Fan heater Panther WALL MOUNTED FAN HEATER

Similar documents
Fan heater Panther Powerful fan heater for large premises

Fan heater Panther 6-15 Efficient fan heater for medium size premises

Original instructions. Panther 6-15 kw

Thermocassette HP RADIANT HEAT CASSETTES FOR CEILING MOUNTING

Industrial infrared heater IR For premises with large volumes and high ceilings

Elztrip EZ100 Single panel radiant heater for offices, shops etc.

Elztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications

Industrial infrared heater IR

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

Thermozone AC 300/WAC 300

Fan heater SWT Ceiling mounted fan heater with water heat

Thermozone ADR 200/300 E/W

Thermozone SF. Air curtains for vertical mounting in curved doorways

Original instructions AR

Thermozone RD. Air curtains for revolving doors

Carbon infrared heater IHC

Thermostats. Type Voltage Max. current Setting range Protection class HxWxD breakpoint [V] [A] [ C] [mm] RTEV C IP30 71x71x28

Thermozone AD Corinte

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating

Comfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings!

Radiant heaters - Offices, shops and public premises

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings!

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

Energy-efficient heat source provides comfort in large rooms

COR Series AIR CURTAINS. Air curtains. Dimensions (mm) Accessories. Technical characteristics

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

HEATXL RVS. Electric Infrared Heater

FLIGHT TYPE DISHWASHER

GAS AIR HEATER RANGE

8/S1 AIR CURTAINS SONATA, SONATA-V. v 1.0 (en)

THERMASREG TR 040 THERMASREG TR 060

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Mini Catalogue air curtains radiant heaters fan heaters convectors controls

Original instructions. Infrared heater IRCF...17

Brasch Hazardous Location Unit Heaters

Air curtains. For a comfortable indoor climate

PANTHER. Condensate removal pump Installation and operating guide

Explosion-Proof Forced Air Unit Heater - XGB

Your model: Your service centre: Operating Instructions for deep fat fryers

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

Save energy. ARGUS presence detectors

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Explosion-Proof Forced Air Unit Heater - XGB

CR1 Series Triton Corrosion Resistant Washdown Heaters

HD3D Forced-Air Heater

Air curtains. For a comfortable indoor climate

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Technical Information HXV - HRV Ventilation

Series A28 Two stage Thermostats. Feature and Benefits

Installation, operation and maintenance guide for window models

Instruction Manual WARNINGS

ROBUST Electric fan heaters for demanding environments

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

Gas heaters and convectors ROBUR

CASSETTE UNIT. Comfort Circle

Manual / Handbuch Spare parts list / Ersatzteilliste

EKA / EKA NV / EKA NI / EKA NIS

CAW Ceiling-mounted fan heaters for hot water

Original instructions. Thermoplus PL RU

Installation & Operating Instructions IMage Pool Control Type

Recessed. Air Curtain. Fig 1. Recessed air curtain

240 Series Unit Heater SameDay Shipping

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Industrial Air Heaters

EKS EKS NI EKS NIS EKS NV EKS NV PH EKS NV PTC/PS

Original instructions SWX C/D NO DE ES... 26

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

MARVAIR MODPAC II AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

NEW RANGE OF WARM AIR CURTAINS

AC25. Art.nr:

commercial & industrial electric space heating equipment & controls Electrical Wholesaler Product Guide Valid from 1st February 2011

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

CX1 ProVector Explosion-Proof Heaters

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

1. Basic safety information 3 2. Proper use 3

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Heat recovery unit RDKS

CDP 40 SWIMMING POOL DEHUMIDIFIER

4 1 Heating. wooden floors or renovated floors.

Cassette units Model Comfort Circle. - heating - cooling - ventilation

WOLF VENTILATION SYSTEM PRICE LIST

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

ENERGY TOP. Condensing boiler solutions

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

VEX100 series Air handling units with cross-flow heat exchanger

STR-600 Impact Dryer

VFL, VFLPG, VTL and VRA Rectangular electric duct heaters

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

State problem and/or comments:

Air Heating: Portable... 3 Stationary mounting... 6 Gate/door (air curtains)... 8

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Caution: The fans must not be used in bath or shower enclosures.

Technology for life. Unit heater LH

Transcription:

Electrical heat 6 30 Fan heater WALL MOUNTED FAN HEATER 8 models is a range of silent and efficient fan heaters for fixed installation. is available in two sizes with different outputs. 6 15 is designed for heating, drying and ventilation of workshops, sport centres, shops, assembly halls and drying rooms etc. Built-in thermostat is included on delivery and output and fan speed can be set on the control panel (accessory). One control panel can control several units. Master/slave function. 20 30 is designed for heating, drying and ventilation of large areas, for example industrial uses. The temperature is regulated by a thermostat (accessory). Time delay relay provides a gradual increase of the output. Equipped with over-run thermostat for efficient cooling. Output and fan speed can be set on the control panel (accessory). One control panel can control several units. Master/slave function. is delivered with adjustable wall mounting brackets which allow the air flow to be directed. Indication lamp Corrosion proof casing of hot zinc-plated and powder lacquered steel panels. Colour: RAL 9016 Adjustable wall mounting brackets allow the air flow to be directed downwards and sidewards Built-in thermostat with setting range +5 +35 o C ( 6 15 ) Manual reset for overheat protection Over-run thermostat for efficient cooling ( 20 30 ) 78

is available with outputs suitable for buildings ranging from small shops to large industrial buildings. Fan heaters Fan heater is a range of powerful and silent fan heaters suitable for tough environments as well as in areas with a demand for low noise level. Mixing cabinets combine heating and ventilation. The mixing cabinet saves energy by mixing return air with fresh air in individually preset proportions. is delivered with adjustable wall mounting brackets which make it possible to direct the air flow for optimal effect and comfort. It is recommended to supplement fan heater with ceiling fan ICF in buildings with high ceilings. A combination that gives the best comfort and economy! 79

TECHNICAL SPECIFICATIONS Fan heater, 6 15 Type Output stages Air flow Sound level* 1 t* 2 Voltage Amperage HxWxD Weight [] [m 3 /h] [db(a)] [ o C] [V] [A] [mm] [kg] SE06 0/3/6 900/1300 39/47 20/14 400V3N~ 8.7 520x450x510 21 SE09 0/4,5/9 900/1300 39/47 30/21 400V3N~ 13 520x450x510 22 SE12 0/6/12 900/1300 39/47 40/28 400V3N~ 17.3 520x450x510 22 SE15 0/7.5/15 900/1300 39/47 50/35 400V3N~ 21.7 520x450x510 22 SE135 0/5/10 900/1300 39/47 34/23 440V3~ 13.4 520x450x510 23 (convertible) 0/7/13.5 45/31 500V3~ 15.6 * 1 ) Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent absorption area: 200 m 2. * 2 ) t = temperature rise of passing air at maximum heat output at lowest/highest air flow. Protection class, 6 15 : (IP44), splash-proof design. Approved by SEMKO and CE compliant. Fan heater, 20 30 Type Output stages Air flow Sound level* 1 t* 2 Voltage Amperage HxWxD Weight [] [m 3 /h] [db(a)] [ o C] [V] [A] [mm] [kg] SE20 0/10/20 1900/2600 52/60 31/23 400V3N~ 29.5 576x478x545 27 SE30 0/10/20/30 1900/2600 52/60 47/34 400V3N~ 43.9 576x478x545 31 SE305 0/7.5/15/23 1900/2600 52/60 36/26 440V3~ 30.8 576x478x545 32 (convertible) 0/10/20/30 47/34 500V3~ 35.1 * 1 ) Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent absorption area: 200 m 2. * 2 ) t = temperature rise of passing air at maximum heat output at lowest/highest air flow. Protection class 20 30 : (IP44), splash-proof design. Approved by SEMKO and CE compliant. DIMENSIONS, 6 15 100 Ø7 520 90 Ø6,5 Ø14 450 510 478, 20 30 576 545 80

Mixing cabinet, PBS01/02 D G B C E F A Type A B C D E F G [mm] [mm] [mm] [mm] [mm] [mm] [mm] PBS01 660 430 365 420 445 445 420 PBS02 890 520 420 520 560 570 540 POSITIONING, MOUNTING AND INSTALLATION Mounting is wall mounted with an adjustable wall mounting bracket which allows the air flow to be directed downwards and sideways. must not be mounted on the ceiling. For minimum mounting distance, see Fig. 1. Mounting with mixing cabinet PBS01 is suitable for 6 15 and PBS02 is suitable for 20 30. The mixing cabinet is available as an accessory and consists of an outer wall grille and an internal wall frame. The internal wall frame and outer wall grille are built into the wall or screwed on to the wall. The hole in the wall should be 370x395 mm (WxH) for PBS01 and 480x510 mm (WxH) for PBS02. The mixing cabinet is assembled on the screws of the wall frame and locked. The cabinet is also screwed on to the wall. The heater is screwed on to the mixing cabinet. A control lever can be ordered separately and consists of a fixture arm, a mounting bracket, ball and two adherent joints. A rod (not included) with an 8 mm diameter is needed. See Fig. 2. The mixing cabinet can also be equipped with a separate damper motor or PSA01, automatic damperand temperature regulator. Connection is intended for permanent installation. SE135 and SE305 are convertible between 440V3~ and 500V3~. See wiring diagrams on pages 84-87. Fan heaters Wall Ceiling 30º min 300 min 300 Wall 7,5 min 1000 15 min 1800 Fig. 1: Minimum distance for permanent installation. Fig. 2: Cutaway view of with mixing cabinet. 81

REGULATION ALTERNATIVES Fan speed and thermostat regulation 6 15 is supplied with built-in thermostat (+5 +35 o C). Required output can be set via the controlpanel, 0-1/2-1/1 as well as fan speed, 0-1-2-3. Up to 6 units units can be controlled from the same control panel. Complete regulation kit: PP15, control panel, regulates the output in two stages and the air flow in three stages 20 30 is regulated with an external thermostat, time delay relay provides a gradual increase of the output. Required output can be set via the controlpanel (0-1/2-1/1 for SE20 and 0-1/3-2/3-1/1 for SE30-SE305) as well as fan speed 0-1-2. Up to 6 units can be controlled from the same control panel. Complete regulation kit:, 2-stage capillary tube thermostat or RTI2, electronic 2-stage thermostat PP20, control panel, regulates the output in two stages and air flow in two stages (SE20) or PP30, control panel, regulates the output in three stages and air flow in two stages (SE30, SE305) Automatic temperature regulator The heat can be decreased according to demand, for example at night or weekends. Switches between day and night mode. Complete regulation kit: PTA01, automatic temperature regulator Regulation of mixing cabinet The mixing cabinet combines heating and ventilation by mixing return air with fresh air in appropriate proportions. Damper regulator is ordered separately. Complete regulation kit: PHR01, control lever, manual damper regulator or PSA01, automatic damper- and temperature regulator PSM01, damper motor, is used in combination with PSA01 when several mixing cabinets should be controlled ACCESSORIES RTI2 PP15/20/30 PTA01 PSA01, 2-stage capillary tube thermostat Possible to adjust the temperature difference between the stages (1 4 o C), setting range of 0 +40 o C. Required connection voltage: 230/400V (two volt free contacts). Protection class: IP55. RTI2, electronic 2-stage thermostat Possible to adjust the temperature difference between the stages (1 10 o C), setting range of +5 +35 o C. Required connection voltage: 230V (two volt free contacts). Protection class: IP44. PP15/20/30, control panel The desired output and fan speed can be set on the control panel. Up to 6 units can be controlled by one control panel. Protection class: IP44. PTA01, automatic temperature regulator PTA01 can be used to lower the heat when necessary (1 10 o C), for example at night or weekends. The regulator consists of an electronic timer and thermostat with an external sensor. The timer alternates between day and night mode. Protection class: IP55. PBS01/02, mixing cabinet Saves energy by mixing return air with fresh air in preset proportions. The mixing cabinet is delivered with a wall frame and outer wall grille. PSA01, automatic damper and temp. regulator Lowers the temperature and reduces the air intake when the demand is lower. Consists of timer and thermostat with sensor, potentiometer and damper motor. If an exhaust fan is used, it can also be controlled with PSA01. Protection class: IP55. 82

FEVK01 TIM120/240 ICF440 PHR01, control lever Manual damper regulation of the mixing cabinet. PSM01, damper motor Used in combination with PSA01 when several mixing cabinets should be controlled. (1 damper motor is included in PSA01.) Protection class: IP54. PLR 15/30, air director The air director directs the air flow vertically or laterally. PLR is snapped on the front of the heater. Torsional (turning) angle 0 35 o. PFF 15/30 exhaust air fan Can be used with fan heater/mixing cabinet to obtain good ventilation. Air flow approx. 1400 m³/h or 2600 m³/h. Protection class: IP54. PTRP, drying room kit Consists of exhaust air fan, thermostat and timer. The exhaust air fan works alternately with for example a fan heater for shortest possible drying time and minimal energy consumption. The complete kit includes fan heater with output 6 12. FEVK01, load guard The load guard limits the addition of output so that the current does not exceed the rated value of the main fuse, in that case it disconnects a chosen section. With built-in contactor. Three current transformers 16 35 A are included. Maximum load that can be disconnected is 11 (16A). FEV01 and an external contactor which can take larger loads is used when the load is larger than 11. Protection class: IP44. FEVS02, current transformer 33 145 A, complementary to load guard FEVK01. 3 pieces. TIM120/240, timer Mechanical timer for 2 and 4 hours respectively. Enclosed design for external mounting. Disconnects the heater when the preset time has expired. Protection class: IP44. ICF440, ceiling fan Ceiling fans provide large savings when the ceiling height is above 4.5 metres. Read more on page 114-117. Protection class: IP44. Fan heaters For further alternatives, see section on Thermostats and regulators. Type Description HxWxD [mm] 2-stage capillary tube thermostat 165x60x57 RTI2 Electronic 2-stage thermostat 155x87x43 PP15 Control panel for SE06 SE15 160x120x96 PP20 Control panel for SE20 160x120x96 PP30 Control panel for SE30 and SE305 160x120x96 PTA01 Automatic temperature regulator 185x215x115 PBS01 Mixing cabinet for SE06 SE15 see page 81 PBS02 Mixing cabinet for SE20, SE30 and SE305 see page 81 PSA01 Automatic damper and temperature regulator 305x215x115 PHR01 Control lever PSM01 Damper motor 180x100x70 PLR15 Air director for SE06 SE15 355x355x60 PLR30 Air director for SE20, SE30 and SE305 415x445x60 PFF15 PFF30 PTRP PTRP06 PTRP09 PTRP12 Exhaust air fan for SE06 SE15 Exhaust air fan for SE20, SE30 and SE305 Drying room kit without fan heater Drying room kit with fan heater SE06 Drying room kit with fan heater SE09 Drying room kit with fan heater SE12 FEVK01 Load guard 16-35A 82x195x155 FEVS02 Current transformer 33-145A (3 pieces) TIM120 Timer 2 hours 80x75x70 TIM240 Timer 4 hours 80x75x70 ICF440 Ceiling fan 465x1400 (HxØ) 83

WIRING DIAGRAMS PANTHER 6 15 KW Manual 3-stage fan speed regulation and output limitation in stages 0-1/2-1/1 via control panel PP15. L 1 L L L L L 3 1 3 230V 440V 500V K1 K2 L 3 440V 3~ K2 SE 06 400V3~ K1 K2 6,3A º 1 2 3 N 1 8 1213 L 1 L L L L L 3 1 3 400V 3N~ K1 K2 1 10 6-15 X 3 4 X 1 2 PP15 1 ½ SE 09-15 400V3~ PP15, control panel K2 3 N 230V3~ 230V3~ 84

Wiring of accessories to 6-15. WIRING DIAGRAMS PANTHER 6 15 KW 6-15 P 1 P 2 12 TIM120, 240 1 2 3 Lo Hi 1 2 3 Diff (1-4)K 321 KRT(V)1900 (0-40 ) Utan tillbehör / Without accessories PP15, control panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 6 Full fläkt / Full fan speed Hel effekt / Max. heat output KRT1900, capillary tube thermostat 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 6 Fan heaters 8+ PP15 1 2 3 4 5 6 7 8 910 PP15 2-stage capillary tube thermostat 1 2 3 4 5 6 7 8 9 10 11121314 1516 1 2 3 4 5 6 7 8 9 10 11121314 1516 KRT 1900 6 TIM120/240, timer KRT1900 1 2 3 2+ 2+ 9+ TIM120/240 P1 P2 1 2 TIM PP15 PP15 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 9 1011121314 1516 6 1 2 3 4 5 6 7 8 9 1011121314 1516 7+ PP15 1 2 3 4 5 6 7 8 910 4+ KRT 2800 PP15 1 2 3 1 2 3 85

WIRING DIAGRAMS PANTHER 20 KW Manual 2-stage fan speed regulation and output limitation in stages 0-1/2-1/1 via control panel PP20 and external thermostat. Slave connection. Timer connection. SE20 M 20 6,3A 6,3A SE20 L1 L2L 3N 1 2 3 4 5 6 7 8 9101112 1 2 3 4 5 6 7 8 9101112 PP20, control panel 400V 3N~ 123456789 123 PP20 KRT1900 KRT1900, capillary tube thermostat SE20 1 2 3 4 5 6 7 8 9101112 2-stage capillary tube thermostat SE20 1 2 3 4 5 6 7 8 9101112 TIM120, timer P P 12 1 2 123456789 123 123 Diff (1-4)K Hi Lo TIM PP20 86

WIRING DIAGRAMS PANTHER 30 KW Manual 2-stage fan speed regulation and output limitation in stages 0-1/3-2/3-1/1 via control panel PP30 and external thermostat. Slave connection. Timer connection. 230V M 30 440V 500V L 1 LL 2 3 440V 3~ 500V 3~ 6,3A 6,3A SE30 SE30 L1 L2L 3N 1 2 3 4 5 6 7 8 9101112 1 2 3 4 5 6 7 8 9101112 PP30, control panel 400V 3N~ 123456789 123 PP30 KRT1900 Fan heaters KRT1900, capillary tube thermostat SE30 2 3 4 5 6 7 8 9101112 1 SE30 2 3 4 5 6 7 8 9101112 1 2-stage capillary tube thermostat P P 12 1 2 123456789 123 123 Hi Diff (1-4)K Lo TIM120 PP30 TIM120, timer 87