PRODUCT GUIDE. Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ Phone Fax Web Seeleyinternational.

Similar documents
OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. Evaporative Cooler. (English) (EA, EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

Wall Controller & Thermostat

REMOTE CONTROL FAN SPEED ECONOMY BATTERY LOW. owner s manual

INSTALLATION MANUAL. TBA Evaporative Cooler. (English) (TBA) ILL1456-A

INSTALLATION MANUAL TBA Evaporative Cooler

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English)

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

Safety / Kit Components 1

WV Series Evaporative Cooler. Installation Manual

Spectrolink Comfort Control. Home Owner's Manual Heating

Brivis Service Manual

INSTALLATION MANUAL EA Evaporative Cooler

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

HOME OWNER S MANUAL. Spectrolink Comfort Control - Heating

TECHNICAL INFORMATION T 15xx Dryers

Commercial and Industrial Cooling. World-leading natural cooling technology

TECHNICAL INFORMATION T1500 Series Clothes Dryers

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030

Brivis Service Manual

Mobile Evaporative Cooler

INSTALLATION MANUAL. CPL CPS LCB BM Evaporative Cooler. (English) (CPL CPS LCB BM) (Original English Instructions) ILL1456-A

INSTRUCTION MANUAL. FOR MODELS MobileMAX II & MobileMAX III High Performance Mobile Evaporative Coolers

WC Series Vended Washers Troubleshooting, and Fault Codes

MODEL B2 INSTALLATION MANUAL

Auto Drain Installation Instructions.

OWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS

OWNER S MANUAL. CPL Evaporative Cooler. (English) (CPL) ILL1456-A

Spectrolink Comfort Controller. Home Owner's Manual Heating. baby, outside. Come home to ECOST R

Model 1820 Dehumidifier

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

REPAIR PART DIAGRAMS. Pages: 1-6

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

FOR SERVICE TECHNICIAN S USE ONLY

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Breezair RPA Series Installation Manual

Auto Drain Installation Instructions.

OWNER S MANUAL LCQ / LCS / LCQI / BMQ / CPQ TBQ / TBS / TBQI / TBSI Evaporative Cooler

PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F ,137,215, 232,

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

Portable Evaporative Cooling System

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

OWNERS INSTRUCTION MANUAL

TECHNICAL INFORMATION Touchtronic Clothes Dryers

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

ACE. HydroStream Model HC-100. Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications...

Operation and Maintenance Manual 120V/60HZ

WSK300 Multifunction Wall Control

Smart-Wall TV Kit - Installation & Operation Instructions -

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Your safety and the safety of others are very important.

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

Model Series Series

380 SERIES REMOTE SIREN ETSA380R

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

LEAKSTOPPER RANGE Multizone water leak detection systems

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

UF424 and UN324. Technical Service

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

BIX B-One 100 kw INSTALLATION GUIDE

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

DISHWASHER - PART RECOGNITION GUIDE

TECH SHEET - DO NOT DISCARD PAGE

AGP. (All Grade Pellet) Troubleshooting Guide Document Copyright 2017 Travis Industries Certified Factory Training Program

Operator: Save these instructions for future use!

CaterSense 03 & ATSC-02-xx

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Product Manual SZ1009

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

MPT Electric Fire Pump Controller

Scotsman Technical Training. CU50 Cube Ice Machine

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Owner s Manual RD432-0 Chemical Controller

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English) ILL1672-A

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

CAC series Portable Air-Cooled Spot Cooler

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Thermo 50 Coolant Heater. HMMWV 6.2 and 6.5 Liter Diesel. Table of Contents. Foreword

INDEX D1976 DISHWASHER (DW955)

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

FOR SERVICE TECHNICIAN S USE ONLY

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Transcription:

PRODUCT GUIDE 2017 Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ 85043 Phone 602 353 8066 Fax 602 353 8070 Web Seeleyinternational.com Seeley International has a policy of continuous product development and therefore reserves the right to make changes to cooler specifications without notice.

EXT 155/265 2 Speed Most Common Replacement Parts EXT 155/265 PART MFG# DESCRIPTION ORDER # 111568 J-BOX 2 SPEED 095455 MOTOR 2 SPEED 3/4 HP Breezair Model MFG# Industry Standard CFM Volts Amps Hi/Low Motor HP Weight LB Order # 095851 TORNADO WATER PUMP 115V EXT 155 042909 5500 115 8.4/5.6 0.75 HP 172 EXT 265 046716 6500 115 8.4/5.6 0.75 HP 206 107608 BLEED OFF FUNNEL/DRAIN ADAPTER EXT 155/265 MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING 2-SPEED JUNCTION BOX SEELECTRIC 2-SPEED MOTOR FAN ASSEMBLY TORNADO WATER PUMP FLOAT FALVE BLEED-OFF TRAY FOUR(4) CHILLCEL PADS EXT155 ROOF JACK ADAPTER 19 3/4 X 17 3/4 INCHES EXT265 ROOF JACK ADAPTER 19 3/4 X 19 3/4 INCHES 901497 114620 114613 4L480-S VERTICAL FLOAT VALVE CHILLCEL PAD 31.5X17.5X3.5 EXT155 (Set of 4) CHILLCEL PAD 31.5X25X3.5 EXT 265 (Set of 4) V-BELT A-46/ 4L-480 EXT155 MFG# 112152 OPTIONS Description SALINITY MANAGER (INCLUDES CONTROL BOX, AUTO DRAIN, SOLENOID, WATER PROBE AND PLUMBING FITTINGS) Order# 109459 826509 109459 V-BELT A-55/ 4L-570 EXT265 BEARING KIT

DIA# MFG# DESCRIPTION ORDER # 1 505152 Lid Beige 2 505350 Tank Beige 3 573625 Leg Extension 3A 509518 Leg Extension Foot 5 505855 Pad Frame Beige 6 114620 Chillcel Pad 31.5 x 17.5 x 3.5 EXT155 (Set of 4) 6 114613 Chillcel Pad 31.5 x 25 x 3.5 EXT265 (Set of 4) 6A 401959 Pad Retaining Pin 6B 401966 Pad Retaining Disc 7 506760 Spreader Water Distribution 7A 511412 4 way water Distributor 7B N/A Water Distribution Hose (special order) 8 507422 Corner Post EXT 155 8 507095 Corner Post EXT 265 8A 541679 Corner pad Clips 9 508122 Transition Scroll to Lid EXT265 10 116013 Scroll Assembly EXT 155 10 116020 Scroll Assembly EXT265 11 111568 J box 2 speed 12 507866 Motor Mount Plate 12 507873 Motor Mount Plate 13 095431 Motor 2 Speed 1/2 HP 13 095455 Motor 2 Speed 3/4 HP 13 095448 Motor 2 Speed 1 HP 14 108070 Motor Pulley 3 1/2" 15 4L480-S V-belt A-46 4L-480 EXT155 15 826509 V-belt A-55 4L-570 EXT265 16 112008 Installation Hardware Kit 17 501710 Fan Pulley 8" EXT155 17 501703 Fan Pulley 9" EXT265 18 501307 Fan Centrifugal EXT155 18 506814 Fan Centrifugal EXT265 19 504605 Fan Shaft Square S/Steel 20 109459 Bearing Kit 21 095851 Tornado Water Pump 115V 23 107608 Bleed Off Funnel/Drain Adaptor Kit 24 901497 Vertical Float Valve/Float Assembly

EXV 155/275 Variable Speed Most Common Replacement Parts EXV 155/275 PART MFG# DESCRIPTION ORDER # 110417 095264 095271 CPMD J-BOX VARIABLE SPEED MOTOR VAR SPEED 3/4HP EXV155 MOTOR VAR SPEED 1HP EXV275 Breezair Model MFG# Industry Standard CFM Motor Weight Volts Amps Order # HP LB EXV 155 042855 5500 115 7.5 0.75HP 172 EXV 275 046686 7500 115 10.2 1.0HP 212 EXV 155/275 MODEL COOLERS COME EQIPPPED WITH THE FOLLOWING VARIABLE SPEED CPMD JUNCTION BOX SEELECTRIC VARIABLE SPEED MOTOR FAN ASSEMBLY TORNADO PUMP FLOAT VALVE FOUR (4) CHILLCEL PADS EXV155 ROOF JACK ADAPTER 19 3/4 X 17 3/4 INCHES EXV275 ROOF JACK ADAPTER 19 3/4 X 19 3/4 INCHES PLEASE NOTE: EXV REQUIRES PURCHASE OF ONE OF THE FOLLOWING SPEED CONTROL KITS HARMONY SPEED CONTROL KIT INCLUDES WIRED WALL CONTROL 111940 WITH LEAD ASSEMBLY, SOLENOID AND HADRWARE, 24V AUTO DRAIN AND WATER PROBE 111957 HORIZON SPEED CONTROL KIT INCLUDES WIRELESS WALL CONTROL AND LEAD ASSEMBLY SOLENOID AND HARDWARE, 24V AUTO DRAIN AND WATER PROBE 095851 114620 115900 24V AUTO DRAIN SOLENOID 24V WATER PROBE CHILLCEL PAD 31.5X17.5X3.5 EXV155 (Set of 4) CHILLCEL PAD 31.5X25X3.5 EXV 265 (Set of 4) V-BELT A-47/ 4L-490 EXV 155 818054 V-BELT A-56/ 4L-580 EXV 275 110424 TORNADO WATER PUMP 115V 901497 VERTICLE FLOAT VALVE 105345 834320 833811 114613 832159 109459 BEARING KIT HARMONY SENSOR TOUCH WIRED WALL CONTROL HORIZON SENSOR TOUCH WIRELESS WALL CONTROL

DIA# MFG# DESCRIPTION ORDER # 1 505152 Lid Beige 2 505350 Tank Beige 3 573625 Leg Extension 3A 509518 Leg Extension Foot 5 505855 Pad Frame Beige 6 114620 Chillcel Pad 31.5 x 17.5 x 3.5 EXV155 (Set of 4) 6 114613 Chillcel Pad 31.5 x 25 x 3.5 EXV275 (Set of 4) 6A 401959 Pad Retaining Pin 6B 401966 Pad Retaining Disc 7 506760 Spreader Water Distribution 7A 511412 4 way water Distributor 7B N/A Water Distribution Hose(special order) 8 507422 Corner Post EXV 155 8 507095 Corner Post EXV 275 8A 541679 Corner pad Clips 9 508122 Transition Scroll to Lid EVT275 10 116013 Scroll Assembly EXV 155 10 116020 Scroll Assembly EXV 275 11 110417 CPMD J Box Variable Speed 11A 560298 CPMD J-Box Mounting Cradle 11B 834283 Main Power Junction Box 11C 110448 Receiver 12 507866 Motor Mount Plate EXV155 12 507873 Motor Mount Plate EXV275 13 095264 Motor Variable Speed 3/4hp 13 095271 Motor Variable Speed 1hp 14 108063 Motor Pulley 4" 15 832159 V-belt A-47 4L-490 EXV155 15 818054 V-belt A-56 4L-580 EXV275 16 112008 Installation Hardware Kit 17 501710 Fan Pulley 8" EXV155 17 501703 Fan Pulley 9" EXV275 18 501307 Fan Centrifugal EXV155 18 506814 Fan Centrifugal EXV275 19 504605 Fan Shaft Square S/Steel 20 109459 Bearing Kit 21 095851 Tornado Water Pump 115V 22 105345 24V Auto Drain 24 901497 Vertical Float Valve 25 834320 Solenoid Valve 24V (Not shown) 26 833811 Probe water sensor

EXH 170/210 Variable Speed Most Common Replacement Parts EXH 170/210 PART MFG# DESCRIPTION ORDER # 109930 CPMD J-BOX VARIABLE SPEED 095943 ECM MOTOR VARIABLE SPEED 1HP 095967 ECM MOTOR VARIABLE SPEED 2HP Breezair Model MFG# Industry Standard CFM Volts Amps Motor Size Weight Order # 095905 TORNADO WATER PUMP 230V EXH170 043739 7500 230 5.8 1.0HP 212 EXH210 046709 9500 230 9.0 2.0HP 212 EXH MODEL COOLERS COME EQIPPPED WITH THE FOLLOWING VARIABLE SPEED CPMD JUNCTION BOX ECM DIRECT DRIVE MOTOR FAN ASSEMBLY TORNADO PUMP (230 VOLT) FLOAT VALVE FOUR (4) CHILLCEL PADS EXH170/210 ROOFJACK ADAPTER 19 3/4 X 19 3/4 INCHES 901497 105345 834320 VERTICLE FLOAT VALVE 24V AUTO DRAIN SOLENOID 24v PLEASE NOTE: EXH REQUIRES PURCHASE OF ONE OF THE FOLLOWING SPEED CONTROL KITS 833811 114613 WATER MANAGER PROBE CHILLCEL PAD EXH170 (Set of 4) 111940 111957 HARMONY SPEED CONTROL KIT INCLUDES WIRED WALL CONTROL WITH LEAD ASSEMBLY, SOLENOID AND HADRWARE, 24V AUTO DRAIN AND WATER PROBE HORIZON SPEED CONTROL KIT INCLUDES WIRELESS WALL CONTROL AND LEAD ASSEMBLY SOLENOID AND HARDWARE, 24V AUTO DRAIN AND WATER PROBE 114583 CHILLCEL PAD EXH210 (Set of 4) 115900 110424 HARMONY SENSOR TOUCH WIRED WALL CONTROL HORIZON SENSOR TOUCH WIRELESS WALL CONTROL

DIA# MFG# DESCRIPTION ORDER # 1 505152 Lid Beige 2 505350 Tank Beige 3 573625 Leg Extension 3A 509518 Leg Extension Foot 5 505954 Pad Frame Beige 6 114613 Chillcel Pad Set of 4 EXH 170 (Set of 4) 6 114583 Chillcel Pad Set of 4 EXH 210 (Set of 4) 6A 401959 Pad Retaining Pin 6B 401966 Pad Retaining Disc 7 506760 Spreader Water Distribution 7A 511412 4 way water Distributor 7B N/A Water Distribution Hose special order) 8 507095 Corner Post 8A 541679 Corner pad Clips 9 508122 Transition Scroll to Lid 10 116020 Scroll Assembly 11 109930 CPMD J Box Variable Speed 11A 560878 J-Box Mounting Cradle 11B 834283 Main Power Junction Box 11C 110448 Receiver 13 095943 Motor Variable 1HP 13 095967 Motor Variable 2HP 18 109312 Fan Centrifugal 19 841397 Fan Shaft Round Alloy 20A 502007 Dust End Cap 20A 543253 Resilient Mount & Insert 20B 560793 Fan Shaft Seal 21 095905 Tornado Water Pump 230V 22 105345 Auto Drain 24V 24 901497 Vertical Float Valve Assembly 25 834320 Solenoid Valve 24V

TBA 450 Variable Speed Most Common Replacement Parts TBA 450 PART MFG# DESCRIPTION ORDER # 114880 CPMD J-BOX VARIABLE SPEED Breezair Model MFG# Industry Standard CFM Volts Amps Motor HP Weight LB Order # 095660 MOTOR VARIABLE SPEED 3/4 HP TBA 450 224091 10000 230 10 0.75HP 140 TBA MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING VARIABLE SPEED CPMD JUNCTION BOX DIRECT DRIVE MOTOR/FAN TORNADO PUMP (230 VOLT) FLOAT VALVE FOUR (4) CHILLCEL PADS 21 5/8" x 21 5/8" ROOFJACK/WEATHERSEAL TRANSITION ASSEMBLY WITH TBA SENSOR TOUCH WIRED WALL CONTROL WITH LEAD WATER MANAGER WITH AUTO DRAIN OPTIONAL PLENUM (AIR DIFFUSERS ) 4 SIDED OR 8 SIDED OPTIONS 095905 901497 105345 834320 TORNADO WATER PUMP 230V VERTICLE FLOAT VALVE 24V AUTO DRAIN SOLENOID 24V 089249 4 SIDED PLENUM 832811 WATER PROBE 111070 114095 832777 833897 834238 833934 834399 089256 8 SIDED PLENUM SMART HUB (65 CABLE INCLUDED) LINKS UP TO 4 COOLERS WITH SINGLE SMART HUB OR UP TO 41 COOLERS WITH 10 SWMART HUBS INDUSTRIAL WALL CONTROL KIT (65' CABLE, 131' CABLE AND REMOTE SENSOR INCLUDED) 65' CABLE ASSEMBLY 131' CABLE ASSEMBLY 197' CABLE ASSEMBLY 262" CABLE ASSEMBLY 328" CABLE ASSEMBLY 114606 110202 111650 CHILLCEL PAD 20.75X33.5X3.5 (Set of 4) TBA SENSOR TOUCH WIRED WALL CONTROL WEATHERSEAL TRANSITION ASSEMBLY WITH FLAPS

DIA# MFG# DESCRIPTION ORDER # 1 560014 Lid Grey 2 560052 Tank Grey 3 113098 Leg Support Kit with Foot (set of 4) 3A 509518 Leg Extension Foot 3B 111650 Weather seal Transition w/flaps 3C 111148 Weather seal Flaps only (2 ea) 5 560595 Pad Frame Grey 6 114606 Chillcel Pad 20.75 x 33.5 x 3.5 (Set of 4) 6A 401959 Pad Retaining Pin 6B 401966 Pad Retaining Disc 7B N/A Water Distribution Hose (not shown) 8 560236 Pillar Corner Post 10 560199 Fan Inlet Ring 11 114880 CPMD J-box Variable Speed 13 095660 Motor variable 3/4 hp 18 560168 Fan Axial 21 095905 Tornado Water Pump 230V 22 105345 Auto Drain 24V 24 901497 Vertical Float Valve 25 834320 Solenoid 24V 25C 857374 Flexible Hose and Washer Assembly 25F 539812 Extension Tube 26A 833811 Probe Water Sensor

TBS 500 Variable Speed Most Common Replacement Parts TBS 500 PART MFG# DESCRIPTION ORDER # 116099 CPMD J-BOX VARIABLE SPEED Breezair Model MFG# Industry Standard CFM Volts Amps Motor HP Weight LB Order # 091419 MOTOR VARIABLE SPEED 1 HP TBS 500 224114 10000 230 10 1.0HP 140 TBS MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING VARIABLE SPEED CPMD JUNCTION BOX DIRECT DRIVE MOTOR/FAN TORNADO PUMP (230 VOLT) (UL) FLOAT VALVE FOUR (4) CHILLCEL PADS 21 5/8" x 21 5/8" ROOFJACK/WEATHERSEAL TRANSITION ASSEMBLY WITH TBS MagiQtouch WIRED WALL CONTROL WITH LEAD WATER MANAGER WITH AUTO DRAIN OPTIONAL PLENUM (AIR DIFFUSERS ) 4 SIDED OR 8 SIDED OPTIONS 089249 4 SIDED PLENUM 116006 TORNADO WATER PUMP 230V (UL) 901497 VERTICLE FLOAT VALVE 105345 24V AUTO DRAIN 834320 SOLENOID 24V 832811 WATER PROBE 094328 089256 8 SIDED PLENUM MagiQtouch Air Sensor for Use with TBS500-G UL only 116242 CHILLCEL PAD 20.75X33.5X4.75 (Set of 4) 094274 MagiQtouch Multi Cooler Link Module for Use with TBS500-G UL only. (1 per Additional Cooler) 094632 MagiQtouch WALL CONTROL 833880 864402 861265 65' CABLE ASSEMBLY 6 Pin 131' CABLE ASSEMBLY 6 Pin 3M Communication Cable / Link Module 111650 WEATHERSEAL TRANSITION ASSEMBLY WITH FLAPS

DIA# MFG# DESCRIPTION ORDER # 1 560014 Lid Grey 2 560052 Tank Grey 3 113098 Leg Support Kit with Foot (set of 4) 3A 509518 Leg Extension Foot 3B 111650 Weather seal Transition w/flaps 3C 111148 Weather seal Flaps only (2 ea) 5 560595 Pad Frame Grey 6 116242 Chillcel Pad 20.75 x 33.5 x 4.75 (Set of 4) 6A 561066 Pad Retaining Pin 6B 401966 Pad Retaining Disc 7B N/A Water Distribution Hose (not shown) 8 560236 Pillar Corner Post 10 560199 Fan Inlet Ring 11 116099 CPMD J-box Variable Speed 13 091419 Motor variable 1 hp 18 115610 Fan Axial 21 116006 Tornado Water Pump 230V (UL) 22 105345 Auto Drain 24V 24 901497 Vertical Float Valve 25 834320 Solenoid 24V 25C 857374 Flexible Hose and Washer Assembly 25F 539812 Extension Tube 26A 833811 Probe Water Sensor

TBSI 580 Variable Speed Most Common Replacement Parts TBSI 580 PART MFG# DESCRIPTION ORDER # 116297 CPMD J-BOX VARIABLE SPEED Breezair Model MFG# Industry Standard CFM Volts Amps Motor HP Weight LB Order # 116983 MOTOR VARIABLE SPEED 1 HP TBSI 580 226156 10000 230 10 1.3HP 150 TBSI MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING VARIABLE SPEED ICPMD JUNCTION BOX DIRECT DRIVE MOTOR/FAN TORNADO PUMP (230 VOLT) (UL) FLOAT VALVE FOUR (4) CHILLCEL PADS 21 5/8" x 21 5/8" ROOFJACK/WEATHERSEAL TRANSITION ASSEMBLY WITH TBSI MagiQtouch WIRED WALL CONTROL WITH LEAD WATER MANAGER WITH AUTO DRAIN OPTIONAL PLENUM (AIR DIFFUSERS ) 4 SIDED OR 8 SIDED OPTIONS 089249 4 SIDED PLENUM 116006 TORNADO WATER PUMP 230V (UL) 901497 VERTICLE FLOAT VALVE 116389 12V AUTO DRAIN 865607 SOLENOID 12V 865621 WATER PROBE 094274 089256 8 SIDED PLENUM 094328 MagiQtouch Air Sensor MagiQtouch Multi Cooler Link Module for Use with TBSI580-G only. (1 per Additional Cooler) 833880 65' CABLE ASSEMBLY 6 Pin 864402 131' CABLE ASSEMBLY 6 Pin 861265 3M Communication Cable / Link Module 862873 1.5M Test Cable / Link Module 116242 094632 111650 CHILLCEL PAD 20.75X33.5X4.75 (Set of 4) MagiQtouch WALL CONTROL WEATHERSEAL TRANSITION ASSEMBLY WITH FLAPS

DIA# MFG# DESCRIPTION ORDER # 1 560014 Lid Grey 2 560052 Tank Grey 3 113098 Leg Support Kit with Foot (set of 4) 3A 509518 Leg Extension Foot 3B 111650 Weather seal Transition w/flaps 3C 111148 Weather seal Flaps only (2 ea) 5 560595 Pad Frame Grey 6 116242 Chillcel Pad 20.75 x 33.5 x 4.75 (Set of 4) 6B 561066 Pad Retaining Pin 6B 401966 Pad Retaining Disc 10A 560946 Motor Mount SuperStealth 8 560236 Pillar Corner Post 10 113085 Fan Inlet Ring 11 116297 CPMD J-box Variable Speed 13 116983 Motor variable 1.3hp 18 560922 Fan Axial 21 116006 Tornado Water Pump 230V (UL) 22 116389 Auto Drain 12V 24 901497 Vertical Float Valve 25 865607 Solenoid 12V 25C 850764 Flexible Hose and Washer Assembly 25F 539812 Extension Tube 26A 865621 Probe Water Sensor

ENVIROMAGIC Variable Speed Most Common Replacement Parts ENVIROMAGIC PART MFG# DESCRIPTION ORDER # 670645 COOLER CONTROL BOARD Breezair Model MFG# Industry Standard CFM ENV 086910 28,000 440 19.5 2 569 833897 Volts Amps Motor HP Weight LB Order # ENV MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING DIGITAL SMARTBOX CONTROL MODULE DIRECT DRIVE MOTOR/FAN HIGH VOLUME UL RATED CIRCULATION PUMP BUILDING MANAGEMENT SYSTEM ( BMS) INTERFACE NINE (9) CHILLCEL PADS ENV SENROR TOUCH WIRED WALL CONTROL WITH LEAD WATER MANAGER WITH AUTO DRAIN OPTIONS 131' CABLE ASSEMBLY 863351 MOTOR VARIABLE SPEED 2 HP 825441 560168 833835 HIGH VOLUME UL RATED CIRCULATION PUMP HIGH PERFORMANCE AXIAL FAN 114293 24V AUTO DRAIN 825250 SOLENOID 24V WATER PROBE 119991 CHILLCEL PAD 113210 ENV SENSOR TOUCH WIRED WALL CONTROL

DIA# MFG# DESCRIPTION ORDER # 1 565118 Lid and Spreader Assembly 2 861081 Eye Bolts and Lifting Lugs 3 565316 Tank Assembly 3D 116594 Duct Attachment Channels 3E 649955 Mount Plate 5 566009 Pad Frame ENV 6 119991 Chillcel Pad 6A 561066 Pad Retaining Pin 6B 401966 Pad Retaining Disc 7 650036 Water Deflector 8 565064 Corner Pillar External 8 565057 Corner Pillar internal 8A 541679 Corner pad clips 8B 561095 Corner Clip Internal 10 560199 Fan Inlet Ring ( Venturi) 11 114965 Control Assembly 11D 584331 Wall Mount Plate for 113210 11D 113210 ENV Sensor Touch Wall Control 11E 834245 Lead Assembly for Envriomagic only 65' 4 pin 13 560182 Collet for Motor Shaft 13 863351 Motor Variable Envriomagic 18 560168 Fan Axial 21 825441 Pump, Circulation NIDEC 22A 114293 Auto Drain 24V Enviromagic 25 825250 Solenoid valve 24V (Enviromagic only) 26A 833835 probe Sensor (Enviromagic only) 27 860442 Elbow(Pump to Spreader) 27A PVC Pipe Assembly 27B 862774 Joiner Barbed 27C 861180 Tee Piece for Tubing 27D 116570 Tube (Tank 2 to Tee) 27E 28 116570 670645 Tube (Tank 2 to Tee) Cooler Control Board (Not Shown)

MOBILEMAX 2/3 Most Common Replacement Parts MOBILEMAX 2/3 PART MFG# DESCRIPTION ORDER # 111575 JUNCTION BOX MOBILEMAX 2/3 095455 SEELEY MOTOR 2SPD 3/4HP MMAX2 095448 SEELEY MOTOR 2SPD 1HP MMAX3 Breezair Model MFG# Industry Standard CFM Volts Amps 2spd HI/LOW Motor Size HP Weight LB Order # 095851 TORNADO PUMP MMAX 2 056531 6500 115 8.4/5.6 3/4HP 188 MMAX 3 063539 8500 115 11/7.1 1.0HP 210 MOBILEMAX COOLERS COME EQUIPPED WITH THE FOLLOWING 2-SPEED JUNCTION BOX SEELECTRIC 2-SPEED MOTOR FAN ASSEMBLY TORNADO PUMP FLOAT VALVE THREE (3) ASPEN PADS 26 GALLON WATER TANK 2-SPEED CONTROL SWITCH WATER FITTINGS FOR HOSE HOOKUP 20' POWER CORD 095129 HORIZONTAL FLOAT VALVE 832890 4L-520/A50 FAN BELT MMAX2 826509 4L-570/A55 FAN BELT MMAX3 109459 BEARING KIT 100203 100258 ASPEN PAD 23 1/2 X 31 MMAX2 ASPEN PAD 32 X 34 MMAX3

DIA# MAG# DESCRIPTION ORDER # 1 117706 Tank MMAX2&3 Beige 1 117751 Tank MMAX2&3 Grey 2 505107 Lid Large MMAX2&3 Beige 2 505138 Lid Large MMAX2&3 Grey 3 505503 Front Panel Medium MMAX2 Beige 3 505534 Front Panel Medium MMAX2 Grey 3 505909 Panel Front Large MMAX3 Beige 3 505657 Panel Front Large MMAX3 Grey 4 505800 Pad Frame Medium MMAX2 Beige 4 505831 Pad Frame Medium MMAX2 Grey 4 505909 Pad Frame Large MMAX3 Beige 4 505930 Pad Frame Large MMAX3 Grey 5 100203 Aspen Pad (23.5x31) MMAX2 5 100258 Aspen Pad Large(32x34)MMAX3 6 100050 Pad Wire MMax2 6 100104 Pad Wire MMax3 7 507002 Corner Post 7 507101 Corner Post 10 504506 Plate Cut Off MMax2 10 513805 Plate Cut Off MMax3 15 834344 Switch Enclosure 15A 830124 Switch Plate 15B 830414 Toggle switch 30m20 26 543109 Small Mods MMax2 26 543055 Large Mods MMax3 27 095851 Tornado Water Pump 115V

GENERAL DIAGNOSTICS

INTERPRETING LED'S TRI-COLOR-LED Green - Red - Amber Red-LED Red LED Indicator Operating and Fault Code Diagnosis RED COLORED LED: This LED indicates the status of the conductivity measurement circuit and the status of the Salinity Control Method (1) Flash every 2 Seconds (2) Flashes every 2 Seconds (3) Flashes every 2 Seconds Continuously On Salinity Control Method= Water Manager is Enabled Salinity Control Method= Water Manager is Enabled Salinity Control Method= Set to drain every 65 minutes of pump operation Salinity Control Method= Water Manager is Enabled Measured salinity is below the set point Measured Salinity is above the set point Cooler will Drain every 65 minutes of Pump Operation Probes are Open Circuit (No Water in the Tank) or measured salinity is less than 12PPM The TRI-COLOR LED (right-hand LED) is used as an operational fault indicator. Note TRI-COLOR LED double flashing every 2 seconds = Normal Operation TRI-COLOR LED Indication Cooler Condition Reason Clearing Faults TRI-COLOR LED (2) Green Flashes No fault Indicated Double flash every 2 seconds indicates that control is running Normally No Fault detected No Fault detected (2) Green Flashes 1. If the cooler receives a valid messaage while the (1) Red Flash Indicates Fault Code #1 Communication failure Fan, Pump and Inlet valve are turned OFF. The Drain Valve stays in whatever position it was in. Time lapsed since receiving a valid message from rremote Control exceeded 30 minutes fault code is present, the fault will be cleared and the cooler will opperate according to the message 2. Disconnect Power Supply to cooler for 10 seconds and then restore Power. Reverts to (2) Green Flashes (2) Red Flashes Indicates Fault Code #2 Failure to detect water at probes Water Inlet valve and Pump are turned OFF. Fan will be off unless control is set to Manual Vent Mode Water not detected at the probes for approximately 17 minutes Turn Remote Control off then on Reverts to (2) Green Flashes (4) Red Flashes Indicates Fault Code #4 Failure to Clear probes during drain Drain Valve Closed and pump turned OFF. Fan will be off unless control is set to Manual Vent Mode Water did not drain from tank within approximately 8 minutes from the time Drain Valve opened and the Inlet valve closed Turn Remote Control Off then On Reverts to (2) Green Flashes (7) Red Flashes Indicates Fault Code #7 Incorrect supply frequency Fan, Pump and Inlet Valve are turned OFF Power Supply frequency is not within 55 to 65 Hz for a period of time. Turn Remote Control Off then On Reverts to (2) Green Flashes Amber flashing Incorrect Remote Control address Cooler will not opperate Cooler does nor recognize Remote Control Re-Configure Remote for cooler Reverts to (2) Green Flashes

Quick Reference Guide Component Part Number EXT EXV EXH TBA TBS Volt Watts Capacitor Total Max Amps Motor Windings Resistance [Ω] (with Capacitior Disconnected) Orange/Brown Orange/Blue Grey/Black O95455 155 115/1 550 30uf 8.4/5.6 1.28 3.05 7 O95455 265 115/1 550 30uf 8.4/8.6 1.28 3.05 7 Orange/Blue Orange/Black Grey/Black O95264 155 115/1 550 30uf 7.2 2.6 8.9 6.3 O95271 275 115 750 40uf 10.5 1.2 5.7 4.5 Motor Windings Resistance (Measured on Motor Cord Plug) O95943 170 230/1 750 Fan Motor O95967 210 230/1 1500 Run/Com Run/Start Com/Start (Measured on Motor Cord Plug) Run Common Start Ground O95660 450 230/1 550 30 4.5 8.2 13.7 5.7 O91419 500 230/1 750 30 5.5 3.1 6.8 3.9 (Measured on pump Cord Plug) Tornado Pump O95851 EXT EXV 115/1 80 0.7 O95905 EXH TBA TBS 230/1 90 0.4 16.8 Ω 56.5 Ω

EA/EM RANGE 115v, 60hZ - Quick reference guide Component EA/EM Range part No. ohms with cap disconnected HP Amps Capacitor Fan Motor 2 Speed EA EM Motor with Pulley org-brn (aux) org-blu (main+aux) grey-blk (start) 148 145 095431 2.68 4.45 7.05 5.9/3.2 30uf 155 095455 1.28 3.05 7 0.75 8.4/5.6 30uf 265 265 095455 1.28 3.05 7 0.75 8.4/5.6 30uf 385 275 095448 1.25 2.25 4.3 1.0 11.0/7.1 40uf

EXV EXH(ICON) Setup Multiple Coolers with Remote Controls Cooler Number 1 Cooler Number 2 Turn Power on at CPMD Turn Power on at CPMD Within the first 4 minutes after power is applied to the CPMD install the batteries in the remote control Within the first 4 minutes after power is applied to the CPMD install the batteries in the remote control After 5 seconds the Remote control will display Id for 1 second After 5 seconds the Remote control will display Id for 1 second When the display 12:00 the Remote control is set and can be turned on. When the display 12:00 the Remote control is set and can be turned on. Before setting up the next cooler ensure that the power to cooler number 1 has been on for more that 5 minutes or you may shut off power to cooler # 1 at that the CPMD. This will ensure that the remote you are currently setting up will be recognized my the correct cooler. Additional Coolers Follow the steps for setting up cooler # 2 making sure that the power to previously set up coolers has either been on for more than 5 minutes or is turned off at the CPMD s PAGE 3

J-BOX EXH MODEL

FLOW CHARTS

FLOWCHART INDEX 1. SET UP OF HORIZON REMOTE CONTROL. EXV, EXH 2. SET UP MULTIPLE COOLERS WITH REMOTE CONTROLS. EXV, EXH 3. TROUBLESHOOTING HORIZON REMOTE CONTROL COMMUNICATION ISSUES. EXV, EXH 4. INITIAL SET UP OF HARMONY WIRED WALL CONTROL. EXV, EXH 5. ENTERING PARAMETER MODE USING HARMONY WIRED WALL CONTROL. EXV, EXH, TBA 6. COOL FUNCTION TIMING SEQUENCE WITH HORIZON REMOTE CONTROL DIP SWITCH 4 OFF. EXH 7. COOL FUNCTION TIMING SEQUENCE WITH HORIZON REMOTE CONTROL DIP SWITCH 4 ON. EXH 8. COOL FUNCTION TIMING SEQUENCE WITH HARMONY WIRED WALL CONTROL, COOLER OFF LESS THAN 10 MINUTES. EXH 9. COOL FUNCTION TIMING SEQUENCE WITH HARMONY WIRED WALL CONTROL, COOLER OFF MORE THAN 10 MINUTES. EXH 10. COOL FUNCTION TIMING SEQUENCE WITH HORIZON REMOTE CONTROL DIP SWITCH 4 OFF. EXV 11. COOL FUNCTION TIMING SEQUENCE WITH HORIZON REMOTE CONTROL DIP SWITCH 4 ON. EXV 12. COOL FUNCTION TIMING SEQUENCE WITH HARMONY WIRED WALL CONTROL, COOLER OFF LESS THAN 10 MINUTES. EXV 13. COOL FUNCTION TIMING SEQUENCE WITH HARMONY WIRED WALL CONTROL, COOLER OFF MORE THAN 10 MINUTES. EXV 14. COOL FUNCTION TIMING SEQUENCE WITH SENSOR TOUCH WIRED WALL CONTROL, COOLER OFF LESS THAN 10 MINUTES. TBA 15. COOL FUNCTION TIMING SEQUENCE WITH SENSOR TOUCH WIRED WALL CONTROL, COOLER OFF MORE THAN 10 MINUTES. TBA 16. COMMUNICATION FAILURE HORIZON WIRELESS WALL CONTROL, FAULT CODE 1. EXV EXH 17. COMMUNICATION FAILURE WIRED WALL CONTROL, FAULT CODE 1. EXV EXH TBA 18. POWER INTERUPTION, FAULT CODE 8. EXV EXH TBA

EXV EXH(ICON) Set up of Horizon Remote Control Turn Power on at CPMD Within the first 4 minutes after power is applied to the CPMD install the batteries in the remote control If communication between the remote control and the cooler are not achieved After 5 seconds the Remote control will display Id for 1 second Check batteries or receiver and receiver cable at CPMD When the display goes blank again the Remote control is set and can be turned on. PAGE 1

EXV and EXH(ICON) Troubleshooting Horizon Remote control Communication Issues With main power to the cooler ON, when any button on the Horizon Remote is Pressed The Tri Color Led goes Steady state Green momentarily indicating CPMD has received proper signal and then returns to flashing green Remote Control is operating properly Fault code = 00 The Tri Color Led does not go Steady state Green momentarily but continues flashing green indicating no signal was received. Check Batteries, receiver and receiver connection Refer to Remote Control Setup Flowchart Fault code = 01 The Tri Color Led flashes Amber momentarily indicating CPMD address has not been set correctly and returns to flashing green Refer to Remote Control setup Flowchart. Note: Under normal operation the tri-color diagnostic led on the CPMD flashes green. PAGE 2

EXV and EXH(ICON) Initial Setup of Harmony Wall control Turn on power to CPMD Connect Harmony wall control to CPMD. Wall Control will show Service in the display. If the wall control display does not display service and communication between the wall control and the cooler has not been established Press and hold the down arrow for 9 seconds. The display will go Blank. Check Wall Control wiring and power to the CPMD The Wall control is now set up and can be turned on. PAGE 4

EXV, EXH(ICON) and TBA Entering parameter Mode using Wired Wall Control or IWC Turn OFF main power to unit for minimum of 6 seconds While still holding the AUTO button press the down button Turn ON main power to unit With wall control set to OFF Press and hold Auto for 3 seconds Minimum. Display should read A1 Param To change from Parameters A1-A9 or B1- B5 Press down button To View parameter value press AUTO Screen will display A# or B# and actual parameter value. To Change parameter value press up or down until desires parameter value is reached To exit parameter mode without saving changes press Power To Save changed parameters press auto, Display will return to A# Param screen Note: Entering Parameter mode can only be done within 4 minutes of main power being applied to CPMD. PAGE 5

EXH(ICON) MODELS Cool Function Timing Sequence with Horizon Remote Control * DIP switch 4 on Remote Control set to OFF Tank Empty Turn power on and insure Cooler is set to cool function Tank Full Fan starts Auto Drain Closes Pump Starts Fan Starts 9 second delay Solenoid turns on Tank fills, water reaches probes Note: When DIP switch # 4 on the bottom row in the Remote Control is set to OFF the cooler will not enter Pre-Cool when turned on. After 30 second delay Pump starts PAGE 6

EXH MODELS Cool Function Timing Sequence with Horizon Remote Control * DIP switch 4 on Remote Control set to ON Tank Empty Turn power on and ensure unit set to cool Tank Full Auto Drain Closes Pump Starts 9 second delay Fan starts at completion of Pre-cool Cycle Solenoid turns on Tank fills, water reaches probes After 30 second delay Note: When DIP switch # 4 on the bottom row in the Remote Control is set to ON the cooler will enter Pre-Cool each time it is turned on in Cool or changed from Vent to Cool. Pump starts Fan Starts at completion of Precool cycle PAGE 7

EXH Models Cool Function Timing Sequence With Harmony Wired Wall Control. *Cooler off for less than 10 minutes. Turn power on and ensure unit set to cool Tank Empty Fan starts. Auto Drain Closes Tank Full Pump Starts Fan Starts 9 second delay Solenoid turns on Tank fills, water reaches probes Note. When the cooler has been off for less than 10 minutes and was last set to Cool it will not enter Precool when turned back on. After 30 second delay Pump starts PAGE 8

TBA Model Cool Function Timing Sequence With Sensor Touch Wired Wall Control. *Cooler off for more than 10 minutes. Tank Empty Turn power on and ensure unit is set to Cool Tank Full Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Pump Starts Fan starts at completion of Precool Cycle Tank fills, water reaches probes Pump stops After 30 second delay Pump starts Fan starts at completion of Pre- Cool Cycle If water drops below probes for more than 12 seconds PAGE 15 Note. When the cooler has been off for more than 10 minutes it will enter a Pre- Cool cycle when turned on and set to Cool

EXH Model Cool Function Timing Sequence With Harmony Wired Wall Control. *Cooler off for more than 10 minutes. Tank Empty Turn power on and ensure unit is set to Cool Tank Full Auto Drain Closes Pump Starts 9 second delay Solenoid turns on Fan starts at completion of Precool Cycle Tank fills, water reaches probes After 30 second delay Note. When the cooler has been off for more than 10 minutes it will enter a Pre- Cool cycle when turned on and set to Cool Pump starts Fan starts at completion of Pre- Cool Cycle PAGE 9

EXV MODELS Cool Function Timing Sequence with Horizon Remote Control * DIP switch 4 on Remote Control set to OFF Tank Empty Turn power on and insure Cooler is set to cool function Tank Full Fan starts Auto Drain Closes 9 second delay Solenoid turns on Tank fills, water reaches probes After 30 second delay After 30 second delay Tank fills, water reaches probes Pump stops If water drops below probes for more than 12 seconds Pump Starts Fan Starts Note: When DIP switch # 4 on the bottom row in the Remote Control is set to OFF the cooler will not enter Pre-Cool when turned on. Pump starts PAGE 10

EXV MODELS Cool Function Timing Sequence with Horizon Remote Control * DIP switch 4 on Remote Control set to ON Tank Empty Turn power on and ensure unit set to cool Tank Full Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Pump Starts Fan starts at completion of Pre-cool Cycle Tank fills, water reaches probes After 30 second delay Pump starts Pump stops If water drops below probes for more than 12 seconds Note: When DIP switch # 4 on the bottom row in the Remote Control is set to ON the cooler will enter Pre-Cool each time it is turned on in Cool or changed from Vent to Cool. Fan Starts at completion of Precool cycle PAGE 11

EXV Models Cool Function Timing Sequence With Harmony Wired Wall Control. *Cooler off for less than 10 minutes. Turn power on and ensure unit set to cool Tank Empty Fan starts. Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Tank Full Pump Starts Fan Starts Tank fills, water reaches probes After 30 second delay Pump starts Pump stops If water drops below probes for more than 12 seconds PAGE 12 Note. When the cooler has been off for less than 10 minutes and was last set to Cool it will not enter Precool when turned back on.

EXV Models Cool Function Timing Sequence With Harmony Wired Wall Control. *Cooler off for more than 10 minutes. Tank Empty Turn power on and ensure unit is set to Cool Tank Full Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Pump Starts Fan starts at completion of Precool Cycle Tank fills, water reaches probes Pump stops After 30 second delay Pump starts Fan starts at completion of Pre- Cool Cycle If water drops below probes for more than 12 seconds PAGE 13 Note. When the cooler has been off for more than 10 minutes it will enter a Pre- Cool cycle when turned on and set to Cool

TBA Models Cool Function Timing Sequence With Sensor Touch Wired Wall Control. *Cooler off for less than 10 minutes. Turn power on and ensure unit set to cool Tank Empty Fan starts. Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Tank Full Pump Starts Fan Starts Tank fills, water reaches probes After 30 second delay Pump starts Pump stops If water drops below probes for more than 12 seconds PAGE 14 Note. When the cooler has been off for less than 10 minutes and was last set to Cool it will not enter Precool when turned back on.

HORIZON WIRELESS WALL CONTROL Fault Code 1 Communication Failure Green LED changes to red and gives 1 red flash This happens when the CPMD loses communication with the Horizon Wireless Wall Control for 30 minutes or more. Horizon Wireless Wall Control has been moved out of range of receiver, or signal is being blocked by an obstruction Weak or low batteries in Wall Control. Problem with Receiver, or Receiver cable. Move remote closer to location of receiver. Cooler will resume operation in 2 to 10 minutes. Replace batteries with new alkaline type (AAA). Turn cooler on using wall control to resume operation PAGE 16 Replace Receiver or Cable Turn cooler on using wall control to resume operation

WIRED WALL CONTROL Fault Code 1 Communication Failure Green LED changes to red and gives 1 red flash This happens when the CPMD loses communication with the Harmony Wall Control for 10 seconds or more Harmony Wall control disconnected. Reconnect Wall Control and manually restart cooler using wall control. If cooler indicates Service on display clear service indication by holding down arrow for 10 seconds. And restart cooler. Defective Wall Control. Replace Wall Control and clear service indication by holding down arrow for 10 seconds. Restart cooler with Wall Control Cable from CPMD to Harmony Wall Control damaged. Replace Cable. Clear Service indication by holding down arrow for 10 seconds. Restart cooler with Wall Control PAGE 17

POWER INTRUPTION FAULT CODE 8 COOLER SHUTS OFF UNEXPECTEDLY Power Interruption for less than 5 seconds Power Interruption for more than 5 seconds Wired Wall Control Wireless Wall Control Wired Wall Control Wireless Wall Control Cooler will restart once power resumes Cooler will restart in 2 to 10 minutes after power resumes Cooler will require a manual restart using wall control Cooler will restart in 2 to 10 minutes after power resumes PAGE 18

NOTES..

1002 S 56 Ave Suite 101 Phoenix AZ 85043 Ph 602-353-8066 Fax 602-353-8070