Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Similar documents
Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler. Product Features. Product Description

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Model F1FR Series Quick Response Standard Spray

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

microfast quick response Pendent sprinkler VK302 (K5.6)

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

TECHNICAL DATA. Page 1 of 5

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

standard response Fusible Link Upright sprinkler VK204 (K8.0)

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

STANDARD/quick. Sprinkler 42o. August 8, 2011

mirage standard response concealed pendent sprinkler vk492 (K5.6)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

standard response dry horizontal sidewall sprinklers

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

Model F3 Dry Sprinklers

Standard Spray concealed horizontal sidewall sprinkler VK481

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

Microfast quick response Fusible element hsw sprinkler

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

micromatic standard response Upright sprinkler VK100 (K5.6)

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

Sprinkler Identification Numbers

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Sprinkler Identification Numbers

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA OBSOLETE

micromatic Standard response Horizontal Sidewall sprinkler

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

microfast sr/qr extended coverage pendent sprinkler

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

TECHNICAL DATA NOTICE

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

micromatic standard response stainless steel sprinklers

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

esfr pendent sprinkler vk510 (k25.2)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

microfast and microfasthp quick conventional sprinklers

quick response horizontal sidewall sprinkler vk360 (K8.0)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

standard response fusible link sidewall sprinkler VK112 (K5.6)

standard response large orifice dry

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

micromatic Standard response Horizontal Sidewall sprinkler

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response elo upright sprinkler

Transcription:

Bulletin 034 Rev. F Model G5 Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Product Features Model G5 Series Sprinkler s Flat concealed cover plate available solid or perforated in a variety of finishes. NEW: Stainless Steel Clad cover plate (see Table H). 3/4-inch (19 mm) cover plate adjustment. Cover plate available with optional gasket. Product Description Model G5 series sprinklers are standard coverage, flat plate concealed sprinklers designed for installation in accordance with NFPA 13. The sprinklers are offered with a standard Model cover plate (solid or perforated), a Model cover plate with a Quick-response () gasket, or a Model cover plate with a Standard-response (SR) gasket. Model G5 sprinklers must only be used with the Model cover plate listed or approved with the sprinkler. All Model G5 series sprinklers use a fusible-link operating element. Table A provides a summary of available Model G5 series sprinklers, along with Listing and Approval information for each sprinkler and cover plate combination. Model (Solid) Model Gasket Model Cover Plate (Perforated) Model SR Gasket Model G5 Series Sprinkler Summary Sprinkler Model G5-28 G5-42 K-Factor gpm/psi 1/2 (L/min/bar 1/2 ) 2.8 (40) 4.2 (60) G5-56 5.6 (80) G5-56 300 G5-80 5.6 (80) 8.0 (115) Model Listings and Approvals Max. Working Pressure psi (bar) Table A Sprinkler Identification Number (SIN) FM SR 175 (12) RA3411 Gasket SR Gasket, FM SR Gasket 175 (12) RA3413 SR Gasket SR 250 (17) FM, LPCB, VdS, CE SR 175 (12) Gasket 250 (17) RA3415 SR 250 (17) SR Gasket FM SR 175 (12) Gasket 300 (21) RA4014 SR Gasket SR Gasket 175 (12) RA3412 SR Gasket SR

Model G5-28 Standard Coverage, Concealed Pendent Sprinkler SIN RA3411 : 1/2 NPT or ISO 7-1 R1/2 Nominal K-Factor: 2.8 (40 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler : Brass Alloy s: Copper Alloy : Steel 212 F (100 C) (See Table B) s Model (Solid or Perforated) Model Gasket ( only) Model SR Gasket Finishes (See Table G) Listed (Light Hazard only) FM Approved Model G5-28 Sprinkler Components and Dimensions Figure 1 Adjustment Model G4 3-5/16" (84 mm) Model G5-28 Sprinkler Table B Model FM SR Gasket -- SR Gasket SR SR : Quick-response Bulletin 034 Rev. F Page 2 of 8

Model G5-42 Standard Coverage, Concealed Pendent Sprinkler SIN RA3413 : 1/2 NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.2 (60 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler : Brass Alloy s: Copper Alloy : Steel 212 F (100 C) (See Table C) s Model (Solid or Perforated) Model Gasket Model SR Gasket Finishes (See Table G) Listed (Light Hazard only) Model G5-42 Sprinkler Components and Dimensions Figure 2 Adjustment Model G4 3-5/16" (84 mm) Model G5-42 Model Table C Gasket SR Gasket : Quick-response SR Bulletin 034 Rev. F Page 3 of 8

Model G5-56 Standard Coverage, Concealed Pendent Sprinkler SIN RA3415 : 1/2 NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) ( only) Sprinkler : Brass Alloy s: Copper Alloy : Steel 212 F (100 C) (, FM, LPCB, CE only) (See Table D) s Model (Solid or Perforated) Model Gasket ( only) Model SR Gasket ( and FM only) Finishes (See Table D) Listed (Light & Ordinary Hazard only) FM Approved LPCB Approved VdS Approved [ only] CE Listed Model G5-56 Sprinkler Components and Dimensions Figure 3 Adjustment Model G4 3-5/16" (84 mm) Model G5-56 Table D Model FM LPCB, VdS, CE SR SR Gasket -- -- SR Gasket SR SR -- : Quick-response Bulletin 034 Rev. F Page 4 of 8

Model G5-56 300 Standard Coverage, Concealed Pendent Sprinkler SIN RA4014 : 1/2 NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 300 psi (21 bar) Sprinkler : Brass Alloy s: Copper Alloy : Steel 212 F (100 C) (See Table E) s Model (Solid or Perforated) Model Gasket Model SR Gasket Finishes (See Table G) Listed (Light & Ordinary Hazard only) Model G5-56 300 Sprinkler Components and Dimensions Figure 4 Adjustment Model G4 3-5/16" (84 mm) Model G5-56 300 Model Table E Gasket SR Gasket : Quick-response SR Bulletin 034 Rev. F Page 5 of 8

Model G5-80 Standard Coverage, Concealed Pendent Sprinkler SIN RA3412 : 3/4 NPT or ISO 7-1 R3/4 Nominal K-Factor: 8.0 (115 metric) Max. Working Pressure: 175 psi (12 bar) Sprinkler : Brass Alloy s: Copper Alloy : Steel 212 F (100 C) (See Table F) s Model (Solid or Perforated) Model Gasket Model SR Gasket Finishes (See Table G) Listed (Light & Ordinary Hazard only) Model G5-80 Sprinkler Components and Dimensions Figure 5 Adjustment Model G4 3-5/16" (84 mm) Model G5-80 Model Table F Gasket SR Gasket : Quick-response SR Bulletin 034 Rev. F Page 6 of 8

Installation Dimensions and Information Model (2) Gasket (3) SR Gasket (3) Cover Plate Diameter 3-5/16 (84) 3-11/16 (94) 4 (101 mm) Recommended Hole Diameter in 2-5/8 (67) Adjustment 3/4 (19) Min. to Max. Face of Fitting to (1) 1-1/2 to 2-1/4 (38 to 57) Min. to Max. Dropped Deflector Distance below 1/4 to 1 (6 to 25) Table G Temperature Rating F ( C) 135 F (4) (57 C) or 165 F (5) (74 C) Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2 x 1/2 brass nipple extension (Reliable P/N 6999991900) is available to assist with replacement of Reliable Model G4A sprinklers. 2. Model cover plates are available either solid or perforated. 3. Model Gasket and Model SR Gasket cover plates are sold as assembled units including both the cover plate and gasket. Model Gasket and Model SR Gasket cover plates and gaskets are not interchangeable. 4. For use with temperature rated sprinklers where the Maximum Temperature does not exceed 100 F (38 C). 5. For use with 212 F (100 C) temperature rated sprinklers where the Maximum Temperature does not exceed 150 F (66 C). Finishes (1) Table H Standard Finishes Special Application Finishes White Paint Off White Paint Chrome Black Paint Custom Color Paint Specify (2) Raw Brass (Lacquered) Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad (3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. Gaskets for Model Gasket and Model SR Gasket cover plates are only available in white. 2. Custom color paint is semi-gloss unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Application Model G5 series sprinklers are standard coverage, flat plate concealed pendent sprinklers. The sprinklers are intended for use in accordance with NFPA 13, as well as the requirements of the applicable approval agencies. Model G5 series sprinklers are available as either Quick-response () or Standard-response (SR) depending on the approval agency and cover plate selected. Model G5 series sprinklers use Model flat cover plates. Model Gasket and SR Gasket cover plates are available to limit air and dust movement through the ceiling. Listing & Approval Agencies Individual Model G5 series sprinkler may be listed or approved by the following agencies: Underwriters Laboratories, Inc. and UL Canada () Listing Category: Sprinklers, Automatic and Open Guide Number: VNIV FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhütung GmbH (VdS) EC-Certificate of Conformity 0832-CPD-2062 (CE) See Table A and the individual sprinkler data sheets in this Bulletin for listings and approvals applicable to each sprinkler. Bulletin 034 Rev. F Page 7 of 8

P/N 9999970421 Installation Model G5 series sprinklers are intended to be installed in accordance with NFPA 13 and the requirements of other applicable authorities having jurisdiction. Model G5 series sprinklers must not be installed in ceilings with positive pressure in the space above. Model G5 series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model G5 series sprinkler are installed with the wrench. The use of any other wrench to installed Model G5 series sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The wrench is designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler s threads. Recommended installation torque is specified in Table I. Installation Torque Sprinkler Table I Recommended Installation Torque (min. max.) ft-lb N-m ½ NPT or ISO7-1R1/2 8-18 11-24 ¾ NPT or ISO7-1R3/4 66 14-20 19-27 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Maintenance Reliable Model G5 series sprinkler should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler or cover plate which has been painted (other than factory applied). Properly installed Model cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Model G5 series sprinklers have holes in the cup that must remain unobstructed. Replace any sprinkler which has been damaged. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit. Patents Model G5 series sprinklers may be covered by one or more of the following patents: U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent 8,776,903, U.S. Patent 9,248,327 Ordering Information Install the cover plate by hand, turning the cover in the clockwise direction until it is tight against the ceiling. For Model Gasket and Model SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt only. Do not glue the gasket in place or allow the gasket to overlap both the cover plate and the flange of the skirt. Specify the following when ordering. Sprinkler Model (G5-28, G5-42, G5-56, G5-56 300, G5-80) Temperature Rating [ or 212 F (100 C)] (NPT or ISO 7-1) Model ( [Solid], Perforated, Gasket, SR Gasket) Finish (See Table G) Bulletin 034 Rev. F Page 8 of 8