTROL PANELS

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

QUICK USER GUIDE. Alarm Control Panel

System Introduction. 1.1 Specifications

LCD and 16-Zone LED Keypads. User s Manual

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

D3D Wi-Fi GSM Smart Alarm System -User Manual

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

"Pegaso" wireless alarm system

Version 1.03 January-2002 USER S MANUAL

The Icon Series. User Guide. CDV25 Version 1.0. Iconopm1.pm

Digiplex Control Panel (DGP-848) - V4.0

Property of Monitronics Inc

636 and 646 Keypads. User s Manual

Shed Alarm Kit. User Manual

ELT-KLED EliteSuite LED Keypad Installation Manual

NESS D8 CONTROL PANEL AND DIALLER

User's MANUAL A$ Rev 1.4

Program version Alarm Control Panel USER MANUAL GDAŃSK. versa_u_en 03/09

Series. NX-4-EUR Control Panel. Installation manual

Premium 8 Zone Wireless Alarm Kit

Total Protection Alarm System

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

Comfort Applications Manual

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

Scantronic Leading the way in security

CPVan Home Alarm Starter Kit

Digiplex LED Keypads User s Manual

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

"Pegaso" wireless alarm system D.I.Y. wireless kit

Transcription:

TM TM Sentry 4 Zone Alarm Panel User Manual PLEASE NOTE: A 16Vac / 16VA Transformer MUST be used with this product.

Contents 1. Introduction. 2. Programming a Remote. 3. Deleting all Remote s. 4. The siren function. 5. The strobe function. 6. The Key Switch. 7 Arming and Disarming the system. 8. Connection passives to the system. 9. Battery low indications. 10. How the zones work. 11. The Panic function. 12. The Output Triggers. 13. Bypassing a zone. 14. The Chime Function. 15. 16. 17. 18. Remote Functions. Instant Home arming Function. Zone Information. Appendix A. 19. Technical Information. POWERED BY 1

Introduction Congratulations on your purchase! The Sentry 4 zone alarm panel is a microprocessor based product that provides 4 hardwired zones as well as a remote panic and 2 output triggers that can be used for armed response purposes. It is a compact low cost system that is easy to use and provides peace of mind. The system consists of a build in receiver module that makes installation and operation easier. The system is controlled from a 4 button remote. Programming a Remote The system can handle a maximum of 15 remote s. Zones 1 to 4 represents the remote location in a binary format as follows: Zone Led s Remote Memory Location Memory Location 1 Memory Location 2 Memory Location 3 Memory Location 4 Memory Location 5 Memory Location 6 Memory Location 7 Memory Location 8 Memory Location 9 Memory Location 10 Memory Location 11 Memory Location 12 Memory Location 13 Memory Location 14 Memory Location 15 2

To start with the programming sequence: Open the Alarm panel Box. Press and release the LRN button on the PCB located in the box. The system will beep once, and will enter the first memory location. When the memory location is filled the led will flash and when the memory location is open the corresponding led will be ON solid. To advance to the next memory location press and release the LRN button again. The memory location is indicated via the led s on the front of the box. Press the remote button to be learned in. The green led (Bypass) will flash and the system will exit programming mode on acceptance of the code. Any button can be used to program the remote into the system. The system automatically assigns the functions to the remote buttons. A new remote can be learned into a filled location, keeping in mind that the old remote will be lost. The remote buttons have the following functions: Button 1 - Instant Arm System Button 2 - Instant Disarm System / Clear Panic Button 3 - Zone bypass Button 4 - Panic (~3Sec) Deleting all Remote s To delete all the remote s in the system, the following sequence must be followed: Open the alarm box. Press and hold in the LRN button on the PCB located in the box. After approx 5 sec the system will sound three short beeps indicating that the remote s has been removed from the system. The siren function: The siren is used to indicate a zone violation or a panic. When a violation occurs the siren will be activated for approx 2min, then it will turn off. The system will still be armed and any zone violation will activate the siren again. The siren is also used to indicate when the system is armed and disarmed. When the system is armed the siren hoots once and when the system is disarmed it hoots twice. The strobe function: When the system is armed and a violation has occurred the strobe function will be activated and it will remain active until the system is deactivated. The Key Switch: The option of a key switch is provided by adding a 1K resistor in series with the keyswitch onto zone 4. This will enable you to arm and disarm the system, When arming the system via the key switch, the exit timer will start beeping for approx 30 sec, where by the system will be fully armed. 3

Arming and disarming the system: To arm the system press button 2 on the remote. It is instant arming of the system and any violation will sound an alarm. Thus, make sure that the premises is evacuated before the system is armed. To deactivate the system, press button 2 on the remote. Premises can now be entered. Connecting detectors to the system: To Connect a PIR or door contact to the alarm panel, a 2K2 resistor (provided) must be connected in series with the device. PIR T T N/C N/C -+ 2K2 ZONES 1-2 +- +12V If the zone is not in use, connect the resistor to the terminals as shown below. 2K2 2K2 ZONES 1-2 Battery low indications: When the mains is disconnected from the system, the AC led will be OFF and the system will monitor the battery. When the battery voltage reaches 11.5V the AC led will start to flash, indicating that the battery level has dropped from full charge. At 10.8V the AC led will still flash and the system will now beep, indicating that The battery is low. When mains is connected the AC led will be ON. 4

How the zones work: A form of detection device is connected on a zone and is monitored by the system. This can be an infra red detector or a door contact. When a zone is not bypassed and the system is armed, any violation of that zone will activate an alarm. The zones have the following functions: Zone 1 - Timed Entry / Exit zone Zone 2 - Follower Zone Zone 3 - Instant Zone Zone 3 - Instant Zone A 2k2 resistor provided with the system needs to be placed in series with the Passive infra red detector or the door contact. (The resistor must be placed close to the detector as possible) Note: Output trigger 2 is by default assigned to a burglary condition. The Panic Function: The hardwired panic is a normally closed connection (See Appendix A for connection). If not connected properly the system will sound an alarm when the system is start-up for the first time. To deactivate the hardwired panic or the remote panic, press the arm disarm button on the remote. Note: Output Trigger 1 is by default assigned to the panic condition. The output Triggers: The system has 3 output triggers. They can be used as positive (+5V) or negative polarity by making use of the links provided. There functions are as follows: Output 1 - Panic Output 2 - Burglary Output 3 - LED Status Indicator POSITIVE TRIGGER NEGATIVE TRIGGER LINK CONNECTION FOR POSITIVE AND NEGATIVE TRIGGER. Bypassing a Zone: Bypassing a zone enables that zone to be omitted from the system, thus free to use that room without triggering an alarm. To bypass a zone the following sequence must be followed: Press Button 3 on the remote, the green (bypass) led will start flashing. The system provides a time of approx 15 sec to do bypassing, where by it will exit from the bypassing function. The 4 buttons on the remote represents the 4 zones. Pressing the button corresponding to the zone once will bypass that zone and the zone led will be ON solid. By pressing the same button again will undo the bypassing on that zone. Make the selection of zone to bypass. The bypass function will then exit after approx 15 sec and the system will return to normal operation. The zone that are bypassed will then be displayed. Press the arm / disarm button to arm the system. The zones are cleared upon arming of the system. 5

The Chime Function: From time to time the need arises to know when a zone is triggered without setting off an alarm. To enable the chime function press Button 1 and 2 together once. The system will beep and the green bypass led will start flashing. When a zone is triggered a zone, a pulsed beep will be heard for the duration the zone is triggered. To disable the function press button 1 and 2 together again, the system will beep again, and the green led will turn off. The user can go directly from chime function to away arm, by pressing button 1. The green led will turn off and the away arm led will be on. Remote Functions: The Remote is used to control most of the system functions. The Remote buttons have the following functions: Button 1 - Instant Arm Button 2 - Instant Disarm Button 3 - Zone bypass Button 4 - Panic Button 1 and Button 2 - Enable/Disable Chime Function Instant Home arming function: When using the Home arming function, the system enters instant arm mode with zones 2 and 3 bypassed. The green led(bypass) will be ON. To enter Instant Home arming mode press buttons 3 and 4. Zones led 3 and 4 will flash briefly to indicate with zones was bypassed. Zone Information: Enter Zone names for a reference. Zone 1 Zone 2 Zone 3 Zone 4 6

Technical Information: AC Input Voltage: Battery Backup: Remote Freq: Remote Type: Remote Control Storage: ~16VAC/16VA Transformer (Earth from the panel must be connected to mains earth) 12V/7Ah 433.925Mhz Keeloq 15 Remotes SWITCH SIREN AC APPENDIX A 7