WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Similar documents
Water Detection Controllers

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

READ AND SAVE THESE INSTRUCTIONS

GL-CO-RFG Channel Gas Leak Alarm System

Installation, Operating and Maintenance Manual

PTE0705 Electric Fence Monitor

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Two-Channel Gas Controller

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

INSTALLATION INSTRUCTIONS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Analog Room Pressure Monitor RPC Series

EXTINGUISHING AGENT RELEASE MODULE

02/11/2015

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Pioneer-R16 Gas Monitor Operator s Manual

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Water Leak Detector. Installation and Troubleshooting. Overview

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Door Release Power Supply

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

INTRODUCTION / TABLE OF CONTENTS

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

WaterLeakStop Manual. Detection and Management of Water Leaks WLS-1

LEAKSTOPPER RANGE Multizone water leak detection systems

Operating Instructions. For. Alarm Control Module. Model SSR 500

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Product Manual SZ1145

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Multi-Gas-Controller MGC2

New Silent Alert Fire Safe System

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

INSTALLATION INSTRUCTIONS

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Flostop TS D7E and A8E. Operation Manual

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Technical Manual. Level Alarm Unit CARLA & WIDS

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

Product Manual SZ1144

CaterSense 03 & ATSC-02-xx

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

INSTALLATION & USER MANUAL

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

MODEL DESCRIPTION PAGE

Addressable Detectors & Bases

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Danfoss gas detection units

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Sensor Interface Module Installation/Operation Instructions

Instructions for the fan motor control system with integrated wiring terminals SILVER C

LEAKSTOPPER 1 Single zone water leak detection system

02/11/2015

Carbon Monoxide Transmitter

APPLICATION DATA SHEET

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

STATUS ALARM HISTORY ALARM RESET

RE-PR3-E-27 3-Phase Panel Mount 27kW

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

INSTALLATION INSTRUCTIONS

BX444-Mc Gas Detector

Installation and user manual for the BiWire / Conventional Repeater Panel

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Installation Instructions Model DLC

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

500-IDx Conventional Fire Detectors with Siren!

MBCE-110/230UV Flame Sensor Module

GAS SUPRESSION CONTROL PANEL:

Model A1600 Series Annunciator

CR Series Command Relays

Duct and Rough Service Carbon Monoxide Sensor

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

21-light Remote Annunciator. Owner s Manual

Power Supply Display Module PSDM. Installation and Operation Manual

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

Transcription:

Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction with the WD-AM range of detection modules. NB The cable excitation used from the WD-AM is an isolated AC signal which ensures the detectors will not be subject to oxidation or erosion over time, avoiding the degradation problems associated with DC systems. Features Easy to lay Detects water along its entire length Specification Product Codes Material PVC Twisted pair with stainless 316 elements WD-CS/2M Water leak cable sensor 2m cable 3m leader Dimension Maximum cable run Country of origin 3.5mm dia. 200m (Including detection cable) UK WD-CS/5M Water leak cable sensor 5m cable 3m leader WD-CS/10M Water leak cable sensor 10m cable 3m leader WD-CS/15M Water leak cable sensor 15m cable 3m leader WD-CS/20M Water leak cable sensor 20m cable 3m leader WD-CS/25M Water leak cable sensor 25m cable 3m leader Page 1

Data Sheet Ref: 90501085 WD-CS Water leak detection cable Installation 1. Fit the cable sensor to the floor, using suitable fixings 2. Connect the 2-core leader cable to the WD-AM alarm module and terminate at the sensor input (polarity independent). 3. Power the WD-AM, and adjust the pot on the PCB clockwise until the LED comes on, and then back until the LED goes off (when short a cable is used the LED may not even come on when set to max sensitivity). 4. You can test the cable by placing a wet cloth over the cable to simulate an water leak, the relay will come on. Remove the rag and when the cable dries the relay will go off. Page 2

Technical Overview The water leak detection modules are designed for use with the WD-CS, WD-PS and WD-RS water leak detection sensors. The modules have LED Indication of the water leak status and a sounder that can be enabled or disabled. The relay output is auto reset, and can be used as an alarm signal for connection to a BMS controller or remote alarm annunciation panel, such as the UI-AA1-F. Features LED Indication of leak status Auto reset alarm output Audible alarm Specification Product Codes Supply Voltage: -1 24Vac/dc ±10% -2 230Vac @ 50Hz Supply current 50mA max. Output 12A @ 250Vac LED Status indication for: Error condition Input sensitivity Learning Mode Response time <1 sec. after exposure Max. sensor cable length 200m (with leader cable) Alarm hysteresis Dependent on sensitivity Audible alarm output 85dB@2.3Hz @ 10cm Electrical Terminals for 0.5-2.5² cable Connections Rising cage Ambient: Temperature -10 C to 50 C RH 0-80% non-condensing Dimensions 72 x 64 x 55mm Country of origin UK -1 24Vac/dc water detection alarm module with audible alarm and LED status indication -2 230Vac water detection alarm module with audible alarm and LED status indication NB The cable excitation used is an isolated AC signal which ensures the detector cable will not be subject to oxidation or erosion over time, avoiding the degradation problems associated with DC systems. Warning! When installed, the output relay contacts may carry 240Vac. Special care must be taken to isolate the switched voltages prior to any work being undertaken. Page 1

Installation 1. The should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) LED status Green LED: The green LED should be on continuously during normal operation, except in the off mode (see page 3) or there is an error (see Error Indication ). 2. Ensure that all power is disconnected before carrying out any work on the. 3. Maximum cable is 2.5mm², care must be taken not to over tighten terminals. 4. When mounting the care should be taken not to stress the PCB when fitting to the DIN rail. If it is necessary to remove the module from the DIN rail, be sure to use a flat bladed screwdriver to release the DIN clips. 5. The -1 is designed to operate from a 24Vac or 24Vdc supply (so that power can be drawn from a 24Vac transformer used for other purposes if a 24Vdc supply is not available). The -2 is designed to operate from a 230Vac mains supply. Yellow LED: This will be on if the sensor reading is more than 33% of the threshold setting. Orange LED: This will be on if the sensor reading is more than 66% of the threshold setting. Red LED: This will be on solidly if the sensor reading exceeds the threshold setting. If the red LED is flashing, it is either because the unit is in test mode (see page 3) or, if the green LED is off, because the unit has discovered an error (see Error Indication ). Learning mode 6. The relay output is an SPDT type, allowing either a Normally Open (NO) or Normally Closed (NC) connection. Operation power-up, the unit enters learning mode, the mode jumper can be set to the required operating mode. In learning mode, the sensor sensitivity trimmer can be adjusted, and the level used as the threshold at which the unit will report an alarm. The unit will only be in learning mode for approximately 20 seconds after power-up. After this time, the unit will enter run mode, so that any adjustment of the trimmer has no effect. When the unit is first powered up, the sounder will be activated (if enabled) and the LED s demonstrated. The relay will be left de-energised for a minimum of two seconds. ce the relay has been energised, it will be held in this state for a minimum of two seconds, even if a flood is detected immediately. Changes in alarm threshold can only be made while the unit is in learning mode. Error indication If the unit thinks that there is an error (for example, the sensor reads such an extreme level that a short circuit is suspected) then the red LED will flash continuously, the relay will be de-energised, and the sounder will be activated (if enabled). The sounder pattern will be three tones followed by a gap, to differentiate it from the flood warning. The green LED will be off to differentiate between an error report and the Test mode. Adjusting the alarm threshold With the sensor connected, power the unit power up which will then allow you to enter learning mode and then slowly adjust the threshold trimmer. As the input becomes more sensitive, the yellow, orange and finally red LEDs will progressively light. If the red LED is lit, the sensitivity is set too high, and the unit is in alarm. Page 2

Jumper settings Connections Sounder link: Silent Active -1: Relay output C N/O N/C Sensitivity adjustment LED s C NO NC Relay Mode Link: LED1 LED4 Auto reset Mode Reset Latch Not used Gnd 24V Sensor Relay Output Modes: : The relay will be de-energised and the sounder silent, no matter what the sensor condition. The green and yellow LEDs will flash alternately while in learning mode, and then just the green LED will flash continuously to show that this mode is selected. The other three LED s will indicate as normal. -2: Jumpers 24Vac/dc 0V Input independent) Sensor (polarity Auto reset: The will report all flood alerts by releasing the relay and activating the sounder (if enabled). Any transition will be reported for a minimum of two seconds. When the sensor stops indicating a flood, the unit resets automatically. 240Vac supply 240Vac Relay output C N/O N/C C NO NC Sensitivity adjustment LED1 LED s : This is a mode used to test the installation without needing to wet the sensor. The sounder and relay will be energised and the green and red LEDs will flash alternately for approximately 2 minutes to show that this mode is selected. After this time, the green LED will be ON while the red LED will continue to flash. LED4 Mode Reset Latch Sensor Jumpers Sensor Input (polarity Independent) Page 3