World Class Leaders in Fire Detection Since SYSTEMSCATALOGUE UL Fire Detection Systems

Similar documents
FIRE ALARM SYSTEM. FireNET ANALOG ADDRESSABLE CONTROL PANEL. FireNET Plus ANALOG ADDRESSABLE CONTROL PANEL

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment

PRODUCT BROCHURE THE WORLD S FINEST FIRE DETECTION SYSTEMS SINCE 1918 UNITED KINGDOM USA JAPAN MIDDLE EAST USA TAIWAN MEXICO INDIA THAILAND SINGAPORE

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Cover Inside Front & Back

ALK-V PHOTOELECTRIC SMOKE SENSOR

Addressable Fire Alarm Control Panel

CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

FireNET Plus Analog Addressable Fire Alarm System Installation and Operation Manual

FireNET Plus Wiring Instructions

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Conventional Releasing Control Panel

FIRE DETECTION SYSTEMS. Product Guide

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

FIRE DETECTION SYSTEMS. Product Guide

Bosch EVAX System - High-rise Applications

Specification/ Data Sheet

July 14, 1999 DF C-100.

Intelligent Single Loop Fire Alarm Control Panel

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

LifeAlarm Fire Alarm Control Panels

good things in small packages

AND ARCHITECT SPECIFICATIONS

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Intelligent 2 & 4 Loop Fire Alarm Control Panels

AND ARCHITECT SPECIFICATIONS

DS7400Xi Addressable Control/ Communicator

ECC-50/100C. Emergency Command Center

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

E3 Series Broadband System

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Multi-Point Peripherals

TrueAlert Notification Appliances

D7024 Fire Alarm Control Panel

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Multi-Point Peripherals

ECC-50/100(E) Emergency Command Center

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Addressable and Conventional Fire Protection

Desigo TM Fire Safety System A comprehensive fire-protection system

June 10, 2002 DF C S2424

TrueAlarm Fire Alarm Controls

INTELLIGENT FIRE ALARM CONTROL PANEL

Across-the-Line SERIES MP300 Combined Manual and Automatic

SECTION FIRE ALARM SYSTEMS

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

Intelligent addressable fire alarm control panel

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

SAFEPATH Mass Notification System (SPMNS)

E3 Series Broadband System

LifeAlarm Fire Alarm Controls

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

SP40S-D. Kingfisher Company, inc. Features: Description:

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Solution F2. Fire Alarm Control Panels one step ahead.

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Soft Start Series MP700 Solid State, Reduced Voltage

Mircom FX /01/16

DCP-FRCME - FAST RESPONSE CONTACT MODULE

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Fire Alarm System Fundamentals

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

s Notification Appliances

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

TECHNICAL DATA OBSOLETE

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

For Complete Fire and Gas Solutions

Addressable Detectors & Bases

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

SIGA-CC1 Single Input Signal Module Installation Sheet

Fire Product Catalog

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Desigo TM Fire Safety System A comprehensive fire-protection system

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

TrueAlert Addressable Notification Appliances

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TrueAlarm ES Analog Sensing

Cerberus PRO A comprehensive fire-protection system

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Transcription:

World Class Leaders in Fire Detection Since 1918 UL SYSTEMSCATALOGUE UL Fire Detection Systems

FireNET u Network Diagram 4 u Control Panels 6 u Control Panel Peripherals 8 FireNET Vapor u Air Sampling Detectors 9 FireNET & FireNET Plus u Accessories 10 Analogue UL Devices u Sensors 12 u Bases 13 Notification Appliances u Sounders & Beacons 20 Service Test Equipment u Detectors Testers & Removal Tool 23 u Hand Held Programmer 24 Conventional u Control Panels 25 u Smoke Detectors 27 u Heat Detectors 30 u Bases 31 u Beam Detection 32 Analogue UL Addressable Modules u Modules & Pull Stations 14 u Cables & Duct detector 16 Power Supplies/ Extenders u Power Supplies/Extenders 17 Additional Conventional Products u Duct Detection 33 u Beam Detection 33 u Pull Stations 33 u System Abort Push Button 35 Index 36 VoiceNET u Control Panels 18 u Accessories 18 u Conventional Voice Evacuation System 19 2

THE HISTORY OF THE HOCHIKI GROUP OF COMPANIES The history of Hochiki dates back to 1918, with the formation of the Hochiki Group of Companies. Significant events in Hochiki s history are dated up to present day: 1918 Hochiki Corporation was established in Tokyo, Japan as Japan s first manufacturer of fire alarm equipment. 1920 The world s first addressable fire alarm system was installed in Japan by Hochiki Corporation. 1951 The production of the Rate-of-Rise heat detectors. 1967 The lonization Smoke Detector was developed. 1972 Hochiki America Corporation subsidiary was established, Hochiki Research Laboratory in Tokyo, Japan was established and Hochiki lionization Smoke Detector was approved by Underwriters Laboratories, Inc. 1973 Intrinsically Safe Fire Alarms System was developed. 1977 Hochiki America moved its facility from Hawaiian Gardens, CA to Huntington Beach, CA. 1984 Hochiki America began manufacturing detector bases. 1986 The current analogue addressable fire protocol was developed Digital Communication Protocol (DCP). 1988 Hochiki America began operation as a manufacturing facility with additional production lines of smoke detector and bases being transitioned over to the United States from Japan. 1991 Hochiki Europe (UK) Ltd. was established in Kent, United Kingdom. 1992 Hochiki America established APA Technology, Inc., a subsidiary of Hochiki America and Hochiki Corporation. 1994 Hochiki America obtained ISO 9002 certification. 1995 Hochiki Corporation opened one of the world s largest fire testing facilities in Miyagi, Japan. 1997 Hochiki Singapore Branch Office was established. 1998 APA Technology Inc. merged with Hochiki America. 1999 Hochiki America moved to a larger facility in Buena Park, CA. 2001 The Beijing, China representative office was established. 2003 Hochiki America introduced its first UL approved analogue addressable fire alarm control panel - the FireNet. 2006 The Hochiki Fire Prevention Technology Corporation was established in Beijing, China. 2007 Hochiki America acquired UL 864 9th Edition listing for FireNet. 2007 Hochiki America begins production of new models, ALK-V and SLV-24. 2010 Hochiki Europe launched FIREscape, the UK's first Intelligent LED-based emergency lighting systems. 2012 Hochiki America celebrated its 40th anniversary, Hochiki Corporation Japan acquired Kentec Electronics Ltd and Hochiki America acquired VES, LLC, a subsidiary of Kentec Electronics, Ltd. 2013 Hochiki Corporation establishes Hochiki Middle East FZE Branch office in Dubai. 2015 Hochiki Europe establishes India Sales Branch Office in New Delhi, India. Over 90 years later, the Hochiki Group of Companies consists of 6 factories, 10 subsidiaries and 33 branches throughout the world. Anchored by Hochiki Corporation, Hochiki America and Hochiki Europe, we are combining our efforts to offer the highest quality and most reliable fire products to meet today s ever-changing global market. 3

FIRE ALARM SYSTEMS Graphic LED Display (FNP-LED) AMS R2M SOM CZM DIMM ACC-V FRCME-M ATJ-EA Central Station ALN-V Duct Detector Notification Appliances RS-485 SLC (DCP) Phone Lines Phone Lines FN-DAC RS-232 CZM Conventional Detectors NAC Power Extender NAC FireNET PLUS DIMM/ CLIM Printer (RS-232) FireNET RS-485 Network Up to 64 Nodes FireNET SLC (DCP) COMMS (RS-485) FireNET Vapor Detector VoiceNET TM Voice Evacuation System Network Annunciator Serial Annunciator IO IO FNV-FJ RS-485 FNV-FH Notification Appliances Building IO System 4 5 Graphix Software

FireNET At the backbone of the FireNET Analogue addressable system is the FireNET control panel itself. Utilizing Hochiki s patented Digital Communication Protocol (DCP), it allows for robust intelligent communication with other Analogue addressable products. An RS-485 bus provides communication to the panel network, while the RS-232 interface allows the convenience of programming via a PC. The panel supports any combination of addressable devices, up to 127 per signaling line circuit, including thermal and photoelectric smoke detectors/sensors, and monitoring and control modules. The Loop Explorer Windows based software interface provides the installer with fingertip access to installation programming and diagnostic tools. FireNET ANALOGUE ADDRESSABLE CONTROL PANEL (2 or 4 loop) UL 864 9th Edition Listed, FM Approved, CSFM Approved & FDNY Approved Seismic certified Analogue design using Hochiki s advanced DCP protocol for fast & robust communication Network capability up to 64 panels with 500 network-wide software zones Up to 127 sensors & modules, plus 127 analogue sounder bases, for a total of 254 points possible per loop Large 8-line x 40-character LCD display (320 characters) Dual RS-485 bus for panel network FireNET Plus ANALOGUE ADDRESSABLE CONTROL PANEL (1 or 2 loop) UL 864 9th Edition Listed, FM Approved, CSFM Approved 1 SLC (2nd SLC optional) Analogue design using Hochiki s advanced DCP protocol for fast & robust communication Network capability up to 64 panels with 500 network-wide software zones RS-485 bus for panel networking (optional) Up to 127 sensors & modules, plus 127 analogue sounder bases, for a total of 254 points possible per loop Large 8-line x 40-character LCD display (320 characters) RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 17 FN-4127-IO boards Built-in RS-232 interface for programming via a PC and serial printer interface 5 on-board programmable Form C relays rated at 1 Amp at 30VDC Supports Class B, Class A and Class X SLC loops 4 on-board Class B NAC circuits rated at 2.5 Amps each Powerful & versatile Cause & Effect programming Available color(s): Red or grey Built-in RS-232 interface for programming via a PC Supports Class B, Class A and Class X SLC loops 3 on board programmable Form C relays rated at 1 Amp at 30VDC 2 auxiliary power outputs, each rated 360mA at 24 VDC 2 on-board Class B NAC circuits rated at 2.3 Amps each (special application) and 1.6 Amps each (regulated continuous) Fire Drill function and Walk Test function Powerful & versatile Cause & Effect programming Available color(s): Red or grey FN-LCD-S SERIAL ANNUNCIATOR UL Listed, FM Approved, CSFM Approved & FDNY Approved 320 character liquid crystal display (8 line x 40 character) Same controls as the FireNET fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter and Exit) Network capability up to 64 panels with 500 network-wide software zones RS-485 bus for panel networking (optional) Up to 15 FN-LCD-S serial annunicators may be connected to a FireNET control panel or network annunciator Resides on the FireNET slave RS-485 line Local piezo sounder for event notification Supports user codes and firefighter key to enable access and controls Powered by FireNET auxiliary 24VDC or UL fire listed auxiliary 24VDC supply Built-in help and alarm information screens Fire Drill function Available color(s): Red or grey 6

FireNET FN-LCD-N NETWORK ANNUNCIATOR UL Listed, FM Approved, CSFM Approved & FDNY Approved 320 character liquid crystal display (8 line x 40 character) Dual RS-485 ports for primary fire network RS-485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 17 FN-4127-IO boards Built-in RS-232 interface for programming via a PC and serial printer interface FNP-LED UL Listed, FM Approved, CSFM Approved Up to 504 LEDs can be controlled with FireNET Plus panel Available in 3 different size enclosures LEDs comes in 3 different colors: red, green or yellow FNP-LED can be easily upgraded onsite with minimal cost and effort Available color(s): Red or grey Same controls as the FireNET fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter and Exit) Local piezo sounder for event notification Supports user codes and firefighter key to enable access and controls Powered by FireNET auxiliary 24VDC or UL fire listed auxiliary 24VDC supply Surface or flush mount (using trim ring) Up to 64 FireNET panels and FN-LCD-Ns can be networked together in any combination 500mA of auxiliary power available rated at 24VDC Available color(s): Red or grey 7

FireNET FN-ACC-R/C BATTERY ENCLOSURE FN-ACC-R/C is designed to provide a method to properly store backup batteries larger than 17Ah for the FireNET and FireNET Plus panels The enclosure can also be used to mount 16 channel IO boards Includes: key lock and FireNET accessory enclosure with kit Optional seismic kit is available (FN-ACCS-K) Available color(s): Red or grey FireNET Graphix Software Package Choice of text, graphic, event list display when event occurs Versatile event analysis and total history archive Easy to program and simple to use Secure system Unlimited map linking Display and control for multiple panels CONTROL PANEL PERIPHERALS EMS Graphix Software UL 864 Listed, CSFM Approved Compatible with FireNET 2127/4127, FireNET Plus, and FireNET Network Annunciator Real-time display of text, graphic, and event list (Fire, Supervisory, Trouble) Color coded event list Unlimited amount of history storage Ability to send panel control commands (Panel Sounder Silence, Alarm Silence, Reset) Easy to program and simple graphical user interface (GUI) Secure system Ability to import Autocad drawings Event history can be viewed, filtered and exported to text or HTML document 8

FireNET Vapor FireNET Vapor - VPR-1P AIR-SAMPLING SYSTEM Single Zone Dual Pipe Air Sampling 0.0003-6.10 %/ft obscuration (0.001-20 %/m) 4 Alarm Levels - Alert, Action, Fire 1, Fire 2 FireNET Vapor - VPR-1 AIR-SAMPLING SYSTEM Single Zone Four Pipe Air Sampling 0.0003-6.10 %/ft obscuration (0.001-20 %/m) 4 Alarm Levels - Alert, Action, Fire 1, Fire 2 4 x 328ft (4 x 100m) sampling pipes Enhanced performance aspirator Ethernet TCP/IP Modbus interface for programming FireNET Vapor - VPR-15 AIR-SAMPLING SYSTEM 15 Tube Addressable Air Sampling 0.0003-6.10 %/ft obscuration (0.001-20 %/m) 4 Alarm Levels - Alert, Action, Fire 1, Fire 2 15 x 164ft (15 x 50m) microbore sampling tubes Reliable linear pump technology Ethernet TCP/IP Modbus interface for programming 5 relay outputs FireNET Vapor - VPR-4 VPR-15& VPR-6 AIR-SAMPLING AIR-SAMPLING SYSTEM SYSTEM 15 Tube Addressable Air Sampling 4 or 6 pipe addressable air sampling 0.0003-6.10 %/ft obscuration 0.0003-6.10 %/ft obscuration (0.001-20 %/m) (0.001 20 %/m) 4 Alarm levels - Alert, Action, Fire 1, Fire 2 4 Alarm Levels - Alert, Action, Fire 1, Fire 2 4 x 328ft (4 x 100m) or 6 x 326ft (6 x 100m) sampling pipes 15 x 164ft (15 x 50m) microbore sampling tubes Enhanced performance aspirator Reliable linear pump technology Ethernet TCP/IP Ethernet TCP/IP Modbus over RS232 and RS485 Modbus interface for programming 5 relay outputs and expandable 5 relay outputs Optional 4 to 20 ma analog outputs and relay cards Area coverage of up to 21,500 ft 2 (2000 m 2 ) 2 x 328ft (2 x 100m) sampling pipes Enhanced performance aspirator RS232 and RS485 Modbus interface for programming 5 relay outputs Area coverage of up to 9,150 ft2 (850 m2) 5 relay outputs Optional 4 to 20mA analogue outputs and relay cards Area coverage of up to 21,500 ft2 (2000 m2) Optional 4 to 20 ma analogue outputs and relay cards Area coverage of up to 16,150 ft 2 (1500 m 2 ) Optional 4 to 20mA analogue outputs and relay cards Area coverage of up to 16,150 ft2 (1500 m2) 9

FireNET & FireNET Plus ACCESSORIES FNP-1127-SLC (FireNET Plus ) SINGLE LOOP EXPANDER Adds one SLC loop to the FireNET Plus (FNP-1127E series) control panel The SLC loop is capable of 127 sensors/modules, plus 127 analogue sounder bases, for a potential total of 254 addresses The FireNET Plus 1127E control panel supports one FNP-1127-SLC, for a total of two SLC loops per panel FN-4127-SLC (FireNET ) DUAL SLC LOOP EXPANDER Adds two SLC loops to a two loop FireNET control panel Each SLC loop is capable of 127 sensors/modules, plus 127 analogue sounder bases, for a potential total of 254 addresses per loop (127+127 per loop) FN-4127-SLC can be added at the factory or installed in the field Supports Class A, B and X wiring methods per NFPA 72 (Class X requires isolators) Fully supervised & power limited SLC loop One SLC expander (maximum) may be added per FireNET control panel Each SLC loop is completely independent and autonomous Supports Class A, B and X wiring methods per NFPA 72 (Class X requires isolators) Fully supervised & power limited SLC loop FN-4127-IO 16 CHANNEL INPUT/OUTPUT BOARD (RS-485 BUS DEVICE) 16 channels of input/output points 32 IO boards per FireNET panel (512 channels of input/output points) Each channel configurable as input/output point Inputs are opto-isolated non-supervised pulldown type triggered by dry contact from input source Outputs are open collector transistor pulldown type (100mA max each) that provide wet voltage output Simple 4 wire connection to control panel (2 for power, 2 for data) All inputs/outputs can be assigned to global functions, any event category, and used in network-wide Cause and Effect logic Can be mounted locally within control panel enclosure or remotely via FN-ACC accessory enclosure up to 4,000 feet from the panel FN-4127-NIC NETWORK INTERFACE CARD Allows for the expansion of up to 64 panels on a FireNET system Enables information to be transmitted between control panels Network protocol designed for tolerance to interference and data corruption Each card configured to a unique address through use of a dipswitch Transmission distance of up to 4,000 feet Uses standard type Belden cable suitable for RS-485 applications Network-wide Cause & Effect logic 10

FireNET & FireNET Plus ACCESSORIES FN-DAC (FireNET ) DIGITAL ALARM COMMUNICATOR UL 864 9th Edition Listed Contact ID and SIA reporting formats Programmable from FireNET control panel or by using Loop Explorer Zone or address (point) reporting Remote upload/download and diagnostic tools Backup and duplicate reporting Programmable daily test report interval 11

ANALOGUE SENSORS ACC-V ANALOGUE MULTI-CRITERIA SENSOR Low profile only 2.00" high, including base Combination smoke/heat sensor Simple and reliable device addressing Automatic compensation for sensor contamination Uses the noise-immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires ALN-V PHOTOELECTRIC SMOKE SENSOR Low profile - only 2.00" high, inlcuding base Simple and reliable device addressing Automatic compensation for sensor contamination Built-in fire test feature Uses the noise-immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires Two built-in power/alarm LEDs Non-directional smoke chamber Vandal resistant security locking feature Available color(s): Ivory Built-in fire test feature Two built-in power/alarm LEDs Vandal resistant security locking feature Available color(s): Ivory ATJ-EA FIXED TEMP/RATE OF RISE HEAT SENSOR Low profile - only 2.00" high, inlcuding base Simple and reliable device addressing method Uses the noise immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires Rate of rise temperature threshold = 15 F/min (determined by panel) Adjustable threshold temperature = 135 F - 190 F (determined by panel) UL maximum spacing of 70 feet Two built-in power/alarm LEDs Vandal resistant security locking feature Built-in fire test feature Available color(s): Ivory 12

ANALOGUE BASES ASB ANALOGUE SOUNDER BASE UL Listed, FM Approved, CSFM Approved Programmable evacuation codes Continuous, March, ANSI Temporal patterns Base learns the sensor address and assumes an upper range address (128-254) Up to 127 sensors and 127 ASBs can be used on one SLC loop ASBL ANALOGUE LOW FREQUENCY SOUNDER BASE UL 268 Listed, UL 464 Listed, CSFM Approved Programmable evacuation codes Continuous, March, ANSI Temporal patterns 520Hz low frequency alarm signal meets NFPA requirements for sleeping areas Base learns the sensor address and assumes an upper range address (128-254) Up to 127 sensors and 127 ASBLs can be used on one SLC loop Programmable activation by general alarm, by zone and/or by individual address Available color(s): Ivory Programmable activation by general alarm, by zone and/or by individual address High sound pressure level (85dB SPL at 10 feet) (Fire, Supervisory, Trouble and Auxiliary) Available color(s): Ivory HSB-NSA-6 & YBN-NSA-4 ANALOGUE SENSOR BASES UL Listed, ULC Listed, FM Approved,CSFM Approved Designed for use with all NS analogue sensors Available in 4" and 6" models analogue Available color(s): Ivory SCI-B4 & SCI-B6 SHORT CIRCUIT ISOLATOR ANALOGUE SENSOR BASES Ability to detect short circuit conditions Designed for use with all DCP Analogue sensors Available in 4" and 6" models Built-in LED indication upon short circuit condition Available color(s): Ivory 13

ANALOGUE ADDRESSABLE MODULES The analogue addressable module product line utilizes the patented Hochiki Digital Communication Protocol (DCP) for fast reliable communication to the control panel. The modules cover a variety of applications including contact monitoring, output, relay function, and short circuit isolation. These modules (except for the DCP-FN-CTM, City Tie Module) operate on Class A or Class B SLC loops, allow 127 devices per DCP loop and are available in ivory colour. * Front view DCP-CZM CONVENTIONAL ZONE MODULE UL Listed, FM Approved, CSFM Approved Allows the panel to interface and monitor two-wire conventional detectors or pull stations Supervises the power supply and entire zone of devices Device address can be programmed with a hand-held programmer Status conditions are reported as Normal, Open or Alarm DCP-DIMM DUAL INPUT MONITOR MODULE UL Listed, CSFM Approved Fast, reliable contact monitoring utilizing the Hochiki DCP (Digital Communications Protocol) Bi-colored indicating LED provides module status Dual input contact monitor Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts Mounts to a standard 4" square or double gang electical back box DCP-FN-CTM CITY TIE MODULE Integrates fire alarm control panel EOL device into module for supervision of interface wiring Interfaces fire alarm control panels to a local energy type city tie monitoring circuit Wide operating voltage Power limited operation Transient protection Mounts to a standard 4" electrical back box DCP-FRCMA & DCP- FRCMA-I FAST RESPONSE CONTACT MODULES UL Listed, FM Approved, CSFM Approved Yellow LED indicates a short circuit condition (FRCMA-I only) Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts Single input contact monitor Accepts up to 14 AWG wire * Rear view DCP-R2ML, DCP-R2ML-I, DCP- R2MH, DCP-R2MH-I DUAL RELAY MODULES UL Listed, FM Approved, CSFM Approved Contacts are rated as follows: - R2ML: 2A @ 30VDC / 0.5 @ 120 VAC - R2MH: 8A @ 30VDC / 4.8A @ 250 VAC Yellow LED indicates a short circuit condition (DCP-R2ML-I & DCP-R2MH-I only) DCP-SCI SHORT CIRCUIT ISOLATOR Checks SLC line for short circuit at power up Indication of a single short circuit by a yellow LED DCP-SOM-A & DCP- SOM-AI SUPERVISED OUTPUT MODULES UL 864 Listed, FM Approved, CSFM Approved Built-in SCI circuitry (SOM-AI only) Flexible application Quick response to emergency conditions Contacts are rated 2.0 Amps @ 24VDC Programming is highly flexible providing 16 priority states plus zoning capability DCP-SOM-R SUPERVISED OUTPUT MODULE UL Listed, FM Approved, CSFM Approved Flexible pre-action application Quick response to emergency conditions Flexible pre-action application Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not required Contacts are rated 2.0 Amps @ 24VDC Programming is highly flexible providing 16 priority states plus zoning capability 14

ANALOGUE ADDRESSABLE MODULES DCP-FRCME-M FAST RESPONSE CONTACT MODULE UL Listed, FM Approved, CSFM Approved Single input contact monitor Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts Accepts up to 14 AWG wire Built-in RS-232 interface for programming via a PC and serial printer interface FRCME-P FAST RESPONSE CONTACT MODULE UL Listed, FM Approved, CSFM Approved Single input contact monitor Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts TCF-142-M-ST FIBER OPTIC MODULE Capability to network FireNET, FireNET Plus, and network annunciator using fiber optic cables Extends RS-485 transmission up to 3.1 miles Protects against electrical interference and chemical corrosion No special programming required DCP-AMS SERIES ANALOGUE ADDRESSABLE MANUAL PULL STATIONS UL Listed, FM Approved, CSFM Approved Addressable integrated design Extremely easy to operate Bi-colored status LED indicates Standby and Alarm conditions Address is programmable in EEPROM Terminals accept up to 14 AWG wire Surface mount back box available Model descriptions: single or dual action, key lock or hex key lock Models: DCP-AMS, DCP-AMS-LP, DCP-AMS-KL, DCP-AMS-KL-LP Available color(s): Red 15

ANALOGUE ADDRESSABLE MODULES DH-99 SERIES ANALOGUE DUCT DETECTOR, meets UL 268A requirements Detects and limits the spread of smoke throughout building HVAC ducts Compatible with building automation and fire alarm systems Installs quickly and easily No screens or filters to clean Rugged gray steel back box with clear cover Accessories - remote LED alarm indication capability (DH-99-AR only) X187/S187 PROGRAMMING CABLES Cable Type: FireNET Family Programming Cable Length: 8.3 feet (2.5 meters) Left Connector: 10 pin serial (female) Right Connector: 9 pin - DB9 (female) X187: Non-jacketed version S187: Jacketed version FN-V187 VOICENET INTERFACE CABLE Cable Type: VoiceNET integration cable Cable Length: 8.3 feet (2.5 meters) Left Connector: 10 pin serial (female) Right Connector: 2 wire pin (male) FN-P187 PRINTER INTERFACE CABLE Cable Type: FireNET /FireNET Plus printer cable Cable Length: 8.3 feet (2.5 meters) Left Connector: 10 pin serial (female) Right Connector: 25 pin serial (male) 16 55

POWER SUPPLIES & POWER EXTENDERS PE-XXSN Model PE-6SN PE-10SN FN-642-ULADA FN-842-ULADA FN-1042-ULADA FN-300-ULX FN-400-ULX FN-600-ULX FN-1024-ULX FN-XXX-ULX Supply Voltage 120/240 VAC 50/60 Hz 120/240 VAC 50/60 Hz 115 VAC 60 Hz 115 VAC 60 Hz 115 VAC 60 Hz 115 VAC 60 Hz 115 VAC 60 Hz 115 VAC 60 Hz 115 VAC 60 Hz FN-XXX-ULADA Output Rating 6 Amps regulated 10 Amps regulated 6.5 Amps 8 Amps 10 Amps 2.5 Amps 3 Amps 6 Amps 10 Amps Synchronization Built-in sync protocol Built-in sync protocol Built-in sync protocol Built-in sync protocol Built-in sync protocol 17

VoiceNET TM FNV-FH PORTABLE HANDSET Available color(s): Red FNV-FJ TELEPHONE JACK Brushed stainless steel single gang FNV-MP & FNV-DP VOICE EVACUATION SYSTEM UL 864 9th Edition Listed, CSFM Approved True multiplex 6 channel distributed audio Integrated fire phone (optional) Modular system - components added as needed Integrated 2 channel digital message repeater Live microphone page to any zone Fast RS-485 communication protocol Up to 4 minute message capacity Works with 12VDC or 24VDC fire alarm panels UL Listed to be integrated with FireNET 2127/4127 FNV-TC TELEPHONE CABINET Holds 6 FNV-FH Portable Handset Surface/semi-flush mount Available color(s): Red or charcoal 3 minute message restart on microphone key Up to 4 minute message capacity Up to 255 distributed panels Available color(s): Red or charcoal (Shown with 6 FNV-FH) 18 19

VoiceNET TM FNV-WS WARDEN STATION Armored cable / thumb turn latch Surface/semi-flush mount Available color(s): Red FNV-FS FIRE PHONE STATION Coil cord / thumb turn latch Surface/semi-flush mount Available color(s): Red EVAX 25/50/100/150/200/300/400/500 /600 CONVENTIONAL VOICE EVACUATION SYSTEM Clean dead-front construction Digitally recorded automatic voice evacuation (up to 4 minutes of message capacity) 25/50/100/150/200/300/400/500/600 watt high efficiency digital system 25 or 70 VRMS field selectable 120 VAC power supply and battery charger Live microphone override of message and tone Analogue addressable compatible High reliability, no maintenance, fully supervised Easy installation and operation Natural voice sound recordings Built-in alarm and alert signals Works with 12VDC or 24VDC fire alarm panels UL Listed to be integrated with FireNET 2127/4127 3 minute message restart on microphone key Up to 4 minute message capacity Up to 255 distributed panels Available color(s): Red or charcoal 19

NOTIFICATION APPLIANCES HE SERIES SELECTABLE CANDELA EVACUATION SIGNALS Nominal voltage 12VDC and 24VDC 24VDC units have field selectable candela options of 15, 30, 60, 75, and 110 12VDC units have field selectable candela options of 15, 30, 60, and 75 Synchronize strobe and/or horn with Hochiki series control module (12VDC product must use the HAVSM module) Input terminals support 12 to 18 gauge wire HSSPKCLP SERIES CEILING MOUNT SPEAKER/STROBE Nominal voltage 24 VDC Tamperproof field selectable candela options of 15, 30, 75, 95 & 115 Synchronize HSSPKCLP Series by using Hochiki America Series HAVSM Synchronization Module High quality dba output Frequency range 400-4000Hz Switch selection for high or low dba Switch for chime, whoop, mechanical and 2400Hz tone Switch for continuous or temporal 3 (not available on Whoop tone) Surface mount with the HSB (Hochiki ceiling/surface mount box) Silence horn while strobes remain flashing Wide voltage range 8-17.5VDC (12VDC units) 16-33VDC or FWR (24VDC units) Available color(s): Red or ivory Input terminals support 12 to 18 AWG Field selectable power taps: 1/8W, 1/4W, 1/2W, 1W, 2W and 4W Field selectable speaker voltage 25 or 70.7 VRMS standard Tamperproof grill Strobe maintains constant flash rate (1Hz) regardless of input voltage Available color(s): Red or ivory HSSPKWLP SERIES WALL MOUNT SPEAKER/STROBE Nominal voltage 24 VDC Tamperproof field selectable candela options of 15, 30, 60, 75, 110 and fixed 15/75 Synchronize HSSPKWLP Series by using Hochiki America HAVSM Synchronization Module High quality dba output Frequency range 400-4000Hz Input terminals supports 12 to 18 AWG Field selectable power taps: 1/8W, 1/4W, 1/2W, 1W, 2W and 4W HC SERIES SELECTABLE CEILING MOUNT STROBE AND HORN STROBE Nominal voltage 24 VDC Tamperproof field selectable candela options of 15, 30, 75, 95,115 & 150 Synchronize HC Series by using Hochiki America Series Control Module Input terminals support 12 to 18 AWG Switch selection for high or low dba Switch selection for 2400Hz or mechanical tone Switch selection for continuous or temporal 3 Tamperproof re-entrant grill Surface mount with the HCSB (Hochiki Ceiling Surface Mount Box) Field selectable speaker voltage 25 or 70.7 VRMS standard Tamperproof grill Strobe maintains constant flash rate (1Hz) regardless of input voltage Available color(s): Red or ivory Silence horn while strobes remain flashing Wide voltage range 16-33 VDC or FWR Available color(s): Red or ivory 20

NOTIFICATION APPLIANCES HX93 SERIES MINI-HORN Nominal voltage 12VDC and 24VDC Jumper for selectable temporal 3 or continuous tone Horn frequency of 3100Hz Input terminals support 12 to 18 gauge wire Low current consumption Textured finish high impact plastic faceplate Available color(s): Red or ivory HEP & HEPS SERIES COLORED LENS EXPANDER PLATE STROBE Nominal voltage 24 VDC Available lens colors: amber, blue, green and red Amber lens models have field selectable candela options: 15, 30, 60, 75 and 110 Blue, green and red lens models are fixed 15/75 candela HEP dimensions: 10.8" H x 6.6" W x 2.8" D HEPS dimensions: 11.5" H x 7.26" W x 5.04" D ALERT text on all units Wall mount to a standard 4" square x 2.125" deep back box HHLF SERIES LOW FREQUENCY AUDIBLE SIGNAL UL Listed Nominal voltage 24 VDC Unit dimensions: 6.125" H x 5.5" W x 1.625" D Synchronize horn with Hochiki HTSM Synchronization Control Module Prewire entire system, install mounting bracket, then install signals Input terminals accept 12 to 18 AWG Produces a 520Hz square wave, temporal 3 tone Jumper selection for normal or loud dba Temporal 4 pattern available when used with Hochiki HTSM Synchronization Module HAVSM SYNCHRONIZATION CONTROL MODULE Synchronize horn and strobe with the use of only two wires Module is rated for 3 Amps continuous current and 5 Amps surge or inrush current Synchronizes to 1Hz flash rate Operates 1 Class A circuit or 2 Class B circuits at 3 Amps per circuit Dual synchronization module only when using Class B circuits A green LED status indicator Option to silence the horn while strobes continue to flash when using Temporal 3 Mode HEPS can accommodate 1/2" and 3/4" conduit Input terminals support 12 to 18 AWG Use in conjunction with Hochiki's speaker or wall mount speaker/strobe (SOLD SEPARATELY) To synchronize, use the HAVSM control module Wire strip guide Xenon strobe maintains constant flash rate of or at 1Hz Available color(s): Ivory Temporal 4 520Hz measured per ANSI/UL 2075 Tamperproof re-entrant style grill and locking screw (optional use) Available color(s): Red or ivory HAVSM operates the HCS/HCC, HES3-24/HEC3-24, HES3-12/HEC3-12, HEC/HES/HEH, HSSPK Series and HX93 Series HAVS module comes with its own back box and cover plate Available color(s): Red or ivory 21

NOTIFICATION APPLIANCES B6-24 / B10-24 / BB-WP FIRE ALARM BELLS Available in 6" or 10" models High dba output Mounts to a standard 4" square electrical box ANSI/UL Listed for outdoor use when used with the BB-WP weatherproof back box 18 AWG wire leads Meets ANSI/UL 464 requirements Available color(s): Red WHE SERIES WEATHERPROOF EVACUATION SIGNALS Nominal voltage 24VDC Unit is shipped with WHES24-75 Candela Strobe or WHEC24-75 Candela Horn/Strobe Switch selection for high dba Switch for mechanical and 2400hz tone Switch for continuous tone Input terminals supports 12 to 18 gauge wire Tamperproof re-entrant grill Wide voltage range of 16-33 VDC or FWR Separate horn and strobe functions Synchronize strobe and/or horn by using HAVSM module Available color(s): Red or ivory HGOE-R / HGOE-W OUTDOOR ENCLOSURE Weatherproof seal Made of clear Lexan - providing maximum visibility and reliability for effective visible signaling UV stable polycarbonate lens Back box or side mount with mounting tabs Reinforcement steel hardware Textured plastic finish Available color(s): Red or ivory HCSB, HSB & HBLP SERIES BACK BOXES UL Listed Weatherproof seal Back box or side mount with mounting tabs Reinforcement steel hardware Textured plastic finish Available color(s): Red or ivory 22

SERVICE TEST EQUIPMENT SOLO 461 HEAT DETECTOR TESTER Cordless heat detector tester Battery powered -- no hanging wires/tangled cables Lightweight and simple to use Suits fixed temperature, rate-of-rise and combination detectors up to194 F/90 C Unique IR activation and Cross Air Technology (CAT ) for optimum energy use and results Transparent test cup for clear view of detector LED SOLO 330 AEROSOL DISPENSER Lightweight and simple to use Universal design suits wide range of detectors (up to 100mm / 4" in diameter) Spring-loaded solution for suspended ceilings Transparent test cup for clear view of detector LED Swing frame for use at / from angles SOLO 200 UNIVERSAL DETECTOR REMOVAL TOOL Compatible with all Hochiki conventional detectors and AnalogueUE sensors Universal design - suits most detectors and sensors of other manufacturers Color coded tri-grip heads are spring loaded Adjustable tri-grip Suitable for use on angled ceilings Lightweight TESTIFIRE MULTI-STIMULUS DETECTOR TESTER Smoke, heat and CO testing Multi or single-sensor tester Simultaneous, consecutive or single stimuli programmable testing modes Smoke and CO capsules instead of pressurized aerosols 23

SERVICE TEST EQUIPMENT NSRT SMOKE DETECTOR REMOVAL TOOL Combination removal tool/outer cover remover tool for ATG-EA, AIE-EA, ALG-V, ALK-V, SIJ-24 and SLR-24/-835 series sensors/detectors Available in hand-held (NSRT-H) or with 15-foot (NSRT-C) extension pole NSTT SMOKE DETECTOR TESTER Tester for Hochiki's SIJ-24 and SLR-24/-835 series smoke detector with a reed switch No combustion material needed No meter, batteries or screwdriver required Available in hand-held (NSTT-H) or with 15-foot (NSTT-C) extension pole TCH-B200 HAND-HELD PROGRAMMER Compact and easy to use Provides address setting and reading Can be used on both sensors and modules Has the diagnostic ability to display the sensor analogue value 24

CONVENTIONAL PANELS The HCA conventional panel is available in 2, 4, or 8 zones. The 4 and 8 zone models support releasing of agents and water. The HCA is supported by our full line of conventional devices. HCA CONVENTIONAL CONTROL PANEL ETL, CSFM Approved Fully programmable using simple menu options Installer friendly and supports flush or surface mount without a separate trim ring Built-in two-line (16 characters for each line) LCD display provides easy to read information 15 key control buttons for easy programming, reset and silencing Event history log (256 events) with date/time stamp, which can be viewed from LCD display 4 programmable supervised NAC outputs 6.5 Amp power supply Switchable 120/240VAC 50/60 Hz power supply 5 programmable output patterns for NAC circuits Gentex sync protocol built-in Supports releasing of agents & water on HCA-4 & HCA-8 models Three programmable general purpose relays Built-in Walk Test feature Supports up to two 12V, 18Ah backup batteries Supports one remote annunciator via RS-485 Available color(s): Red The HCP conventional panel is available with 8 zones and expandable to 64 zones. Our full complement of adder circuit modules, remote annunciators and digital communicators allow you to expand system requirements as needed. HCP-1008E CONVENTIONAL CONTROL PANEL 8 Class B initiating circuits which may be configured as 4 Class A circuits expandable up to 24 Class B or 12 Class A initiating circuits 4 Class A/B indicating circuits with individual trouble indicators (1.7 Amps max. per circuit) Each indicating circuit can be configured as Silenceable or Non-Silenceable Audibles may be configured as Steady, Temporal Code, California Code or March Time Each initiating circuit can be configured as Alarm, Supervisory, Waterflow or Trouble Two outputs for 4 wire resettable smoke power supply (200 ma max. each) Alarm verification on initiating circuits Easy configuration via push buttons and DIP switches on the front panel Available color(s): Red 25

CONVENTIONAL PANELS The HCVR-3 is a 3 zone conventional releasing fire alarm control panel and it is UL and FM approved for releasing. The HCVR-3 is fully programmable using simple menu options. The Panel is a single board construction, which provides easy replacement solution. Compatible with a wide range of detection devices. HCVR-3 CONVENTIONAL RELEASING FACP UL 864 and FM approved Three Zone Detection Any single zone or any combination of zones can be configured to release Fully programmable using simple menu options Simple, single board construction Installer friendly Compatible with wide range of detection devices Configurable first stage NAC delays Built-in Manual Release Switch and seperate circuit Available color(s): Red 26

CONVENTIONAL DETECTORS The SLR-835B series detectors offer the versatility of being used on either 12 or 24 volt systems. The direct wire installation terminals eliminate the need for a base. These detectors offer the same low profile design as our other models and come with or without a fixed thermal sensor. Our smoke detectors are available in ivory and/or white plastic (see descriptions below for specific color availability) and are electronically compatible with our current and previous smoke detector models. SLR-835 SLR-835B SLR-835H SLR-835BH SLR-835/SLR-835H PHOTOELECTRIC SMOKE DETECTOR UL Listed, FM Approved, CSFM Approved Low profile - only 1.8" high (2.2" 835H) 2 or 4 wire base compatibility, relay bases available 135 F latching heat sensor (835H only) Heat sensor protected by a built-in guard (835H only) Highly stable operation, RF/transient protection Two built-in power/sensitivity supervision/alarm LEDs Automatic sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 14, Inspection, Testing and Maintenance Available color(s): Ivory or white SLR-835B/SLR-835BH DIRECT WIRE PHOTOELECTRIC SMOKE DETECTOR UL Listed, FM Approved, CSFM Approved Low profile SLR-835B = 2.0" high, SLR-835BH = 2.375" high 135 F latching heat sensor (SLR-835BH) Highly stable operation, RF/transient protection Two built-in power/sensitivity supervision/alarm LEDs Non-directional smoke chamber Automatic sensitivity window verification function meets outlined equirements in NFPA 72, Chapter 14, Inspection, Testing and Maintenance Available color(s): Ivory or white NAC 1 Zone 1 NAC 2 Zone 2 NAC 3 Zone 3 NAC 4 Zone 4 AGENT INSTALLED ROOM Actuator Abort Switch Internal Horn/ Strobe External Lamp Detector 1 Detector 2 Common Alarm Manual Release SLR-24V PHOTOELECTRIC SMOKE DETECTOR UL Listed, FM Approved, CSFM Approved Low profile, 1.8" high (with base) 2 or 4 wire base compatibility, relay bases available Highly stable operation, RF/transient protection Low standby current, 45μA at 24VDC Two built-in power/sensitivity supervision/alarm LEDs Non-directional smoke chamber Built-in magnetic go/no-go detector test feature Automatic sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 14, Inspection, Testing and Maintenance Available color(s): Ivory or white 27

CONVENTIONAL DETECTORS SLR-24H PHOTOELECTRIC SMOKE DETECTOR UL Listed, FM Approved, CSFM Approved Low profile, 2.2" high (with base) 2 or 4 wire base compatibility, relay bases available 135 F fixed temperature heat sensor (latching) Heat sensor protected by a built-in guard Highly stable operation, RF/transient protection Low standby current, 45μA at 24VDC Two built-in power/sensitivity supervision/alarm LEDs Non-directional smoke chamber Automatic sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 14, Inspection, Testing and Maintenance Available color(s): Ivory or white The SOC-24V, SLV-24M, SLV-24N, and SLV-24V can be used in all areas where photoelectric smoke detectors are required. The patented smoke chamber makes them well suited for fires ranging from smoldering to flaming. SOC-24V PHOTOELECTRIC SMOKE DETECTOR Removable, High Performance Chamber Automatic Sensitivity Window Verification (ASWV) - Drift Compensation Technology Remote Indicator output Wide voltage range (9.5 ~ 30 Vdc) Low profile design with one piece outer cover Single fire LEDs allow 360 viewing Range of mounting bases SLV-24M MARINE PHOTOELECTRIC SMOKE DETECTOR Low profile - only 2.00" high, including base Highly stable operation, RF/transient protection Low standby current, 45μA at 24VDC Two built-in power/alarm LEDs confirm detector status (360 o viewing) Non-directional smoke chamber Built-in magnetic go/no-go detector test feature Removable smoke labyrinth for cleaning or replacement Available color(s): Ivory 28 69

CONVENTIONAL DETECTORS SLV-24N PHOTOELECTRIC SMOKE DETECTOR UL Listed, FM Approved, CSFM Approved Low profile - only 2.00" high, including base 2 or 4 wire base compatibility, relay bases available Highly stable operation, RF/transient protection Low standby current, 45μA at 24VDC Two built-in power/alarm LEDs confirm detector status (360 o viewing) Non-directional smoke chamber SLV-24V PHOTOELECTRIC SMOKE DETECTOR UL Listed, FM Approved, CSFM Approved Low profile - only 2.00" high, including base 2 or 4 wire base compatibility, relay bases available Highly stable operation, RF/transient protection Low standby current, 45μA at 24VDC Two built-in power/alarm LEDs confirm detector status (360 o viewing) Non-directional smoke chamber Vandal resistant security locking feature Removable smoke labyrinth for cleaning or replacement Compatible with SIJ-24 ionization detectors Backwards compatible with Hochiki SLK and SIH detectors Highly resistant to false alarms caused by steam Available color(s): Ivory or white Vandal resistant security locking feature Built-in magnetic go/no-go detector test feature Removable smoke labyrinth for cleaning or replacement Compatible with SIJ-24 ionization detectors Backwards compatible with Hochiki SLK/SLR-24V and SIH detectors Highly resistant to false alarms caused by steam Available color(s): Ivory 29

CONVENTIONAL DETECTORS The DCD, DFE, and DSC models provide heat detection for various applications. Each offers a choice of either fixed or rate of rise detection options. The DCD and DFE models are available in 135 F or 190 F alarm thresholds. DCD-135 / 190 FIXED TEMPERATURE AND RATE OF RISE HEAT DETECTOR UL Listed, FM Approved, CSFM Approved Available models: 135 F fixed temperature/rate of rise (DCD-135) or 190 F fixed temperature/rate of rise (DCD-190) UL Listed spacing up to 60 feet by 60 feet 2 or 4 wire base compatibility, relay bases available Highly stable operation, RF/transient protection (reduces false alarms) Two built-in power/alarm LEDs confirm detector status (360 viewing) Compatible with Hochiki's SLR-24V and SIJ-24 detectors and bases Available color(s): Ivory or white DFE-135 / 190 FIXED TEMPERATURE HEAT DETECTOR Available models: 135 F fixed temperature (DFE-135) or 190 F fixed temperature (DFE-190) UL Listed ceiling spacing of 50 feet by 50 feet Self-restoring Contact rating of 100mA Latching LED base available Available color(s): Ivory or white DSC-EA RATE OF RISE HEAT DETECTOR Ideal for locations where temperature is likely to increase suddenly in the event of fire Slim design provides an economical solution for heat detection Latching LED base available Available color(s): Ivory 30 69

CONVENTIONAL BASES The conventional bases come in 4" or 6" diameter, and are available with or without a current limiting resistor (depending upon control panel requirements). Bases are available in ivory or white to match the detector. Ivory is the standard color for detectors and bases for most applications. SPECIAL APPLICATIONS HSC-220R HSC-221R HSC-224R HSC-4R HSC-224L HSC-220L HSC-221L Relay base (88mA) Relay base (49mA) Relay base (43mA) 4 wire 24 volt base (43mA) Latching LED base (35-42mA) Latching LED base (67-80mA) Latching LED base (37-45mA) STANDARD TYPES NS4-100, NS6-100 NS4-220, NS6-220 NS4-221, NS6-221 NS4-224, NS6-224 Non current limited 93mA current limit 46mA current limit 43mA current limit 31

BEAM DETECTION FireOPTIX-50M/100M REFLECTIVE OPTICAL BEAM SMOKE DETECTORS Easy set up and alignment Single compact housing Calibrated obscuration test filter included Microprocessor controlled Alarm latching or auto reset FireOPTIX-50MA MOTORIZED REFLECTIVE OPTICAL BEAM SMOKE DETECTOR Up to 2 Detector Heads reporting to One Ground Level Controller Range of 50M (26.2 ft. to 164 ft.) / (8m to 50m)* Built in Laser assisted prism mounting Auto-Alignment 2 to 4 minutes per head AutOptimise: Auto-Correction due to building shift Built-in electronic UL/ULC/FM obscuration-acceptance fire test Contamination compensation Separate Trouble and Alarm relays for each of the 2 channels Automatic gain control 12 VDC or 24 VDC operation Separate alarm and trouble contacts Remote Test Station available Password protected settings Low current draw 5 to 8.5mA Built-in 1/2 /M-20 conduit knock-outs on the system controller Programmable alarm thresholds: 10% - 60% in 1% increments Programmable Fault and Alarm delay: 2-30 Seconds Logs the 50 most recent events per detector *For throws of 100M (164 ft. to 328 ft.) / (50m to 100m) Requires FireOPTIX LR Kit Par t#0200-08190 32 69

ADDITIONAL CONVENTIONAL PRODUCTS DH-98 SERIES CONVENTIONAL DUCT DETECTOR Detects and controls the spread of smoke throughout the building HVAC ducts Compatible with building automation and fire alarm systems Installs quickly and easily Interchangeable plug-in detector heads No screens or filters to clean SPC-24 PROJECTED BEAM SMOKE DETECTOR UL Listed, FM Approved, CSFM Approved Microprocessor based for reliability Simple setup and alignment with signal strength LEDs Provides 60 feet on center linear protection at a range of 32.8 feet to 328 feet Automatic compensation for signal drift or dirty lens Three field adjustable sensitivity settings Form A alarm and Form B trouble contacts Calibrated filters available to verify sensitivity Color-coded emitter (red) and receiver (green) labels for easy recognition HPS-DAK-SR MANUAL PULL STATION FOR FIRE SUPPRESSION RELEASE UL Listed, CSFM Listed Metal construction Enclosed switch with glass rod (included) Cover provides magnet window and placement guide for go / no-go operational testing without disassembly (conventional only) Durable steel back box with clear cover UL Listed accessories: remote power, remote alarm indication capability and remote horn / piezo capability Photoelectric (both), and high voltage (conventional only) models HPS-SAH, HPS-SAK, HPS-DAH, HPS-DAH/S, HPS-DAK, HPS-DAK/S SERIES MANUAL NON-CODED PULL STATIONS UL Listed, CSFM Listed Metal construction Enclosed switch with glass rod (included) 10 Amps @ 120 VAC Available in: Single Action, Dual Action and Dual Action in Spanish (HPS-DAH/S) 33

ADDITIONAL CONVENTIONAL PRODUCTS HPS-DAK-WP WEATHERPROOF MANUAL PULL STATION Weatherproof manual pull station 10 A, 120 VAC contacts Rugged die-cast aluminum housing Neoprene sealing gasket Corrosion-resistant construction HPS-SA-EX/WP EXPLOSION PROOF MANUAL PULL STATION Compatible with all Hochiki control panels Rugged die-cast housing Rated class I group B (hydrogen) C&D, class II groups E, F, G, class III, 4X outdoor Corrosion-resistant construction Lift and latching pull-down lever Enclosed switch with glass rod (Included) Screw terminal connections Key reset Latching alarm levers Screw terminals 12-22 AWG Key-locked reset Optional glass break rod DPDT contacts HPS-SAH-WP WEATHERPROOF MANUAL PULL STATION Weatherproof manual pull station 10 A, 120 VAC contacts Rugged die-cast aluminum housing Neoprene sealing gasket Corrosion-resistant construction Latching pull-down lever Screw terminal connections Hex reset English Spainish HPS-CP CALL POINT BREAK GLASS STATION Actuating switch, a heavy duty plunger type Glass plate (2.5" x 2.5"), a Factrolite TM single strength (obscured) type Steel rod attached Mounts in a standard electrical outlet box 34

ADDITIONAL CONVENTIONAL PRODUCTS PB-SA SYSTEM ABORT PUSH BUTTON Protection against accidental activation Stainless steel backplate Polycarbonate is UV-stabilized ADA compliant Key reset 35

INDEX ACC-V 12 FIRE ALARM SYSTEMS DIAGRAM 4-5 FNV-WS 19 HSB-NSA-6 13 ALN-V 12 FIRENET 6 FN-XXX-ULADA 17 HSSPKCLP SERIES 20 ASB 13 FIRENET GRAPHIX SOFTWARE 8 FN-XXX-ULX 17 HSSPKWLP SERIES 20 ASBL 13 FIRENET PLUS 6 FRCME-P 15 NSRT 24 ATJ-EA 12 FIRENET VAPOR - VPR - 1 9 HAVSM 21 NSTT 24 B6-24/B10-24/BB-WP 22 FIRENET VAPOR - VPR - 15 9 HC SERIES 20 PB-SA 35 DCD-135/190 30 FIRENET VAPOR - VPR - 1P 9 HCA 25 PE-XXSN 17 DCP-AMS SERIES 15 FIRENET VAPOR - VPR-4 & VPR-6 9 HCP-1008E 25 SCI-B4 & SCI-B6 13 DCP-CZM 14 FireOPTIX - 50 M / 100 M 32 HCSB, HSB & HBLP SERIES 22 SLV-24 28 DCP-DIMM 14 FireOPTIX- 50 MA HCVR-3 26 SLR-24H 28 DCP-FN-CTM 14 FN-4127-IO 10 HE SERIES 20 SLR-24V 27 DCP-FRCMA & DCP-FRCMA-I 14 FN-4127-NIC 10 HEP & HEPS SERIES 21 SLR-835/SLR-835H 27 DCP-FRCME-M 15 FN-4127-SLC (FireNET) 10 HGOE-R / HGOE-W 22 SLR-835B/SLR-835BH 27 DCP-R2ML 14 FN-ACC-R/C 8 HHLF SERIES 21 SOC-24V 28 DCP-R2ML-I 14 FN-DAC (FireNET) 11 HX93 SERIES 21 SLV-24M 28 DCP-R2MH 14 FN-LCD-N 7 HPS-CP 34 SLV-24N 29 DCP-R2MH-I 14 FN-LCD-S 6 HPS-DAH 33 SLV-24V 29 DCP-SCI 14 FNP-1127-SLC (FireNET Plus) 10 HPS-DAH/S 33 SOLO 200 23 DCP-SOM-A & DCP-SOM-AI 14 FNP-LED 7 HPS-DAK 33 SOLO 330 23 DCP-SOM-R 14 FN-P187 16 HPS-DAK/S SERIES 33 SOLO 461 23 DFE-135 /190 30 FN-V187 16 HPS-DAK-SR 33 SPC-24 32 DH-98 SERIES 34 FNV-FH 18 HPS-DAK-WP 34 TCF-142-M-ST 15 DH-99 SERIES 16 FNV-FJ 18 HPS-SA-EX/WP 34 TCH-B200 24 DSC-EA 30 FNV-FS 19 HPS-SAH 33 TESTFIRE 23 EMS GRAPHIX SOFTARE 8 FNV-MP & FNV-DP 18 HPS-SAH-WP 34 WHE SERIES 22 EVAX 19 FNV-TC 18 HPS-SAK 33 X187/S187 16 35

Your Safety, Our Technology HOCHIKI EUROPE (UK) LIMITED Grosvenor Road, Gillingham Business Park, Gillingham, Kent, ME8 0SA, United Kingdom Telephone: +44 (0)1634 260133 Facsimile: +44 (0)1634 260132 info@hochikieurope.com www.hochikieurope.com 9-5-0-591/ISS3/JAN18