standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

Similar documents
standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

STANDARD/quick. Sprinkler 42o. August 8, 2011

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

TECHNICAL DATA. Page 1 of 5

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

December 14, 2015 Page 1 of 7 TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA OBSOLETE

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

Standard Spray concealed horizontal sidewall sprinkler VK481

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

freedom residential concealed pendent Sprinkler vk458 (K7.4)

quick response horizontal sidewall sprinkler vk360 (K8.0)

TECHNICAL DATA. Page 1 of 6

sprinkler vk538 (K11.2)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

quick response Sprinkler 105a October 25, 2010

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

microfast quick response extended coverage hsw sprinkler vk606

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

micromatic Standard response Horizontal Sidewall sprinkler

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response Fusible Link Upright sprinkler VK204 (K8.0)

standard response fusible link sidewall sprinkler VK112 (K5.6)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

Microfast quick response Fusible element hsw sprinkler

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

micromatic standard response stainless steel sprinklers

microfast and microfasthp quick conventional sprinklers

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA OBSOLETE

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

standard response/ quick response extended coverage

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

freedom residential concealed pendent sprinkler VK488 (K3.0)

microfast quick response Pendent sprinkler VK302 (K5.6)

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

standard response elo upright and pendent sprinklers (storage-density/area)

standard response large orifice dry

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

standard/quick response extended coverage light and ordinary hazard elo sprinklers

freedom residential concealed pendent lead free sprinkler

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

standard response dry horizontal sidewall sprinklers

micromatic standard response Upright sprinkler VK100 (K5.6)

standard response elo upright sprinkler

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

micromatic Standard response Horizontal Sidewall sprinkler

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

Transcription:

May 1, 2009 Sprinkler 41g 1. DESCRIPTION Viking Standard/Quick Response Concealed Pendent Sprinklers are thermosensitive glass bulb spray sprinklers pre-assembled with a threaded adapter for installation with a domed cover that provides up to ½ (12.7 mm) of vertical adjustment. The cover plate is available with several decorative finishes to meet design requirements. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2015 Refer to the Approval Chart on page 41i and Design Criteria on page 41j for culus listing and FM approval requirements that must be followed. 3. technical data Specifications: Available since 2003. Viking Technical Data may be found on Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically The Viking Corporation s Web site at to 500 psi (34.5 bar). http://www.vikinggroupinc.com. Testing: U.S.A. Patent No. 4,831,870 The Web site may include a more recent Thread sizes: Sprinkler VK302: 1/2 (15 mm) NPT edition of this Technical Data Page. Sprinkler VK352: 3/4 (20 mm) NPT Nominal K-Factors: Sprinkler VK302: 5.6 U.S. (80.6 metric*) Sprinkler VK352: 8.0 U.S. (115.2 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 F (-55 C) Spring: U.S.A. Patent No. 4,167,974 Overall Length (sprinkler body): Sprinkler VK302: 2-1/4 (57 mm) Sprinkler VK352: 2-5/16 (59 mm) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Ejector Spring (Sprinkler VK352): 17-7 Stainless Steel Compression Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment (Sprinkler VK352): Brass UNS-C36000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Form No. F_070803 Replaces page 41g-l, dated May 16, 2008. (Revised VdS Approval.)

Sprinkler 41h May 1, 2009 Ordering Information: (Also refer to the current Viking price list.) Viking Standard/Quick Response Concealed Pendent Sprinklers VK302 and VK352 and Cover Plate Assembly must be ordered separately: Sprinkler: Base Part No. 06662BA-X or 06666BA-X (includes sprinkler and adapter pre-assembled, with a protective plastic cap covering the unit) Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix ( F/ C): 155 /68 = B, 175 /79 = D, 200 /93 = E For example, concealed sprinkler VK302 with a 155 F/68 C temperature rating = 06662BABX. Note: When ordering this sprinkler using the SIN, add suffix -D. For example, concealed sprinkler VK302 = VK302-D. Cover Plate Assembly: Base Part No. 12381 Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/SW1004, Painted Ivory = M-/SW1634, Painted Black = M-/SW1007 Temperature Suffix ( F/ C): 135 /57 = A (for use with 155 /68 rated sprinklers only), 165 /74 = C (for use with 175 /79 or 200 /93 rated sprinklers). For example, cover 12381 with a Polished Chrome finish and a 135 F/57 C temperature rating = 12381FA. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrench: Part No. 13577W/B** (available since 2006) **A ½ ratchet is required (not available from Viking). Sprinkler Cabinet: Five-head capacity: Part No. 01731A (available since 1971) 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability The Viking Quick Response Concealed Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Figure 1: Concealed Sprinkler VK302 and Cover 12381

May 1, 2009 Sprinkler 41i Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Bulb Color Ordinary 155 F (68 C) 100 F (38 C) Red Intermediate 175 F (79 C) 150 F (65 C) Yellow Intermediate 200 F (93 C) 150 F (65 C) Green Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory, or Painted Black 1 The sprinkler temperature rating is stamped on the deflector. Footnotes 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinkler Base Part Number 1 SIN NPT Thread Size Approval Chart Standard/Quick Response Concealed Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Nominal K-Factor Overall Length (Sprinkler Body) Listings and Approvals 3 (Refer also to Design Criteria on page 41j.) Inch mm U.S. metric 2 Inches mm culus 4 FM 5 NYC VdS LPCB Quick Response Applications 06662BA-X VK302 1/2 15 5.6 80.6 2-1/4 57 AW1, BX1 -- -- -- -- 06666BA-X VK352 3/4 20 8.0 115.2 2-5/16 59 AW1, BX1 -- -- -- -- Standard Response Applications 06662BA-X VK302 1/2 15 5.6 80.6 2-1/4 57 -- AW1, BX1 -- AW1, CX1 -- 06666BA-X VK352 3/4 20 8.0 115.2 2-5/16 59 -- AW1, BX1 -- AW1, CX1 -- Sprinkler Temperature Ratings A - 155 F (68 C) B - 175 F (79 C) and 200 F (93 C) C - 200 F (93 C) Cover Plate Assembly Temp. Ratings 6 W - 135 F (57 C) cover 12381 1 X - 165 F (74 C) cover 12381 1 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Finishes of the Cover Plate Assembly 7 1 - Polished Chrome, Painted White, Painted Ivory, or Painted Black 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriter s Laboratories for use in the U.S. and Canada. 5 FM Approval of limited to wet systems and preaction systems qualifying as wet systems, for Light Hazard Occupancies where allowed by the installation standards being being applied, and Ordinary Hazard Group I and II Occupancies. 6 The 135 F cover has an orange label. The 165 F cover has a white label. 7 Standard painted finishes consist of Polyester Baked Enamel manufactured by Sherwin-Williams. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3.

Sprinkler 41j May 1, 2009 culus Listing Requirements: DESIGN CRITERIA (Also refer to the Approval Chart on page 41i.) Viking Concealed Pendent Sprinklers VK302 and VK352 are culus Listed quick response as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. DEFLECTOR POSITION: Install Concealed Pendent Sprinklers VK302 and VK352 with the deflector 3/8 (9.5 mm) to 7/8 (22.2 mm) below the ceiling. Refer to Figures 4 and 5. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. FM Approval Requirements: Viking Concealed Pendent Sprinklers VK302 and VK352 are FM Approved as standard response sprinklers as indicated in the Approval Chart for Light Hazard Occupancies where allowed by the installation standards being applied, and Ordinary Hazard Group I and II Occupancies. Install in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. VdS Listing Requirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupancies, except in OH4. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 or SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

May 1, 2009 Sprinkler 41k Figure 2: Sprinkler Installation and Correct Use of Wrench Figure 3: Identification of Custom Paint Color for Concealed Covers Figure 4: Concealed Sprinkler VK302 Dimensions and Cover Installation

Sprinkler 41l May 1, 2009 Figure 5: Concealed Sprinkler VK352 Dimensions and Cover Installation Form No. F_070803 Replaces page 41g-l, dated May 16, 2008. (Revised VdS Approval.)