Original instructions. Panther 6-15 kw

Similar documents
Fan heater Panther Powerful fan heater for large premises

Original instructions AR

Fan heater Panther WALL MOUNTED FAN HEATER

Original instructions. Infrared heater IRCF...17

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

Original instructions. Thermoplus

Fan heater Panther 6-15 Efficient fan heater for medium size premises

IHC

Original instructions. Thermoplus PL RU

AC25. Art.nr:

Elektra F GB NO FR

Original instructions SWX C/D NO DE ES... 26

Fan heater SWT Ceiling mounted fan heater with water heat

Original instructions. SIRe Basic Quick guide. SIReB

Industrial infrared heater IR For premises with large volumes and high ceilings

Thermozone AC 300/WAC 300

Original instructions PA

SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see p Original instructions

Industrial infrared heater IR

Thermozone ADR 200/300 E/W

Thermostats. Type Voltage Max. current Setting range Protection class HxWxD breakpoint [V] [A] [ C] [mm] RTEV C IP30 71x71x28

Original instructions PAECS NO DE ES

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

Thermozone AD Corinte

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Original instructions PAEC3200 NO DE ES

Thermozone SF. Air curtains for vertical mounting in curved doorways

HS&S Alert No: 103 Date: 9 March 2017

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Topvex SF02-SF12 Air Handling Unit

Original instructions PA2500

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

EH1688. Over Door Heater & Fan Chauffage de Porte & Ventilateur

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

EH kW Panel Heater

PH1000T PH1500T PH2000T

SWS SE GB NO DE ES FR IT NL PL RU... 49

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

IMPORTANT INSTRUCTIONS READ & SAVE

BlackRidge Sun Infrared Heater

Convection Panel Heater

IMPORTANT INSTRUCTIONS READ & SAVE

Original instructions AGI4500/6000

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Elztrip EZ100 Single panel radiant heater for offices, shops etc.

Original instructions PA2200C NO DE ES... 47

200W Frostwatch Radiant Heater Operation Manual

HEAT RECOVERY AIR HANDLING UNIT

Installation manual Washer extractor

Radiant Heater. Instruction Manual QH-200 N13275

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Your model: Your service centre: Operating Instructions for deep fat fryers

Elztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications

Topvex SR 09, 11, Topvex TR Compact Air Handling Units


Original instructions AR

AC500T, AC1000T, AC1500T, AC2000T

Turbo. Service Instructions

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

CG60/ 70/ 80/ 90/ 100 SS/BK

EH W Pressure Washer

INSTRUCTIONS FOR CARBON INFRARED HEATER

USER S MANUAL. VKP Series INLINE FAN

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Lo-Carbon T-series Window & Roof Models

Installation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Imperial Electric Fires

IMPORTANT INSTRUCTIONS READ & SAVE

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

EH0533 Indoor Climate Control

Operating and assembly manual: Electric instantaneous flow heater Admiral

Original instructions SFS

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

ART cm Island Curved Glass

INSTALLATION AND OPERATION MANUAL

Thermocassette HP RADIANT HEAT CASSETTES FOR CEILING MOUNTING

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

AIR CURTAIN HX RECESSED RANGE

Grohtherm Wireless! Installation Instructions Pumped

EH0554 Indoor Climate Control

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

5KW ELECTRIC FAN HEATER

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Built-in Electric Ceramic Hob

Light oil - kerosene burner

HD3D Forced-Air Heater

AIR CURTAIN T SURFACE MOUNTED RANGE

Panel Heater Slim 1.5kw MODEL: NDK15-12K

Radiant heaters - Offices, shops and public premises

Transcription:

Original instructions 6-15 kw SE... 8 GB... 10 NL... 12 IT... 14 ES... 16 FI... 18 DE... 20 FR... 22 NO... 24 RU... 26 PL... 28

6/15 Fig 1. Bracket 100 ø7 520 90 ø6,5 ø14 450 510 Fig 2. Ceiling Wall 30 min 300 min 300 Wall min 1000 7,5 Mixing cabinet (accessory) B C 15 A min 1800 D G E F A B C D E F G [mm] [mm] [mm] [mm] [mm] [mm] [mm] 660 430 365 420 445 445 420 2

CBT 2 1 1h 4h 2h 6/15 Controls and accessories RTI2 KRT2800 PTA01 PSA01 Type E-nr HxBxD [mm] RTI2 85 811 44 155x87x43 KRT2800 85 810 44 165x60x57 87 112 28 160x120x96 PTA01 87 112 31 215x185x115 PBS01 87 112 32 660x430x365 PHR01 87 112 37 PSA01 87 112 35 215x305x115 PSM01 87 112 38 180x100x70 PLR15 87 112 39 355x355x60 PFF15 87 112 44 PTRP 87 112 00 PBS01 KRT1900 TTF140 CBT Drying room kit PTRP. 3

SE 06, -09, -12, -15 400V 3N~ / 230V 3~ 6/15 SE06-15 230V ºC L 1 L 2 L 3 L 1 L 2 L 3 440V 500V L 1 L 2 L 3 K1 K2 440V 3~ 500V 3~ M K1 K2 kw SE 06 ºC L 1 L 2 L 3 L 1 L 2 L 3 L 1 L 2 L 3 N 12345678910111213141516 K1 K2 400V 3N~ 12345678910 kw kw SE 09-15 1 2 3 4 a bcd 2 3 b c K1 400V3~ K2 X X X X X X 1234 X X X ½ 1 12 1 ½ Factory setting 1 2 3 9 1112 1415 L 1 L 2 L 3 N 230V3~ K1 K2 Sensor 230V~ L N 230V3~ 230V3~ 1 2 3 4 5 6 7 L L N >t C Hi >t C Lo 230V~ RTI2 1 2 3 1 2 3-1 -4 C KRT 2800 C 4

6/15 1 Note! Remove the two internal fuses 6.3A in the slave unit(s). SE06-15 1 2 3 4 5 6 7 8 9 10111213141516 7 SE06-15 High speed 1 2 3 4 5 6 7 8 9 10111213141516 SE06-15 1 2 3 4 5 6 7 8 9 10111213141516 Medium speed SE06-15 1 2 3 4 5 6 7 8 9 10111213141516 Low speed 2 Note! Remove the two internal fuses 6.3A in the slave unit(s). SE06-15 1 2 3 4 5 6 7 8 9 10111213141516 7 SE06-15 1 2 3 4 5 6 7 8 9 10111213141516 8+ 1 2 3 4 5 6 7 8 9 10 5

6/15 3 Note! Remove the two internal fuses 6.3A in the slave unit(s). SE06-15 1 2 3 4 5 6 7 8 9 10111213141516 7 SE06-15 1 2 3 4 5 6 7 8 9 10111213141516 8+ 6+ 1 2 3 4 5 6 7 8 9 10 RTI2 RTI2 1 2 3 4 5 6 7 L N 4 Note! Remove the two internal fuses 6.3A in the slave unit(s). SE06-15 1 2 3 4 5 6 7 8 9 10 11121314 1516 7 SE06-15 1 2 3 4 5 6 7 8 9 10 11121314 1516 7+ 1 2 3 4 5 6 7 8 910 4+ KRT 2800 KRT2800 1 2 3 1 2 3 6

6/15 Technical specifications Fan Heater 6-15 kw 3 Typ E-nr Effektsteg Luftflöde Ljudnivå* 1 t* 2 Spänning Ström HxBxD Vikt [kw] [m³/h] [db(a)] [ C] [V] [A] [mm] [kg] SE06 87 112 50 0/3/6 900/1300 39/47 20/14 400V3N~ 8,7 520x450x510 21 SE09 87 112 51 0/4,5/9 900/1300 39/47 30/21 400V3N~ 13,0 520x450x510 22 SE12 87 112 52 0/6/12 900/1300 39/47 40/28 400V3N~ 17,3 520x450x510 22 SE15 87 112 53 0/7,5/15 900/1300 39/47 50/35 400V3N~ 21,7 520x450x510 22 SE135 87 112 36 0/5/10 0/7/13,5 Protection class: IP44. CE compliant. 900/1300 39/47 34/23 45/31 440V3~* 3 500V3~ * 1 ) Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent absorption area: 200 m 2. * 2 ) t = temperature rise of passing air at maximum heat output at lowest/highest airflow. *³) Can be connected to 440V3~ and 500V3~. 13,4 15,6 520x450x510 23 7

GB 6/15 General Instructions Read these instructions carefully before installation and use. Keep this manual for future reference. The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid if the product is used in the manner intended and in accordance with the instructions. Application area 6-15 is a range of very quiet and efficient fan heaters for stationary use. They are intended for heating, drying and ventilation in e.g. workshops, sport halls, shops, assembly rooms and drying rooms. The mixing cabinet (accessory) allows heating and ventilation to be combined, through mixing the return air and outdoor air. Protection class: IP44 Function The air is carried through the heater by a fan and heated by non-corrosive elements which are regulated by the built-in thermostat with a range of +5 - +35 C. The air speed is adjustable in three steps. Switching on or off, selecting half or full output and regulating the RPM is performed through the control panel (ordered separately) which is wall mounted for easy access. The appliance is protected from overheating via a built-in temperature limiter. To reset, see Overheating.The heater is mounted on a wall with a bracket, which allows direction of the air stream in several directions, straight ahead, to the left, to the right and down. Installation The fan heaters are intended for wall mounting. The appliance must not be placed directly under a wall-outlet. N.B.! The minimum distances given in fig. 2 and 3 must be kept. The fan heaters must not be mounted on the ceiling. Loose the bracket from the appliance by unscrewing the bolts. Mark holes by means of the loose bracket. Assembly and operating instructions Drill holes for the fixing plugs. Mount the bracket. Mount the fan heater on the bracket and adjust the heater to desired vertical and horizontal angles. Screw the bottom bolt in and tighten all bolts. Installation with mixing cabinet Mixing cabinet PBS is available as an accessory and consists of an outer wall grille and a walling-in frame. The walling-in frame and outer wall grille are built or screwed to the wall. The mixing cabinet and the unit are then fitted. See diagram 2. The hand controller (PHR01, accessory) consists of a lever, a wall bracket, a control ball and two associated joints. A pull-rod is used between the joints (not included). Electrical installation The electrical installation should be carried out by a qualified electrician in conformity with prevailing regulations. The appliance should be preceded by an all-pole switch with at least 3 mm breaking gap. There are several ways to connect depending on the desired function. On delivery the appliance is equipped with connections on the terminal block. With a connection between terminals 14 and 15, the fan RPM will be controlled by the regulation and the heat by the thermostat. Without the connection the thermostat will control both fan RPM and heat. When accessories are connected or when several heaters are connected to each other and controlled by a common accessory. Between terminals 1 and 13, a 230V~ alarm signal can be obtained. When the temperature limiter is triggered, the voltage will drop to zero. On delivery the 6 15 fan heaters are for 400V 3N~. SE135 can be connected to both 440V3~ and 500V3~. 10

6/15 GB The heaters can be reconnected to 230V3~ according to fig. 4. The connection should be made with a cable type S05VV-U, A05VV-R or similar. For control H05VV5-F0,75 mm² or similar may be used. Type Output [kw] Voltage [V] Min.area [mm 2 ] All control 230V~ 0,75 SE 06 6 400V 3N~/230V 3~ 1,5/2,5 SE 09 9 400V 3N~/230V 3~ 2,5/6 SE 12 12 400V 3N~/230V 3~ 4/10 SE 15 15 400V 3N~/230V 3~ 6/16 SE 135 13,5 500V 3~/440V 3~ 4/2,5 On the back of the appliance there are knockouts. Cable-glands used must guarantee the protection class requirements! When several heaters are connected to each other and controlled by a common accessory it should be stated in the group centre that The fan heaters are fed from more than one group supply. Start-up (E) When the unit is used for the first time or after a long period of disuse, smoke or odour may result from dust or dirt that has collected on the element. This is completely normal and disappears after a short time. Overheating If the temperature limiter has been triggered due to overheating, reset as follows: Disconnect the electricity with the all-pole switch. Investigate the matter and repair the fault. Reset by opening the lid and pushing the red button on top of the temperature limiter until a click sound is heard. Put on the lid and reconnect the heater. Maintenance The motor and other components are maintenance-free. Dust and dirt may cause overheating and danger of fire. The appliance must therefore be cleaned regularly. Residual current circuit breaker (E) When the installation is protected by means of a residual current circuit breaker, which trips when the appliance is connected, this may be due to moisture in the heating element. When an appliance containing a heater element has not been used for a long period or stored in a damp environment, moisture can enter the element. This should not be seen as a fault, but is simply rectified by connecting the appliance to the mains supply via a socket without a safety cut-out, so that the moisture can be eliminated from the element. The drying time can vary from a few hours to a few days. As a preventive measure, the unit should occasionally be run for a short time when it is not being used for extended periods of time. Safety For all installations of electrically heated products should a residual current circuit breaker 300 ma for fire protection be used. Ensure that the area around the intake and exhaust grille is kept free from material which could prevent the air flow through the appliance. The appliance has hot surfaces during operation! The appliance must not be covered either with clothes or similar material since overheating of the appliance can result in a fire hazard. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 11

Main office Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se Art.no 201398, 2013-05-30 HH/ SÄ