ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

Similar documents
ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E)

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

STEP 1: SELECT A NITROGEN GENERATOR STEP 2: SELECT A VENT STEP 3: SELECT MONITORING EQUIPMENT STEP 4: CONTACT ECS

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

Comprehensive corrosion solutions backed by over 115 years of fire sprinkler monitoring. POTTER CORROSION SOLUTIONS

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

TECHNICAL DATA OBSOLETE

TotalPac X Single interlock SUREFIRE system

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

TotalPac X Firecycle III Preaction Double interlock system

VSA Series Air Dryer. User s Guide

White Paper. Monitoring Corrosion in Water Based Fire Sprinkler Systems (July 2013) By Jeffrey Kochelek V.1.0.0

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

FM-200 In-Cabinet Series

POTTER CORROSION SOLUTIONS

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

Worldwide Contacts.

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL. franklinwater.com

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Corrosion in Fire Sprinkler Systems Increasing Your Liability, Increasing Your Costs, and Shortening System Life

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Heatless Desiccant Compressed Air Dryers

FireFlex DUAL Double Interlock, Self-contained system

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TECHNICAL DATA. 319a. January 27, 2012

TECHNICAL DATA OBSOLETE

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

TOTALPAC2 Integrated Fire Protection System

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

TECHNICAL DATA. model c-2

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Compressed Air Dryers

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)


MODEL MW200 MODEL MW600 AIR DRYER

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

PURest Air Dryer Installation and Maintenance

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

P4200PM / P5000PM Remote Air Dryer User s Guide

TCR. Features: TISSUE CULTURE

Waveguide Dehydrators

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Refrigerated Air Dryers

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

White Paper. Chemical Corrosion Inhibitors - Six Reasons Why They Should Not Be Used in Water Based Fire Sprinkler Systems (June 2011)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Product Catalogue Edition 1

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Corrosion Dry Air Pak

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

AGF Manufacturing Inc.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

TCC-34. Features: TISSUE CULTURE

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Viking Installation Guide

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual

INSTALLATION INSTRUCTIONS

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

SECTION AIR COMPRESSORS AND ACCESSORIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

HL Hydraulik GmbH SCHRUPP GAS DRYER STATIONS GAS DRYER STATIONS. Optional with Bypass.

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Transcription:

ECS Protector PGEN-40/PGEN-50/PGEN-60 (PGEN-40E/PGEN-50E/PGEN-60E) For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Specifications Dimensions (cabinet): Dimensions (incl. bypass): Weight: Power Supply: Power Consumption: Gas Connections: Drain Connection: FM Approved 24 (W) x 76 (H) x 12.5 (D) (610mm (W) x 1,930mm (H) x 318mm (D)) 33 (W) x 76 (H) x 12.5 (D) (838mm (W) x 1,930mm (H) x 318mm (D)) PGEN-40-264 lbs (120kg) PGEN-50/60-300 lbs (136kg) 120VAC/1 phase/60hz - Dedicated Circuit (230VAC/1 phase/50 Hz - Dedicated Circuit) 2 Amps Air Inlet - ½ NPT Female Nitrogen Outlet - ½ NPT Female ¼ NPT Female UL 508A Listed Industrial Control Panel Ordering Information Stock Number: Replacement Filters: Gas Membrane: General Description PGEN-40/PGEN-50/PGEN-60 (PGEN-40E/PGEN-50E/PGEN-60E) PGEN-40FK/PGEN-50FK/PGEN-60FK (annual maintenance) PGEN-40M/PGEN-50M/PGEN-60M (20 year expected service life) The ECS Protector is designed for use in maintaining supervisory gas and facilitating the Dry Pipe Nitrogen Inerting (DPNI) process for controlling oxygen corrosion in dry and pre-action fire sprinkler systems. The ECS Protector Nitrogen Generator can also be used for Wet Pipe Nitrogen Inerting (WPNI) in wet pipe sprinkler systems. The ECS Protector is an on-site nitrogen generation system that is designed to be installed inline between the compressed air supply and the sprinkler system riser in dry, preaction or wet pipe sprinkler systems. The nitrogen generator utilizes membrane gas separation technology that exhausts oxygen as a waste gas to produce 98%+ nitrogen on demand with no nitrogen storage necessary for dry or preaction systems. The ECS Protector cabinet has an external bypass valve to allow for nitrogen generator maintenance or fast fill needs, and is designed to meet the NFPA 13 30-minute fill requirement for dry pipe or preaction fire protection systems. ECS Protector PGEN-40(40E)/50(50E)/60(60E) 1

The ECS Protector facilitates the patented fill and purge breathing process in the fire sprinkler system when paired with a venting device installed on the sprinkler riser such as the ECS The ECS unit that includes the following components: Steel enclosure cabinet with membrane type nitrogen generator (no nitrogen gas storage) and manual bypass Power supply - 120VAC/1 phase/60hz (230VAC/1 phase/50hz) Single point nitrogen/air discharge ½ NPT Hour Run Meter Cycle Counter The ECS includes the following function Indications: Bypass Alarm - Nitrogen generator is in the By-Pass mode (Flashing Indicator) Leak Monitoring - Nitrogen generator running excessively (Audible Signal) Operating Performance Protector Manual Vent (PAV-D) or the ECS Protector Dry SMART Vent (PSV-D/DE) for dry and preaction systems; or ECS Protector Nitrogen Inerting Vent (PAV-WN/NS) for wet-pipe systems. The ECS includes the following monitoring outputs: System Power (Digital Output) Bypass Mode Alarm (Digital Output) Nitrogen Generation Mode (Digital Output) Nitrogen Supply Line Pressure (Analog Output) Leak Monitoring (Digital Output) The ECS is designed to be used in conjunction with the following components as part of the complete ECS Dry Pipe Nitrogen Inerting (DPNI) system: Air maintenance device with on board adjustable regulator (recommend Victaulic Series 757, Tyco Model AMD 1 or Reliable Model A-2) Riser-mounted ECS Protector Manual Vent (PAV-D) or ECS Protector Dry SMART Vent (PSV-D/DE) ECS Protector SMART Gas Analyzer (SGA-1/1E) one per nitrogen generator is recommended ECS In-Line Corrosion Detector (ILD-X) monitoring at least one system is recommended Model Number Min. Supply Air (SCFM) Total System Capacity (Gallons) Single System Capacity @ 40 psig (Gallons) Single System Capacity @ 20 psig (Gallons) PGEN-40 17 10,000 1,440 2,880 PGEN-50 24 18,500 2,025 4,050 PGEN-60 24 22,500 2,025 4,050 Model Number Min. Supply Air (L/min) Total System Capacity (Liters) Single System Capacity @ 2.8 bar (Liters) Single System Capacity @ 1.4 bar (Liters) PGEN-40E 489 37,854 5,451 10,902 PGEN-50E 688 70,030 7,666 15,331 PGEN-60E 688 85,172 7,666 15,331 ECS Protector PGEN-40(40E)/50(50E)/60(60E) 2

ECS Protector Capacity based on NFPA 13 30-minute fill requirement of largest single system Capacity based on using 5hp air compressor provided by ECS Capacity based on using 7.5hp air compressor provided by ECS Nitrogen Quality N2 Purity at Discharge: N2 Pressure at Discharge: N2 Water Dew Point: 98% or greater (maximum of 2.0% oxygen) Min of 15 psig (1 bar); Max of feed air pressure minus 15 psig (1 Bar) Typically less than 70ºF ( 57ºC) Note: When connecting an ECS Protector to an existing dry pipe/preaction fire sprinkler system, the existing fire sprinkler system(s) must be limited to a maximum leak rate of less than 3 psig (2 bar) within a 24 hour period, per system. Installation Instructions Installation of the ECS Protector requires five (5) steps: 1. 2. 3. 4. 5. Mount the cabinet in the appropriate installation location Bring the dedicated power supply to the cabinet Plumb the nitrogen/air supply line to the water based fire sprinkler risers being served Plumb the condensate drain line to floor drain or building exterior Connect Nitrogen generator output signals to BMS or fire alarm system, where applicable Step 1: Mounting the nitrogen generator cabinet The ECS Protector is designed to be mounted directly to the floor and/or the wall at the installation location. Several factors should be considered in choosing the proper mounting location for the nitrogen generator: Access to required power supply (dedicated circuit) Access to sprinkler risers being supplied from nitrogen generator Access to drain for the condensate discharge line Note: The cabinet includes pre-punched holes in the feet for floor mounting and holes in the back panel for wall mounting using standard anchors. Step 2: Power Supply The ECS Protector requires a dedicated power supply to prevent interruption from other equipment. The incoming power supply line ties into the top of the terminal blocks inside the nitrogen generator cabinet (see diagram). The landing points are labeled L1, N, and G. 120v/1 Phase 60 Hz Connections (230/1 Phase 50 Hz Connections) L1 N G Engineered Corrosion Solutions 11336 Lackland Road St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com ECS Protector PGEN-40(40E)/50(50E)/60(60E) 3

Step 3: Note: Step 4: Step 5: Plumb the Nitrogen/Air Supply Line The nitrogen/air discharge plumbing from the ECS Protector is to be connected directly to the sprinkler system valve trim using ½ to 1 black steel, galvanized steel, or copper lines. The size of the nitrogen/air supply line shall be based on both the length of pipe between the nitrogen generator and fire sprinkler systems and the total volume of fire sprinkler systems being supplied. The nitrogen generator requires an in-line Air Maintenance Device (AMD) that is equipped with an on board field adjustable pressure regulator for each zone being served. The preferred AMD is the Victaulic Series 757. When both dry pipe and preaction fire sprinkler systems are connected to one nitrogen generator, additional equipment may be required if the fire sprinkler systems operate at different supervisory gas pressures. Plumb the Condensate Drain Line The ECS Protector will occasionally discharge a small amount of condensate water from the coalescing filters inside the cabinet. It is recommended that the ¼ drain connection be plumbed to a floor drain or building exterior. When plumbing to a drain is not feasible an evaporative collection chamber can be used. System Signals and Monitoring, where used The nitrogen generator cabinet has two (2) system signals and five (5) outputs that can be monitored by the facility s BMS or fire alarm system. The nitrogen generator is operating in the bypass mode which is activated when the bypass valve is in the fast fill position to fast fill the fire sprinkler system and the air supplied directly from the air compressor has reached a pressure of 20 psig. (Flashing amber light) The nitrogen generator is equipped with a leak monitor audible signal which is activated when the nitrogen generator runs excessively. (Audible signal) The nitrogen generator cabinet includes system monitoring signals which can be monitored through a building monitoring system, if desired: Loss of Power (Form C contacts) Bypass Mode Alarm (Form C contacts) Nitrogen Generation Mode (Form C contacts) Nitrogen System Supply Line Pressure (Analog Signal) Leak Monitoring (Form C contacts) By-Pass Alarm Monitoring Output Nitrogen Generation Monitoring Output Power Monitoring Output Leak Monitoring Output ECS Protector PGEN-40(40E)/50(50E)/60(60E) 4

Typical ECS Protector Dry/Preaction System Schematic Nitrogen/Air Supply Line ECS Protector Dry Pipe Venting Device Nitrogen Generator Air Compressor Dry/Preaction Sprinkler Risers Typical ECS Protector Wet System Schematic Nitrogen Supply Line ECS Protector Injection Port Nitrogen Generator Air Compressor Nitrogen Storage Wet Pipe Sprinkler Risers Maintenance of the ECS Protector The nitrogen cabinet contains three separate cartridge filters (labeled 1-3 below) and one carbon filter (labeled 4 below). It is recommended that each filter be replaced as part of an annual preventative maintenance program. In some environments it may be necessary to replace filters more frequently. Engineered Corrosion Solutions offers a replacement filter kit for each model. When maintained properly the nitrogen separation membrane will provide up to 20 years of service life. Filter Replacement Procedure Preliminary Steps (taking the nitrogen generator out of service) 1. Turn the power supply to the unit off 2. Close the inlet and outlet ball valves on the bypass loop 3. Depressurize the nitrogen generator internal inlet piping by manually opening the pressure relief valve immediately downstream of the first two cartridge filters Coalescing Filter Cartridge Replacement Procedure The filters with condensate drain tube extending from the bottom of the filter housing are coalescing filters. To replace the filter cartridges follow Steps 1 through 6 on the following page. ECS Protector PGEN-40(40E)/50(50E)/60(60E) 5

2 1 4 3 Step 1: Step 2: Step 3: Grasp the ¼ clear drain tube on the bottom of the filter housing with the right hand. With the left hand, push upward on the grey retaining ring on the filter housing outlet fitting. This will allow for the ¼ clear drain tube to be removed from the fitting. Once the ¼ clear drain tube has been disconnected, the filter housing bowl may be unscrewed from the top portion of the filter housing which is connected to the internal system piping. Once the filter housing bowl has been unscrewed, the filter cartridge inside is removed by first unscrewing the black retaining disc at the base of the cartridge and then pulling down on the cartridge. Discard the old filter cartridge and replace it with the appropriately marked filter cartridge from the filter replacement kit by pushing up so that it fits snugly onto the receiving cylinder in the upper part of the filter housing. Screw the black retaining disc back onto the central metal threaded rod. Important: HAND TIGHTEN ONLY! Top of Filter Filter Cartridge Black Disc ECS Protector PGEN-40(40E)/50(50E)/60(60E) 6

Step 4: Step 5: Step 6: Replace the filter housing bowl by screwing it onto the filter housing top. Important: HAND TIGHTEN ONLY! Reconnect the ¼ clear drain tube into the fitting on the filter housing bowl. Make sure that it fully seats in the fitting and is retained snugly. Repeat Step 1 through Step 5 for each additional filter. Activated Carbon Filter Replacement Procedure The activated carbon filter is a 4 diameter aluminum cylinder installed downstream of the first two cartridge filters. To replace the activated carbon filter follow the steps below: Step 7: Using a wrench, disconnect the flexible tubing from the top and bottom of the filter housing at the ½ inlet and outlet fittings on the filter housing. Step 8: Step 9: Step 10: Step 11: Loosen the retaining brackets holding the filter housing to the back panel. The brackets will separate into halves and slide out from the metal channels behind the filter housing. Remove and discard the existing filter housing. Mount the new filter housing in the correct orientation (housing will be labeled with top and bottom decals) and tighten the retaining brackets. Connect the flexible tubing on the ½ inlet and outlet fittings on the filter housing. The ECS Protector can now be placed back into service. Return the ECS Protector to Service 1. Turn the power supply to the unit on. 2. Open the inlet and outlet ball valves, and close the bypass valve on the bypass loop. 3. Check inside the nitrogen generator cabinet for leaks using a soap water solution. Tighten fittings where needed. ECS Protector Optional Monitoring Equipment ECS Protector Handheld Gas Analyzer (PHGA-1): portable handheld gas analyzer includes one-button calibration and enables user to measure nitrogen concentration at nitrogen generator cabinet or gas sampling ports on ECS venting devices ECS Protector SMART Gas Analyzer (SGA-1/1E): permanently installed near an ECS Protector Manual/SMART Vent to continuously report nitrogen gas concentration to a building information or management system; includes digital display and provides 0-5V DC or 4-20mA output signals ECS In-Line Corrosion Detector (ILD-X): installed in-line within the fire sprinkler system piping at locations most susceptible to corrosion; provides either a local push-button test/indicator or control panel monitoring ECS Protector PGEN-40(40E)/50(50E)/60(60E) 7

8