control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

Similar documents
terminal unit accessories

Job Name Control Systems Description Date

I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

York 25-Ton VAV Rooftop Unit

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Verasys System Operation Overview Technical Bulletin

Your Home. Jacco & Assoc.

Ramp It Up VAV Ramps and Controller Possiblities

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

AirTrak. Digital Control System. User Manual. Touchscreen Systems

Feature Summary. I. System

T7984 A,B,C Electronic Modulating Control Thermostats

Digital Precise Air Control - DPAC

SECTION SEQUENCE OF OPERATIONS FOR BUILDING CONTROLS

INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Control Sequence Number

SEQUENCE OF OPERATIONS

Room Temperature Controller

2017 products.koer.com Page 1 of 14

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

FAN POWERED VAV TERMINALS

COMcheck Software Version Mechanical Compliance Certificate

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

CONTROL OPTIONS SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS PEH, PXH, RDH, REH, RXH, SDH & SHH. Horizontal Split System- Models PDH,

MicroTech Self-Contained Air Conditioning System

T6984 A,D,E Electronic Floating Control Thermostats

Zoning System Design Manual

1.0 Digital Controller

10+ HVAC Troubleshooting Tips for Healthcare Facilities Jerry Hirsch JCI Facility O&M Performance Development Manager.

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

Your Home. Jacco & Assoc. Fan on with call for heating or cooling Heating on with call from space thermostat Stage as

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

Electric Duct Heaters. IDHB & IDHC Series

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

T6590 Series FAN-COIL CONTROLLER

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

BAS Point Trend Data Guidance

DX-9100 Applications from Engineering Services

Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

AdaptAire. Digital Control System. User Manual. Expert Systems

T6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA

HVAC Controls Upgrades: Requirement Details ( )

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

DIGI-VAV APPLICATIONS

iworx Air Side Application Wiring Guide

Reference Guide for Microprocessor Controller

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

AdaptAire. Digital Control System. User Manual

VCB-X Modular Service Tool Technical Guide. VCB-X Controller Code: SS1051 Version 2.0 Requires Service Tool Code: SS1041 Version 2.

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

UNT Applications. Using UNT Applications...3. Introduction Key Concepts UNT Controller Applications Fan Coil Units...

Troubleshooting the Indoor AHU as a Standard Product

Reference Guide for Microprocessor Controller

CONTENTS. Installation Guide. VT7200 Series

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

Electric Coils. Blower Coils. Product Information

COMcheck Software Version Mechanical Compliance Certificate

Product Data. Features/Benefits. 33CS Carrier Comfort System Variable Volume and Temperature (VVT )

Spartan Peripheral Devices. TE 256S Thermostat Applications

AireLogic. Digital Control System. User Manual

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

SE7200 Series Installation Guide

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

Mechanical Compliance Certificate

1.0 Digital Controller

HVAC Controls Upgrades: Requirement Details ( )

Semi flush-mount room thermostat

COMcheck Software Version Mechanical Compliance Certificate

Reference Guide for Microprocessor Controller

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

COMcheck Software Version Mechanical Compliance Certificate

I/O ZONE 560/583 USERS GUIDE

features Overview Powerstar Room Thermostats Description Applications Selection Guide Thermostats & Hygrostats A-3

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

terminal unit accessories

IAQ: Re-tuning Commercial Buildings

OSU Alumni Center Phase I Implementation Review. Oregon State University 130 Oak Creek Bldg. Corvallis, Oregon

FAN POWERED VAV TERMINALS

TEC Controller Heat Pump Single Stage. Owner's Manual Building Technologies

Product Data. Features/Benefits. AirManager Control. 33AM Comfort System

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

Selected Laboratory Energy Efficiency Measures

Checked By: S. Norsworthy Approved By: C. Reimer

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Transcription:

control sequences Table 47: QST / EST Analog Electronic Control Strategies Control Package Number QST EST FS-A-5000 FSE-A-5000 FS-A-5001 FSE-A-5001 FS-A-5002 FSE-A-5002 FS-A-5003 FSE-A-5003 FS-A-5004 FSE-A-5004 FS-A-5020 FSE-A-5020 FS-A-5021 FSE-A-5021 FS-A-5022 FSE-A-5022 FS-A-5023 FSE-A-5023 FS-A-5024 FSE-A-5024 FS-A-5040 FSE-A-5040 FS-A-5041 FSE-A-5041 FS-A-5042 FSE-A-5042 FS-A-5043 FSE-A-5043 FS-A-5044 FSE-A-5044 FS-A-5060 FSE-A-5060 FS-A-5061 FSE-A-5061 FS-A-5062 FSE-A-5062 FS-A-5063 FSE-A-5063 FS-A-5064 FSE-A-5064 - Standard o - Optional VAV Cooling Notes: 1. : includes actuator, Fan interlock, plus volume regulator 2. VAV CV fan: cooling only, fan runs continuously 3. Constant Volume - regulates without T-stat (except heating). 4. Setback - fan/heat cycle during primary air shutdown 5. Shutdown - fan/heat locked-out during primary air shutdown CV Fan Night Cycling Night Shutdown Heat / Cool Auto Changeover CV Cooling Electric Heat (staged) Hot Water (on/off) Hot Water - Modulating Control Package Part # Ex: FS-A-5000 Fan Air Terminal Sequence # Electronic Analog Control System Control Package Part # Ex: FSE-A-5000 Fan Air Terminal (ECM) Sequence # Electronic Analog Control System Electric Heat - Modulating -34

VAV Cooling / Constant Volume Fan FS-P-3100 FS-P-3400 (pneumatic) FS-A-5000 FS-A-5004 (analog) FSE-P-3100 FSE-P-3400 (pneumatic) FSE-A-5000 FSE-A-5004 (analog) As the room air temperature increases above the thermostat setpoint, the actuator operates the terminal damper in response to the controller signal towards the open position, up to the maximum primary airflow setting. decreased, while keeping the discharge volume constant. As the room air temperature decreases below the thermostat setpoint, the actuator operates the terminal damper in response to the controller signal towards the closed position down to the minimum primary airflow setting. Respectively, the proportion of recirculated plenum air is increased, while keeping the discharge volume constant. The controller signal is determined by comparing the signals from the thermostat and flow sensor to provide the required primary airflow regardless of the inlet static pressure conditions the temperature continues to fall below the thermostat setpoint after having reached the minimum primary airflow setting. Primary airflow remains at the minimum setting while in the heating mode. If power is lost to the QST, the electronically controlled primary damper stops at its last commanded position. damper actuator and pressure independent controller. Pneumatic thermostats are not included. All electronic control packages listed above include the damper actuator, pressure independent controller, transformer and room thermostat. A trigger relay is provided with all electronic control packages where a hot water valve (on-off, by others) or up to three stages of electric heat are included. -35

Night Setback and Shutdown FS-P-3140 FS-P-3440 (pneumatic) FS-A-5020 FS-A-5024 (analog) FSE-P-3140 FSE-P-3440 (pneumatic) FSE-A-5020 FSE-A-5024 (analog) Same as (VAV Cooling / CV Fan) In addition, setback occurs when the AHU is off, and the duct pressure switch senses no duct pressure, and turns the QST fan off. uring setback condition, the QST fan is cycled on and off by the thermostat. As the temperature drops, the QST fan will energize, providing 100% induction air (damper remains at minimum position). the temperature continues to fall below the thermostat setpoint only after the QST fan is on. As the space temperature rises, both the optional heat and QST will be shut off sequentially. If power is lost to the QST, the electronically controlled primary damper stops at its current position. damper actuator, PE fan switch, fan relay, duct pressure switch and pressure independent controller. Pneumatic thermostats are not included. All electronic control packages listed above include the damper actuator, duct pressure switch, fan relay, pressure independent controller, transformer and room thermostat. A trigger relay is provided with all electronic control packages where a hot water valve (onoff, by others) or up to two stages of electric heat are included. ay Mode ay Mode Night Setback Mode Night Setback Mode -36

Night Shutdown FS-P-3160 FS-P-3460 (pneumatic) FS-A-5040 FS-A-5044 (analog) FSE-P-3160 FSE-P-3460 (pneumatic) FSE-A-5040 FSE-A-5044 (analog) Same as above (VAV Cooling / CV Fan) In addition, shutdown occurs when the AHU is off, and the duct pressure switch senses no duct pressure, and turns the QST fan off. the temperature continues to fall below the thermostat setpoint. As the space temperature rises, the optional heat will be shut off. damper actuator, fan relay, duct pressure switch and pressure independent controller. Pneumatic thermostats are not included. All electronic control packages listed above include the damper actuator, duct pressure switch, fan relay, pressure independent controller, transformer and room thermostat. A trigger relay is provided with all electronic control packages where a hot water valve (on-off, by others) or up to three stages of electric heat are included. -37

Auto Heat/Cool Changeover FS-A-5060 FS-A-5064 (analog) FSE-A-5060 FSE-A-5064 (analog) Cooling Mode: (primary air temperature is below 73F): As the room air temperature increases above the thermostat response to the controller signal towards the open position up to the maximum primary airflow setting. Respectively, the proportion of recirculated plenum air is decreased, while keeping the discharge volume constant. As the room air temperature decreases below the thermostat response to the controller signal towards the closed position down to the minimum primary airflow setting. increased, while keeping the discharge volume constant. Heating Mode: (primary air temperature is above 81F) As the room air temperature increases above the thermostat response to the controller signal towards the closed position down to the minimum primary airflow setting. increased, while keeping the discharge volume constant. As the room air temperature decreases below the thermostat response to the controller signal towards the open position up to the maximum primary airflow setting. Respectively, the proportion of recirculated plenum air is decreased, while keeping the discharge volume constant. The controller signal is determined by comparing the signals from the thermostat and flow sensor to provide the required primary airflow regardless of the inlet static pressure conditions the temperature continues to fall below the thermostat setpoint. As the space temperature rises, the optional heat will be shut off. All electronic control packages listed above include the damper actuator, pressure independent controller, transformer, heat/cool changeover module, temperature sensor and room thermostat. A trigger relay is provided with all electronic control packages where a hot water valve (on-off, by others) or up to three stages of electric heat are included. Heating Set Point Cooling Set Point -38