Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

Similar documents
Model RS72. Model RSCS280A. Model RSM2680

GERMICIDAL ULTRAVIOLET FIXTURES

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

ULTRAVIOLET PORTABLE AREA SANITIZER

Model D24-1S. Model D24-2S

GERMICIDAL ULTRAVIOLET IRRADIATORS

ULTRAVIOLET INDIRECT AIR DISINFECTION

ULTRAVIOLET SANITARY CONDIT IONERS

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

Document No C Revised January Atlantic Ultraviolet Corporation

NO4G, NO4GS, NO6G, NO6GS

Models 2B-SC, 3B-SC, 4B-SC, 4B-ASC, 5B-SC, 5B-ASC, 6B-SC, 6B-ASC. Models 2B-SC, 3B-SC. Models 6B-ASC. Installation, Operation & Maintenance

7-ASC / 8-ASC / 9-ASC

Document No A9 Revised August Atlantic Ultraviolet Corporation

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Document No B Revised June Atlantic Ultraviolet Corporation

Owner s Manual. Installation, Operation & Maintenance. Models B B B3 RoHS

Document No A3 Revised February Atlantic Ultraviolet Corporation

Owner s Manual. Installation, Operation & Maintenance. Model G48HO Remote Controlled Sanitizer

Document No A1 Revised September Atlantic Ultraviolet Corporation

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

Document No B1 February Atlantic Ultraviolet Corporation

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Ultraviolet Air Disinfection Equipment

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

Purifying air at the. Light. speed of. Carrier Corporation 2007 is a member of the United Technologies Corporation family, stock symbol UTX.

INTERNATIONAL OZONE TECHNOLOGIES GROUP, INC.

AMERICAN AIR & WATER, INC.

GRU-V Air Purifier. Product Manual

CA3500, BA3500, CH3500 New Comfort

S17A, S23A, S37C & S50C

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions.

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

ULTRAVIOLET WATER PURIFIERS

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

Operation Manual for Eco-Logic Pond & Lake Restoration System

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

A measured step forward

UVC in the Operating Room.

AIR PURIFIER CLASSIC INSTRUCTION MANUAL. CAUTION: Read manual carefully for correct procedures and proper operation.

1020 Industrial Drive, Orlinda, TN fax

ULTRAVIOLET WATER PURIFIERS

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

PURPOSE OF THE PROCEDURE

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

ULTRA-VIOLET STERILIZATION

Air Purification Unit MODEL 300/RHO2 USER GUIDE. Because You Care, Clean the Air

Ballast MIN A

Model LA-2SP. Air Purification Unit. User Guide. Bring Freshness Indoors

Ozone Generator Air Purifier HE-500/O3

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

Infrared Heaters For Controlled Concentrated Curing

PURION UV plants for disinfection

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

healthy comfort Indoor Air Quality Solutions

by Owner s Manual For use with model: AA250 For safety and to ensure proper use carefully read the contents of this manual before operating the unit.

RS4 Whole House IAQ System

PCO/UV N-Duct Model. Owner s Guide

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

ACCELERATE YOUR CURING TIME

OZONE AIR TREATMENT SYSTEMS

Document No E1 Revised February Atlantic Ultraviolet Corporation

Loctite Zeta 7600 Ultraviolet Curing Conveyor Part Number EQUIPMENT Operation Manual

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

EQUIPMENT OPERATION MANUAL. Loctite High Intensity Ultraviolet Source

Owner s Manual. Installation, Operation & Maintenance. Models S17A, S23A, S37C & S50C U LTRAVIOLET WATER PURIFIERS

HEPA/UV3 Sterilizing PCR Workstation and Cabinet

Owner s Manual. Installation, Operation & Maintenance. Models S2400C, S5000C, S15000C, S20000C & S25,000C High Capacity Systems

Perfect Air Purifiers

or

Ultraviolet PCR Cabinets and Workstations

Healthy, clean air for your home

Clean Air Optima HEPA UV ionizer air purifier CA-508

healthy comfort Indoor Air Quality Solutions

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects?

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 0905 FAOM15_0905

254 Nanometer Germicidal UV Disinfection Systems

UVP, Inc. Ultra-Violet Products Ltd., Unit W 11th Street, Upland, CA Trinity Hall Farm Estate, Nuffield Road

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

AO Product Sheet By Air Oasis. Air Oasis, LLP 3401 Airway Blvd Amarillo Tx 79118

Instruction Manual E4 ChamberIR Heater

Reduces common odors. 685mm tall x 140mm width x 226mm dia. Base 4.5kgs. Living room, Bedroom, Hospital recovery room, ICU / OT

Safety Manual Section 15 Radiation Safety

Liquid Storage Tank Conditioners

PureAir Air Purification System PCO-12C/20C

ENGLISH AIR160 AIR PURIFIER

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Introducing the most technically advanced indoor air treatment system

Add the Power of Indigo-Clean Disinfecting Technology to your Facility Lighting

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

Supplement 3: Engineering Controls

IMPORTANT INSTRUCTIONS READ & SAVE

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

Kitchen Exhaust Air Cleaning Systems

AIR PURIFIER OZONE GENERATOR

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

Transcription:

Model 2-OZ, 3-OZ free standing, wall, or ceiling mount Model 6-OZ free standing, wall, or ceiling mount

ABOUT US GERMICIDAL ULTRAVIOLET Since 1963, Atlantic Ultraviolet Corporation has pioneered the discovery and development of beneficial uses of ultraviolet energy. Over the years these efforts have led to the development of valuable, cost effective and environmentally sound techniques and products now known and respected throughout the world. Ozone (O 3 ) is a highly reactive form of oxygen that is useful as a deodorizer and a cleaning agent. Ultraviolet wavelengths shorter than 200 nanometers are capable of producing ozone from Oxygen (O 2 ) in the air. STER-L-RAY ozone lamps, in addition to emitting germicidal ultraviolet output at 254 nanometer wavelength, also emit ozone producing rays at 185 nanometer wavelength. Ultraviolet is a unique and rapid method of disinfection. It utilizes germicidal ultraviolet lamps producing short-wave radiation at 254 nanometers (nm) a wavelength highly lethal to bacteria, virus, and other microorganisms. An ever growing range of industries and consumer applications have found ultraviolet to be the ideal solution for their air treatment needs. Atlantic Ultraviolet Corporation equipment and systems are manufactured in the USA. The UV Application Specialists at Atlantic Ultraviolet Corporation assist customers in the selection of germicidal lamps and equipment. Their specialized knowledge is a valuable resource in formulating effective and cost-conscious ultraviolet solutions. Extensive inventories and a dedicated staff enable Atlantic Ultraviolet Corporation to fulfill its commitment to provide fast deliveries and responsive customer service. Model 2-OZ and 3-OZ free standing, wall or ceiling mount 2

ADVANTAGES PRINCIPLE OF OPERATION Effective Virtually all microorganisms are susceptible to Monozone ultraviolet disinfection. Economical System requires very little power to operate. The Monozone TM design has been carefully conceived to provide adequate germicidal ultraviolet and ozone exposure for air disinfection of unoccupied areas by the means of germicidal ultraviolet ozone lamps. These special lamps generate high levels of germicidal ultraviolet radiation which is lethal to infectious microorganisms such as bacteria, mold, and virus. Ozone that is emitted will remove mold, smoke, and other strong odors. The dosage, as it applies to ultraviolet and ozone disinfection, is a function of time, and the intensity, of ultraviolet radiation, to which the air is exposed. Our UV application specialist would be happy to perform the necessary calculations to ensure the equipment we provide is appropriate for your particular application. Fast Disinfects air in seconds. 4 Easy Simple installation and maintenance. Automatic Continuous disinfection. Durable Polished Stainless Steel and Aluminum. Versatile Units are portable and can be applied to different areas as needed. The operation of the Monozone is as follows: Model 6-OZ free standing, wall or ceiling mount 1. Clear area of all occupants. Monozone can only be used in unoccupied areas. Post warning signs at entryway of area that will be irradiated. 2. Turn Monozone on and leave area. 3 3. Air is drawn into Monozone generator through the washable electrostatic particulate filter(s). 4. The air is forced into the ultraviolet exposure chamber where it is irradiated by germicidal ultraviolet ozone lamp(s). 5. The purified air exits the generator, through the louvered exhaust panel, located at the opposite end of the generator. Air exiting the generator includes ozone. 6. Infectious microorganisms such as bacteria, mold, and virus are deactivated while mold, smoke, and other strong odors are removed. 7. Observation Port/Sight Glass provides positive indication of STER-L-RAY Germicidal Ultraviolet Ozone Lamp operation. 8. When area treatment is complete and the Monozone is off, ventilate the area before occupying. 7 ultraviolet.com buyultraviolet.com 3

SPECIAL FEATURES Monozone 2-OZ, 3-OZ and 6-OZ Ozone Generator Monozone Generators are germicidal ultraviolet ozone generators that effectively deactivate infectious microorganisms including bacteria, mold, and virus, and are available in different configurations to adapt to any setting. The Monozone Ultraviolet Ozone Generators utilize STER-L-RAY Germicidal Ozone Producing Lamps which are completely enclosed within a stainless steel exposure chamber and emit ozone that will remove mold, smoke, and other strong odors. STER-L-RAY Ozone-Producing Germicidal Lamp(s) Lamps are instant starting and provide the utmost in quality, sustained output, and longevity. (Lamp quantity varies by model.) Interlock Safety Switch The interlock safety switch is a standard feature that disconnects power to the unit when the access panel is unhinged for lamp or filter replacement. (located under the cover) Stainless Steel Enclosure The unit is manufactured in Type 304 stainless steel for unparalleled strength, durability and an attractive finish. Model 6-OZ (see Page 6 for Optional Accessories) Steadfast Lampholders Set includes a stationary and a spring-loaded, telescopic holder that holds a single pin lamp securely. The spring-loaded feature on one end facilitates convenient, quick and easy lamp changes. Louvers Exhaust Panel Restricts ultraviolet radiation from passing into the area. Polished Reflector Interior surface is polished providing a highly reflective surface to maximize ultraviolet intensity within the chamber Promate Observation Port/ Sight Glass Assembly A Sight Glass Assembly allows for visual inspection of the lamp(s). Promate Particulate Filter(s) Washable Electrostatic Filter Promate Standard Wall Mount Kit Consists of (2) pre-drilled stainless steel brackets. Brackets enable unit to be mounted to wall in either the vertical or horizontal position (included). 4

INSTALLATION Figure 1 - Monozone 2-OZ and 3-OZ (shown) For maximum efficiency the Monozone should be located as centrally as possible, preferably not close to the floor or the corners of the area to be treated. Access must be controlled and the area unoccupied while the generator is operating. The louvered exhaust panel of the Monozone Ozone Generator restricts ultraviolet radiation from passing into the area, but allows circulation of ozone that will remove mold, smoke, and other strong odors. All models can be installed utilizing wall mounting brackets included with purchase, or units can be left mobile to be moved as needed from one area to another. Promate Observation Port/ Sight Glass Assembly A Sight Glass Assembly allows for visual inspection of the lamp. SPECIFICATIONS Monozone 2-OZ, 3-OZ, & 6-OZ OZONE GENERATOR Model Nominal Unit Capacity (cubic feet/ min) Dimensions Length Width Depth Electrical * Requirements (Amps) Max. Room Size Treated @ 3 Room Air Changes/Hour (cubic feet/hour) Max. Room Size Treated @ 6 Room Air Changes/Hour (cubic feet/hour) Max. Treatment Capacity (cubic feet/ hour) 2-OZ 54 cfm 34-1/2 7-3/4 7-3/4 1.25 1,080 540 3,240 3-OZ 105 cfm 34-1/2 7-3/4 7-3/4 230 2,100 1,050 6,300 6-OZ 326 cfm 47-5/16 14 12 4.52 6,525 3,263 19,575 Unit capacity incorporates an estimated allowance for airflow friction loss across filter and unit. Information listed refers to 120 Volt 60 Hz units. Contact factory for specifics on other voltages. *Consult factory with specific power requirements. GENUINE STER-L-RAY GERMICIDAL LAMP DATA Lamp No. (Quantity) Model Lamp Length Lamp Length (including lampholders) Power Consumption Ultraviolet Output (per lamp) Rated Average Effective Life 05-1349-R (1) 2-OZ 21-7/8 (556 mm) 24 25 Watts 8.5 Watts 10,000 05-1349-R (2) 3-OZ 21-7/8 (556 mm) 24 25 Watts 8.5 Watts 10,000 05-0050-R (4) 6-OZ 27-7/8 (708 mm) 30 32 Watts 11.2 Watts 10,000 ultraviolet.com buyultraviolet.com 5

OPTIONAL ACCESSORIES APPLICATIONS SENTINEL Remote Lamp Indicator* The SENTINEL Remote Lamp Indicator monitors lamp operation of one, two, or four lamp ultraviolet fixtures and is available with a 25, 50 and 100 foot cable. (Available for ALL Monozone generators at the time of purchase, SENTINEL output connector needs to be installed for easy plug-in and operation.) Zenith Ultraviolet Meter A sensitive, hand-held, ultraviolet meter that can be used to survey installations to ensure that the germicidal ultraviolet radiant exposure, of personnel within the treated area, is within acceptable limits. The Zenith Ultraviolet Meter provides accurate and easy-to-read levels of intensity that may be interpreted by anyone not just engineers. It also checks the intensity of aging ultraviolet lamps. Promate Disposable Filters Cost effective, filters for use when frequent filter changes are necessary. Water Damage Fire/ Smoke Remediation Odor Mold Allergens Dust Mites Deodorizer Animal Odor Mildew Cooking Smells Promate Optional Wall Mount Kit Consists of (2) pre-drilled stainless steel brackets. Brackets are designed to provide a more aesthetic look for the installation while allowing unit to be mounted to the wall in a horizontal position. Restaurants Crawl Spaces Kennels Promate Ceiling Mount Kit Consists of (4) eye bolts used to suspend unit from ceiling. Promate Integral Elapsed Time Indicator* The Elapsed Time Indicator is a real-time, non-resettable display of accumulated operating time. Useful for scheduling and recording maintenance and lamp replacement. Food Processing Cars Manufacturing RVs Boats Promate Warning Signs To be affixed to entry door(s) to warn that an ultraviolet disinfection treatment is in progress and area should NOT be entered. * Item must be ordered at same time as Monozone Ozone Generator (installed at factory). Hotels & Motels Auditoriums Gymnasiums Locker Rooms 6

GENUINE STER-L-RAY GERMICIDAL LAMPS 100 Relative Spectral Energy Distribution (Typical) 100 Germicidal Effectiveness As Related to Wavelength INTENSITY 80 60 40 20 RELATIVE EFFECTIVENESS 80 60 40 20 0 100 200 300 400 500 600 WAVELENGTH (NANOMETERS) 0 200 225 250 275 300 WAVELENGTH (NANOMETERS) STER-L-RAY Germicidal Lamps are shortwave, low pressure mercury vapor discharge tubes that produce ultraviolet wavelengths lethal to microorganisms. Approximately 95% of the ultraviolet energy emitted from STER-L-RAY germicidal ozone producing lamps is at the mercury resonance line of 254 nanometers, the region of germicidal effectiveness most destructive to bacteria, mold and virus. STER-L-RAY Germicidal Ozone Producing Lamps - Ozone (O3) is a highly reactive form of oxygen and is useful as a deodorizer. Ultraviolet wavelengths shorter than 200 nanometers are capable of producing ozone from Oxygen (O2) in the air. Ozone (O3) will remove mold, smoke and other strong odors. STER-L-RAY ozone lamps, in addition to emitting germicidal ultraviolet output at 254 nanometer wavelength, also emit ozone producing rays at 185 nanometer wavelength. Because it is necessary to avoid exposing personnel to high concentrations of ozone, the use of ozone lamps is limited to applications in which ozone concentration will not exceed.05 parts per million in occupied spaces. STER-L-RAY and the STER-L-RAY logo are trademarks of Atlantic Ultraviolet Corporation. CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable faceshield, gloves and protective clothing. ULTRAVIOLET DOSAGE Germicidal lamps provide effective protection against microorganisms. A small cross-section is shown below. ORGANISM ALTERNATE NAME TYPE DISEASE DOSE* Corynebacterium diphtheriae C. diphtheriae Bacteria Diptheria 6,500 Legionella pneumophila L. pneumophila Bacteria Legionnaire s Disease 2,700 Mycobacterium tuberculosis M. tuberculosis Bacteria Tuberculosis (TB) 10,000 Pseudomonas aeruginosa P. aeruginosa Bacteria 3,900 Serratia Marcescens S. marcescens Bacteria 6,160 Staphlylococcus aureus S. aureus Bacteria 6,600 Staphlylococcus epidermidis S. epidermidis Bacteria 5,800 Adeno Virus Type III Virus 4,500 Coxsackie A2 Virus 6,300 Influenza Virus Flu 3,400 * Nominal Ultraviolet dosage (µwsec/cm2) necessary to inactivate better than 99% of specific microorganism. Consult factory for more complete listing. ultraviolet.com buyultraviolet.com 7

The Standard of Excellence In Ultraviolet Manufacturers / Engineers / Sales / Service Germicidal Ultraviolet - Equipment & Lamps 375 Marcus Boulevard Hauppauge, NY 11788 631.273.0500 Fax: 631.273.0771 E-mail: info@ultraviolet.com ultraviolet.com buyultraviolet.com The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation and are believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein. Specifications and information are subject to change without notice. Document No. 98-1464 November 2017 2017 by Atlantic Ultraviolet Corporation MADE IN THE USA