WATER HEATER FOR POOL & SPA

Similar documents
WATER HEATER FOR POOL & SPA

WATER HEATER FOR POOL & SPA

Owner s Manual for Swimming Pool Heat Pump

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

SWIMMING POOL & SPA HEAT PUMPS INSTALLATION MANUAL

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Next Generation Corona Discharge Installation & Operation Manual

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

DRAIN WATER TEMPERING INSTALL

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

Closing procedures for above-ground pools

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

MACH N-407 Heat Pump Air-Cooled Chiller

Owner s Manual PRINTED IN CANADA 05/2009

PZ1, PZ3 & PZ6 Installation Guide

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

SERIES THREE 480 VOLT 3 PHASE DELTA ELECTRIC INSTANTANEOUS WATER HEATER

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

AS-H40Y - 12KW AS-H50Y - 15KW AS-H60Y - 18KW. ALTOHeat Pump installation manual

Quick Start Guide. For product manuals and further installation / operation procedures visit

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

Removing shipping locks

EEMAX ProAdvantage Series 1

INSTALLATION, OPERATION AND MAINTENANCE

MAC N-407 Air-Cooled Chiller

Owner s Manual & Installation Guide. Model 525S Model 525TI Model 650TI Model 650SC Model 700TI

Ozone Generator Systems

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

CHILLER. Model CH3000. Operator s & Installation Manual

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

Q&A 2016 Practical Guide

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

EEMAX PROADVANTAGE ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL

»»»»»»»»»» Utility pump LAUNDRY TUB PUMPING SYSTEM. CAPACITY: 1400 US GPH HEAD OF: 10 (3m)

MIRAGE EVO 250 PEDICURE SYSTEM

Heat Pumps. English. Models: M1, M2, M3, M4, M5. User Manual

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

CHAMPION PUMP OWNER S MANUAL

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Flow Factor ~

OWNER S Manual PRINTED IN CANADA 10/2009

MAC-120HE-03 Air-Cooled Chiller

J-PRO V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide

TABLE 1 Electrical Specifications. Phase

Ozone Generator Systems

SWIMMING POOL HEAT PUMP

Installation Instructions & Operating Manual

Low kw Electric Tankless Water Heater Troubleshooting Guide

HP50HA ABG Heat Pump

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

SMF PUMP OWNER S MANUAL

Panel Fan Series Operators Manual (Galvanized and Polymer)

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

EEMAX THREE MODULE, SINGLE PHASE WATER HEATERS

OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

Information Manual Rev 12.16F Installation and

TORRID MARINE YACHT QUALITY Since Owner s Manual

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Installation Manual PPT8/12/16/22LX/LY SLIMLINE

L A signature series TA T N E RE O, A L L A T S IN

WAIWELA SERIES-TWO WATER HEATERS

EXTREME HC-4 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT Tel:

1020 Industrial Drive, Orlinda, TN fax

EXTREME HC-8 Reverse Osmosis System

IMPORTANT SAFETY INFORMATION READ ALL...

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

Sanitary Water Tank INSTALLATION & SVC MANUAL

Installation and Operation Guide

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Section 1. Information before installation

OPERATION & INSTALLATION MANUAL

PRO SERIES IMPORTANT SAFETY INFORMATION

Service Handbook. Servicing should only be performed by a Qualified Service Agent.

EEMAX HOME ADVANTAGE

THERMOTEC INVERTER SWIMMING POOL HEAT PUMP

Dishwasher Installation Manual

#300 & #302 CHLORINEIBROMINE FEEDERS

INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

Installation & Service Guide

G&F Manufacturing Service Manual Version 2.0 April 2010

Owner s Manual Therma-Stor II Heat Recovery System

State problem and/or comments:

TABLE 1 Electrical Specifications

Transcription:

WATER HEATER FOR POOL & SPA GENERAL CHARACTERISTICS MODÈL B The PVC tank provides sturdiness Contains two thermals circuit breaker and one pressure Switch Available power : 6 to 72 kw. Models are available for both interior or exterior pools and hot tubs. ETL approved 25 years on PVC tank only, 2 years warranty against manufacturing all fabrication defect any manufactured defect, water-heater should be return afterwards with our authorization without any carrying fees of transportation however, disconnection or else won't be on Val Therm responsibility. **We have no guarantee on element any time *Made in Canada www.valtherm.ca Tel : (514) 262-5010 Fax : (450) 735-0935 info@valtherm.ca

HOW TO DERTERMINIE THE RIGHT POWER RATING OF YOUR VAL THERM POOL HEATER The following factors will influence the power needed for your pool heater: Pool dimension, average depth, wind exposure, period of utilization, ground composition, weather, etc... With normal weather conditions as in our regions, we will be able to determine the power needed for your pool heater, based on empirical method or mathematical formulas. EMPIRICAL METHOD Our experience shows that according to your utilization period, the power for your Heater should be as follow: 4 months utilization: 1.0 kw per 4500 litres (1000 imperial gallons) 5 months utilization: 1.5 kw per 4500 litres (1000 imperial gallons) 6 months utilization: 2.5 kw per 4500 litres (1000 imperial gallons) 4500 liters = 1000 imperial gallons

MATHEMATICAL METHOD You can determine your heater power and also weather elevation rate for a given heater by applying this formula: How to establish the heater power: Power (KW) = K (W/ Cft²) X temp.diff. ( C) X surfpool. (pi²) 1000 (W/KW) K: Conversion constant: 5.715 W/ ft² Temp. Diff.: Temperature spread between water surface and ambient air. Normal use is generally between 5 C and 8 C. K: How to determine temperature elevation rate: Elevation ( C/hour) = K ( Cft³/KWH) X Power (KW) Surf.pool (ft²) X av.depth (ft)

PHYSICAL DIAGRAM 7 2 9 3 6 1 8 10 11 23 inches in height 5 20 inches 4 18 12 15 16 17 14 12 inches in height TITANIUM ELEMENTS OPTION FOR SALT WATER SYSTEMS

Component List 1-WATER TANK PVC Water tank 2-WATER INLET Female threaded socket of 1½ N.P.T. 3-WATER OUTLET Female threaded socket of 1½ N.P.T. 4-DRAINING PLUG Female threaded socket of 1 N.P.T. 5- ELECTRONIC THERMOSTAT Adjustable for Pool or Spa 6-TERMINAL BLOCK Terminal block for electricity supply 7-STATIC CONTACTOR Allow the activation of the heating elements. Contactors are engage through the thermostat. 8- TRANFORMER CONTROL Only used for the 600 volts Water-heater. Allows supply the solenoid contactor. 9-TIME CONSTANT Allows a sequential activation of the heating elements (Water-heater with 208 and 240 volts with 21kw of power or more).

10- BRAKER Component List Protects the control circuit against electric overloads. (600 volts and 208 volts Water-heater only) 11-GROUND BOX Make sure that the ground box is in the ground to prevent any electrocution. 12-THERMAL PROBE When water is inferior of the temperature assign, it allows the activation of the elements though the thermostat. 13-HEATING ELEMENT Triple phased 600 volts element, with a power 6 or 9 kw. 14- HEATING ELEMENT Single phased 240 volt element, with 3kw power. 15-OPENING 1½`` diameter opening allowing the passage of alimentation cables. 16-THERMAL PROTECTION High temperature circuit breaker with automatic reengagement. 17-TERMAL PROTECTION High temperature circuit breaker with manual reengagement. 18-PRESSURE SWITCH A cut-off switch when water is low.

TROUBLESHOOTING If water stays cold and pilot light is off: 1- Check the voltage 2- Check circuit breaker, main fuses and replace if necessary 3- Check the High Temperature Cut off Switch with Manual Reset (refer to the physical diagram). 4- Check thermostat. 5- For the 600 volts water-heater, checks the circuit breaker located in inside the control box and if necessary, replace it. If water does not heat as wanted and pilot light is on: 1- Check voltage 2- Check thermostat 3- Check heating elements. You should obtain the following readings in regards of elements type: TYPE Electrical characteristic of Heating Elements Power (KW) Voltage L-L (V) Line current (A) Resistance (Element disconnnected) 240v-1ph 3,0 240 12,5 19,0 208v-1ph 3,0 208 8,3 14,4 600v-3ph 6,0 600 5,8 5,7 600v-3ph 9,0 600 8,7 8,6

INSTATALLATION - LOCATION SITE This Val Therm water heater can be installed either inside or outside. We strongly recommend sheltered from rain. It is important that all safety and installation standards be respected. The water heater must be positioned vertically and at the filter end. A free space of 12 all around the heater must be accessible for maintenance. ELECTRICITY The electrical wirings must be performed by qualified electrician. PLUMBING The inlet and outlet of the pool heater are connected to two 1 ½ N.P.T. threaded cap is included with all models for emptying convenience. Note: Use only Teflon tape to assure water tightness of pipes connections. Tight pipes properly, and use tools when necessary, ex: Pipe wrench.

ELECTRICITY The electrical wirings must be performed by qualified electrician.

PLUMBING SKETCH FOR THE WATER HEATER MODEL A OPENED VALVE OPENED VALVE Water inlet Water outlet CLOSED VALVE It is recommended to install a by-pass on the plumbing of the water heater. BY-PASS CLOSED VALVE CLOSED VALVE Water inlet Water outlet OPENED VALVE It is recommended to isolate your water heater on the water by-pass when you do your shock treatment at the opening of your pool not to damage the component.

STAR UP 1- Before switching on pool heater, activate the pump of the filter and ensure that no air remains inside the water heater. This can be checked when no more bubbles appear at the pool when water recycles back to the surface. 2- Adjust the thermostat to the desired temperature level. The time to reach the desired temperature varies, depending on initial temperature of the water, weather conditions, etc... 3- For security, two reset buttons protect the machine against high temperature elevation 120 C, the reset button shot off automatically the circuit, so you have to restart by pushing the red button. The third security, It s a pressure switch for the lower water pressure in the water thank. This unit require a minimum flow of 35 gallons per minute. 4- Maintain proper water chemical balance: ph level: 7.4, alkalinity: 120, salinity: 180-260, otherwise internal parts may deteriorate prematurely, those damages are bit covered by the warranty. Do not send water through the water heater until it is balanced (see bypass diagram) Test the water and balance it every week. 5- Tank should be full of water before starting up, otherwise permanent damage to parts occurs. Such damage is not covered by the warranty. WINTERIZING Empty heater tank draining plug to prevent water freezing inside tank during winter. SAFETY Before opening the pool heater, make sure it is not plugged in. This unit require a minimum flow of 35 gallons per minute. Part replacement with original only Do not install two heaters on the same line because it could lower the water pressure and cause damage. If you install a timer on the pump and/or the filter, there needs to be a 240 volts timer on the water heater do that this one shuts down 30 minutes before the one on the pump and/or filter

POOL HEATER WATER LIST 240 VOLTS 1 PHASE Puissance Line current BTU/ hour # model 6 kw 25,0 A 20 427 A1P2-6 9 kw 37,5 A 30 708 A1P2-9 12 kw 50,0 A 40 944 A1P2-12 15 kw 62,5 A 51 180 A1P2-15 18 kw 75,0 A 61 416 A1P2-18 21 kw 87,5 A 71 652 A1P2-21 24 kw 100,0 A 81 888 A1P2-24 27 kw 112,5 A 92 124 A1P2-27 30 kw 125,0 A 102 360 A1P2-30 33 kw 137,5 A 112 596 A1P2-33 36 kw 150,0 A 122 832 A1P2-36 39 kw 162,0 A 133 068 A1P2-39 42 kw 175,0 A 143 304 A1P2-42 45 kw 187,5 A 153 540 A1P2-45 208 VOLTS 3 PHASES Puissance Line current BTU/ hour # model 9 kw 25,0 A 30 708 A3P3-9 15 kw 50,0 A 51 180 A3P3-15 18 kw 50,0 A 61 416 A3P3-18 24 kw 75,0 A 81 888 A3P3-24 27 kw 75,0 A 92 124 A3P3-27 33 kw 100,0 A 112 596 A3P3-33 36 kw 100,0 A 122 832 A3P3-36 600 VOLTS 3 PHASES Puissance Line current BTU/ hour # model 9 kw 8,7 A 30 708 A3P3-9 12 kw 11,5 A 40 944 A3P3-12 15 kw 14,4 A 51 180 A3P3-15 18 kw 17,3 A 61 416 A3P3-18 21 kw 20,2 A 71 652 A3P3-21 24 kw 23,1 A 81 888 A3P3-24 27 kw 26,0 A 92 124 A3P3-27 30 kw 28,9 A 102 360 A3P3-30 36 kw 34,6 A 122 832 A3P3-36 45 kw 43,3 A 153 540 A3P3-45 Other models available on demande. // Model number : P= pool T=tourbillion Current mesured at the nominal tension. // Voltage:1= 240 V, 3=208V & 600V

WARRANTY 25 years on PVC tank only, 2 years warranty against manufacturing all fabrication defect any manufactured defect, water-heater should be return afterwards with our authorization without any carrying fees of transportation however, disconnection or else won't be on Val Therm responsibility. **We have no guarantee on element any time CUSTOMER NAME: ADDRESS: DEALER NAME : Water heater: Pool ( ) SPA ( ) Capacity (kw) : Model: Serial number: IMPORTANT: Warranty is void if the following conditions are not met: Before starting up, tank must be filled or water. Otherwise, permanent damage may occur to parts. Maintain proper water chemical balance: ph level: 7.4, alkalinity: 120, salinity: 180-260. Otherwise internal parts may deteriorate prematurely. Test the water and balance it every week. For pools or spas with salt machine: do not go ever 3200 PPM, TITANIUM ELEMENTS OPTION FOR SALT SYSTEMS Do not put chlorine tablets in the skimmer. Do not send water through the water heater until it is balanced (see bypass diagram). If you install a timer on the pump and/or the filter, there needs to be a 240 volts timer on the water heater do that this one shuts down 30 minutes before the one on the pump and/or filter.